Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Future Food Production System Development Pulling From Space Biology Crop Growth Testing in Veggie

Preliminary crop testing using Veggie indicates the environmental conditions provided by the ISS are generally suitable for food crop production. When plant samples were returned to Earth for analysis, their levels of nutrients were comparable to Earth-grown ground controls. Veggie-grown produce food safety microbiology analysis indicated that space-grown crops are safe to consume. Produce sanitizing wipes were used on-orbit to further reduce risk of foodborne illness. Validation growth tests indicated abiotic challenges of insufficient or excess fluid delivery, potentially reduced air flow leading to excess water, elevated CO2 leading to physiological responses, and microorganisms that became opportunistic pathogens. As NASA works to develop future space food production, several areas of research to define these systems pull from the Veggie technology validation tests. Research into effective, reusable water delivery and water recovery methods for future food production systems arises from abiotic challenges observed. Additionally, impacts of elevated CO2 and refinement of fertilizer and light recipes for crops needs to be assessed. Biotic pulls include methods or technologies to effectively sanitize produce with few consumables and low inputs; work to understand the phytomicrobiome and potentially use it to protect crops or enhance growth; selection of crops with high harvest index and desirable flavors for supplemental nutrition; crops that provide psychosocial benefits, and custom space crop development. Planning for future food production in a deep space gateway or a deep space transit vehicle requires methods of handling and storing seeds, and ensuring space seeds are free of contaminants and long-lived. Space food production systems may require mechanization and autonomous operation, with preliminary testing initiated to identify operations and capabilities that are candidates for automation. Food production design is also pulling from Veggie logistics lessons, as we learn about growing at different scales and move toward developing systems that require less launch mass. Veggie will be used as a test bed for novel food production technologies. Veggie is a relatively simple precursor food production system but the knowledge gained from space biology validation tests in Veggie will have far reaching repercussions on future exploration food production. This work is supported by NASA.

Plants↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooperative response of magnetism and superconductivity in the magnetic superconductor RbEuFe 4 As 4

Herein, we present a study of the magnetic-flux evolution in the magnetic superconductor RbEuFe 4 As 4 performed using magneto-optical imaging and magnetization measurements during field cooling and warming and magnetic field cycling at temperatures above and below the magnetic transition point, T$_m$. The vortex patterns emerging at T ≲ T$_m$ reveal that the Eu-spin subsystem serves as an internal pump of the magnetic flux while the superconducting critical current controls the delivery of magnetic-flux quanta into the bulk. The interplay of magnetic susceptibility amplifying the magnetic induction and vortex pinning attenuating the magnetic-flux entry results in a field- and temperature-dependent critical state that emulates a paramagnetic Meissner effect. The observed vortex dynamics corresponds to a nontrivial spatial current distribution and yields a self-consistent inhomogeneous enhancement of the sample magnetization.

36 MATERIALS SCIENCE↗

Machine Learning of Performance Space Mapping for the DPD Simulation of Drug Delivery to Endothelial Cells

Despite huge effort over the years, the design of functionalised nanocarriers (NCs) for targeted drug delivery to endothelial cells is still to be completely unveiled. Dissipative particle dynamics (DPD) simulation is used to study the adhesion of NCs to endothelial cells under the influence of series of parameters such as shape, size, and ligand density of the NCs. However, preparing a performance space mapping that illustrates the penetration depths of NCs as a function of variations in their properties requires simulations of all possible NCs with the above-mentioned properties, which is not feasible. This challenge was addressed by leveraging a Gaussian process regression (GPR)-informed active learning strategy and an extensive exploration of numerous samples, each representing different properties of NCs. The performance space mapping reveals that NCs with rod and disc shapes exhibit superior penetration capabilities compared to those with a spherical shape. Furthermore, it demonstrates that smaller-sized rod-shaped NCs and larger-sized disc-shaped NCs tend to achieve better penetration. When considering smaller NCs, the influence of ligand density appears to be limited. On the contrary, for larger NCs, an increase in ligand density correlates with greater penetration depth, underscoring its substantial role in shaping their penetration capabilities.

36 MATERIALS SCIENCE↗

Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery

Cyberknife (Accuracy Inc., Ca) is a robotic radio-surgery system that includes a compact 6 MV linac delivering up to 800 cGy per minute, and an automate arm to aim at any part of the body from any angle. An essential tool is the guidance system based on x-ray imaging cameras located on supports around the patient. A Cyberknife system has been operational at the Vicenza (Italy) Hospital for years and is mainly employed for treating benign and malignant tumors, and Arterior-Venous Malformations. In radiation therapy, delivery of high doses to targets that move with respiration is challenging because of possible spatial inaccuracies. The purpose of this work was to estimate the accuracy of the prediction algorithm used to compensate for system latency in a real-time respiratory tracking system. We have analyzed respiratory signals of 30 patients who had lung or liver Cyberknife treatments. The 'Synchrony'(Accuracy Inc.) motion tracking system we use is based on the correlation between the position of LED markers, detected in real time, and the position of internal markers, sampled through x-ray imaging. The position of the external LED signals, though read in real time, must be predicted to compensate for a few hundred ms time lag in the feedback loop that redirects the beam to the current target position. The respiratory signals were described by employing their frequency power spectrum, as recently proposed by other authors. Prediction errors above 1.5 mm, lasting for periods longer than 5 seconds were observed for irregular breathers. These episodes correlate to the presence of a bimodal distribution in the power spectral density, and of very low frequencies contribution. A more refined approach would include a personalized choice of the prediction algorithm based on the very first minutes of treatment. Patient training aimed at reducing breathing irregularities might also result in improved spatial accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single Administration of p 2TA (AB103), a CD28 Antagonist Peptide, Prevents Inflammatory and Thrombotic Reactions and Protects against Gastrointestinal Injury in Total-Body Irradiated Mice

The goal of this study was to elucidate the action of the CD28 mimetic peptide p2TA (AB103) that attenuates an excessive inflammatory response in mitigating radiation-induced inflammatory injuries. BALB/c and A/J mice were divided into four groups: Control (C), Peptide (P; 5 mg/kg of p2TA peptide), Radiation (R; total body irradiation with 8 Gy c-rays), and Radiation + Peptide (RP; irradiation followed by p2TA peptide 24 h later). Gastrointestinal tissue damage was evaluated by analysis of jejunum histopathology and immunohistochemistry for cell proliferation (Cyclin D1) and inflammation (COX-2) markers, as well as the presence of macrophages (F4/80). Pro-inflammatory cytokines IL-6 and KC as well as fibrinogen were quantified in plasma samples obtained from the same mice. Our results demonstrated that administration of p2TA peptide significantly reduced the irradiation-induced increase of IL-6 and fibrinogen in plasma 7 days after exposure. Seven days after total body irradiation with 8 Gy of gamma rays numbers of intestinal crypt cells were reduced and villi were shorter in irradiated animals compared to the controls. The p2TA peptide delivery 24 h after irradiation led to improved morphology of villi and crypts, increased Cyclin D1 expression, decreased COX-2 staining and decreased numbers of macrophages in small intestine of irradiated mice. Our study suggests that attenuation of CD28 signaling is a promising therapeutic approach for mitigation of radiation-induced tissue injury.

13 HYDRO ENERGY↗

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗

Meteoric 10Be Flux Calibration Data for the East River Watershed, Colorado, USA

This data package contains tabular and geospatial data used to quantify and model meteoric beryllium-10 fluxes in the East River watershed, Colorado, USA. The tabular component includes calibration-site data from five glacial moraine sites and includes environmental variables used to evaluate spatial controls on meteoric 10Be delivery, including elevation, mean annual precipitation (MAP), mean snow depth, and mean snow water equivalent (SWE). These site-level data were used to compare observed fluxes with environmental gradients across the watershed and to evaluate the effects of erosion correction on flux estimates. The package also includes supporting slope and curvature values used to assess topographic inputs to the erosion analysis. A second component of the data package contains updated manuscript tables and regression outputs used to summarize the relationships between meteoric 10Be flux and environmental predictors. These tables include meteoric 10Be sample information and AMS results, site-level environmental values, site-level meteoric 10Be inventory and flux values, watershed-averaged predicted fluxes, soil bulk density measurements, fine-fraction values, soil pH measurements, and regression statistics including slope, intercept, coefficient of determination, and p-value. The regression products include both standard linear regressions and regressions in which the intercept is constrained to pass through zero, and they support the analyses presented in the companion manuscript. Together, these tabular files provide the numerical basis for the manuscript tables and the regression-based interpretation of meteoric 10Be flux variability in a snow-dominated mountain watershed. The geospatial component of the package consists of GeoTIFF raster files used to generate the map products presented in Figures 2 and 6 of the companion manuscript. These rasters represent watershed-scale spatial layers for environmental variables and regression-based predictions of meteoric 10Be flux. This dataset contains comma-separated values files (.csv), Microsoft Excel files (.xlsx), GeoTIFF raster files (.tif), and upporting metadata files, including CSV data dictionaries and readme text files (.csv, .txt). The tabular files can be opened with standard spreadsheet software, and the raster files can be viewed and analyzed in GIS software such as ArcGIS Pro or QGIS. Together, these files document the numerical and spatial datasets used to calibrate and predict meteoric 10Be delivery in the East River watershed.

East River↗

Spatiotemporal Controls on the Delivery of Dissolved Organic Matter to Streams Following a Wildfire

Warmer and drier climate has contributed to increased occurrence of large, high severity wildfires in the Pacific Northwest, drawing concerns for water quality and ecosystem recovery. While nutrient fluxes generally increase post-fire, the composition of organic matter (OM) transported to streams immediately following a fire is poorly constrained, yet can play an integral role in downstream water quality and biogeochemistry. Here, we quantified the spatiotemporal patterns of dissolved OM (DOM) chemistry for five streams burned by wildfires in Oregon, USA in 2020. We sampled over a 24-hour storm event one month after the fire, revealing variable temporal behavior in DOM dynamics. DOM chemistry was directly related with burn severity spatially. Specifically, nitrogen and aromatic character of DOM increased in streams burned at greater severity. Our results suggest a spatial overprinting of DOM dynamics immediately following fire activity and highlight a key gap in our knowledge of post-fire DOM transport to streams.

54 ENVIRONMENTAL SCIENCES↗

Pressure-Sensitive Adhesive Combined with Paper Spray Mass Spectrometry for Low-Cost Collection and Analysis of Drug Residues

Illicit drug use causes over half a million deaths worldwide every year. Drugs of abuse are commonly smuggled through customs and border checkpoints and, increasingly, through parcel delivery services. Improved methods for detection of trace drug residues from surfaces are needed. Such methods should be robust, fieldable, sensitive, and capable of detecting a wide range of drugs. In this work, commercially produced paper with a pressure-sensitive adhesive coating was utilized for the collection and analysis of trace drug residues by paper spray mass spectrometry (MS). This modified substrate was used to combine sample collection of drug residues from surfaces with rapid detection using a single paper spray ticket. The all-in-one ticket was used to probe different surfaces commonly encountered in forensic work including clothing, cardboard, glass, concrete, asphalt, and aluminum. A total of 10 drugs (acetyl fentanyl, fentanyl, clonazolam, cocaine, heroin, ketamine, methamphetamine, methylone, U-47700, and XLR-11) were evaluated and found to be detectable in the picogram range using a benchtop mass spectrometer and in the low nanogram range using a portable ion trap MS. Finally, the novel approach demonstrates a simple yet effective sampling strategy, allowing for rapid identification from difficult surfaces via paper spray mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric quality assurance prior to MERT application.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-02: Feasibility of Optimization for Dynamic Trajectory Radiotherapy

Purpose: Over the last years, volumetric modulated arc therapy (VMAT) has been widely introduced into clinical routine using a coplanar delivery technique. However, VMAT might be improved by including dynamic couch and collimator rotations, leading to dynamic trajectory radiotherapy (DTRT). In this work the feasibility and the potential benefit of DTRT was investigated. Methods: A general framework for the optimization was developed using the Eclipse Scripting Research Application Programming Interface (ESRAPI). Based on contoured target and organs at risk (OARs), the structures are extracted using the ESRAPI. Sampling potential beam directions, regularly distributed on a sphere using a Fibanocci-lattice, the fractional volume-overlap of each OAR and the target is determined and used to establish dynamic gantry-couch movements. Then, for each gantry-couch track the most suitable collimator angle is determined for each control point by optimizing the area between the MLC leaves and the target contour. The resulting dynamic trajectories are used as input to perform the optimization using a research version of the VMAT optimization algorithm and the ESRAPI. The feasibility of this procedure was tested for a clinically motivated head and neck case. Resulting dose distributions for the VMAT plan and for the dynamic trajectory treatment plan were compared based on DVH-parameters. Results: While the DVH for the target is virtually preserved, improvements in maximum dose for the DTRT plan were achieved for all OARs except for the inner-ear, where maximum dose remains the same. The major improvements in maximum dose were 6.5% of the prescribed dose (66 Gy) for the parotid and 5.5% for the myelon and the eye. Conclusion: The result of this work suggests that DTRT has a great potential to reduce dose to OARs with similar target coverage when compared to conventional VMAT treatment plans. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Public expectations of and responses to WEA message content

Risk communication is crucial to building resilient communities because it allows multi-directional information exchange about a hazard event and its associated risks among stakeholders, and it seeks to promote protective behavior among at-risk populations. Public response to alerts and warnings and inclination to take protective action, however, are influenced by several factors, including message content and style (accuracy, consistency, and clarity), message source and frequency of delivery, language and technologies used for dissemination, and the socio-psychological characteristics of message recipients. Using the Protective Action Decision Model (PADM), this chapter examines the role of language preference of at-risk individuals on their response to alerts received from authoritative sources (i.e., Wireless Emergency Alert (WEA) messages) and via Online Social Networks (OSN) (i.e., social media). An analysis of survey responses of a sample of residents of the Mississippi Gulf Coast was conducted to determine the (1) socioeconomic characteristics influencing public response to warnings – specifically, response to evacuation notice; and (2) role of language preference on public use of specific communication channel. The southeastern United States is home to diverse ethnic and sociocultural communities whose first language is not English. The results of this study provide evidence that will contribute to efforts to make risk communication more inclusive of greater segments of society, ensure integration of local knowledge, and contextualize messages to promote more effective public response.

Kar, Bandana↗

Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback payload based Micromissions, it is essential to implement an even broader chemical analysis and to enable a significant extension of previous isotope measurements. Such a development would enhance the presently very active study of questions of atmospheric evolution and loss and past climatic conditions. The method selected to implement this program can be based on well-established mass spectrometry techniques. Sampled gas is chemically and physically processed to separate the gas mixture into components using gas chromatograph and related enrichment techniques. This allows trace species to be identified and reveals isotopic distributions in many cases with improved precision. Samples of interest, such as organic molecules, may lie deep below the highly oxidized surface layer and the suggested program includes enhanced sampling techniques to measure volatiles preserved in solid phase material deep below the surface as well as gas from the well mixed atmosphere.

Mahaffy, P.↗

Cover Drive and Lock Ring Mechanisms for Genesis

The Genesis payload canister will return solar wind samples to Earth. The canister contains four mechanism assemblies: the Cover Drive Mechanism, the Lock Ring Mechanism, the Array Deployment Mechanism, and the Array Latch Mechanism. The Cover Drive and Lock Ring Mechanisms are described in detail while the other two mechanisms are briefly summarized. The Engineering Model canister has been designed, built, tested, and delivered to the spacecraft. The Flight Model is currently being built with delivery to the spacecraft scheduled for mid July 2000. Launch is scheduled for January 2001

Jandura, Louise↗

Detecting Distance between Injected Microspheres and Target Tumor via 3D Reconstruction of Tissue Sections

One treatment increasing in use for solid tumors in the liver is radioembolization via the delivery of 90Y microspheres to the vascular bed within or near the location of the tumor. It is desirable as part of the treatment for the microspheres to embed preferentially in or near the tumor. This work details an approach for analyzing the deposition of microspheres with respect to the location of the tumor. The approach used is based upon thin-slice serial sectioning of the tissue sample, followed by high resolution imaging, microsphere detection, and 3-D reconstruction of the tumor surface. Distance from the microspheres to the tumor was calculated using a fast deterministic point inclusion method.

Carson, James P.↗

TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

60 APPLIED LIFE SCIENCES↗