Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A dynamic Bayesian optimized active recommender system for curiosity-driven partially Human-in-the-loop automated experiments

Optimization of experimental materials synthesis and characterization through active learning methods has been growing over the last decade, with examples ranging from measurements of diffraction on combinatorial alloys at synchrotrons, to searches through chemical space with automated synthesis robots for perovskites. In virtually all cases, the target property of interest for optimization is defined a priori with the ability to shift the trajectory of the optimization based on human-identified findings during the experiment is lacking. Thus, to highlight the best of both human operators and AI-driven experiments, here we present the development of a human–AI collaborated experimental workflow, via a Bayesian optimized active recommender system (BOARS), to shape targets on the fly with human real-time feedback. Here, the human guidance overpowers AI at early iteration when prior knowledge (uncertainty) is minimal (higher), while the AI overpowers the human during later iterations to accelerate the process with the human-assessed goal. We showcase examples of this framework applied to pre-acquired piezoresponse force spectroscopy of a ferroelectric thin film, and in real-time on an atomic force microscope, with human assessment to find symmetric hysteresis loops. It is found that such features appear more affected by subsurface defects than the local domain structure. This work shows the utility of human–AI approaches for curiosity driven exploration of systems across experimental domains.

36 MATERIALS SCIENCE↗

Complementary first and second derivative methods for ansatz optimization in variational Monte Carlo

We present a comparison between a number of recently introduced low-memory wave function optimization methods for variational Monte Carlo in which we find that first and second derivative methods possess strongly complementary relative advantages. While we find that low-memory variants of the linear method are vastly more efficient at bringing wave functions with disparate types of nonlinear parameters to the vicinity of the energy minimum, accelerated descent approaches are then able to locate the precise minimum with less bias and lower statistical uncertainty. By constructing a simple hybrid approach that combines these methodologies, we show that all of these advantages can be had at once when simultaneously optimizing large determinant expansions, molecular orbital shapes, traditional Jastrow correlation factors, and more nonlinear many-electron Jastrow factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumentation for a multichord motional Stark effect diagnostic in KSTAR

The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1–3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiographic detection of defects in friction stir welding on aluminum alloy AMg5M

In order to reveal weld defects specific to friction stir welding we undertook radiographic inspection of AMg5M aluminum alloy welded joints. Weld defects in the form of voids have been revealed in the weld obtained under the non-optimal rotation and feed rate. Both shape and size of these defects have been confirmed by examining metallographically successive sections prepared in the weld plane as well as in the plane transversal to the tool feed direction. Linear defects have been also found in the sections that are not seen in the radiographic images. Both the preferable localization and origination of the defects have been analyzed.

36 MATERIALS SCIENCE↗

Electrodeposition of Zn based nanostructure thin films for photovoltaic applications

We present here a systematic study on the synthesis thin films of various ZnO, CdO, Zn{sub x}Cd{sub 1-x} (O) and ZnTe nanostructures by electrodeposition technique with ZnCl{sub 2,} CdCl{sub 2} and ZnSO{sub 4} solution as starting reactant. Several reaction parameters were examined to develop an optimal procedure for controlling the size, shape, and surface morphology of the nanostructure. The results showed that the morphology of the products can be carefully controlled through adjusting the concentration of the electrolyte. The products present well shaped Nanorods arrays at specific concentration and temperature. UV-VIS spectroscopy and X-ray diffraction results show that the product presents good crystallinity. A possible formation process has been proposed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Flow around a helically twisted elliptic cylinder

In the present study, we conduct unsteady three-dimensional simulations of flows around a helically twisted elliptic (HTE) cylinder at the Reynolds numbers of 100 and 3900, based on the free-stream velocity and square root of the product of the lengths of its major and minor axes. A parametric study is conducted for Re = 100 by varying the aspect ratio (AR) of the elliptic cross section and the helical spanwise wavelength (λ). Depending on the values of AR and λ, the flow in the wake contains the characteristic wavelengths of λ, 2λ, 6λ, or even longer than 60λ, showing a wide diversity of flows in the wake due to the shape change. The drag on the optimal (i.e., having lowest drag) HTE cylinder (AR = 1.3 and λ = 3.5d) is lower by 18% than that of the circular cylinder, and its lift fluctuations are zero owing to complete suppression of vortex shedding in the wake. This optimal HTE configuration reduces the drag by 23% for Re = 3900 where the wake is turbulent, showing that the HTE cylinder reduces the mean drag and lift fluctuations for both laminar and turbulent flows.

42 ENGINEERING↗

Design of high-pressure iron Rayleigh–Taylor strength experiments for the National Ignition Facility

Iron is an important metal, scientifically and technologically. It is a common metal on Earth, forming the main constituent of the planet's inner core, where it is believed to be in solid state at high pressure and high temperature. It is also the main component of many important structural materials used in quasistatic and dynamic conditions. Laser-driven Rayleigh–Taylor instability provides a means of probing material strength at high pressure and high temperature. The unavoidable phase transition in iron at relatively low pressure induces microstructural changes that ultimately affect its strength in this extreme regime. This inevitable progression can make it difficult to design experiments and understand their results. Here, we address this challenge with the introduction of a new approach: a direct-drive design for Rayleigh–Taylor strength experiments capable of reaching up to 400 GPa over a broad range of temperatures. We use 1D and 2D hydrodynamic simulations to optimize target components and laser pulse shape to induce the phase transition and compress the iron to high pressure and high temperature. At the simulated pressure–temperature state of 350 GPa and 4000 K, we predict a ripple growth factor of 3–10 depending on the strength with minimal sensitivity to the equation of state model used. The growth factor is the primary observable, and the measured value will be compared to simulations to enable the extraction of the strength under these conditions. These experiments conducted at high-energy laser facilities will provide a unique way to study an important metal.

36 MATERIALS SCIENCE↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Integrated operation of steady-state long-pulse H-mode in Experimental Advanced Superconducting Tokamak

Recent Experimental Advanced Superconducting Tokamak (EAST) experiments have successfully demonstrated a long-pulse steady-state scenario with improved plasma performance through integrated operation since the last IAEA FEC in 2016. A discharge with a duration over 100 s using pure radio frequency (RF) power heating and current drive has been obtained with the required characteristics for future long-pulse tokamak reactors such as good energy confinement quality (H 98y2 ~ 1.1) with electron internal transport barrier inside ρ < 0.4, small ELMs (frequency ~100–200 Hz), and good control of impurity and heat exhaust with the tungsten divertor. The optimization of X-point, plasma shape, the outer gap and local gas puffing near the low hybrid wave (LHW) antenna were integrated with global parameters of BT and line-averaged electron density for higher current drive efficiency of LHW and on-axis deposition of electron cyclotron heating in the long-pulse operation. More recently, a high βP RF-only discharge (β P ~ 1.9 and β N ~ 1.5, $\langle$n e $\rangle$/n GW ~ 0.80, f bs ~ 45% at q 95 ~ 6.8) was successfully maintained over 24 s with improved hardware capabilities, demonstrating performance levels needed for the China Fusion Engineering Test Reactor steady-state operation. In this work, a higher energy confinement is observed at higher β P and with favorable toroidal field direction. Towards the next goal (≥400 s long-pulse H-mode operations with ~50% bootstrap current fraction) on EAST, an integrated control of the current density profile, pressure profile and radiated divertor will be addressed in the near future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the transition from continuous turbulence fluctuations to bursting ELMs in high SOL density regimes

BOUT++ turbulence simulations of the DIII-D reveal that the density profile between the separatrix and pedestal plays a crucial role in the dynamics of edge localized modes (ELMs) and edge plasma turbulent transport. Nonlinear simulations demonstrate that small ELMs in the DIII-D hybrid scenario under high SOL density conditions are predominantly driven by local ballooning modes near the separatrix, stabilizing global instabilities while enhancing localized pressure fluctuations. A key control parameters for ELM dynamics is the separatrix-to-pedestal density ratio, n e,sep /n e,ped . A high ratio indicates a shallow gradient, favoring small ELMs, while a lower ratio signals a steep gradient, which increases the likelihood of large ELMs. Comprehensive parameter scans, including n e,sep /n e,ped , density gradient profiles near the separatrix, and resistivity, reveal the critical role of these parameters in shaping transitions between turbulence-driven transport and ELM bursting. The scans demonstrate that in high SOL density regimes, small ELMs can result from either global resistive MHD instabilities or local ballooning modes near the separatrix, depending on the steepness of the separatrix density gradient. These findings also highlight the transition from continuous turbulence to small ELMs. The post-crash peak in pressure fluctuations, δP rms serves as a critical metric for identifying transition from continuous turbulence fluctuations to ELM bursting. Larger δP rms values correlate with ELM bursts driven by local or global instabilities, whereas smaller values indicate turbulence-dominated transport. Drift-Alfvén and resistive ballooning turbulence enhance the entrainment of fluctuations from the pedestal to the SOL, contributing to the complex interplay of dynamics in this regime. These findings emphasize the importance of separatrix density shaping and pedestal gradient control for optimizing ELM behavior in ITER and future fusion devices.

Li, Nami [Lawrence Livermore National Laboratory (↗

Selective Enhancement of Spectroscopic Features by Quantum Optimal Control

Tailored light can be used to steer atomic motions into selected quantum pathways. In optimal control theory (OCT), the target is usually expressed in terms of the molecular wave function, a quantity that is not directly observable in experiment. In this study, we present simulations using OCT that optimize the spectroscopic signal itself. By shaping the optical pump, the x-ray stimulated Raman signal, which occurs solely during the passage through conical intersections, is temporally controlled and amplified by up to 2 orders of magnitude. This enhancement can be crucial in order to bring small coherence-based signatures above the detectable threshold. Our approach is applicable to any signal that depends on the expectation value of a positive definite operator.

74 ATOMIC AND MOLECULAR PHYSICS↗

Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided doses over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of convergent collimators for pixelated SPECT systems

Purpose: The optimization of the collimator design is essential to obtain the best possible sensitivity in single photon emission computed tomography imaging. The aim of this work is to present a methodology for maximizing the sensitivity of convergent collimators, specifically designed to match the pitch of pixelated detectors, for a fixed spatial resolution value and to present some initial results using this approach. Methods: Given the matched constraint, the optimal collimator design cannot be simply found by allowing the highest level of septal penetration and spatial resolution consistent with the imposed restrictions, as it is done for the optimization of conventional collimators. Therefore, an algorithm that interactively calculates the collimator dimensions, with the maximum sensitivity, which respect the imposed restrictions was developed and used to optimize cone and fan beam collimators with tapered square-shaped holes for low (60-300 keV) and high energy radiation (300-511 keV). The optimal collimator dimensions were locally calculated based on the premise that each hole and septa of the convergent collimator should locally resemble an appropriate optimal matched parallel collimator. Results: The optimal collimator dimensions, calculated for subcentimeter resolutions (3 and 7.5 mm), common pixel sizes (1.6, 2.1, and 2.5 mm), and acceptable septal penetration at 140 keV, were approximately constant throughout the collimator, despite their different hole incidence angles. By using these input parameters and a less strict septal penetration value of 5%, the optimal collimator dimensions and the corresponding mass per detector area were calculated for 511 keV. It is shown that a low value of focal distance leads to improvements in the average sensitivity at a fixed source-collimator distance and resolution. The optimal cone beam performance outperformed that of other optimal collimation geometries (fan and parallel beam) in imaging objects close to the collimator surface. Conclusions: These results demonstrate the potential of this kind of optimal convergent collimators for the use in small field of view imaging applications.

43 PARTICLE ACCELERATORS↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

Optimal control of the strong-field ionization of silver clusters in helium droplets

Optimal control techniques combined with femtosecond laser pulse shaping are applied to steer and enhance the strong-field induced emission of highly charged atomic ions from silver clusters embedded in helium nanodroplets. With light fields shaped in amplitude and phase we observe a substantial increase of the Ag{sup q+} yield for q>10 when compared to bandwidth-limited and optimally stretched pulses. A remarkably simple double-pulse structure, containing a low-intensity prepulse and a stronger main pulse, turns out to produce the highest atomic charge states up to Ag{sup 20+}. A negative chirp during the main pulse hints at dynamic frequency locking to the cluster plasmon. A numerical optimal control study on pure silver clusters with a nanoplasma model converges to a similar pulse structure and corroborates that the optimal light field adapts to the resonant excitation of cluster surface plasmons for efficient ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Samoa Updater: An Application of the Levenberg-Marquardt Method to Update DELFIC Predictions Using Field Measurements

The US Department of Energy (DOE) Forensics Operations (DFO) is a member of the Ground Collections Task Force (GCTF), which is responsible for sample collection of radiological debris for attribution should a nuclear detonation ever occur in the United States. The DFO runs the Defense Land Fallout Interpretive Code (DELFIC) Fallout Planning Tool to predict the deposition of fallout from a nuclear detonation. This prediction is refined using the DELFIC Updater tool, which takes ground measurements and adjusts DELFIC inputs to minimize the difference between prediction and observation, yielding improved predictions of fallout in locations both measured and not yet measured. Samoa, a framework for uncertainty analysis and optimization, is used to improve DELFIC predictive fallout modeling. This new capability using Samoa, dubbed “Samoa Updater,” is compared with the current DELFIC Updater, a brute-force sampling approach. Samoa Updater uses the Levenberg– Marquardt (LM) method, a gradient-based nonlinear least squares approach that uses the functional shape of the input space to increase optimization speed. In simulated test cases Samoa Updater yields faster and more accurate solutions than the current Updater.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimization of End Cells of Low Beta Cavity of Higher Energy Part of Project X

11 cell elliptical cavity is designed for acceleration of particles travelling at 81 % of the speed of light. It will operate at 1.3 GHz & will be served to accelerate the particles from 0.450 GeV to 1.2 GeV in high energy section of Project-X. The cavity is studied for higher order mode (HOM) & trapped modes. The shapes of end cells of cavity is optimized to increase the field amplitude in end cells so that coupling of trapped modes may increase with HOM coupler & they can be extracted easily but keeping the field flatness & operating frequency undisturbed.

43 PARTICLE ACCELERATORS↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗