Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rf source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of an Accelerator Mass Spectrometer based on a Cyclotron

An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

43 PARTICLE ACCELERATORS↗

Characterization of the CW starter plasma RF matching network for operating the SNS H{sup −} ion source with lower H{sub 2} flows

The Spallation Neutron Source H{sup −} ion source is operated with a pulsed 2-MHz RF (50-60 kW) to produce the 1-ms long, ∼50 mA H{sup −} beams at 60 Hz. A continuous low power (∼300 W) 13.56-MHz RF plasma, which is initially ignited with a H{sub 2} pressure bump, serves as starter plasma for the pulsed high power 2-MHz RF discharges. To reduce the risk of plasma outages at lower H{sub 2} flow rates which is desired for improved performance of the following radio frequency quadrupole, the 13.56-MHz RF matching network was characterized over a broad range of its two tuning capacitors. The H-α line intensity of the 13.56-MHz RF plasma and the reflected power of the 13.56-MHz RF were mapped against the capacitor settings. Optimal tunes for the maximum H-α intensity are consistent with the optimal tunes for minimum reflected power. Low limits of the H{sub 2} flow rate not causing plasma outages were explored within the range of the map. A tune region that allows lower H{sub 2} flow rate has been identified, which differs from the optimal tune for global minimum reflected power that was mostly used in the past.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF Heating in Electron Cyclotron Resonance Ion Sources

ECRIS-Electron Cyclotron Resonance Ion Sources are able to feed accelerators with intense currents of highly charged ions. In ECRIS a high density-high temperature plasma is generated by means of the Electron Cyclotron Resonance Heating inside a B-min, MHD stable trap. The state of the art about the principal heating mechanisms will be given. The paper will specially discuss the most critical and still open issues concerning the influence of the magnetic field and of the RF frequency on the plasma heating, as well as the impact of possible non-linear pumping wave-to-plasma interactions. The contribution of INFN-LNS will be specifically underlined. A short review on the future perspectives for the design of new generation ion sources will be given in conclusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent ~38 mA peak current in the linac and an availability of ~90%. The ~1 ms-long, 60 Hz, ~50 mA H- beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of ~99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source for a Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x1011 n/s for D-T and ~;;1x1010 n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm2) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm2 was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance studies of the SNS external-antenna H- ion source

A new Allison-type emittance scanner has been built to characterize the ion sources and low energy beam transport systems at SNS. In this work, the emittance characteristics of the H- beam produced with the external-antenna RF-driven ion source and transported through the 2-lens electrostatic LEBT are studied. The beam emittance dependence on beam intensity, extraction parameters, and the evolution of the emittance and twiss parameters over beam pulse duration are presented.

Han, Baoxi↗

Utilizing gas-filled cavities for the generation of an intense muon source

A key requirement for designing intense muon sources is operating rf cavities in multi-tesla magnetic fields. Recently, a proof-of-principle experiment demonstrated that an rf cavity filed with high pressure hydrogen gas could meet this goal. In this study, rigorous simulation is used to design and evaluate the performance of an intense muon source with gas filled cavities. We present a new lattice design and compare our results with conventional schemes. We detail the influence of gas pressure on the muon production rate.

43 PARTICLE ACCELERATORS↗

Self-consistent modeling of radio-frequency plasma generation in stellarators

A self-consistent model of radio-frequency (RF) plasma generation in stellarators in the ion cyclotron frequency range is described. The model includes equations for the particle and energy balance and boundary conditions for Maxwell’s equations. The equation of charged particle balance takes into account the influx of particles due to ionization and their loss via diffusion and convection. The equation of electron energy balance takes into account the RF heating power source, as well as energy losses due to the excitation and electron-impact ionization of gas atoms, energy exchange via Coulomb collisions, and plasma heat conduction. The deposited RF power is calculated by solving the boundary problem for Maxwell’s equations. When describing the dissipation of the energy of the RF field, collisional absorption and Landau damping are taken into account. At each time step, Maxwell’s equations are solved for the current profiles of the plasma density and plasma temperature. The calculations are performed for a cylindrical plasma. The plasma is assumed to be axisymmetric and homogeneous along the plasma column. The system of balance equations is solved using the Crank-Nicholson scheme. Maxwell’s equations are solved in a one-dimensional approximation by using the Fourier transformation along the azimuthal and longitudinal coordinates. Results of simulations of RF plasma generation in the Uragan-2M stellarator by using a frame antenna operating at frequencies lower than the ion cyclotron frequency are presented. The calculations show that the slow wave generated by the antenna is efficiently absorbed at the periphery of the plasma column, due to which only a small fraction of the input power reaches the confinement region. As a result, the temperature on the axis of the plasma column remains low, whereas at the periphery it is substantially higher. This leads to strong absorption of the RF field at the periphery via the Landau mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing Gas Filled Cavities for the Generation of an Intense Muon Source

A key requirement for designing intense muon sources is operating rf cavities in multi-tesla magnetic fields. Recently, a proof-of-principle experiment demonstrated that an rf cavity filed with high pressure hydrogen gas could meet this goal. In this study, rigorous simulation is used to design and evaluate the performance of an intense muon source with gas filled cavities. We present a new lattice design and compare our results with conventional schemes. We detail the influence of gas pressure on the muon production rate.

43 PARTICLE ACCELERATORS↗

Electron beam loss assumptions for ELI-NPMEGa-ray radioprotection analysis

The ELI-NP project is now working on the design of their conventional facility. Dr. Gheorghe Cata-Danil recently requested that I provide them with information on the location and amount of electron-beam loss in the MEGa-ray source they have proposed for ELI-NP. This memo is intended to document that information, for transmission to ELI-NP. The ELI-NP MEGa-ray source, as presently proposed, consists of two x-band accelerator sections separated by a large chicane, as show in figure 1. The basic parameters of the machine that are pertinent for specifying the radiation source terms are shown in table 1. These are the parameters of the intentionally-produced photobeam. In addition to the photobeam, the electron gun and accelerator will produce 'dark current' that originates throughout the RF structures (that is, distributed along the accelerator axis) and therefore has a distribution of energy below the energy of the photobeam. Because it is emitted from surfaces inside the RF structures, much of it is not transported through the accelerator and is lost in the accelerator RF structures. A large fraction of the total dark current is produced in the photogun and lost at the entrance of the 1st accelerator RF structure. Important sources of radiation during operation are beam alignment screens that are used for observing the image of the electron beam, during adjustment of beam steering and for general diagnostic purposes. Each screen consists of a 1 mm thick Ce:YAG plate that is moved into the path of the beam when desired. This destroys the electron beam, spraying all beam current into the structures downstream of the screen. Only one screen is inserted at a time. These screens may be located after each accelerator RF structure, and after each set of bend magnets, as shown in figure 3. The photobeam energy and currents at each location are listed in table 2; for simplicity, the dark current energy is (conservatively) assumed to be the same as the photobeam energy. In normal operation, the locations of other beam losses and the estimated current and energy of the lost beam are listed in table 3. In addition to these 'normal' beam losses, it is assumed that the beam may be accidentally mis-steered by up to 1 degree at every steering magnet, so that it hits the surrounding beam tube and other structures. This loss can be modeled as occurring at the locations listed in table 2, numbers 1-7 and 16-21. Similarly, it is assumed that any of the dipole magnets, in chicanes or at the beam dump, may fail, resulting in total beam loss straight ahead. These locations can be assumed to be the same as listed in table 2, numbers 8-10, 12-14, 22-24, 26, and 27. The data provided above are estimates of the beam loss, for the purpose of calculating radiation source terms. Dark current estimates are conservative, until we acquire actual operational data. Neither the estimated currents nor the estimated energies listed above contain any intentional margin. when they have performed similar calculations for their own purposes, they have typically added approximately 10% to the beam energy to provide some overall margin in the analysis.

42 ENGINEERING↗

Compact Electronic Gamma Source For Radiotherapy

A compact mono-energetic gamma source is being developed to replace the radiological sources used in radiotherapy and other medical instruments. The electronic gamma source utilizes low-energy nuclear reactions to generate gammas in the 0.5 to 1.0 MeV energy range. Independent control of the ion current and energy is achieved by decoupling the RF-driven ion source and pyroelectric crystal-based acceleration systems The ions are accelerated to voltages above 100 keV and bombard a reaction target to produce gammas. Thermal management of the pyroelectric crystal-based accelerator is achieved by convective dielectric fluid flow around the crystal. This approach provides better temperature uniformity in the crystal and higher dielectric strength for suppressing voltage breakdown and enabling faster thermal cycling rates.

43 PARTICLE ACCELERATORS↗

Commissioning of the new H{sup -} source for Linac4

As part of the CERN accelerator complex upgrade, a new linear accelerator for H{sup -} (Linac4) will start its operation in 2014. The source for this linac will be a 2 MHz rf driven H{sup -} source which is a copy of the very successful source from DESY. In this paper the design and the first results of the commissioning are reported. The commissioning has progressed successfully, and no major obstacles have been identified which will prevent reaching the goal of 80 mA H{sup -} beam current, 45 keV beam energy, 0.4 ms pulse length, and 2 Hz repetition rate. The source is producing up until now a stable beam of 23 mA, 35 keV, and with a repetition rate of 0.83 Hz.

43 PARTICLE ACCELERATORS↗

Effect of plasma grid bias on extracted currents in the RF driven surface-plasma negative ion source

Extraction of negative ions from the large inductively driven surface-plasma negative ion source was studied. The dependencies of the extracted currents vs plasma grid (PG) bias potential were measured for two modifications of radio-frequency driver with and without Faraday screen, for different hydrogen feeds and for different levels of cesium conditioning. The maximal PG current was independent of driver modification and it was lower in the case of inhibited cesium. The maximal extracted negative ion current depends on the potential difference between the near-PG plasma and the PG bias potentials, while the absolute value of plasma potential in the driver and in the PG area is less important for the negative ion production. The last conclusion confirms the main mechanism of negative ion production through the surface conversion of fast atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing W sources in the all-W wall, all-RF WEST tokamak environment

In this work, experimental data, together with interpretive modeling tools, are examined to study trends in the tungsten (W) source in the all-W environment of the WEST tokamak, both from the divertor and from the main chamber. In particular, a poloidal limiter protecting an ion cyclotron resonance heating (ICRH) antenna is used as proxy for main chamber sourcing. The key study is carried out by stepping up lower hybrid current drive (LHCD) power, as the only auxiliary power source. Limiter and divertor W sources exhibit a qualitatively similar proportionality to the total power crossing the separatrix, P SEP , although the main chamber source remains substantially lower than the divertor source, for the range of P SEP accessible in the experiments. Intepretive modeling of the limiter source is carried out with a particle-in-cell (PIC) sheath model coupled to a surface sputtering model. Oxygen is used as a proxy for all light impurity species allowing for characterization of the critical W erosion regions. To get a good quantitative match to the data, it is necessary to assume that the oxygen arrives at the surface mostly at high ionization stages (4+ and above). A separate simulation with SOLEDGE-EIRENE, constrained to measured upstream scrape-off-layer plasma profiles, gives oxygen fractional abundances that are compatible with the PIC simulation result. This is understood to arise from transport processes that dominate over recombination. Substituting the LHCD by ICRH, in an equivalent experiment, the local W source exhibits a 3× enhancement. This can be matched by the simulation, by assuming local RF electric field rectification, based on ~100 eV peak-to-peak, near-antennna electric field. This work has highlighted the particular importance of understanding the ion charge state balance of light impurities as these are most likely the dominant sputtering species in fusion devices with high-Z walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling activities on the negative-ion-based Neutral Beam Injectors of the Large Helical Device

At the National Institute for Fusion Science (NIFS) large-scaled negative ion sources have been widely used for the Neutral Beam Injectors (NBIs) mounted on the Large Helical Device (LHD), which is the world-largest superconducting helical system. These injectors have achieved outstanding performances in terms of beam energy, negative-ion current and optics, and represent a reference for the development of heating and current drive NBIs for ITER.In the framework of the support activities for the ITER NBIs, the PRIMA test facility, which includes a RF-drive ion source with 100 keV accelerator (SPIDER) and a complete 1 MeV Neutral Beam system (MITICA) is under construction at Consorzio RFX in Padova.An experimental validation of the codes has been undertaken in order to prove the accuracy of the simulations and the soundness of the SPIDER and MITICA design. To this purpose, the whole set of codes have been applied to the LHD NBIs in a joint activity between Consorzio RFX and NIFS, with the goal of comparing and benchmarking the codes with the experimental data. A description of these modeling activities and a discussion of the main results obtained are reported in this paper.

43 PARTICLE ACCELERATORS↗