Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Single mode variable-sensitivity fiber optic sensors

We review spatially-weighted optical fiber sensors that filter specific vibration modes from one dimensional beams placed in clamped-free and clamped-clamped configurations. The sensitivity of the sensor is varied along the length of the fiber by tapering circular-core, dual-mode optical fibers. Selective vibration mode suppression on the order of 10 dB was obtained. We describe experimental results and propose future extensions to single mode sensor applications.

Murphy, K. A.↗

Report of subpanel on feature extraction

The state of knowledge in feature extraction for Earth resource observation systems is reviewed and research tasks are proposed. Issues in the subpixel feature estimation problem are defined as: (1) the identification of image models which adequately describe the data and the sensor it is using; (2) the construction of local feature models based on those image models; and (3) the problem of trying to understand these effects of preprocessing on the entire process. The development of ground control point (GCP) libraries for automated selection presents two concerns. One is the organization of these GCP libraries for rectification problems, i.e., the problems of automatically selecting by computer the specific GCP's for particular registration tasks. Second is the importance of integrating ground control patterns in a data base management system, allowing interface to a large number of sensor image types with an automatic selection system. The development of data validation criteria for the comparison of different extraction techniques is also discussed.

Source record↗

MEMS Memory Elements

This paper presents a design example that illustrates the potential of microelectromechanical systems (MEMS) to perform the mechanical positioning required for addressing stored data and to enable an entirely new mechanism for reading and writing magnetic data. Specifically, MEMS sensors and actuators can be used to achieve active servo control of the separation between magnetic probe tips and a media surface with sub-nanometer accuracy. This allows mechanical position to be used to selectively write magnetic marks in a continuous thin-film magnetic media. In addition, MEMS sensors can be used to measure the separation between a magnetic probe tip and the media with a noise floor of roughly 22 picometers, allowing them to be used as position sensors in a magnetic force microscope (MFM) style data detection system.

Carley, L. Richard↗

Visual Image Sensor Organ Replacement: Implementation

Method and system for enhancing or extending visual representation of a selected region of a visual image, where visual representation is interfered with or distorted, by supplementing a visual signal with at least one audio signal having one or more audio signal parameters that represent one or more visual image parameters, such as vertical and/or horizontal location of the region; region brightness; dominant wavelength range of the region; change in a parameter value that characterizes the visual image, with respect to a reference parameter value; and time rate of change in a parameter value that characterizes the visual image. Region dimensions can be changed to emphasize change with time of a visual image parameter.

Maluf, A. David↗

Biochemical Sensors Using Carbon Nanotube Arrays

Method and system for detecting presence of biomolecules in a selected subset, or in each of several selected subsets, in a fluid. Each of an array of two or more carbon nanotubes ("CNTs") is connected at a first CNT end to one or more electronics devices, each of which senses a selected electrochemical signal that is generated when a target biomolecule in the selected subset becomes attached to a functionalized second end of the CNT, which is covalently bonded with a probe molecule. This approach indicates when target biomolecules in the selected subset are present and indicates presence or absence of target biomolecules in two or more selected subsets. Alternatively, presence of absence of an analyte can be detected.

Li, Jun↗

Terra and Aqua MODIS Intercomparison Using LEO-GEO Double Difference Method

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Terra and Aqua satellites havesuccessfully operated since their launch in 1999 and in 2002, providing more than 18 and 16 years ofcontinuous global observations, respectively. The inter-comparison between the two MODIS instruments can bevery supportive for the instrument calibration and uncertainty assessment. Aqua and Terra MODIS have almostidentical relative spectral response, spatial resolution, and dynamic range for each band. Therefore, a sitedependent correction for a sensor spectral band pair is not necessary for their comparison. However, Terra is inthe morning orbit with an equator crossing time of 10:30 am, and Aqua is in the afternoon orbit with equatorcrossing time of 1:30 pm. Consequently, there is a dearth of simultaneous nadir overpasses (SNOs)between the two satellites. Major challenges in cross-sensor comparison of instruments on different satellitesinclude differences in observation time, solar angle, and view angle over selected pseudo-invariant sites.In this work, the inter-comparisons of thermal emissive bands are performed over a pseudo-invariant target,using the observations from a sensor onboard a geostationary satellite as a bridge. Himawari8 was launched onOctober 7, 2014. The Advanced Himawari Imager (AHI) onboard Himawari8 can be used as a reference tobridge the comparison between Terra and Aqua MODIS. AHI has 16 channels; with spatial resolutions from 0.5km to 2 km at nadir and produces a full disk observations every 10 minutes. The band spectral coveragematchup, comparable spatial resolution and near-simultaneous observation between MODIS and AHI providefeasibility to implement a double difference method. This comparison method minimizes the impact of thedifference in observation time and solar angle. The comparison results will be used as an assessment for MODISinstrument calibration and will be helpful for future enhancement of the L1B product.

Himawari8↗

Carbon Nanofiber Nanoelectrodes for Biosensing Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

bioinstrumentation↗

Optical fiber voltage sensors for broad temperature ranges

We describe the development of an optical fiber ac voltage sensor for aircraft and spacecraft applications. Among the most difficult specifications to meet for this application is a temperature stability of +/- 1 percent from -65 C to +125 C. This stability requires a careful selection of materials, components, and optical configuration with further compensation using an optical-fiber temperature sensor located near the sensing element. The sensor is a polarimetric design, based on the linear electro-optic effect in bulk Bi4Ge3O12. The temperature sensor is also polarimetric, based on the temperature dependence of the birefringence of bulk SiO2. The temperature sensor output is used to automatically adjust the calibration of the instrument.

Rose, A. H.↗

Inertial Orientation Trackers with Drift Compensation

A class of inertial-sensor systems with drift compensation has been invented for use in measuring the orientations of human heads (and perhaps other, similarly sized objects). These systems can be designed to overcome some of the limitations of prior orientation-measuring systems that are based, variously, on magnetic, optical, mechanical-linkage, and acoustical principles. The orientation signals generated by the systems of this invention could be used for diverse purposes, including controlling head-orientation-dependent virtual reality visual displays or enabling persons whose limbs are paralyzed to control machinery by means of head motions. The inventive concept admits to variations too numerous to describe here, making it necessary to limit this description to a typical system, the selected aspects of which are illustrated in the figure. A set of sensors is mounted on a bracket on a band or a cap that gently but firmly grips the wearer s head to be tracked. Among the sensors are three drift-sensitive rotationrate sensors (e.g., integrated-circuit angular- rate-measuring gyroscopes), which put out DC voltages nominally proportional to the rates of rotation about their sensory axes. These sensors are mounted in mutually orthogonal orientations for measuring rates of rotation about the roll, pitch, and yaw axes of the wearer s head. The outputs of these rate sensors are conditioned and digitized, and the resulting data are fed to an integrator module implemented in software in a digital computer. In the integrator module, the angular-rate signals are jointly integrated by any of several established methods to obtain a set of angles that represent approximately the orientation of the head in an external, inertial coordinate system. Because some drift is always present as a component of an angular position computed by integrating the outputs of angular-rate sensors, the orientation signal is processed further in a drift-compensator software module.

Foxlin, Eric M.↗

Mission requirements for a manned earth observatory. Task 2: Reference mission definition and analyiss, volume 2

The mission requirements and conceptual design of manned earth observatory payloads for the 1980 time period are discussed. Projections of 1980 sensor technology and user data requirements were used to formulate typical basic criteria pertaining to experiments, sensor complements, and reference missions. The subjects discussed are: (1) mission selection and prioritization, (2) baseline mission analysis, (3) earth observation data handling and contingency plans, and (4) analysis of low cost mission definition and rationale.

Source record↗

Skylab program earth resources experiment package: Ground truth data for test sites (SL-2)

Field measurements were performed at selected ground sites in order to provide comparative calibration measurements of sensors for the Earth Resources Experiment Package. Specifically, the solar radiation (400 to 1300 namometers) and thermal radiation (8-14 micrometers) were measured. Sites employed for the thermal measurements consisted of warm and cold water lakes. The thermal brightness temperature of the lake water, the temperature and humidity profile above the lake, and near surface meteorology (wind speed, pressure, etc.) were measured near the time of overpass. Sites employed for the solar radiation measurements were two desert type sites. Ground measurements consisted of: (1) direct solar radiation - optical depth; (2) diffuse solar radiation; (3) total solar radiation, (4) target directional (normal) reflectance; (5) target hemispherical reflectance; and (6) near surface meteorology.

Source record↗

Multispectral determination of soil moisture-2

Soil moisture data obtained using scatterometers, modular multispectral scanners and passive microwave radiometers were revised and grouped into four field cover types for statistical anaysis. Guymon data are grouped as alfalfa, bare, milo with rows perpendicular to the field view, and milo viewed parallel to the field of view. Dalhart data are grouped as bare combo, stubble, disked stubble, and corn field. Summary graphs combine selected analyses to compare the effects of field cover. The analysis for each of the cover types is presented in tables and graphs. Other tables show elementary statistics, correlation matrices, and single variable regressions. Selected eigenvectors and factor analyses are included and the highest correlating sensor typs for each location are summarized.

Estes, J. E.↗

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

Vibration isolation technology experiment

The objectives of the vibration isolation technology experiment are to demonstrate the viability of the magnetic suspension technology in providing the isolation of large structures elements from the external environment and to quantify the degree of isolation provided by this system. The approach proposed for this experiment is to mount a six-degrees-of-freedom magnetic bearing suspension system at the free end of a shuttle-attached flexible structure such as MAST. The disturbance generator, located on top of the isolation system, will be energized at selected and broadband frequencies to simulate a typical spacecraft vibration environment. Sensors located on the isolation system and the flexible structures element will be used to quantify the degree of isolation provided by this system.

Keckler, C. R.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

Improved operation of magnetic bearings for flywheel energy storage system

Analysis and operation of prototype 500-Wh flywheel at low speeds have shown that many factors affect the correct functioning of the magnetic bearings. An examination is made of a number of these, including magnetic bearing control system nonlinearities and displacement transducer positioning, and their effects upon the successful operation of the suspension system. It is observed that the bearing control system is extremely sensitive to actuator parameters such as coil inductance. As a consequence of the analysis of bearing relaxation oscillations, the bearing actuator design methodology which has previously been used, where coil parameter selection is based upon static considerations, has been revised. Displacement transducer sensors which overcome the collocation problem are discussed.

Zmood, R. B.↗

ECLSS predictive monitoring

On Space Station Freedom (SSF), design iterations have made clear the need to keep the sensor complement small. Along with the unprecendented duration of the mission, it is imperative that decisions regarding placement of sensors be carefully examined and justified during the design phase. In the ECLSS Predictive Monitoring task, we are developing AI-based software to enable design engineers to evaluate alternate sensor configurations. Based on techniques from model-based reasoning and information theory, the software tool makes explicit the quantitative tradeoffs among competing sensor placements, and helps designers explore and justify placement decisions. This work is being applied to the Environmental Control and Life Support System (ECLSS) testbed at MSFC to assist design personnel in placing sensors for test purposes to evaluate baseline configurations and ultimately to select advanced life support system technologies for evolutionary SSF.

Doyle, Richard J.↗

Implementation of an intelligent control system

A laboratory testbed facility which was constructed at NASA LeRC for the development of an Intelligent Control System (ICS) for reusable rocket engines is described. The framework of the ICS consists of a hierarchy of various control and diagnostic functions. The traditional high speed, closed-loop controller resides at the lowest level of the ICS hierarchy. Above this level resides the diagnostic functions which identify engine faults. The ICS top level consists of the coordination function which manages the interaction between an expert system and a traditional control system. The purpose of the testbed is to demonstrate the feasibility of the OCS concept by implementing the ICS as the primary controller in a simulation of the Space Shuttle Main Engine (SSME). The functions of the ICS which are implemented in the testbed are as follows: an SSME dynamic simulation with selected fault mode models, a reconfigurable controller, a neural network for sensor validation, a model-based failure detection algorithm, a rule based failure detection algorithm, a diagnostic expert system, an intelligent coordinator, and a user interface which provides a graphical representation of the event occurring within the testbed. The diverse nature of the ICS has led to the development of a distributed architecture consisting of specialized hardware and software for the implementation of the various functions. This testbed is made up of five different computer systems. These individual computers are discussed along with the schemes used to implement the various ICS components. The communication between computers and the timing and synchronization between components are also addressed.

Simon, D. L.↗