Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampled value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Infrared to x-ray spectral energy distributions of high redshift quasars

We have observed 14 quasars with z greater than 2.8 with the ROSAT-PSPC, and detected 12 of them, including the z=4.11 quasar 0000-263. We present the first x-ray spectrum of a radio quiet quasar with z greater than 3, 1946+768. Its x-ray spectrum is consistent with a power law with spectral index alpha(sub E)=1.8(sup +2.1, sub -1.4) and no evidence for absorption in excess of the galactic column (alpha(sub E)=1.00(sup +0.28, sub -0.32) assuming N(sub H)=N(sub H)(Gal)). A Position Sensitive Proportional Counter (PSPC) hardness ratio is used to constrain the x-ray spectral properties of the quasars for which there were less than 100 photons detected. For the radio quiet quasars, (alpha(sub E)) approximately equals 1.2, if one assumes that there is no absorption in excess of the galactic column. We combine the x-ray data with new ground based optical and near-IR spectrophotometry obtained at the Steward 2.3 m and Multiple Mirror Telescope, and data from the literature. The spectral energy distributions are compared to those of low redshift objects. For the radio quiet quasars with z greater than 2.5, the mean (alpha(sub ox)) is approximately 1.8. This is larger than the mean for quasars with z less than 2.5, but consistent with the expected value for quasars with the high optical luminosities of the objects in this sample. For the radio-loud quasars, (alpha(sub ox)) is approximately 1.4, independent of redshift. This is smaller than the expected value for the optically luminous, high redshift objects in this sample, if they are mostly GHz peaked radio sources and hence comparable to steep-spectrum, compact radio sources at lower redshift. Finally, we compare the spectral energy distributions of two representative objects to the predicted spectrum of a thin accretion disk in the Kerr geometry, and discuss the uncertainties in deriving black hole masses and mass accretion rates.

Bechtold, Jill↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Infrared band extinctions and complex refractive indices of crystalline C2H2 and C4H2

Thermal IR absorption intensities are obtained for thin films of crystalline C2H2 and C4H2 at 70 K, and their n and k complex refractive indices are ascertained by separating true film absorption from interface reflection on the basis of an analysis of the transmission spectrum ratio for two sample thicknesses. This method significantly simplifies the n and k iteration process. The n and k values determined in the laboratory will in most cases reproduce a given sample thickness' observed transmission to within + or - 5 percent.

Khanna, R. K.↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Toxicity of pyrolysis products: Influence of experimental conditions - The MSTL/UT and NASA/JSC Procedures

Ten sample materials of various polymeric composition were evaluated for toxicity of pyrolysis products utilizing two significantly different experimental methods, the MSTL/UT and NASA/JSC Procedures. A comparison of the LD(50) values obtained by the two methods for these ten samples did not yield a significant correlation. However, when the samples were ranked in order of increasing toxicity by each method independently, a comparison of their rank order toxicity improved the correlation. Because of interlaboratory variations in pyrolysis/combustion test procedures, it is suggested a series of standard materials be adopted to facilitate interlaboratory comparisons of data on pyrolysis toxicity.

Lawrence, W. H.↗

Comparison of z-known GRBs with the Main Groups of Bright BATSE Events

The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.

Mitrofanov, Igor G.↗

Evolution versus pulsation along the horizontal branch of M15

The study combines the horizontal-branch tracks (HBETs) of Lee and Demarque (1990) with the period/mean density law of pulsation theory in order to account for the observed periods and relative luminosities of 62 RR Lyrae stars in the extreme metal-poor globular cluster M15. These tests were performed for a number of assumed values for the mean luminosity of the M15 RR Lyrae sample and for different assumed boundaries for the pulsational instability strip. It was found that no single set of models could account for all the RR Lyrae periods and luminosities while simultaneously reproducing the observed value for the the ratio of blue to variable stars. The hypothesis that an RR Lyrae sample evolved near helium exhaustion along the HBETs cannot explain the relatively large number of variable stars in M15 is confirmed.

Simon, Norman R.↗

Lunar rock types - The role of plagioclase in non-mare and highland rock types

Some nonmare and highland rock types (14310 type KREEP and very high Al2O3 basalts) have the internal chemical variations expected for a plagioclase-liquid system. The observed Eu variations in these rock types suggest a D(Eu) 1/p of 0.6 to 0.7. The Sr variations suggest a D(Sr) 1/p of about 0.6, with values as low as 0.35 suggested for some materials from sample 14063. Common Apollo 14 KREEP and Apollo 15 KREEP do not show internal Sr, Eu, Al2O3 variations consistent with the D(Eu, Sr) 1/p values derived for 14310 type KREEP. Major element and experimental data indicate that olivine or pyroxene is a large, perhaps dominant, controller of chemical variations within common Apollo 14 KREEP. The application of these distribution coefficients to pure anorthosites like 15415 yields the model dependent conclusion that the silicate liquids with which such anorthosites may have been chemically equilibrated have not yet been analyzed and perhaps not directly sampled.

Hubbard, N. J.↗

Application of Scanning-Imaging X-Ray Microscopy to Fluid Inclusion Candidates in Carbonates of Carbonaceous Chondrites

In order to search for such fluid inclusions in carbonaceous chondrites, a nondestructive technique using x-ray micro-absorption tomography combined with FIB sampling was developed and applied to a carbonaceous chondrite. They found fluid inclusion candidates in calcite grains, which were formed by aqueous alteration. However, they could not determine whether they are really aqueous fluids or merely voids. Phase and absorption contrast images can be simultaneously obtained in 3D by using scanning-imaging x-ray microscopy (SIXM). In refractive index, n=1-sigma+i(beta), in the real part, 1-sigma is the refractive index with decrement, sigma, which is nearly proportional to the density, and the imaginary part, beta, is the extinction coefficient, which is related to the liner attenuation coefficient, mu. Many phases, including water and organic materials as well as minerals, can be identified by SIXM, and this technique has potential availability for Hayabusa-2 sample analysis too. In this study, we examined quantitative performance of d and m values and the spatial resolution in SIXM by using standard materials, and applied this technique to carbonaceous chondrite samples. We used POM ([CH2O]n), silicon, quartz, forsterite, corundum, magnetite and nickel as standard materials for examining the sigma and mu values. A fluid inclusion in terrestrial quartz and bi-valve shell (Atrina vexillum), which are composed of calcite and organic layers with different thickness, were also used for examining the spatial resolution. The Ivuna (CI) and Sutter's Mill (CM) meteorites were used as carbonaceous chondrite samples. Rod- or cube-shaped samples 20-30 micron in size were extracted by using FIB from cross-sectional surfaces of the standard materials or polished thin sections of the chondrites, which was previously observed with SEM. Then, the sample was attached to a thin W-needle and imaged by SIXM system at beamline BL47XU, SPring-8, Japan. The slice thickness was 109.3 nm and the pixel size was mostly 100 nm.

Tsuchiyama, Akira↗

Calibrating the Ordovician Radiation of marine life: implications for Phanerozoic diversity trends

It has long been suspected that trends in global marine biodiversity calibrated for the Phanerozoic may be affected by sampling problems. However, this possibility has not been evaluated definitively, and raw diversity trends are generally accepted at face value in macroevolutionary investigations. Here, we analyze a global-scale sample of fossil occurrences that allows us to determine directly the effects of sample size on the calibration of what is generally thought to be among the most significant global biodiversity increases in the history of life: the Ordovician Radiation. Utilizing a composite database that includes trilobites, brachiopods, and three classes of molluscs, we conduct rarefaction analyses to demonstrate that the diversification trajectory for the Radiation was considerably different than suggested by raw diversity time-series. Our analyses suggest that a substantial portion of the increase recognized in raw diversity depictions for the last three Ordovician epochs (the Llandeilian, Caradocian, and Ashgillian) is a consequence of increased sample size of the preserved and catalogued fossil record. We also use biometric data for a global sample of Ordovician trilobites, along with methods of measuring morphological diversity that are not biased by sample size, to show that morphological diversification in this major clade had leveled off by the Llanvirnian. The discordance between raw diversity depictions and more robust taxonomic and morphological diversity metrics suggests that sampling effects may strongly influence our perception of biodiversity trends throughout the Phanerozoic.

Non-NASA Center↗

Depositional history of core section 74001 - Depth profiles of maturity, FeO, and metal

Samples from every 0.5-cm interval of soil in core section 74001 have been studied by ferromagnetic resonance (FMR) and magnetic techniques. The values of the FMR maturity index show that the 74001 samples are very immature (the index ranges from 0.14 to 0.29 units) and have not seen appreciable, if any, surface exposure since their deposition. In fact, the small amount of fine-grained metal in the 74001 samples is probably not acquired as a result of their exposure to the micrometeoroid flux at the lunar surface. Thus, the black-glass soil of 74001 was deposited very rapidly, probably in a single episode or several closely spaced episodes of lunar fire fountaining. The average concentration of FeO and its standard deviation for all the 74001 samples are 22.5 + or - 0.3 wt.%. Since the FeO concentration is so uniform, no large variations in the major-element chemistry of 74001 are expected, with the possible exception of the volatile elements. The concentration of coarse-grained metal, which is measured magnetically, and its standard deviation are 0.15 + or - 0.01 wt.%. The coarse-grained metal probably precipitated contemporaneously with the silicate and oxide phases in the black-glass droplets.

Morris, R. V.↗

Complex permittivity of lanthanum aluminate in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

Dielectric constants of microwave substrates are required in the design of superconducting microwave circuits at various temperatures. In this paper, the results are reported of a study of the complex permittivity of the newly developed lanthanum aluminate (LaAlO3) substrate, in the 20 to 300 K temperature range at frequencies from 26.5 to 40.0 GHz. The value of the complex permittivity was obtained by measuring the sample scattering parameters using a microwave waveguide technique. It is observed that, while the dielectric constant did not change appreciably with frequency, its value decreased by approximately 14 percent from room temperature to 20 K.

Miranda, F. A.↗

Effects of Ambient High Temperature Exposure on Alumina-Titania High Emittance Surfaces for Solar Dynamic Systems

Solar dynamic (SD) space power systems require durable, high emittance surfaces on a number of critical components, such as heat receiver interior surfaces and parasitic load radiator (PLR) elements. To enhance surface characteristics, an alumina-titania coating has been applied to 500 heat receiver thermal energy containment canisters and the PLR of NASA Lewis Research Center's (LeRC) 2 kW SD ground test demonstrator (GTD). The alumina-titania coating was chosen because it had been found to maintain its high emittance under vacuum (less than or equal to 10(exp -6) torr) at high temperatures (1457 F (827 C)) for an extended period (approximately 2,700 hours). However, preflight verification of SD systems components, such as the PLR require operation at ambient pressure and high temperatures. Therefore, the purpose of this research was to evaluate the durability of the alumina-titania coating at high temperature in air. Fifteen of sixteen alumina-titania coated Incoloy samples were exposed to high temperatures (600 F (316 C) to l500 F (816 C)) for various durations (2 to 32 hours). Samples, were characterized prior to and after heat treatment for reflectance, solar absorptance, room temperature emittance and emittance at 1,200 F (649 C). Samples were also examined to detect physical defects and to determine surface chemistry using optical microscopy, scanning electron microscopy operated with an energy dispersive spectroscopy (EDS) system, and x ray photoelectron spectroscopy (XPS). Visual examination of the heat-treated samples showed a whitening of samples exposed to temperatures of 1,000 F (538 C) and above. Correspondingly, the optical properties of these samples had degraded. A sample exposed to 1,500 F (816 C) for 24 hours had whitened and the thermal emittance at 1,200 F (649 C) had decreased from the non-heat treated value of 0.94 to 0.62. The coating on this sample had become embrittled with spalling off the substrate noticeable at several locations. Based on this research it is recommended that preflight testing of SD components with alumina-titania coatings be restricted to temperatures no greater than 600 F (316 C) in air to avoid optical degradation. Moreover, components with the alumina-titania coating are likely to experience optical property degradation with direct atomic oxygen exposure in space.

deGroh, Kim K.↗

Cosmological parameters and evolution of the galaxy luminosity function

The relationship between the observed distribution of discrete sources of a flux limited sample, the luminosity function of these sources, and the cosmological model is discussed. It is stressed that some assumptions about the form and evolution of the luminosity function must be made in order to determine the cosmological parameters from the observed distribution of sources. Presented is a method to test the validity of these assumptions using the observations. It is shown how, using higher moments of the observed distribution, one can determine, independently of the cosmological model, all parameters of the luminosity function except those describing evolution of the density and the luminosity of the luminosity function. These methods are applied to the sample of approximately 1000 galaxies recently used by Loh and Spillar to determine a value of the cosmological density parameter Omega approx = 1. It is shown that the assumptions made by Loh and Spillar about the luminosity function are inconsistent with the data, and that a self-consistent treatment of the data indicates a lower value of Omega approx = 0.2 and a flatter luminosity function. It should be noted, however, that incompleteness in the sample could cause a flattening of the luminosity function and lower the calculated value of Omega and that uncertainty in the values of these parameters due to random fluctuations is large.

Caditz, David↗

Cosmological parameters and evolution of the galaxy luminosity function

The relationship between the observed distribution of discrete sources of a flux limited sample, the luminosity function of these sources, and the cosmological model is discussed. It is stressed that some assumptions about the form and evolution of the luminosity function must be made in order to determine the cosmological parameters from the observed distribution of sources. Presented is a method to test the validity of these assumptions using the observations. It is shown how, using higher moments of the observed distribution, one can determine, independently of the cosmological model, all parameters of the luminosity function except those describing evolution of the density and the luminosity of the luminosity function. These methods are applied to the sample of approximately 1000 galaxies recently used by Loh and Spillar to determine a value of the cosmological density parameter Omega approx = 1. It is shown that the assumptions made by Loh and Spillar about the luminosity function are inconsistent with the data, and that a self-consistent treatment of the data indicates a lower value of Omega approx = 0.2 and a flatter luminosity function. It should be noted, however, that incompleteness in the sample could cause a flattening of the luminosity function and lower the calculated value of Omega and that uncertainty in the values of these parameters due to random fluctuations is large.

Caditz, David↗

The X-Irradiation of Hydrazine and 1,1- Dimethylhydrazine

Hydrazine and 1,1-dimethylhydrazine were radiolyzed at room temperature by using about 1 gram of liquid or 1/2 to 2 liters of vapor at room-temperature vapor pressure. A tungsten-target X-ray source operating at 300 kilovolts and 6 to 8 milliamperes (0.1 to 1.0 A) was used at intensities of 1 times 10 (sup 2) to 1 times 10 (sup 3) roentgens per minute to give total doses of 4.1 rads to 2.3 times 10 (sup 6) rads. The amounts of decomposition were dependent on total dose and independent of dose rate. In the case of hydrazine vapor, the decomposition was also directly related to surface area. There was a lesser surface effect with liquid hydrazine, but this variable was not studied for 1,1-dimethylhydrazine. The order of decreasing sensitivity to X-radiation is as follows: hydrazine vapor, 1,1-dimethylhydrazine vapor, 1,1-dimethylhydrazine liquid, and hydrazine liquid. The decomposition products of hydrazine were nitrogen, hydrogen, ammonia, and unidentified products. The same products plus methylamine, dimethylamine, and hydrazine were found from the decomposition of 1,1-dimethylhydrazine. In addition, the 1,1-dimethylhydrazine underwent post-irradiation changes. Values for G (number of molecules of sample decomposed per 100 electronvolts of absorbed energy) of the order of 10 (sup 6) suggest that the vapor-phase decompositions are chain reactions.

X-RAY IRRADIATION↗