Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Improved accuracy of the remote sensing of sea surface temperature

A method is described for determining the water vapor content to within + or - 0.4 g/sq cm from remotely sensed radiances in three infrared channels, 11, 13, 18 microns. Using this method, it is possible to significantly improve the accuracy of sea surface temperature (SST) over what is obtainable with the two channel technique. A radiative computational scheme for the radiative transfer equation is used to study the manner in which the equivalent radiative temperature of the atmosphere changes as a function of wave number for different atmospheric conditions. Average climatological conditions are used to simulate the radiative response of the atmosphere. This radiative transfer simulation is used to compute brightness temperatures for radiosonde profiles obtained from oceanographic ships, which temperatures are in turn used to estimate the SST. Nimbus 4 IRIS spectral measurements corresponding to the profiles were used in the same way for purposes of comparison.

Dalu, G.↗

1st Order Modeling of a SAW Delay Line using MathCAD(Registered)

To aid in the development of SAW sensors for Integrated Vehicle Health Monitoring applications, a first order model of a SAW Delay line has been created using MathCadA. The model implements the Impulse Response method to calculate the frequency response, impedance, and insertion loss. This paper presents the model and the results from the model for a SAW delay line design. Integrated Vehicle Health Monitoring (IVHM) of aerospace vehicles requires rugged sensors having reduced volume, mass, and power that can be used to measure a variety of phenomena. Wireless systems are preferred when retro-fitting sensors onto existing vehicles [1]. Surface Acoustic Wave (SAW) devices are capable of sensing: temperature, pressure, strain, chemical species, mass loading, acceleration, and shear stress. SAW technology is low cost, rugged, lightweight, and extremely low power. Passive wireless sensors have been developed using SAW technology. For these reasons new SAW sensors are being investigated for aerospace applications.

Wilson, William C.↗

A novel boundary layer sensor utilizing domain switching in ferroelectric liquid crystals

This paper describes the design and the principles of operation of a novel sensor for the optical detection of a shear stress field induced by air or gas flow on a rigid surface. The detection relies on the effects of shear-induced optical switching in ferroelectric liquid crystals. It is shown that the method overcomes many of the limitations of similar measuring techniques including those using cholesteric liquid crystals. The present method offers a preferred alternative for flow visualization and skin friction measurements in wind-tunnel experiments on laminar boundary layer transition investigations. A theoretical model for the optical response to shear stress is presented together with a schematic diagram of the experimental setup.

Parmar, D. S.↗

Active control of sound radiation from a vibrating rectangular panel by sound sources and vibration inputs - An experimental comparison

Active control of sound radiation from a rectangular panel by two different methods has been experimentally studied and compared. In the first method a single control force applied directly to the structure is used with a single error microphone located in the radiated acoustic field. Global attenuation of radiated sound was observed to occur by two main mechanisms. For 'on-resonance' excitation, the control force had the effect of increasing the total panel input impedance presented to the nosie source, thus reducing all radiated sound. For 'off-resonance' excitation, the control force tends not significantly to modify the panel total response amplitude but rather to restructure the relative phases of the modes leading to a more complex vibration pattern and a decrease in radiation efficiency. For acoustic control, the second method, the number of acoustic sources required for global reduction was seen to increase with panel modal order. The mechanism in this case was that the acoustic sources tended to create an inverse pressure distribution at the panel surface and thus 'unload' the panel by reducing the panel radiation impedance. In general, control by structural inputs appears more effective than control by acoustic sources for structurally radiated noise.

Fuller, C. R.↗

Scattering of ultrasonic wave by cracks in a plate

A hybrid numerical method combining finite elements and the boundary integral representation is used to investigate the transient scattering of ultrasonic waves by a crack in a plate. The incident wave models the guided waves generated by a steel ball impact on the plate. Two surface-breaking cracks and one subsurface crack are studied here. The results show that the location and depth of cracks have measurable effects on the surface responses in time and frequency domains. Also, the scattered fields have distinct differences in the three cases.

Liu, S. W.↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Environmentally induced discharges on satellites

A discharge process whose trigger conditions are a negative exposed metallic surface surrounded by a less negative dielectric, and a large voltage gradient at a dielectric/metal interface is proposed. Analysis of SCATHA data for a discharge substantiates the postulation. Surface discharges cause a small transient charge transfer to space which results in voltage transients. A method of computing these transients, based on the charge lost through the capacitance to space and a fraction of charge stored in the dielectric at the discharge source was developed. It gives an estimate of the discharge transients at the discharge site, which is used as input for coupling code analysis of structure/system response. The transient computations were applied to a three-axis stabilized, geosynchronous satellite for both sunlight and eclipse charging. The energy of the transient pulses are about 1 mJ for sunlight discharge and 8 mJ for eclipse. Changing of selected coatings on the satellite would relieve the stress.

Stevens, N. J.↗

Experimental and analytical determination of gear tooth temperatures with oil jet lubrication

Gear tooth average and instantaneous surface temperatures were measured with a fast response infrared radiometric microscope, while operating at arious speeds, loads and oil jet pressures. Increased oil jet pressure had a significant effect on both average and peak surface temperatures at all test conditions, increasing the speed at constant load and increasing the load at constant speed causes a significant rise in average and peak surface temperatures of gear teeth. A gear tooth temperature analysis was conducted by a finite element method combined with a calculated heat input and oil jet impingment depth with estimated heat transfer coefficients based on the experimental data. It is concluded that oil jet pressures required for adequate cooling at high load and speed conditions must be high enough to get full penetration depth of the teeth.

Townsend, D. P.↗

Ohio's Abandoned Mine Lands Reclamation Program: a Study of Data Collection and Evaluation Techniques

The planning process for a statewide reclamation plan of Ohio abandoned minelands in response to the Federal Surface Mining Control and Reclamation Act of 1977 included: (1) the development of a screening and ranking methodology; (2) the establishment of a statewide review of major watersheds affected by mining; (3) the development of an immediate action process; and (4) a prototypical study of a priority watershed demonstrating the data collection, analysis, display and evaluation to be used for the remaining state watersheds. Historical methods for satisfying map information analysis and evaluation, as well as current methodologies being used were discussed. Various computer mapping and analysis programs were examined for their usability in evaluating the priority reclamation sites. Hand methods were chosen over automated procedures; intuitive evaluation was the primary reason.

Sperry, S. L.↗

Possible flexural signatures around Olympus and Ascraeus Montes, Mars

The effective elastic thickness (h) of the lithosphere provides a measure of the thermal and mechanical state of a planet's shallow interior. An estimate of h in the vicinity of a feature that constitutes a load on a planetary surface can be determined from the flexural response of the lithosphere to the load. This approach has been applied to Mars by calculating radial stresses associated with lithospheric flexure associated with surface loads, and comparing the results to the positions of circumferential graben surrounding the major Martian shield volcanoes and mascon basins. However, many prominent surface loads on Mars, most notably the Olympus Mons volcano, do not exhibit flexural graben. In these instances application of the above method can provide only a lower limit of effective elastic thickness. An alternative method of determining h is to calculate the vertical displacements associated with the flexural loading and to compare the amplitude and shape of the flexural profile to observed topography. This method has not been applied to flexural problems on Mars because of the poor resolution of Martian topographic data. However, previous analyses have shown that the lithosphere around major volcanic shields should exhibit vertical deflections of order 1 km over horizontal baselines of order 100 km. We were thus motivated to search for the presence of flexural troughs in the existing Mars topography data.

Zuber, M. T.↗

Biosignature False Positives

In our search for life - whether within the earliest part of Earth's geologic record, on planets within our solar system such Mars, or especially for extrasolar planets - we must infer the presence of life from its impact on the local or global environment. These "biosignatures," often identified from the known influence of terrestrial organisms on the Earth's atmosphere and surface, could be misdiagnosed when we apply them to alien worlds. The so-called false positives may occur when another process or suite of processes masks or mimics a biosignature. Here, we examine several leading biosignatures, then introduce potential false positives for these signals, and finally discuss methods to discriminate between the two using current and future detection technologies. We conclude that it is the astrobiology community's responsibility to thoroughly exhaust all possibilities before we resort to "life" as an explanation.

Harman, Chester E.↗

Current status of silicon solar cell technology

Recent advances in solar cell technology have led to the development of laboratory cells with efficiencies above 15% and production cells with efficiencies in the area of 13%. The increased output is largely the result of increases in the short-circuit current. The most significant gain in the amount of light entering the cell has been obtained through surface texturing by chemical etching techniques. Sheet resistances resulting from phosphorus diffusion in the 800 C temperature range yield junction depths on the order of 0.1 micrometer, leading to significant increases in the blue region of the cell spectral response. The inclusion of a back surface field in 10 ohm-cm cells has produced an increase in open-circuit voltage of about 50 mV and an increase in the minority carrier lifetime. It appears that a low emitter efficiency of the diffused region is the cause of poor voltages. Future research will be primarily directed toward correcting this deficiency and toward the development of low cost production methods.

Brandhorst, H. W., Jr.↗

Genesis lunar outpost criteria and design

This design study--the third in the space architecture series--focused on the requirements of an early stage lunar outpost. The driving assumptions of the scenario was that the base would serve as a research facility and technology testbed for future Mars missions, a habitat supporting 12 persons for durations of up to 20 months, and would sustain the following five experimental facilities: Lunar surface mining and production analysis facility, construction technology and materials testbed, closed environmental life support system (CELSS) test facility, lunar farside observatory, and human factors and environment-behavior research facility. Based upon the criteria set forth in a previous programming document, three preliminary lunar base designs were developed. Each of the three schemes studied a different construction method and configuration. The designs were then evaluated in terms of environmental response, human habitability, transportability, constructability, construction dependability and resilience, and their suitability in carrying out the desired scientific research. The positive points of each scheme were then further developed by the entire project team, resulting in one integrated lunar outpost design.

Hansmann, Timothy↗

A miniature high frequency sphere probe

A spherical probe having five surface mounted silicon pressure sensors is described. The probe is 0.2 inches in diameter yielding a frequency response above 30 kHz. A scheme is described for retrieving from the five pressure signals the stagnation and static pressures, Mach number and flow angles in two planes. The calibrations forming the base for this procedure, obtained from steady state tests, are given in the form of polynomials in the two flow angles. A method for compensating the silicon pressure sensors for thermal effects is given. Typical data obtained in the MIT Blowdown Compressor are presented in raw form and after reduction to flow angles, Mach number and stagnation pressure.

Kerrebrock, J. L.↗

Compact Simultaneous-beam Optical Strain Measurement System, Phase 5

Recent advances on the laser speckle strain measurement system under development at NASA Lewis Research Center have resulted in a compact, easy-to-use measurement package having many performance improvements over previous systems. NASA has developed this high performance optical strain measurement system for high temperature material testing applications. The system is based on I. Yamaguchi's two-beam speckle-shift strain measurement theory, and uses a new optical design that allows simultaneous recording of laser speckle patterns. This design greatly improves system response over previous implementations of the two-beam speckle-shift technique. The degree of immunity to transient rigid body motions is no longer dependent on the data transfer rate. The system automatically calculates surface strains at a frequency of about 5 Hz using a high speed digital signal processor in a personal computer. This system is fully automated, and can be operated remotely. This report describes the designs and methods used by the system, and shows low temperature strain test results obtained from small diameter tungsten-rhenium and palladium-chrome wires.

Lant, Christian T.↗

Contact position sensor using constant contact force control system

A force control system (50) and method are provided for controlling a position contact sensor (10) so as to produce a constant controlled contact force therewith. The system (50) includes a contact position sensor (10) which has a contact probe (12) for contacting the surface of a target to be measured and an output signal (V.sub.o) for providing a position indication thereof. An actuator (30) is provided for controllably driving the contact position sensor (10) in response to an actuation control signal (I). A controller (52) receives the position indication signal (V.sub.o) and generates in response thereto the actuation control signal (I) so as to provide a substantially constant selective force (F) exerted by the contact probe (12). The actuation drive signal (I) is generated further in response to substantially linear approximation curves based on predetermined force and position data attained from the sensor (10) and the actuator (30).

Sturdevant, Jay↗

Sensitivity Analysis of Launch Vehicle Debris Risk Model

As part of an analysis of the loss of crew risk associated with an ascent abort system for a manned launch vehicle, a model was developed to predict the impact risk of the debris resulting from an explosion of the launch vehicle on the crew module. The model consisted of a debris catalog describing the number, size and imparted velocity of each piece of debris, a method to compute the trajectories of the debris and a method to calculate the impact risk given the abort trajectory of the crew module. The model provided a point estimate of the strike probability as a function of the debris catalog, the time of abort and the delay time between the abort and destruction of the launch vehicle. A study was conducted to determine the sensitivity of the strike probability to the various model input parameters and to develop a response surface model for use in the sensitivity analysis of the overall ascent abort risk model. The results of the sensitivity analysis and the response surface model are presented in this paper.

Gee, Ken↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

The Porous Microstructure Analysis (PuMA) software is a suite of tools for the analysis of porous materials and generation of material microstructures. From microstructural data, often obtained through X-ray microtomography, PuMA can determine a number of effective material properties and perform material response simulations. Version 2.2 includes capabilities for computing volume fractions, porosity, specific surface area, effective thermal and electrical conductivities, and continuum and rarefied diffusive tortuosity. PuMA can also simulate competitive diffusion/reaction processes at the micro-scale, such as surface oxidation. In this poster, recent advancements to the PuMA software are detailed, including the full refactoring of PuMA into v3.0, a new module to compute heat conduction in anisotropic materials, a particle method for simulating molecular beam experiments, a new finite-volume Laplace solver, complex fibrous material generation, woven material generation, and a coupling of PuMA with the DAKOTA software for advanced statistics.

PuMA↗