Magnetic fluid sloshing in solenoidal magnetic field, describing fluid free surface waves similarity to ordinary liquid waves in reduced gravity field
Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.
A three axis magnetometer system intended for use in the magnetic measurement of lunar rock samples was designed, fabricated and delivered to NASA Manned Spacecraft Center. The system has a four inch diameter room temperature sample access region and is fitted with three orthogonal magnetic field sensors enclosing this region. Two superconducting magnetic shields are incorporated, which are designed to eliminate external magnetic noise from the sense coils. A superconducting solenoid is mounted coaxially with the sample region and this provides axial magnetic fields up to 1,000 gauss. The system was designed for measuring magnetic moments of geophysical samples, especially remanent moments of lunar samples. The sensitivity of the system in all three axes is about 2 x 10 to the -7th power EMU square root HZ peak to peak, measured in the 0 to 1 Hz bandwidth.
A pressure ramp programmer model was designed, fabricated and tested. This model, in conjunction with an automatic blood pressure monitor, automatically controls the pressure in the blood pressure monitor arterial cuff. The cuff pressurization cycle is designed to maximize accuracy and repeatability of blood pressure measurements. The key feature of this automatic cycle is rapid blood pressure cuff bleed down from an initial setting until systolic (diastolic) pressure is encountered followed by a short repressurization and slow bleed, long enough to permit accurate systolic (diastolic) pressure determination. The system includes a pressure reservoir which bleeds the cuff through a precision needle valve; a solenoid valve which permits rapid pressurization from the reservoir; and a pressure sensor which provides information for bleed rate and set point controls. Korotkoff sound signals from a microphone in the blood pressure cuff (not part of the system) provide decision information to the digital control system. The system completed a series of engineering tests using simulated Korotkoff sound inputs. The system performed successfully in all cases and was stable over an extended period of time.
A manually operated fuel-cell system was modified to be monitored and controlled by a digital computer. The purpose was to have a test item with which to study possible system-computer interface problems. The modification consisted of installing solenoid valves, circuitry, transducers, and limit switches on the system. These modifications permit computer control of load current, reactant purge, water removal, and electrolyte concentration and computer initiation of system shutdown.
Low-field magnetization measurements were made at 4.2 K on thin-film and bulk NbN samples by using a vibrating-sample Foner magnetometer with a 50-kG superconducting solenoid. Values of the lower and upper critical fields are calculated, using magnetization curves as the basis. The significance of the Pauli spin paramagnetism and spin-orbit scattering in these materials is discussed.
Research papers on superconducting interactions and properties and on amorphous materials are presented. The search for new superconductors with improved properties was largely concentrated on the study of properties of thin films. An experimental investigation of interaction mechanisms revealed no new superconductivity mechanism. The properties of high transition temperature, type 2 materials prepared in thin film form were studied. A pulsed field solenoid capable of providing fields in excess of 300 k0e was developed. Preliminary X-ray measurements were made of V3Si to determine the behavior of cell constant deformation versus pressure up to 98 kilobars. The electrical properties of amorphous semiconducting materials and bulk and thin film devices, and of amorphous magnetic materials were investigated for developing radiation hard, inexpensive switches and memory elements.
The guidelines for selecting hardware to be used in manned spacecraft to obtain a five year operational lifetime without maintenance were developed. An analysis was conducted on the design, application, failure mechanisms, manufacturing processes and controls, screen and burn-in techniques, and quality control of hardware items. The equipment considered for evaluation include: (1) electric motors and bearings; (2) accelerometers; (3) gyroscopes and bearings; (4) compressors and pumps, (5) magnetic tape recorders; (6) plumbing components and tubing; (7) check valves; (8) pressure regulators and solenoid valves; (9) thermal control valves; (10) pressure vessels and positive expulsion devices; (11) nickel cadmium batteries; and (12) transducers.
A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.
A method of producing a twisted, stabilized wire or tube superconductor which can be used to wind electromagnets, armatures, rotors, field windings for motors and generators, and other magnetic devices which use a solenoid, toroidal, or other type winding is reported. At least one groove is formed along the length of a wire substrate which is then twisted into a helix and a layer of intermetallic superconducting material is formed in the groove. This layer can be formed by depositing the desired intermetallic compound into the groove or by diffusing one component of the superconductor into the groove formed in a substrate composed of the other component. The superconductor prepared by this method comprises a non-superconductor wire twisted into the shape of a helix, having at least one groove containing a layer of superconductor material along the length of the wire.
Development of methods for generating high laser pulse energy has stimulated research leading to new ideas for practical controlled thermonuclear fusion machines. A review is presented of some important efforts in progress, and two different approaches have been selected as examples for discussion. One involves the concept of very short pulse lasers with power output tailored, in time, to obtain a nearly isentropic compression of a deuterium-tritium pellet to very high densities and temperatures. A second approach utilizing long wavelength, long pulse, efficient gas lasers to heat a column of plasma contained in a solenoidal field is also discussed. The working requirements of the laser and various magnetic field geometries of this approach are described.
Numerical calculations for the electric current in the polar ionosphere have been made by assuming some realistic distributions of the electric field and conductivity. Two dynamo actions are taken into account; one of which is induced by ionospheric winds and the other by the solar wind. For the solar wind dynamo action, it is found that the secondary polarization field caused by nonuniform distribution of ionospheric conductivity is much larger than the primary field induced by the solar wind, suggesting its important effect on charged particles in the magnetosphere, and that the irrotational current having a source and sink is of the same order of magnitude as the solenoidal current closing its circuit in the ionosphere. It is also found that the solar wind is, in general, more effective than the ionospheric winds in producing polar current systems such as DP 1 and 2, but in some cases the ionospheric winds have a significant effect on the current distribution.
Valve was developed for autopilot wing-lever system and is to be used in light, single-engine aircraft. Valve is controlled by electronic circuit which feeds pulse-width-modulated correction signals to two solenoids. Valve housing is cast from plastic, making it very economical to fabricate.
The design details and initial test results of a superconducting magnetic mirror facility that has been constructed at NASA Lewis Research Center for use in thermonuclear research are summarized. The magnet system consists of four solenoidal coils which are individually rated at 5.0 T. Each coll is composed of an inner, middle, and outer winding. The inner winding is wound of stabilized Nb3Sn superconducting ribbon, and the middle and outer windings are wound of stabilized Nb-Ti superconducting wire. When arranged in the mirror geometry, the four coils will produce 8.7 T at the mirrors and a 1.8 mirror ratio. The magnet has a 41-cm diameter clear bore which is open to atmosphere. Distance between the mirrors is 111 cm. Presently there are only three magnets in the facility; the fourth magnet is being rebuilt.
A digital controller for controlling the operation of a folding machine enables automatic folding of a desired number of sheets responsive to entry of that number into a selector. The controller includes three decade counter stages for corresponding rows of units, tens and hundreds push buttons. Each stage including a decimal-to-BCD encoder, a buffer register, and a digital or binary counter. The BCD representation of the selected count for each digit is loaded into the respective decade down counters. Pulses generated by a sensor and associated circuitry are used to decrease the count in the decade counters. When the content of the decade counter reaches either 0 or 1, a solenoid control valve is actuated which interrupts operation of the machine. A repeat switch, when actuated, prevents clearing of the buffer registers so that multiple groups of the same number of sheets can be folded without reentering the number into the selector.
A vessel having inlet and outlet valves is disposed in a container with a fluid to be pumped which may be evolved from a liquid in the container below the vessel. A magnetocaloric substance is disposed in the vessel and causes fluid vapor in the vessel to expand and be expelled through the outlet valve. Vapor is drawn in through the inlet valve as the substance cools. The inlet valves may be one-way check valves or may be solenoid valves energized at appropriate times by timing circutis. A timer controlled heating element may also be disposed in the vessel to operate in conjunction with the magnetic field.
This report summarizes the design details and initial test results of a superconducting magnetic mirror facility that has been constructed at NASA Lewis Research Center for use in thermonuclear research. The magnet system consists of four solenoidal coils which are individually rated at 5.0 T. Each coil is composed of an inner, middle, and outer winding. The inner winding is wound of stabilized Nb3SN superconducting ribbon, and the middle and outer windings are wound of stabilized Nb-Ti superconducting wire. When arranged in the mirror geometry, the four coils will produce 8.7 T at the mirrors and a 1.8 mirror ratio. The magnet has a 41-cm diameter clear bore which is open to atmosphere. Distance between the mirrors is 111 cm. Presently there are only three magnets in the facility; the fourth magnet is being rebuilt.
An atmosphere control subsystem (ACS) was developed for use in a closed manned cabin, such as the Space Shuttle Orbiter. This subsystem uses the Perkin Elmer mass spectrometer for continuous measurement of major atmospheric constituents (H2, H2O, N2, O2, and CO2). The O2 and N2 analog signals are used as inputs to the controller, which produces a pulse-frequency-modulated output to operate the N2 gas admission solenoid valve and an on-off signal to operate the O2 valve. The proportional controller characteristic results in improved control accuracy as compared with previously used on-off controllers having significant dead-band. A 60-day evaluation test was performed on the ACS during which operation was measured at various values of control setpoint and simulated cabin leakage.