Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “salinity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Advanced Systems for Monitoring Underwater Sounds

The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity data acquired by instrumentation systems other than PAMS. A PAMS is packaged as a battery-powered unit, mated with external sensors, that can operate in the ocean at any depth from 2 m to 1 km. A PAMS includes a pressure housing, a deep-sea battery, a hydrophone (which is one of the mating external sensors), and an external monitor and keyboard box. In addition to acoustic transducers, external sensors can include temperature probes and, potentially, underwater cameras. The pressure housing contains a computer that includes a hard drive, DC-to- DC power converters, a post-amplifier board, a sound card, and a universal serial bus (USB) 4-port hub.

Lane, Michael↗

Two-Dimensional Synthetic-Aperture Radiometer

A two-dimensional synthetic-aperture radiometer, now undergoing development, serves as a test bed for demonstrating the potential of aperture synthesis for remote sensing of the Earth, particularly for measuring spatial distributions of soil moisture and ocean-surface salinity. The goal is to use the technology for remote sensing aboard a spacecraft in orbit, but the basic principles of design and operation are applicable to remote sensing from aboard an aircraft, and the prototype of the system under development is designed for operation aboard an aircraft. In aperture synthesis, one utilizes several small antennas in combination with a signal processing in order to obtain resolution that otherwise would require the use of an antenna with a larger aperture (and, hence, potentially more difficult to deploy in space). The principle upon which this system is based is similar to that of Earth-rotation aperture synthesis employed in radio astronomy. In this technology the coherent products (correlations) of signals from pairs of antennas are obtained at different antenna-pair spacings (baselines). The correlation for each baseline yields a sample point in a Fourier transform of the brightness-temperature map of the scene. An image of the scene itself is then reconstructed by inverting the sampled transform. The predecessor of the present two-dimensional synthetic-aperture radiometer is a one-dimensional one, named the Electrically Scanned Thinned Array Radiometer (ESTAR). Operating in the L band, the ESTAR employs aperture synthesis in the cross-track dimension only, while using a conventional antenna for resolution in the along-track dimension. The two-dimensional instrument also operates in the L band to be precise, at a frequency of 1.413 GHz in the frequency band restricted for passive use (no transmission) only. The L band was chosen because (1) the L band represents the long-wavelength end of the remote- sensing spectrum, where the problem of achieving adequate spatial resolution is most critical and (2) imaging airborne instruments that operate in this wavelength range and have adequate spatial resolution are difficult to build and will be needed in future experiments to validate approaches for remote sensing of soil moisture and ocean salinity. The two-dimensional instrument includes a rectangular array of patch antennas arranged in the form of a cross. The ESTAR uses analog correlation for one dimension, whereas the two-dimensional instrument uses digital correlation. In two dimensions, many more correlation pairs are needed and low-power digital correlators suitable for application in spaceborne remote sensing will help enable this technology. The two-dimensional instrument is dual-polarized and, with modification, capable of operating in a polarimetric mode. A flight test of the instrument took place in June 2003 and it participated in soil moisture experiments during the summers of 2003 and 2004.

LeVine, David M.↗

Application of Reflected Global Navigation Satellite System (GNSS-R) Signals in the Estimation of Sea Roughness Effects in Microwave Radiometry

In February-March 2009 NASA JPL conducted an airborne field campaign using the Passive Active L-band System (PALS) and the Ku-band Polarimetric Scatterometer (PolSCAT) collecting measurements of brightness temperature and near surface wind speeds. Flights were conducted over a region of expected high-speed winds in the Atlantic Ocean, for the purposes of algorithm development for salinity retrievals. Wind speeds encountered were in the range of 5 to 25 m/s during the two weeks deployment. The NASA-Langley GPS delay-mapping receiver (DMR) was also flown to collect GPS signals reflected from the ocean surface and generate post-correlation power vs. delay measurements. This data was used to estimate ocean surface roughness and a strong correlation with brightness temperature was found. Initial results suggest that reflected GPS signals, using small low-power instruments, will provide an additional source of data for correcting brightness temperature measurements for the purpose of sea surface salinity retrievals.

Voo, Justin K.↗

Compact Radiometers Expand Climate Knowledge

To gain a better understanding of Earth's water, energy, and carbon cycles, NASA plans to embark on the Soil Moisture Active and Passive mission in 2015. To prepare, Goddard Space Flight Center provided Small Business Innovation Research (SBIR) funding to ProSensing Inc., of Amherst, Massachusetts, to develop a compact ultrastable radiometer for sea surface salinity and soil moisture mapping. ProSensing incorporated small, low-cost, high-performance elements into just a few circuit boards and now offers two lightweight radiometers commercially. Government research agencies, university research groups, and large corporations around the world are using the devices for mapping soil moisture, ocean salinity, and wind speed.

Source record↗

Lessons Learned from Assimilating Altimeter Data into a Coupled General Circulation Model with the GMAO Augmented Ensemble Kalman Filter

Satellite altimetry measurements have provided global, evenly distributed observations of the ocean surface since 1993. However, the difficulties introduced by the presence of model biases and the requirement that data assimilation systems extrapolate the sea surface height (SSH) information to the subsurface in order to estimate the temperature, salinity and currents make it difficult to optimally exploit these measurements. This talk investigates the potential of the altimetry data assimilation once the biases are accounted for with an ad hoc bias estimation scheme. Either steady-state or state-dependent multivariate background-error covariances from an ensemble of model integrations are used to address the problem of extrapolating the information to the sub-surface. The GMAO ocean data assimilation system applied to an ensemble of coupled model instances using the GEOS-5 AGCM coupled to MOM4 is used in the investigation. To model the background error covariances, the system relies on a hybrid ensemble approach in which a small number of dynamically evolved model trajectories is augmented on the one hand with past instances of the state vector along each trajectory and, on the other, with a steady state ensemble of error estimates from a time series of short-term model forecasts. A state-dependent adaptive error-covariance localization and inflation algorithm controls how the SSH information is extrapolated to the sub-surface. A two-step predictor corrector approach is used to assimilate future information. Independent (not-assimilated) temperature and salinity observations from Argo floats are used to validate the assimilation. A two-step projection method in which the system first calculates a SSH increment and then projects this increment vertically onto the temperature, salt and current fields is found to be most effective in reconstructing the sub-surface information. The performance of the system in reconstructing the sub-surface fields is particularly impressive for temperature, but not as satisfactory for salt.

Keppenne, Christian↗

Final Report for Intravenous Fluid Generation (IVGEN) Spaceflight Experiment

NASA designed and operated the Intravenous Fluid Generation (IVGEN) experiment onboard the International Space Station (ISS), Increment 23/24, during May 2010. This hardware was a demonstration experiment to generate intravenous (IV) fluid from ISS Water Processing Assembly (WPA) potable water using a water purification technique and pharmaceutical mixing system. The IVGEN experiment utilizes a deionizing resin bed to remove contaminants from feedstock water to a purity level that meets the standards of the United States Pharmacopeia (USP), the governing body for pharmaceuticals in the United States. The water was then introduced into an IV bag where the fluid was mixed with USP-grade crystalline salt to produce USP normal saline (NS). Inline conductivity sensors quantified the feedstock water quality, output water purity, and NS mixing uniformity. Six 1.5-L bags of purified water were produced. Two of these bags were mixed with sodium chloride to make 0.9 percent NS solution. These two bags were returned to Earth to test for compliance with USP requirements. On-orbit results indicated that all of the experimental success criteria were met with the exception of the salt concentration. Problems with a large air bubble in the first bag of purified water resulted in a slightly concentrated saline solution of 117 percent of the target value of 0.9 g/L. The second bag had an inadequate amount of salt premeasured into the mixing bag resulting in a slightly deficient salt concentration of 93.8 percent of the target value. The USP permits a range from 95 to 105 percent of the target value. The testing plans for improvements for an operational system are also presented.

McQuillen, John B.↗

Digital Receiver for Microwave Radiometry

A receiver proposed for use in L-band microwave radiometry (for measuring soil moisture and sea salinity) would utilize digital signal processing to suppress interfering signals. Heretofore, radio frequency interference has made it necessary to limit such radiometry to a frequency band about 20 MHz wide, centered at .1,413 MHz. The suppression of interference in the proposed receiver would make it possible to expand the frequency band to a width of 100 MHz, thereby making it possible to obtain greater sensitivity and accuracy in measuring moisture and salinity

Ellingson, Steven W.↗

Aquarius and the Aquarius/SAC-D Mission

Aquarius is a combination L-band radiometer and scatterometer designed to map the salinity field at the ocean surface from space. It will be flown on the Aquarius/SAC-D mission, a partnership between the USA space agency (NASA) and Argentine space agency (CONAE). The mission is composed of two parts: (a) The Aquarius instrument being developed as part of NASA.s Earth System Science Pathfinder (ESSP) program; and (b) SAC-D the fourth spacecraft service platform in the CONAE Satellite de Aplicaciones Cientificas (SAC) program. The primary focus of the mission is to monitor the seasonal and interannual variations of the salinity field in the open ocean. The mission also meets the needs of the Argentine space program for monitoring the environment and for hazard detection and includes several instruments related to these goals.

LeVine, D. M.↗

Irrigation Requirement Estimation Using Vegetation Indices and Inverse Biophysical Modeling

We explore an inverse biophysical modeling process forced by satellite and climatological data to quantify irrigation requirements in semi-arid agricultural areas. We constrain the carbon and water cycles modeled under both equilibrium, balance between vegetation and climate, and non-equilibrium, water added through irrigation. We postulate that the degree to which irrigated dry lands vary from equilibrium climate conditions is related to the amount of irrigation. The amount of water required over and above precipitation is considered as an irrigation requirement. For July, results show that spray irrigation resulted in an additional amount of water of 1.3 mm per occurrence with a frequency of 24.6 hours. In contrast, the drip irrigation required only 0.6 mm every 45.6 hours or 46% of that simulated by the spray irrigation. The modeled estimates account for 87% of the total reported irrigation water use, when soil salinity is not important and 66% in saline lands.

Bounoua, Lahouari↗

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions with Climate Data Record Applications

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201 I. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record-provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica-parameters such as surface temperature.

Kim, Edward↗

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201l. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record -- provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica--parameters such as surface temperature.

Kim, Edward↗

Arctic Ocean Freshwater: How Robust are Model Simulations

The Arctic freshwater (FW) has been the focus of many modeling studies, due to the potential impact of Arctic FW on the deep water formation in the North Atlantic. A comparison of the hindcasts from ten ocean-sea ice models shows that the simulation of the Arctic FW budget is quite different in the investigated models. While they agree on the general sink and source terms of the Arctic FW budget, the long-term means as well as the variability of the FW export vary among models. The best model-to-model agreement is found for the interannual and seasonal variability of the solid FW export and the solid FW storage, which also agree well with observations. For the interannual and seasonal variability of the liquid FW export, the agreement among models is better for the Canadian Arctic Archipelago (CAA) than for Fram Strait. The reason for this is that models are more consistent in simulating volume flux anomalies than salinity anomalies and volume-flux anomalies dominate the liquid FW export variability in the CAA but not in Fram Strait. The seasonal cycle of the liquid FW export generally shows a better agreement among models than the interannual variability, and compared to observations the models capture the seasonality of the liquid FW export rather well. In order to improve future simulations of the Arctic FW budget, the simulation of the salinity field needs to be improved, so that model results on the variability of the liquid FW export and storage become more robust.

Jahn, A.↗

IVGEN Post Flight Analysis

The Intravenous Fluid Generation (IVGEN) Experiment was a technology demonstration experiment that purified ISS potable water, mixed it with salt, and transferred it through a sterilizing filter. On-orbit performance was verified as appropriate and two 1.5 l bags of normal saline solution were returned to earth for post-flight testing by a FDA certified laboratory for compliance with United States Pharmacopiea (USP) standards. Salt concentration deviated from required values and an analysis identified probable causes. Current efforts are focused on Total Organic Content (TOC) testing, and shelf life.The Intravenous Fluid Generation (IVGEN) Experiment demonstrated the purification of ISS potable water, the mixing of the purified water with sodium chloride, and sterilization of the solution via membrane filtration. On-orbit performance was monitored where feasible and two 1.5-liter bags of normal saline solution were returned to earth for post-flight testing by a FDA-registered laboratory for compliance with United States Pharmacopeia (USP)standards [1]. Current efforts have been focused on challenge testing with identified [2] impurities (total organic-carbon), and shelf life testing. The challenge testing flowed known concentrations of contaminants through the IVGEN deionizing cartridge and membrane filters to test their effectiveness. One finding was that the filters and DI-resin themselves contribute to the contaminant load during initial startup, suggesting that the first 100 ml of fluid be discarded. Shelf life testing is ongoing and involves periodic testing of stored DI cartridges and membrane filters that are capped and sealed in hermetic packages. The testing is conducted at six month intervals measuring conductivity and endotoxins in the effluent. Currently, the packaging technique has been successfully demonstrated for one year of storage testing. The USP standards specifies that the TOC be conducted at point of generation as opposed to point of consumption. Samples were generated and shipped to an FDA facility however, testing determined that the samples failed the TOC specification with most likely due to leaching from the sample container. Shelf life testing is examining packaging techniques and periodic testing of samples of DI cartridges that are capped and sealed in hermetic packages. Periodic testing of the purified water output will be conducted at six month intervals.

microgravity applications↗

Declining Nutrient Concentrations in the Northeast Atlantic as a Result of a Weakening Subpolar Gyre

Between 1996 and the mid-2000s the upper waters (200-700 m) of the Rockall Trough became warmer (+0.72 C), saltier (+0.088) and reduced in nitrate and phosphate (-2.00 Micron and -0.14 Micron respectively). These changes, out-with calculated errors, can be explained by the varying influence of southern versus subpolar water masses in the basin as the Subpolar Gyre weakened and contracted. Upper water properties strongly correlate with a measure of the strength of the Subpolar Gyre (the first principal component of sea surface height over the Subpolar North Atlantic) prior to the mid-2000s. As the gyre weakens, the upper layers of the trough become warmer (r -0.85), more saline (r -0.86) and reduced in nitrate and phosphate (r +0.81 and r +0.87 respectively). Further the proportion of subpolar waters in the basin decreases from around 50% to less than 20% (r +0. 88). Since the mid-2000s the Subpolar Gyre has been particularly weak. During this period temperatures decreased slightly (-0.21 1C), salinities remained near constant (35.410 +/- 0.005) and phosphate levels low and stable (0.68 +/- 0.02 Micron). These relative lack of changes are thought to be related to the maximum proportion of southern water masses within the Rockall Trough having been reached. Thus the upper water properties are no longer controlled by changes in the relative importance of different water masses in the basin (as prior to the mid-2000s), but rather a different process. We suggest that when the gyre is particularly weak the interannual changes in upper water properties in the Rockall Trough reflect changes in the source properties of the southern water masses. Since the early-2000s the Subpolar Gyre has been weaker than observed since 1992, or modelled since 1960-1970. Hence upper waters within the Rockall Trough may be warmer, saltier and more depleted in nitrate and phosphate than at any time in the last half century.

nutrient↗

North Atlantic Simulations in Coordinated Ocean-Ice Reference Experiments Phase II (CORE-II). Part I: Mean States

Simulation characteristics from eighteen global ocean-sea-ice coupled models are presented with a focus on the mean Atlantic meridional overturning circulation (AMOC) and other related fields in the North Atlantic. These experiments use inter-annually varying atmospheric forcing data sets for the 60-year period from 1948 to 2007 and are performed as contributions to the second phase of the Coordinated Oceanice Reference Experiments (CORE-II). The protocol for conducting such CORE-II experiments is summarized. Despite using the same atmospheric forcing, the solutions show significant differences. As most models also differ from available observations, biases in the Labrador Sea region in upper-ocean potential temperature and salinity distributions, mixed layer depths, and sea-ice cover are identified as contributors to differences in AMOC. These differences in the solutions do not suggest an obvious grouping of the models based on their ocean model lineage, their vertical coordinate representations, or surface salinity restoring strengths. Thus, the solution differences among the models are attributed primarily to use of different subgrid scale parameterizations and parameter choices as well as to differences in vertical and horizontal grid resolutions in the ocean models. Use of a wide variety of sea-ice models with diverse snow and sea-ice albedo treatments also contributes to these differences. Based on the diagnostics considered, the majority of the models appear suitable for use in studies involving the North Atlantic, but some models require dedicated development effort. atmospheric forcing atmospheric temperatures

ocean model comparisons↗

Aquarius Radiometer and Scatterometer Weekly-Polar-Gridded Products to Monitor Ice Sheets, Sea Ice, and Frozen Soil

Space-based microwave sensors have been available for several decades, and with time more frequencies have been offered. Observations made at frequencies between 7 and 183 GHz were often used for monitoring cryospheric properties (e.g. sea ice concentration, snow accumulation, snow melt extent and duration). Since 2009, satellite observations are available at the low frequency of 1.4 GHz. Such observations are collected by the Soil Moisture and Ocean Salinity (SMOS) mission, and the AquariusSAC-D mission. Even though these missions have been designed for the monitoring of soil moisture and sea surface salinity, new applications are being developed to study the cryosphere. For instance, L-band observations can be used to monitor soil freezethaw (e.g. Rautiainen et al., 2012), and thin sea ice thickness (e.g. Kaleschke et al., 2010, Huntemann et al., 2013). Moreover, with the development of satellite missions comes the need for calibration and validation sites. These sites must have stable characteristics, such as the Antarctic Plateau (Drinkwater et al., 2004, Macelloni et al., 2013). Therefore, studying the cryosphere with 1.4 GHz observations is relevant for both science applications, and remote sensing applications.

Aquarius↗

Estimating Major Ion and Nutrient Concentrations in Mangrove Estuaries in Everglades National Park Using Leaf and Satellite Reflectance

Coastal mangrove ecosystems are under duress worldwide because of urban development, sea-level rise, and climate change, processes that are capable of changing the salinity and nutrient concentration of the water utilized by the mangroves. This study correlates long-term water chemistry in mangrove environments, located in Everglades National Park,with mangrove spectral reflectance measurements made at both the leaf and canopy scales. Spectral reflectance measurements were collected using a handheld spectrometer for leaf-level measurements and Landsat 5TMdata for regional coverage. Leaf-level reflectance data were collected from three mangrove species (i.e., red, black and white mangroves) across two regions; a tall mangrove (approximately 18m) and dwarf mangrove (1- 2 m) region. The reflectance data were then used to calculate a wide variety of biophysical reflectance indices (e.g., NDVI, EVI, SAVI) to determine signs of stress. Discrete, quarterly water samples from the surface water, groundwater, and pore water (20 and 85 cm depths) and daily autonomous surface water samples were collected at each site and analyzed for major anions (Cl(−) and SO(2(-)/4)), cations (Na(+), K(+), Mg(sup 2(+)), and Ca(sup 2(+)), total nitrogen (TN) and total phosphorus (TP).Mangrove sites that exhibited the highest salinity and ionic concentrations in the surface and subsurface water also had the lowest near-infrared reflectance at both the leaf and satellite levels. Seasonal reflectance responses were measured in the near-infrared (NIR) wavelengths at both the leaf and canopy scales and were strongly correlated with nutrient and ionic concentrations in the surface and subsurface water, even though there was no significant separability between the three mangrove species. Study sites that experienced the greatest variability in surface and subsurface water ionic concentrations also exhibited the greatest fluctuations in NIR spectral reflectance. Landsat 5TM images were able to detect tall and dwarf mangroves by the differences in spectral indices (e.g., NDVI, NDWI, and EVI) because of the variability in the background conditions amongst the environments. In addition, Landsat 5TM images spanning 16 years (1993- 2009) were successfully used to estimate the seasonal variability in ionic concentrations in the surface water across the Florida Coastal mangrove ecotone. This study has shown that water chemistry can be estimated indirectly by measuring the change in spectral response at the leaf- or satellite-scale. Furthermore, the results of this research may be extrapolated to similar coastal mangrove systems throughout the Caribbean and world-wide wherever red, black, and white mangroves occur.

Mangroves↗

Aquarius Radiometer and Scatterometer Weekly Polar-Gridded Products to Monitor Ice Sheets, Sea Ice, and Frozen Soil

Space-based microwave sensors have been available for several decades, and with time more frequencies have been offered. Observations made at frequencies between 7 and 183 GHz were often used for monitoring cryospheric properties (e.g. sea ice concentration, snow accumulation, snow melt extent and duration). Since 2009, satellite observations are available at the low frequency of 1.4 GHz. Such observations are collected by the Soil Moisture and Ocean Salinity (SMOS) mission, and the Aquarius/SAC-D mission. Even though these missions have been designed for the monitoring of soil moisture and sea surface salinity, new applications are being developed to study the cryosphere. For instance, L-band observations can be used to monitor soil freeze/thaw (e.g. Rautiainen et al., 2012), and thin sea ice thickness (e.g. Kaleschke et al., 2010, Huntemann et al., 2013). Moreover, with the development of satellite missions comes the need for calibration and validation sites. These sites must have stable characteristics, such as the Antarctic Plateau (Drinkwater et al., 2004, Macelloni et al., 2013). Therefore, studying the cryosphere with 1.4 GHz observations is relevant for both science applications, and remote sensing applications.

Sea ice↗