Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A spectral method for determining the percentage of green herbage material in clipped samples

A laboratory radiometric method for the rapid determination of green and brown vegetation percentages in clipped grass samples has been developed and tested. The method uses red and photographic infrared radiance or reflectance differences between green and brown vegetation. Mixtures of green and brown material were found to have radiances or reflectances proportional to the percentage of green material present. This method may permit the use of rapid green/brown radiometric determinations to replace the tedious hand sorting now generally used. It may also have application in remote sensing of vegetation ground-truth work where the determination of dry green biomass in clipped samples is necessary.

Tucker, C. J.↗

Computational methods for efficient structural reliability and reliability sensitivity analysis

This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.

Wu, Y.-T.↗

A spectral method for determining the percentage of live herbage material in clipped samples

A laboratory spectroradiometric method for the rapid determination of live/dead vegetation percentages from clipped grass samples has been developed and preliminarily tested. The method utilizes the red and photographic infrared reflectance or radiance differences between green vegetation and that of dead vegetation. Mixtures of green and dead material were found to have reflectances or radiances proportional to the percentage of green material present. This method offers the possibility that rapid live/dead spectroradiometric determinations may replace the tedious hand-sorting now generally in use for many situations.

Tucker, C. J.↗

Mars Sample Return orbital rendezvous detection methods

Navigation trades while in pursuit of a rendezvous with a sample capsule in orbit around Mars are described. The rendezvous operation is described in terms of far-field and near-field detection. Passive optical detection is compared with active capsule detection using a radio beacon. Passive methods are, to first order, unconstrained by time while a radio beacon link is time-limited. A possible activity to make use of orbiter plume interactions is explored.

Gustafson, Eric D.↗

A simple and practical wax-encapsulation method for air-sensitive XAS samples

To facilitate X-ray absorption spectroscopy (XAS) measurements of air-sensitive samples, we present a simple method in which materials are encased in common paraffin wax to protect them from air and moisture. We demonstrate the efficacy of this approach using a highly reducing, air- and moisture-sensitive uranium(III) complex, the tris(amide) U[N(SiMe 3 ) 2 ] 3 (1). When finely dispersed in a boron nitride matrix and subsequently encased in inert paraffin wax, samples of 1 remain stable with no visible or spectroscopic degradation after several days under ambient conditions. The viability of this method for XAS measurements was further evaluated across a series of uranium compounds, ranging from uranyl species to highly air- and moisture-sensitive molecular complexes, at the uranium L 3 -edge. Edge energy determinations were highly reproducible (±0.1 eV between replicates) and, where available, showed excellent agreement with literature values. In conclusion, this low-cost, effective, and versatile method offers a viable solution for XAS studies of air-sensitive compounds and materials.

36 MATERIALS SCIENCE↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

Apollo 16 special samples, part B

Information is presented concerning special samples which were collected for specific investigations. The methods of sample collection are described along with fillet and core samples.

Hoerz, F.↗

Numerical Methods for Classical Sampled-System Analysis

SAMSAN provides control-system analyst with self-consistent computer algorithms that support large-order control-system design and evaluation studies. Emphasizes sampled-system analysis. SAMSAN reduces burden on analyst by providing set of algorithms well tested and documented and readily integrated for solving control-system problems.

Frisch, H. P.↗

Monte Carlo Simulations of Crystal Defects in Open Ensembles

Zero- and two-dimensional crystal defects form in open statistical ensembles, such as the grand canonical, that are usually inaccessible with conventional simulation techniques. This longstanding challenge is overcome with a new Hamiltonian Monte Carlo method that samples energy-biased gradual transformations. In conclusion, the method enables free energy calculations for nonideal point defects and the direct prediction of finite-temperature interface structures.

Grain boundaries↗

Method of detecting and counting bacteria in body fluids

A novel method is reported for determining bacterial levels in urine samples, which method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of non-bacterial ATP. After the removal of non-bacterial ATP, the bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay using an enzyme obtained from the firefly.

Chappelle, E. W.↗

Chemical analyses of provided samples

A batch of four samples were received and chemical analysis was performed of the surface and near surface regions of the samples by the surface analysis by laser ionization (SALI) method. The samples included four one-inch diameter optics labeled windows no. PR14 and PR17 and MgF2 mirrors 9-93 PPPC exp. and control DMES 26-92. The analyses emphasized surface contamination or modification. In these studies, pulsed desorption by 355 nm laser light and single-photon ionization (SPI) above the sample by coherent 118 nm radiation (at approximately 5 x 10(exp 5) W/cm(sup 2)) were used, emphasizing organic analysis. For the two windows with an apparent yellowish contaminant film, higher desorption laser power was needed to provide substantial signals, indicating a less volatile contamination than for the two mirrors. Window PR14 and the 9-93 mirror showed more hydrocarbon components than the other two samples. The mass spectra, which show considerable complexity, are discussed in terms of various potential chemical assignments.

Becker, Christopher H.↗

Chemical analyses of provided samples

Two batches of samples were received and chemical analysis was performed of the surface and near surface regions of the samples by the surface analysis by laser ionization (SALI) method. The samples included four one-inch optics and several paint samples. The analyses emphasized surface contamination or modification. In these studies, pulsed sputtering by 7 keV Ar+ and primarily single-photon ionization (SPI) by coherent 118 nm radiation (at approximately 5 x 10(exp 5) W/cm(sup 2) were used. For two of the samples, also multiphoton ionization (MPI) at 266 nm (approximately 5 x 10(exp 11) W/cm(sup 2) was used. Most notable among the results was the silicone contamination on Mg2 mirror 28-92, and that the Long Duration Exposure Facility (LDEF) paint sample had been enriched in K and Na and depleted in Zn, Si, B, and organic compounds relative to the control paint.

Becker, Christopher H.↗

Major Element Analysis of the Target Rocks at Meteor Crater, Arizona

We collected approximately 400 rock chips in continuous vertical profile at Meteor Crater, Arizona, representing, from bottom to top, the Coconino, Toroweap, Kaibab, and Moenkopi Formations to support ongoing compositional analyses of the impact melts and their stratigraphic source depth(s) and other studies at Meteor Crater that depend on the composition of the target rocks. These rock chips were subsequently pooled into 23 samples for compositional analysis by XRF (x ray fluorescence) methods, each sample reflecting a specific stratigraphic "subsection" approximately 5-10 in thick. We determined the modal abundance of quartz, dolomite, and calcite for the entire Kaibab Formation at vertical resolutions of 1-2 meters. The Coconino Formation composes the lower half of the crater cavity. It is an exceptionally pure sandstone. The Toroweap is only two inches thick and compositionally similar to Coconino, therefore, it is not a good compositional marker horizon. The Kaibab Formation is approximately 80 in thick. XRD (x ray diffraction) studies show that the Kaibab Formation is dominated by dolomite and quartz, albeit in highly variable proportions; calcite is a minor phase at best. The Kaibab at Meteor Crater is therefore a sandy dolomite rather than a limestone, consistent with pronounced facies changes in the Permian of SE Arizona over short vertical and horizontal distances. The Moenkopi forms the 12 in thick cap rock and has the highest Al2O3 and FeO concentrations of all target rocks. With several examples, we illustrate how this systematic compositional and modal characterization of the target ideologies may contribute to an understanding of Meteor Crater, such as the depth of its melt zone, and to impact cratering in general, such as the liberation of CO2 from shocked carbonates.

See, Thomas H.↗

Field Scoping Study of Gamma-Ray Measurement of UF 6 Cristillini Samples with CZT and HPGe Detectors

A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF 6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Fluid Induced Elemental and Mineralogy Alterations of Caney Shale

ABSTRACT: Studies were conducted on cores and rock cuttings recovered from two wells drilled in Caney shale in the Southern Oklahoma. Mineralogical compositions of these samples were obtained by X-Ray Diffraction (XRD) measurements using two methods of sample preparation: conventional powder (by crushing and grinding of rock fragments) and spray-drying of micronized rock powder method. Microstructure and microanalysis were acquired by Scanning Electron Microscopy/Energy Dispersive Spectroscopy (SEM/EDS). Batch experiments were then conducted using selected rock samples and fracturing fluid whilst deionized water was used as control sample for fluid/rock interaction. These were conducted at 95°C and ambient pressure for various time periods to assess the geochemical reactivity of the Caney shale. The rock samples were subsequently recovered from fluid, dried and analysis repeated using identical XRD and SEM/EDS measurements, following the same conditions. Preliminary experimental results show rock mineralogical compositions are predominantly quartz with relatively high clay content. The clay minerals are mainly illite. Carbonate content is less than 10% by weight for most samples, with other non-clay minerals pyrite, albite, dolomite, and some apatite. In general, sprayed samples showed more intense peaks and less full width at half maxima (FWHM) relative to conventional rock-powder samples. Post-experimental mineralogical changes were observed in samples with clay portions breaking down to amorphous entities. As expected, dissolution of carbonates (calcite and dolomite) was observed and newly detected dissolution of biogenic micro quartz resulted in formation of amorphous silica. 1.0 INTRODUCTION Formation of sedimentary rocks involves processes where rock sediments are emplaced with fluids starting interactions that persist over long periods. During the lithification process, sediments and fluids react and attain equilibrium state. This equilibrium is disturbed during drilling, completion, hydraulic fracturing and other operations that involve the introduction of engineered fluids into the subsurface. To return to equilibrium, dissolution and precipitation of minerals may occur. These reactions have implications on the petrophysical properties of the reservoir. Whiles dissolution and precipitation of minerals can enhance porosity and permeability, the reverse can also be true. For example, when acidic fluids are introduced into formations with high carbonate contents, carbonate minerals dissolve into solution thus increasing the porosity and permeability of the formation. In contrast, when alkaline fluids with pH above 11 are introduced into an illite-rich shale formation, the rock-fluid interaction leads to de-flocculation of illite platelets causing substantial increase in clay fines migration, consequently significant reduction in permeability (Salles et al., 2008).

Awejori, G.↗

Approaches of comparison for clear-sky radiative fluxes from general circulation models with Earth Radiation Budget Experiment data

In order to compare the clear-sky greenhouse effect and cloud-radiative forcing from general circulation models with Earth Radiation Budget Experiments (ERBE) data, it is necessary to calculate the general circulation model (GCM) clear-sky radiative fluxes in a way consistent with ERBE. This study discusses problems associated with the available methods for clear-sky radiative flux computations in GCMs and proposes a new approach, which uses a statistical relationship between the grid cloud cover and the availability of ERBE clear-sky measurement, established from ERBE pixel data, to sample the model radiative fluxes. Calculations with version 2 of the National Center for Atmospheric Research (NCAR) Community Climate Model using observed sea surface temperature (SST) show good agreement of clear-sky sampling from the proposed method with ERBE sampling. It is also shown that large improvements are achieved in the spatial variability of the model clear-sky radiative fluxes over ocean, with reference to ERBE, by using the new clear-sky sampling method.

Zhang, M. H.↗

Modular system and method for mercury speciation in a fluid sample

Modular Hg analysis devices and methods are described for use in mercury speciation protocols. Modules can be selected and removably connected to one another to specifically target mercury species in a sample so as to accurately determine the presence or quantity of different mercury species in a fluid sample. Modules can include reductants for reducing inorganic mercury to form elemental mercury and amalgamation agents to capture the elemental mercury. Modules can include filters for capture of particulates as well as capture agents, e.g., solid phase extraction agents, for capture of organic mercury species.

Looney, Brian B.↗