Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Scalable and efficient learning from crowds with Gaussian processes

Over the last few years, multiply-annotated data has become a very popular source of information. Online platforms such as Amazon Mechanical Turk have revolutionized the labelling process needed for any classification task, sharing the effort between a number of annotators (instead of the classical single expert). This crowdsourcing approach has introduced new challenging problems, such as handling disagreements on the annotated samples or combining the unknown expertise of the annotators. Probabilistic methods, such as Gaussian Processes (GP), have proven successful to model this new crowdsourcing scenario. However, GPs do not scale up well with the training set size, which makes them prohibitive for medium-to-large datasets (beyond 10K training instances). This constitutes a serious limitation for current real-world applications. In this work, we introduce two scalable and efficient GP-based crowdsourcing methods that allow for processing previously-prohibitive datasets. The first one is an efficient and fast approximation to GP with squared exponential (SE) kernel. The second allows for learning a more flexible kernel at the expense of a heavier training (but still scalable to large datasets). Since the latter is not a GP-SE approximation, it can be also considered as a whole new scalable and efficient crowdsourcing method, useful for any dataset size. Both methods use Fourier features and variational inference, can predict the class of new samples, and estimate the expertise of the involved annotators. A complete experimentation compares them with state-of-the-art probabilistic approaches in synthetic and real crowdsourcing datasets of different sizes. Finally, they stand out as the best performing approach for large scale problems. Moreover, the second method is competitive with the current state-of-the-art for small datasets.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A fluorescence XAFS measurement instrument in the soft x-ray region toward observation under operando conditions

X-ray absorption fine structure (XAFS) measurements are widely used for the analysis of electronic structure. Generally, XAFS in the soft X-ray region is measured under vacuum, but chemical structures under vacuum are typically different from those under operando conditions, where chemical species exhibit their function. Here, we developed an XAFS measurement instrument, as a step toward operando fluorescent, which yields XAFS measurement using synchrotron radiation in the soft X-ray region. We applied this method to analyze the local electronic structure of the sulfur atoms in L-cysteine in different pH solutions. In water at pH 7, the hydrogen atom does not dissociate from the thiol (-SH) group in L-cysteine, which forms a structure surrounded by and interacting with water molecules. The XAFS spectrum of L-cysteine in solution was altered by changing the pH. At pH 9, the hydrogen atom dissociated and a thiolate anion was formed. Although the -SH group was oxidized to SO{sub 4}{sup 2−} when L-cysteine was adsorbed on a metal surface and dried, no oxidation was observed in solution. This may be because the water molecules were densely packed and protected the -SH group from oxidation. Our results show that this instrument aimed toward operando fluorescence XAFS measurements in the soft X-ray region is useful for structural analysis of sulfur atoms in organic molecules in air and in solution. The instrument will be applied to the structural analysis of materials containing elements that have absorption edges in soft X-ray region, such as phosphorus and alkali metals (potassium and cesium). It will be also particularly useful for the analysis of samples that are difficult to handle under vacuum and materials that have specific functions in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Results on Dark Matter Substructure from Astrometric Weak Lensing

Low-mass structures of dark matter (DM) are expected to be entirely devoid of light-emitting regions and baryons. Precisely because of this lack of baryonic feedback, small-scale substructures of the Milky Way are a relatively pristine testing ground for discovering aspects of DM microphysics and primordial fluctuations on subgalactic scales. In this work, we report results from the first search for Galactic DM subhalos with time-domain astrometric weak gravitational lensing. The analysis is based on a matched-filter template of local lensing corrections to the proper motion of stars in the Magellanic Clouds. We describe a data analysis pipeline detailing sample selection, background subtraction, and handling outliers and other systematics. For tentative candidate lenses, we identify a signature based on an anomalous parallax template that can unequivocally confirm the presence of a DM lens, opening up prospects for robust discovery potential with full time-series data. We present our constraints on substructure fraction f l ≲5 at 90% CL (and f l ≲2 at 50% CL) for compact lenses with radii r l <1pc, with best sensitivity reached for lens masses M l around 10 7 -10 8 M ⊙ . Parametric improvements are expected with future astrometric data sets; by end of mission, Gaia could reach f l ≲10 -3 for these massive point-like objects, and be sensitive to lighter and/or more extended subhalos for O(1) substructure fractions.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of CST Post-Processing AP-105 Hanford Tank Waste

The primary goal of the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions, LLC (WRPS), is to remove entrained solids and 137 Cs from the Hanford tank waste supernate to expedite production of low-activity waste. Ion exchange (IX) testing of 10.9 L of waste from Hanford tank 241-AP-105 (AP-105), performed by Pacific Northwest National Laboratory, used a lead-lag-polish column format, with a bed volume of 10 mL per column, to decontaminate tank waste supernate using crystalline silicotitanate (CST) as the IX media. The AP-105 Cs IX processing test, discussed elsewhere, resulted in a shorter transition zone (i.e., steeper load curve) than those defined by wastes from tanks 241-AP-107 and 241-AW-102.1 The shorter transition zone was indicative of a matrix effect retarding Cs capacity. Therefore, aliquots of spent CST from the lead, lag, and polish columns were subjected to a digestion protocol to quantify analytes retained by the CST and extrapolate the impact on Cs capacity. The spent CST was digested using a combination of 5 M HNO 3 and H 2 O 2 with vigorous heating and stirring. Due to the radiation dose accompanying the 137 Cs on the CST columns, a secondary Cs separation by ammonium molybdophosphate embedded in polyacrylonitrile (AMP-PAN) was performed to separate the 137 Cs from the CST so the samples could be contact-handled for analysis outside of a shielded facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geant4 Event Biasing and Fast Simulation

Geant4 offers advanced event biasing techniques to significantly accelerate simulations involving rare events. Various biasing methods, such as leading particle selection, cross-section biasing, radioactive decay enhancement, and bremsstrahlung splitting, enable efficient event sampling, though they require careful handling. Additionally, Geant4 provides a Fast Simulation Interface, allowing the replacement of standard processes in specific region and for selected particles, enabling faster execution or external code integration. Applications of fast simulation include electromagnetic shower modeling in calorimeters, machine learning inference, and offloading tasks to specialized hardware like GPUs, making Geant4 a powerful tool for computationally demanding simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system]

Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.

42 ENGINEERING↗

Introducing controlled matter into a fluid system

Device consisting of capsule holder and glass inner tube has been developed to handle controlled particulate-contamination samples. Premeasured quantity of particles can be injected into closed fluid system without contamination.

Hoffman, C. E.↗

Multivariate-normality goodness-of-fit tests

Computer program applies chi-square Pearson test to multivariate statistics for application in any field in which data of two or more variables (dimensions) are sampled for statistical purposes. Program handles dimensions two through five, with up to thousand data sets.

Falls, L. W.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

SAVLOC, computer program for automatic control and analysis of X-ray fluorescence experiments

A program for a PDP-15 computer is presented which provides for control and analysis of trace element determinations by using X-ray fluorescence. The program simultaneously handles data accumulation for one sample and analysis of data from previous samples. Data accumulation consists of sample changing, timing, and data storage. Analysis requires the locating of peaks in X-ray spectra, determination of intensities of peaks, identification of origins of peaks, and determination of a real density of the element responsible for each peak. The program may be run in either a manual (supervised) mode or an automatic (unsupervised) mode.

Leonard, R. F.↗

Proton irradiation of simple gas mixtures: Influence of irradiation parameters

In order to get information about the influence of irradiation parameters on radiolysis processes of astrophysical interest, methane gas targets were irradiated with 6.5 MeV protons at a pressure of 1 bar and room temperature. Yields of higher hydrocarbons like ethane or propane were found by analysis of irradiated gas samples using gas chromatography. The handling of the proton beam was of great experimental importance for determining the irradiation parameters. In a series of experiments current density of the proton beam and total absorbed energy were shown to have a large influence on the yields of produced hydrocarbons. Mechanistic interpretations of the results are given and conclusions are drawn with regard to the chemistry and the simulation of various astrophysical systems.

Sack, Norbert J.↗

Use of microgravity to improve the efficiency and power output of Nd-doped laser glasses

The objectives of this research are to: (1) obtain further evidence and understand the science for the reported improvement in chemical homogeneity in glasses prepared in microgravity; and (2) study the feasibility of improving the optical and fluorescence properties, particularly, the limit for Nd(+3) concentration quenching and threshold energy for laser action for laser glasses prepared in microgravity. Attention was directed to ground based investigation whose primary purpose was to determine the suitability and conditions for processing these laser glasses in space. This report describes that the scientific and technical information required for planning flight experiments for these glasses have been obtained, and the preparation for handling and analyzing post flight samples have also been taken. Instruments required for measuring the fluorescence properties of interest have been constructed. The optical and fluorescence properties for the glasses have been measured and made available for comparative property analysis.

Ray, Chandra S.↗

Upfront Update on Barsebaeck 1-2 Reactor Internals Segmentation Project - 17382

Westinghouse is currently executing a contract, awarded in June 2015 from Barsebaeck Kraft AB, to segment all the reactor vessel (RV) internal parts in the two units 1 and 2. The scope of work covers the dismantling and segmentation of the RV internals under water, including the upfront engineering studies and equipment manufacturing and qualification. It also includes the loading of the segmented parts into waste cassettes, handling the cassettes, reactor internals sampling (73 samples), complementary water filtration system to catch the segmentation chips and contribute to maintaining water clarity during the segmentation work. Before leaving the site, the pool environment must be restored to the initial condition and all equipment will be decontaminated and shipped off site. The site work started in August 2016 with the mobilization on the Unit 2 and the actual cutting of the first component (steam dryer) started in September. Cutting will be performed with different types of Westinghouse designed cutting equipment. This paper presents the conceptual design of the reactor internals segmentation and packaging process that will be implemented at Barsebaeck, including the planning, methodology, equipment, waste management and packaging strategy. A first feedback on the site work will be provided for the segmentation of the Unit 2 reactor internals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interchange for Joint Research Entitled: Miniature Laser Spectrometer for Stable Isotope Measurements

As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists. A small stable isotope laser spectrometer with a 10 cm path gas cell was designed and constructed. The cell was integrated with a liquid nitrogen cooled tunable diode laser and indium antimonide detector for evaluation. Using the small gas cell, preliminary measurements of 13C/12C in CO2 were made employing single-beam sequential acquisitions of the required spectral data. The results indicate an accuracy of 0.1% which is sufficiently high to make meaningful measurements of martian samples. In addition, improvements in the spectrometer gas handling system have been made to markedly reduce C-13/C-12 isotopic fractionation during sample gas cell loading which we expect will lead to further improvements in precision and accuracy. An important part of making isotopic ratio measurements in solid samples using diode lasers is the conversion of the elements of interest to molecules that have absorption spectra in the mid-ir spectral range accessible by tunable diode lasers. In this project we have investigated the necessary sample preparation procedures to extract carbon, an element of astrobiological importance, from model soil compounds and to convert it to CO2, a molecule with appropriate optical absorption characteristics for reliable laser spectrometer isotopic ratio measurements of 13C/12C. We have considered calcium carbonate as a model for a component of the martian regolith, and we have formulated a simple heating protocol for extracting carbon in the form of CO2.

Becker, J. F.↗

A Description of the XML "Dump Today's Collections" File Format of the BioWatch SMS Console (V.2.0.9)

The BioWatch Sample Management System is a software application to track the handling and history of holders, magazines, and Integrated Bio Aerosol Smart Sample cartridges for air sampling equipment. The user can generate a report in XML format for use by other software applications. This report documents the format of that XML report for Portable Sampling Units. In this version of the XML file, there are no longer any Storage or Archived elements. Also, the Received element for the PSU collector is now named Receive.

99 GENERAL AND MISCELLANEOUS↗

Analysis of lunar samples for carbon compounds.

Description of one approach to the analysis for carbon compounds in lunar materials from the Apollo 11 mission. The sequential scheme followed generally accepted organic geochemical practices, but was unusual in its application to a single sample. The procedures of the scheme were designed to minimize handling of the solids and extracts or hydrolysates. The solid lunar sample was retained in all steps of the sequential analysis in the vessel in which it was originally placed. Centrifugation was used to separate solid and liquid phases after extraction or refluxing. Liquids were recovered from solids by decantation.

Kvenvolden, K. A.↗

Development of a Trace Detection Method for Mercury Speciation in Hanford Tank Waste - 19014

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington State stores 56 million gallons of chemical and radioactive waste stored in underground tanks. Mercury species in liquid and solid fractions of Hanford tank waste pose a risk to the implementation and execution of DoE's River Protection Project mission due to mercury concentration limits imposed under waste acceptance criteria, toxicity characteristic leaching procedure restrictions for secondary waste disposal, and air emission permits. Although there is currently no processing of tank waste at Hanford, waste processing is imminent, and representative mercury inventory tracking will be important to anticipate and mitigate stack emissions and secondary liquid waste disposal issues. A methodology to accurately determine total mercury and mercury speciation in Hanford tank waste, while maintaining low mercury detection limits, currently does not exist at Hanford. Moreover, the mercury species in the waste solids are unknown and may be waste type-specific. The development of an analytical method to separate and speciate mercury in tank waste was undertaken by the Pacific Northwest National Laboratory (PNNL) while leveraging an existing non-radiological, ultra-trace mercury detection technique frequently performed at PNNL's Marine Sciences Laboratory in Sequim, Washington. The ultimate goal of this work is to develop an analytical method to obtain detailed mercury speciation information and update flowsheet modeling assumptions related to mercury partitioning at Hanford. The first phase of testing was completed in the development of an analytical methodology for the low-level determination of total mercury, elemental mercury, methylmercury, and dimethylmercury in Hanford tank waste. This paper presents Phase I testing which focused on determining whether mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid substrate, while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the separation and preconcentration of total mercury and methylmercury onto solid substrates, then measuring the substrates for radiological content at PNNL's Radiochemical Processing Laboratory on the Hanford Site. The mercury content was successfully separated onto stable substrates and the radionuclide activity reduction was significant enough that the preconcentrated samples could be subjected to quantification using far less restrictive handling and radiological controls than would be required for the parent sample (i.e., contamination area fume hood vs. hot cell). This mercury separation method required no sample dilution, which enables maximum mercury detectability, while still allowing mercury speciation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗