Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A new data-driven map predicts substantial undocumented peatland areas in Amazonia

Tropical peatlands are among the most carbon-dense terrestrial ecosystems yet recorded. Collectively, they comprise a large but highly uncertain reservoir of the global carbon cycle, with wide-ranging estimates of their global area (441 025–1700 000 km 2 ) and below-ground carbon storage (105–288 Pg C). Substantial gaps remain in our understanding of peatland distribution in some key regions, including most of tropical South America. Here we compile 2413 ground reference points in and around Amazonian peatlands and use them alongside a stack of remote sensing products in a random forest model to generate the first field-data-driven model of peatland distribution across the Amazon basin. Our model predicts a total Amazonian peatland extent of 251 015 km 2 (95th percentile confidence interval: 128 671–373 359), greater than that of the Congo basin, but around 30% smaller than a recent model-derived estimate of peatland area across Amazonia. The model performs relatively well against point observations but spatial gaps in the ground reference dataset mean that model uncertainty remains high, particularly in parts of Brazil and Bolivia. For example, we predict significant peatland areas in northern Peru with relatively high confidence, while peatland areas in the Rio Negro basin and adjacent south-western Orinoco basin which have previously been predicted to hold Campinarana or white sand forests, are predicted with greater uncertainty. Similarly, we predict large areas of peatlands in Bolivia, surprisingly given the strong climatic seasonality found over most of the country. Very little field data exists with which to quantitatively assess the accuracy of our map in these regions. Data gaps such as these should be a high priority for new field sampling. This new map can facilitate future research into the vulnerability of peatlands to climate change and anthropogenic impacts, which is likely to vary spatially across the Amazon basin.

54 ENVIRONMENTAL SCIENCES↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

New insights on the nebular emission, ionizing radiation, and low metallicity of Green Peas from advanced modelling

ABSTRACT Low-metallicity, compact starburst galaxies referred to as Green Peas (GPs) provide a unique window to study galactic evolution across cosmic epochs. In this work, we present new deep optical spectra for three GPs from OSIRIS at the 10-m Gran Telescopio Canarias, which are studied using a state-of-the-art methodology. A stellar population synthesis is conducted with 1098 spectral templates. The methodology succeeds at characterizing stellar populations from 0.5 Myr to 10 Gyr. The light distribution shows a large red excess from a single population with ${log}\left({age}\right) \gt 8.5\, \mathrm{yr}$ in the GP sample analysed. This points towards an incomplete characterization of the gas luminosity, whose continuum already accounts between 7.4 and $27.6{{\ \rm per\ cent}}$ in the galaxy sample. The emission spectra are fitted with the largest Bayesian chemical model consisting of an electron temperature, an electron density, the logarithmic extinction coefficient and eleven ionic species under the direct method paradigm. Additionally, building on previous work, we propose a neural networks sampler to constrain the effective temperature and ionization parameter of each source from photoionization model grids. Finally, we combine both methodologies into a 16-dimensional model, which for the first time, simultaneously explores the direct method and photoionization parameter spaces. Both techniques consistently indicate a low-metallicity gas, $7.76\lt 12+{\rm log}\left(O/H \right)\lt 8.04$, ionized by strong radiation fields, in agreement with previous works.

Fernández, V. (ORCID:0000000305315450)↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Line Rating Models and Their Potential for a Cost‐Effective Transition to Carbon‐Neutral Power Systems

Most transmission system operators (TSOs) currently use seasonally steady-state models considering limiting weather conditions that serve as reference to compute the transmission capacity of overhead power lines. The use of dynamic line rating (DLR) models can avoid the construction of new lines, market splitting, false congestions, and the degradation of lines in a cost-effective way. DLR can also be used in the long run in grid extension and new power capacity planning. In the short run, it should be used to help operate power systems with congested lines. The operation of the power systems is planned to have the market trading into account; thus, it computes transactions hours ahead of real-time operation, using power flow forecasts affected by large errors. In the near future, within a “smart grid” environment, in real-time operation conditions, TSOs should be able to rapidly compute the capacity rating of overhead lines using DLR models and the most reliable weather information, forecasts, and line measurements, avoiding the current steady-state approach that, in many circumstances, assumes ampacities above the thermal limits of the lines. Here, this work presents a review of the line rating methodologies in several European countries and the United States. Furthermore, it presents the results of pilot projects and studies considering the application of DLR in overhead power lines, obtaining significant reductions in the congestion of internal networks and cross-border transmission lines.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transfer learning of memory kernels for transferable coarse-graining of polymer dynamics

The present work concerns the transferability of coarse-grained (CG) modeling in reproducing the dynamic properties of the reference atomistic systems across a range of parameters. In particular, we focus on implicit-solvent CG modeling of polymer solutions. The CG model is based on the generalized Langevin equation, where the memory kernel plays the critical role in determining the dynamics in all time scales. Thus, we propose methods for transfer learning of memory kernels. The key ingredient of our methods is Gaussian process regression. By integration with the model order reduction via proper orthogonal decomposition and the active learning technique, the transfer learning can be practically efficient and requires minimum training data. Through two example polymer solution systems, we demonstrate the accuracy and efficiency of the proposed transfer learning methods in the construction of transferable memory kernels. The transferability allows for out-of-sample predictions, even in the extrapolated domain of parameters. Built on the transferable memory kernels, the CG models can reproduce the dynamic properties of polymers in all time scales at different thermodynamic conditions (such as temperature and solvent viscosity) and for different systems with varying concentrations and lengths of polymers.

Ma, Zhan↗

Simulink Modeling and Dynamic Study of Fixed-Speed, Variable-Speed, and Ternary Pumped Storage Hydropower

Pumped Storage Hydropower (PSH) is one of the most popular energy storage technologies in the world. It uses an upper reservoir to store water which can be later used during high-demand. In the United States, most of the energy storage capability actually corresponds to PSH. Moreover, PSH also brings multiple benefits to grid operation. This report presents the Simulink models of three common PSH technologies: Fixed-Speed (FS), Variable-Speed (VS), and Ternary (T)-PSH. These models are available to the general public on this GitHub repository, which contains the MATLAB model initialization files, the Simulink model files, and supplementary MATLAB code used to obtain the figures in this work. For each PSH model, an introductory description of the model components and other relevant functionalities are provided. For further information regarding the models and the initialization parameters, the reader is referred to the shared files in the repository. This report also presents the dynamic behavior of each model. The response of such models to a load event is analyzed and matched with each model's features. A custom IEEE 39 bus case is employed for the FS and T-PSH simulations, while the VS-PSH is simulated on a simplified three-bus test system due to the computational complexity of the model. For the T-PSH, the steady-state and the switching between several operating modes are also studied in this work.

13 HYDRO ENERGY↗

Three-Stage Adjusted Regression Forecasting for Software Defect Prediction

In this paper, a three-stage adjusted regression forecasting model is proposed to forecast the local regression model [6]. This is a growth curve approximation model that predicts the parameters for a future linear model based on a sliding window of previous linear models. The three stages of the model are as follows: • Initial fit: train regression models on a sliding window of the date and record model coefficients. • Prediction: fit new regression models to the coefficient lists and predict the value of the next coefficient. • Error correction: correct coefficient prediction error using the residual of the last point of the coefficient list and moving average. The resulting model from the multi-stage process is a forecast of the local regression model that represents the future window of data and is referred to as the predicted line. Results suggest the three-stage model demonstrates better prediction capability compared to existing solutions.

Pritchard, Shadow↗

Effect of geometry and operational parameters on the dehumidification performance of a desiccant coated heat exchanger

Solid desiccant dehumidification systems are an alternative to vapor-compression-based air dehumidification systems. They use solid desiccant materials to adsorb air moisture in space cooling. DCHE can integrate the cooling component in the heat exchanger to achieve higher dehumidification capacity. Comprehensive numeric modeling would be necessary to assist in the design and operation of the DCHE under development to achieve maximum performance. Here, we provide the details of a heat and mass transfer model developed for this purpose. The model aims to cover a gap in existing models by independently modeling heat transfer on the solid desiccant, fin, and tube. The model results were compared with an experimental reference for validation. The air outlet humidity and temperature results for dehumidification and regeneration showed a deviation lower than 15% from the experiment. The validated model was used to perform a parametric study for a series of design and operating conditions. The parametric analysis showed that an increase of 25% in desiccant layer thickness and thermal contact resistance between solid elements reduces moisture removal by 9.1% and 1%, respectively. These results indicate the need to independently model the desiccant layer.

42 ENGINEERING↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the FOCAL Experimental Campaign

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within the floater's individual members. Consideration of local substructure loads is important for some floating designs, because the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the Focal Experimental Campaign: Preprint

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within its individual members. Consideration of local substructure loads is important for some floating designs, as the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

On Residual Stresses and Reference Temperatures in Thermomechanical Simulations of Photovoltaic Modules Using the Finite Element Method

Thermomechanical simulation of photovoltaic (PV) modules using the finite element method (FEM) is a useful tool to evaluate module design features in terms of structural integrity, reliability, and durability. One of the main challenges in the numerical modeling of a PV module is the incorporation of residual stresses induced by the manufacturing process. Modeling assumptions and abstractions are necessary to limit the model complexity and reduce the computational time. However, oversimplifications and incorrect assumptions can lead to erroneous numerical results. Unfortunately, much simulation work still neglects process-induced stresses. This can lead to incorrect predictions of the stress-strain history and erroneous conclusions during the design process. In this work, we review current modeling practices for incorporating process-induced stresses, and contrast numerical models that consider residual stresses with those that neglect them. We find that the simulation objective and available material properties dictate which process steps need to be modeled, and explore in depth the modeling of residual stresses induced by the lamination process. We demonstrate that a simplified cooldown procedure at the beginning of the simulation can increase the model accuracy and discuss appropriate choices for starting and reference temperatures in the finite element model.

14 SOLAR ENERGY↗

A classical model for three-body interactions in aqueous ionic systems

We present a classical induction model to evaluate the three-body ion–water–water (I–W–W) and water–water–water (W–W–W) interactions in aqueous ionic systems. The classical description of the induction energy is based on electrostatic distributed multipoles up to hexadecapole and distributed polarizabilities up to quadrupole–quadrupole on the O and H atoms of water. The monatomic ions were described by a point charge and a dipole–dipole polarizability, while for the polyatomic ions, distributed multipoles up to hexadecapole and distributed polarizabilities up to quadrupole–quadrupole were used. The accuracy of the classical model is benchmarked against an accurate dataset of 936 (I–W–W) and 2184 (W–W–W) three-body terms for 13 different monatomic and polyatomic cation and anion systems. The classical model shows excellent agreement with the reference second order Moller–Plesset and coupled-cluster single double and perturbative triple [CCSD(T)] three-body energies. The Root-Mean-Square-Errors (RMSEs) for monatomic cations, monatomic anions, and polyatomic ions were 0.29, 0.25, and 0.12 kcal/mol, respectively. The corresponding RMSE for 1744 CCSD(T)/aVTZ three-body (W–W–W) energies, used to train MB-pol, was 0.12 kcal/mol. The accuracy of the proposed classical model demonstrates that the three-body term for aqueous ionic systems can be accurately modeled classically. This approach provides a fast, efficient, and as-accurate path toward modeling the three-body term in aqueous ionic systems that is fully transferable across systems with different ions without the need to fit to tens of thousands of ab initio calculations for each ion to extend existing many-body force fields to interactions between water and ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale plasticity of geomaterials predicted via constrained optimization‐based granular micromechanics

Abstract A general framework to derive nonlinear elastic and elastoplastic material models from granular micromechanics is proposed, where a constraint‐based variational structure is introduced to classical grain contact‐based homogenization methods of hyperelasticity. Like the classical hyperelastic methods, reference solutions for closed‐form hyperelastic material models are analytically derived from the grain‐scale contact mechanics. However, unlike prior methods, the proposed homogenization framework defines closed‐form hyperelastoplastic material models that extend multiscale variational methods to granular plasticity. The proposed framework is used to develop novel granular micromechanics‐based macroscopic models for a Mises type solid, Drucker–Prager type plasticity, and grain‐contact cohesive‐debonding with a deviatorically and volumetrically coupled nonlinearly elastic response. Macroscopic plastic parameters and yield criteria are explicitly related to their microscale counterparts, for example, the friction coefficient governing intergranular slip. Numerical examples and comparison to measurements from the literature, including triaxial compaction of concrete, are provided to investigate model predictions and demonstrate calibration to experimental data.

Bryant, E. C.↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗