Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

Transistor-Based Work-Function Measurement of Metal–Organic Frameworks for Ultra-Low-Power, Rationally Designed Chemical Sensors

A classic challenge in chemical sensing is selectivity. Metal–organic frameworks (MOFs) are an exciting class of materials because they can be tuned for selective chemical adsorption. Adsorption events trigger work-function shifts, which can be detected with a chemical-sensitive field-effect transistor (power ≈microwatts). Here, several case studies were used towards generalizing the sensing mechanism, ultimately towards our metal-centric hypothesis. HKUST-1 was used as a proof-of-principle humidity sensor. The response is thickness independent, meaning the response is surface localized. ZIF-8 is demonstrated to be an NO 2 -sensing material, and the response is dominated by adsorption at metal sites. Finally, MFM-300(In) shows how standard hard–soft acid–base theory can be used to qualitatively predict sensor responses. This paper sets the groundwork for using the tunability of metal–organic frameworks for chemical sensing with distributed, scalable devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

Chemiresistor sensor based on ion-imprinted polymer (IIP)-functionalized rGO for Cd(II) ions in water

This study reports the design and development of a novel chemiresistor (CR) sensor using ion imprinted polymer (IIP)-functionalized reduced graphene oxide (rGO) [IIP/rGO-CR] for cadmium ions (Cd(II)) determination in water. The sensor consisted of a CR transducer made of rGO channel bridging source and drain electrodes prepared by self-assembly and thermal reduction of graphene oxide (GO) on Au interdigitated electrodes chip fabricated on Si/SiO 2 substrate. The IIP was then grafted on rGO using surface-initiated reversible addition-fragmentation chain transfer (RAFT) polymerization with polyethylenimine (PEI) and methylacrylic acid (MAA) as dual functional monomers and Cd(II) ions as template through UV light-initiated copolymerization. The IIP functionalized on rGO acted as an effective recognition element that modulated the resistance of rGO-CR upon binding of Cd(II), enabling Cd(II) detection at ppb level in aqueous solutions. The prepared IIP/rGO-CR sensor worked effectively in the linear range of 2~200ppb and achieved a limit of detection (LOD) of 0.83 ppb, which is lower than the World Health Organization guidelines of 3ppb for drinking water quality. The developed sensor of IIP/rGO-CR showed a high selectivity against a variety of trace and heavy metal ions found in water and good stability for up to 60 days when stored at room temperature for Cd(II) determination in water. Further, the sensor was successfully applied to analyzing Cd(II) spiked in tap, lake and river waters with a 94.5%–113.5% recovery, demonstrating a high degree of accuracy even in complex water samples. Finally, our results illustrated that the CR sensor of IIP functionalized rGO provides a potential platform for sensitive, robust and low-cost environmental analysis of Cd(II) in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development, fabrication and calibration of a porous surface microphone in an aerofoil

The development of a porous surface microphone in an airfoil intended to measure acoustic signals in a turbulent airflow and to minimize the flow noise is described. The sensor because of its airfoil operates over a wide range of yaw angles and flow velocities without excessive flow noise. The acoustic properties of the porous materials used in the airfoil sensor and their effects on the frequency response of the sensor were analyzed and tested. An accurate airfoil was selected, having a smaller thickness-to-chord ratio and an airfoil sensor was designed. The sensor was calibrated acoustically and its flow noise evaluated in the quiet BBN wind tunnel at flow velocities up to 70 m/sec. Results are presented.

Noiseux, D. U.↗

Radiation Budget Instrument (RBI) for JPSS-2

Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES instruments approach. To monitor climate change and to get stable and traceable results, it is critical to assure stable calibration over instrument lifetime.

Georgieva, Elena↗

Developing Model Benchtop Systems for Microbial Experimental Evolution

Understanding how microbes impact an ecosystem has improved through advances of molecular and genetic tools, but creating complex systems that emulate natural biology goes beyond current technology. In fact, many chemical, biological, and metabolic pathways of even model organisms are still poorly characterized. Even then, standard laboratory techniques for testing microbial impact on environmental change can have many drawbacks; they are time-consuming, labor intensive, and are at risk of contamination. By having an automated process, many of these problems can be reduced or even eliminated. We are developing a benchtop system that can run for long periods of time without the need for human intervention, involve multiple environmental stressors at once, perform real-time adjustments of stressor exposure based on current state of the population, and minimize contamination risks. Our prototype device allows operators to generate an analogue of real world micro-scale ecosystems that can be used to model the effects of disruptive environmental change on microbial ecosystems. It comprises of electronics, mechatronics, and fluidics based systems to control, measure, and evaluate the before and after state of microbial cultures from exposure to environmental stressors. Currently, it uses four parallel growth chambers to perform tests on liquid cultures. To measure the population state, optical sensors (LED/photodiode) are used. Its primary selection pressure is UV-C radiation, a well-studied stressor known for its cell- and DNA-damaging effects and as a mutagen. Future work will involve improving the current growth chambers, as well as implementing additional sensors and environmental stressors into the system. Full integration of multiple culture testing will allow inter-culture comparisons. Besides the temperature and OD sensors, other types of sensors can be integrated such as conductivity, biomass, pH, and dissolved gasses such as CO and O. Additional environmental stressor systems like temperature (extreme heat or cold), metal toxicity, and other forms of radiation will increase the scale and testing range.

Developing↗

Carbon dioxide sensor

Analytical techniques for measuring CO2 were evaluated and rated for use with the advanced extravehicular mobility unit. An infrared absorption concept using a dual-wavelength monochromator was selected for investigation. A breadboard carbon dioxide sensor (CDS) was assembled and tested. The CDS performance showed the capability of measuring CO2 over the range of 0 to 4.0 kPa (0 to 30 mmHg) P sub (CO2). The volume and weight of a flight configured CDS should be acceptable. It is recommended that development continue to complete the design of a flight prototype.

Source record↗

Coded acoustic wave sensors and system using time diversity

An apparatus and method for distinguishing between sensors that are to be wirelessly detected is provided. An interrogator device uses different, distinct time delays in the sensing signals when interrogating the sensors. The sensors are provided with different distinct pedestal delays. Sensors that have the same pedestal delay as the delay selected by the interrogator are detected by the interrogator whereas other sensors with different pedestal delays are not sensed. Multiple sensors with a given pedestal delay are provided with different codes so as to be distinguished from one another by the interrogator. The interrogator uses a signal that is transmitted to the sensor and returned by the sensor for combination and integration with the reference signal that has been processed by a function. The sensor may be a surface acoustic wave device having a differential impulse response with a power spectral density consisting of lobes. The power spectral density of the differential response is used to determine the value of the sensed parameter or parameters.

Solie, Leland P.↗

Charge collection during hypervelocity penetrations of thin foils

The following represents trajectory sensor development work for the space-station-based Cosmic Dust Collection Facility (CDCF). This facility-class payload was to expose some 7 sq m of NASA-provided general-user instruments in addition to three instruments provided by formally selected principal investigators. The preferred trajectory sensor for this general-user instrument envisioned the detection of impact-triggered plasma for both velocity measurement and location instruments. Space station developments in late 1992/early 1993 lead to cancellation of this potential flight project, for both technical and fiscal reasons. This precipitated termination of all plasma detection work at JSC on behalf of CDCF's general-user instrument. The following comprises three informal reports that summarize the CDCF efforts regarding plasma sensing for trajectory determinations. The reports were initially written for internal CDCF use and were not widely distributed. Because no formal publications are envisioned at present, the three reports are included in full in this document. They not only demonstrate that substantial progress was accomplished in the development of plasma trajectory sensors during 1990-1992, but the results are hopefully of interest and use to others who may continue these developments. The chronological sequence of these three reports is reversed, with the first containing the latest information.

Peterson, Robert B.↗

Exceptional NH 3 Detection by Cu(cyhdc) MOF Sensor Due to H 2 O Coadsorption

Metal–organic framework (MOF)-based electrical impedance sensors are a growing class of sensors that show utility in the detection of environmentally toxic gases. Detection of trace NH 3 has been particularly difficult to design due to the low electrical response of NH 3 . However, this has been circumvented by judiciously selecting a MOF that has enhanced electrical response to NH 3 due to coadsorption with predominant atmospheric gases such as water. Herein, an MOF Cu(cyhdc) based sensor has been successfully demonstrated for the enhanced detection of environmentally toxic NH 3 gas. The sensor shows a change in impedance when it is exposed to 5 ppm of NH 3 . At 20 °C, >30% relative humidity (RH) is necessary to elicit a change, with the response increasing with RH and reaching 3170× at 92% RH, producing the largest published response to NH 3 for a MOF direct electrical sensor. In the absence of water, no change is observed toward 5 ppm of NH 3 over 20–50 °C. Here, this electrical response is largely driven by huge decreases in the imaginary component of the impedance, attributed to increased capacitance at the surface of the MOF crystallites upon NH 3 and H 2 O coadsorption. Complementary structural and microstructural characterization proves that the Cu(cyhdc) crystalline structure and morphology remain intact under trace NH 3 and/or H 2 O adsorption. Despite extremely low NH 3 , loadings seen in TGA, XPS, and FT-IR confirm NH 3 and H 2 O adsorption, and changes to the metal-carboxylate IR peak positions are observed upon NH 3 adsorption. Concentrated primarily at the outer surfaces of the MOF crystallites, this NH 3 and H 2 O coadsorption effectively increases the surface capacitance across the Cu(cyhdc) powder and enables direct electrical detection of trace NH 3 . Together, these results demonstrate how coadsorption of specific molecules (H 2 O) can be used to enable the electrical detection of trace toxic gases that would otherwise not have produced a MOF sensor response.

ammonia↗

The Effect of Planetary Albedo on Solar Orientation of Spacecraft

The analytical expression for the solar orientation error caused by planetary albedo is derived. A typical solar sensor output characteristic is assumed and a computer solution to the analytical is obtained. The computer results are presented for a spacecraft in the vicinity of Earth, Venus, Mars, and the Moon. Each planetary body is assumed to be a spherical diffuse reflector with cylindrical shadows and a constant albedo. The data generated herein permit the selection of an appropriate coarse-sensor to fine-sensor switching angle for solar orientation control systems and facilitate the the interpretation of solar-referenced scientific experiment data.

SPACE ORIENTATION↗

A Triboelectric Sensor Array for Electrostatic Studies on the Lunar Surface

The moons electrostatic environment requires careful consideration in the development of future lunar landers. Electrostatically charged dust was well documented during the Apollo missions to cause thermal control, mechanical, and visibility issues. The fine dust particles that make up the surface are electrostatically charged as a result of numerous charging mechanisms. The relatively dry conditions on the moon creates a prime tribocharging environment during surface operations. The photoelectric effect is dominant for lunar day static charging, while plasma electrons are the main contributor for lunar night electrostatic effects. Electrostatic charging is also dependent on solar intensity, Earth-moon relative positions, and cosmic ray flux. This leads to a very complex and dynamic electrostatic environment that must be studied for the success of long term lunar missions.In order to better understand the electrostatic environment of planetary bodies, Kennedy Space Center, in previous collaboration with the Jet Propulsion Laboratory, has developed an electrostatic sensor suite. One of the instruments included in this package is the triboelectric sensor array. It is comprised of strategically selected materials that span the triboelectric series and that also have previous spaceflight history. In this presentation, we discuss detailed testing with the triboelectric sensor array performed at Kennedy Space Center. We will discuss potential benefits and use cases of this low mass, low cost sensor package, both for science and for mission success.

Charging↗

Six degrees of freedom vibration isolation using electromagnetic suspension

Experimental data are presented for modeling an electromagnet. Control laws are considered with and without flux feedback and with position and orientation information of the suspended body. Base motion and sensor noise are the principal disturbances. Proper selection of the geometrical operating point minimizes the passive coupling above the bandwidth of the control and filtering can attenuate the high frequency content of sensor noise. Six electromagnets are arranged in a configuration which optimizes the load support and provides control over all six degrees of freedom of the suspended body. The design is based on experimental data generated with a specially designed test facility. Application for suspension of a gravity wave antenna is discussed.

Lee, Sang-Il↗

Software Would Largely Automate Design of Kalman Filter

Embedded Navigation Filter Automatic Designer (ENFAD) is a computer program being developed to automate the most difficult tasks in designing embedded software to implement a Kalman filter in a navigation system. The most difficult tasks are selection of error states of the filter and tuning of filter parameters, which are timeconsuming trial-and-error tasks that require expertise and rarely yield optimum results. An optimum selection of error states and filter parameters depends on navigation-sensor and vehicle characteristics, and on filter processing time. ENFAD would include a simulation module that would incorporate all possible error states with respect to a given set of vehicle and sensor characteristics. The first of two iterative optimization loops would vary the selection of error states until the best filter performance was achieved in Monte Carlo simulations. For a fixed selection of error states, the second loop would vary the filter parameter values until an optimal performance value was obtained. Design constraints would be satisfied in the optimization loops. Users would supply vehicle and sensor test data that would be used to refine digital models in ENFAD. Filter processing time and filter accuracy would be computed by ENFAD.

Chuang, Jason C. H.↗