Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm 2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Design concept for an optimized earth radiation budget sensor

The Earth Radiation Budget Program has the objective to measure and model the terrestrial radiation budget and obtain a better understanding of the climate and its changes. A multisensor, multisatellite system with high and midinclination orbits will be needed for implementing this program. Various approaches for conducting sensing operations have been evaluated. The present investigation considers a method of sampling with a unique multidirectional array mosaic sensor to fulfill the requirements of earth radiation budget measurements. Previous and present generation earth radiation budget (ERB) satellite instruments are discussed, and attention is given to instrument design tradeoffs and the baseline instrument concept.

Carman, S. L.↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multisensor Arrays for Greater Reliability and Accuracy

Arrays of multiple, nominally identical sensors with sensor-output-processing electronic hardware and software are being developed in order to obtain accuracy, reliability, and lifetime greater than those of single sensors. The conceptual basis of this development lies in the statistical behavior of multiple sensors and a multisensor-array (MSA) algorithm that exploits that behavior. In addition, advances in microelectromechanical systems (MEMS) and integrated circuits are exploited. A typical sensor unit according to this concept includes multiple MEMS sensors and sensor-readout circuitry fabricated together on a single chip and packaged compactly with a microprocessor that performs several functions, including execution of the MSA algorithm. In the MSA algorithm, the readings from all the sensors in an array at a given instant of time are compared and the reliability of each sensor is quantified. This comparison of readings and quantification of reliabilities involves the calculation of the ratio between every sensor reading and every other sensor reading, plus calculation of the sum of all such ratios. Then one output reading for the given instant of time is computed as a weighted average of the readings of all the sensors. In this computation, the weight for each sensor is the aforementioned value used to quantify its reliability. In an optional variant of the MSA algorithm that can be implemented easily, a running sum of the reliability value for each sensor at previous time steps as well as at the present time step is used as the weight of the sensor in calculating the weighted average at the present time step. In this variant, the weight of a sensor that continually fails gradually decreases, so that eventually, its influence over the output reading becomes minimal: In effect, the sensor system "learns" which sensors to trust and which not to trust. The MSA algorithm incorporates a criterion for deciding whether there remain enough sensor readings that approximate each other sufficiently closely to constitute a majority for the purpose of quantifying reliability. This criterion is, simply, that if there do not exist at least three sensors having weights greater than a prescribed minimum acceptable value, then the array as a whole is deemed to have failed.

Immer, Christopher↗

Distributed, Intelligent Edge-Sensing for a Smarter Grid

The electric grid is undergoing major transformations and developments resulting in unprecedented levels of volatility, uncertainty, and stress on grid infrastructure. Smart sensors and methods aiding in advanced visibility and situational awareness are key for tackling these issues. In this work, a decentralized architecture is proposed, where sensing, local computation and control capability are embedded in the edge devices, communicating with a set of trusted 'data mules' in a 'delay-tolerant' manner, while functioning autonomously. This system has been designed and implemented as an overall platform – called Global Asset Monitoring, Management and Analytics (GAMMA) Platform intended to provide the backbone for a global array of sensors and actuators. Further, as a building block for advanced current sensing solutions, a smart, low-cost ‘clip-on’ current sensor based on PCB-embedded Rogowski coil has been developed. The sensor hosts a novel signal conditioning stage allowing an 'auto-tuning' feature, resulting in a universal current sensor design for measuring a wide range of currents, including faults for smart grid applications. Finally, the research proposes a method to instrument and monitor key parameters for the most common electric utility asset – the pole-top distribution transformer. The work done in this research enables scalable, edge-intelligent sensing solutions for monitoring grid infrastructure, allowing utility operators to gain advanced visibility in an economical way.

Kulkarni, Shreyas Bhalchandra↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

Prosser, W. H.↗

Performance of a low-parasitic frequency-domain multiplexing readout

Frequency-domain multiplexing is a readout technique for transition-edge sensor bolometer arrays used on modern cosmic microwave background experiments, including the SPT-3G receiver. Here, we present design details and performance measurements for a low-parasitic frequency-domain multiplexing readout. Reducing the parasitic impedance of the connections between cryogenic components provides a path to improve both the crosstalk and noise performance of the readout. Reduced crosstalk will in turn allow higher-multiplexing factors. We have demonstrated a factor of two improvement in parasitic resistance compared to SPT-3G hardware. Reduced parasitics also permits operation of lower-resistance bolometers optimized for improved readout noise performance. We demonstrate that a module in the prototype system has comparable readout noise performance to an SPT-3G module when operated with dark TES bolometers in the laboratory.

frequency-domain multiplexing↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monitoring installation of partially occluded subassemblies in modular construction factories using BIM, ray tracing, and computer vision

Modular and offsite construction methods are being increasingly adopted due to the advantages they offer in terms of project completion time, quality, and energy-efficiency. Despite these advantages, the current state of monitoring systems in modular construction factories highly relies on labor-intensive, subjective, and error-prone observational methods. A large body of research has aimed to automate the monitoring process using an array of sensors, such as IMUs and RFIDs, during the past two decades. Recently, computer vision-based methods have gained increasing interest as a non-intrusive technology to monitor the process inside modular construction factories. However, partial occlusion challenges have impeded their practical application on a large scale. This challenge is specifically important for monitoring the installation of subassemblies since they can obstruct the view of the monitoring camera, especially those that enable long-term monitoring like closed-circuit television (CCTV) fixed-view surveillance cameras. Here, this paper aims to address this challenge by proposing a novel computer vision-based method to monitor the installation of new subassemblies inside modular factories in highly occluded scenes. The proposed methodology identifies the subassemblies in the CCTV video footage using computer vision, analyzes the occlusions using BIM and ray casting techniques, and estimates the progress of assembly by comparing the BIM model with the detected subassemblies in the video. The proposed methodology was successfully validated on surveillance videos captured from a volumetric modular construction factory in the U.S., achieving 93% accuracy in identifying the installation of subassemblies. The results from this research show that the integration of BIM and computer vision is a promising method for monitoring the installation processes inside modular factories under severe occlusion.

97 MATHEMATICS AND COMPUTING↗

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

Quantitative Voltammetry Measurements of High-Concentration Actinides in Molten Chloride Fuel Salts

Molten chloride mixtures containing high concentrations of UCl 3 (i.e., >70 wt%) are candidates for next-generation molten salt reactor (MSR) fuel salts that enable new plant optimization and fuel cycle strategies. MSR licensing, however, is contingent on the development of effective material control and accounting (MC&A) practices for these salts. To close this gap, we have developed an electroanalytical approach that enables accurate in situ measurements of uranium concentrations in these highly loaded fuel salts. This methodology uses a multielectrode array voltammetry sensor combined with digital simulations that account for non-idealities such as uncompensated resistance effects. The theory-based numerical simulations of voltammetry responses yielded correction factors that are agnostic of electrochemical cell geometry and produced consistent voltammetry peak current results when correcting for varying amounts of ohmic resistance. In doing so, we have demonstrated accurate concentration measurements for UCl 3 in LiCl-KCl-UCl 3 across a range of mass fractions between 55 and 72.3 wt% at 550 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AmeriFlux FLUXNET-1F US-xSP NEON Soaproot Saddle (SOAP)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xSP NEON Soaproot Saddle (SOAP). This is the FLUXNET version of the carbon flux data for the site US-xSP NEON Soaproot Saddle (SOAP) produced by applying the standard ONEFlux (1F) software. Site Description - The Soaproot Saddle is a complex terrain of coarse hills, steep slopes and narrow drainages. With an elevation of 3274 - 4537’ this site encompasses 1438 acres of mixed conifer forests that are experiencing high levels of mortality due to native Pine beetles. At the core of this site stands a 171’ tall flux tower that collects physical and chemical properties of atmosphere and related process. Soaproot Saddle also hosts an array of sensor measurements along with field observations collected by highly trained NEON staff. The automated instrument measurements and some of the terrestrial observational safor this field site are colocted with NEON's aquatic site, Upper Big Creek, which is located just north of Soaproot Saddle's site boundaries.

Network), NEON (National Ecological Observatory [N↗

A Data-Driven Framework for Automated Detection of Aircraft-Generated Signals in Seismic Array Data Using Machine Learning

Abstract Ground motions associated with aircraft overflights can cover a significant portion of the seismic data collected by shallowly emplaced seismometers, such as new nodal and Distributed Acoustic Sensing systems. This article describes the first published framework for automated detection of aircraft on single channel and multichannel seismic data. The seismic data are converted to spectrograms in a sliding time window and classified as aircraft or nonaircraft in each window using a deep convolutional neural network trained with analyst-labeled data. A majority voting scheme is used to convert the output from the sequence of sliding time windows onto a decision time sequence for each channel and to combine the binary classifications on the decision time sequences across multiple channels. Precision, recall, and F-score are used to quantify the detection performance of the algorithm on nodal data using fourfold time-series cross validation. By applying our framework to data from the Sage Brush Flats nodal array in Southern California, we provide a benchmark performance and demonstrate the advantage of using an array of sensors.

Geochemistry & Geophysics↗