Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Competition of magnetocrystalline anisotropy of uranium layers and zigzag chains in UNi 0.34 Ge 2 single crystals

Structural and thermodynamic properties of single-crystalline UNi 1-x Ge 2 with x = 0.66 have been investigated by measuring magnetization, specific heat, and thermal expansion over a wide range of temperatures and magnetic fields. The measurements revealed the emergence of a long-range antiferromagnetic ordering of uranium magnetic moments below the Néel temperature T N = 45.5 (1) K and the existence of two easy axes in the studied compound, namely b and c, which correspond to the planes of the uranium zig-zag chains. A magnetic field applied along these two crystallographic directions induces in the system a first-order metamagnetic phase transition (from antiferromagnetic to field-polarized paramagnetism), and the width of the magnetic hysteresis associated with that transition reaches as much as 40 kOe at the lowest temperatures. A magnetic phase diagram developed from the experimental data showed that the metastable region associated with that magnetic hysteresis forms a funnel that narrows toward the N´eel point in a zero magnetic field. The four-layer Ising model has successfully predicted the colinear antiferromagnetic structure in UNi 0.34 Ge 2 (known from earlier reports), its magnetic phase diagram, and temperature and field variations of its magnetization. Moreover, it suggests that the first-order phase transition extends down to zero magnetic field, although it is barely detectable in the experiments performed in low magnetic fields. According to this model, the second-order phase transition occurs in the compound only in zero field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the neutron cross section on argon between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. Here we also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140ns-180ns, 120ns-140ns, 112ns-120ns, 104ns-112ns, 96ns-104ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin with statistical and systematic (syst) uncertainties: σ(146 MeV) = 0.60 $^{+0.14}_{-0.14}$ ±0.08(syst) b, σ(236 MeV) = 0.72 $^{+0.10}_{-0.10}$ ± 0.04(syst) b, σ(319 MeV) = 0.80 $^{+0.13}_{-0.12}$ ±0.040(syst) b, σ(404 MeV) = 0.74 $^{+0.14}_{-0.09}$ ±0.04(syst) b, σ(543 MeV) = 0.74 $^{±0.09}_{-0.09}$ ± 0.04(syst) b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

First Cosmology Results using Supernovae Ia from the Dark Energy Survey: Survey Overview, Performance, and Supernova Spectroscopy

We present details on the observing strategy, data-processing techniques, and spectroscopic targeting algorithms for the first three years of operation for the Dark Energy Survey Supernova Program (DES-SN). This five-year program using the Dark Energy Camera mounted on the 4 m Blanco telescope in Chile was designed to discover and follow supernovae (SNe) Ia over a wide redshift range (0.05 < z < 1.2) to measure the equation-of-state parameter of dark energy. We describe the SN program in full: strategy, observations, data reduction, spectroscopic follow-up observations, and classification. From three seasons of data, we have discovered 12,015 likely SNe, 308 of which have been spectroscopically confirmed, including 251 SNe Ia over a redshift range of 0.017 < z < 0.85. We determine the effective spectroscopic selection function for our sample and use it to investigate the redshift-dependent bias on the distance moduli of SNe Ia we have classified. The data presented here are used for the first cosmology analysis by DES-SN (“DES-SN3YR”), the results of which are given in Dark Energy Survey Collaboration et al. The 489 spectra that are used to define the DES-SN3YR sample are publicly available at https://des.ncsa.illinois.edu/releases/sn.

79 ASTRONOMY AND ASTROPHYSICS↗

The Influence of Residual Stress on Fatigue Crack Growth Rates in Stainless Steel Processed by Different Additive Manufacturing Methods

The properties and microstructure of Type 304L stainless steel produced by two additive manufacturing (AM) methods—directed energy deposition (DED) and powder bed fusion (PBF)—are evaluated and compared. Localized heating and steep temperature gradients of AM processes lead to significant residual stress and distinctive microstructures, which may be process-specific and influence mechanical behavior. Test data show that materials produced by DED and PDF have small differences in tensile strengths but clear differences in residual stress and microstructural features. Measured fatigue crack growth rates (FCGRs) for cracks propagating parallel to and perpendicular to the build directions differ between the two AM materials. To separate the influences of residual stress and microstructure, K-control test procedures with decreasing and constant stress intensity factor ranges are used to measure FCGRs in the near-threshold regime (crack growth rates ≤ 1 × 10 −8 m/cycle). Residual stress is quantified by the residual stress intensity factor, K res , measured by the online crack compliance method. Correcting the FCGR data for differences in K res brings results for specimens of the two AM materials into agreement with each other and with results for wrought specimens, when the latter are corrected for crack closure. Differences in microstructure and tensile strength have an insignificant influence on FCGRs in these tests.

additive manufacturing↗

A Measurement of the Eta Meson Radiative Decay Width via the Primakoff Effect

The ? meson is an interesting tool to study fundamental symmetries in Quantum Chromodynamics (QCD). In particular, its radiative decay width, ? p? Ñ ??q, is an important quantity that can be predicted in the framework of Chiral Perturbation Theory. A precision measurement of this quantity would provide critical inputs to understanding the mixing of the ? and ?1 mesons and extracting constants with wide-ranging applications in low-energy QCD. This decay width has been measured in the past using two different experimental techniques. The more popular technique utilized e`e´ collisions to produce ? mesons through electromagnetic interactions. Today, the Particle Data Group (PDG) averages the results of five such experiments to obtain their currently-accepted value of the decay width as: 0.515?0.018 keV. However the first measurement of this quantity was obtained from a fixed-target experiment that measured the cross section for photoproduction of ? mesons on a nuclear target via the Primakoff effect. Their result of 0.324?0.046 keV shows strong tension with the average of the collider measurements, motivating a new, high precision measurement using the Primakoff method. For this purpose, the PrimEx-eta experiment was conducted in Hall D of the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab). The data is currently being analyzed to measure the differential cross section for the photoproduction of ? mesons on a liquid, 4He target. Preliminary results obtained from the analysis of the first phase of the PrimEx-eta experiment show reasonable agreement with the currently-accepted PDG value of the radiative decay width. However, as will be discussed, there are many challenges to this precision measurement which must be studied before any results can be finalized and compared with previous measurements. In parallel to the ? decay width measurement, the PrimEx-eta experiment measured the total cross section for the fundamental, Quantum Electrodynamics (QED) process of Compton scattering from the atomic electrons inside the target. The results obtained from this measurement are in strong agreement with the next-to-leading order QED calculations, and the total combined uncertainties are below 3% for incident photon energies between 7-10 GeV. In addition to providing the first precision measurement of the total Compton scattering cross section within this beam energy range, this measurement verifies the capability of the PrimEx-eta experimental setup to perform absolute cross section measurements at forward angles, and serves as a reference process for the calibration of systematic uncertainties.

Smith, Andrew↗

Evaluation of the rheological and electrical percolation of high‐density polyethylene/carbon black composites using mathematical models

Abstract In this work, conductive polymer composites (CPCs) of bio‐based polyethylene (BioPe) containing different concentrations of carbon black (CB) were developed. By using oscillatory rheology analysis, a Newtonian plateau was observed in BioPe, and all BioPe/CB composites had a behavior of a pseudo‐solid and that composites with volume fractions ranging from 0.24 to 0.56 presented higher viscosity, storage, and loss modulus. This suggests the formation of a percolated network and by using the power‐law models, it was observed that the electrical percolation threshold was higher than the rheological percolation threshold. The electrical conductivity was measured using the four‐point probe method and a sigmoid model was used to predict the CPCs' electrical conductivity percolation threshold. The results indicated that the four‐point probe method presented satisfactory results according to the calculated standard deviations and voltage–current characteristics for each round of measurements considering the same ranging as used in rheology analysis. The analytical model used showed a coefficient of determination ( R 2 ) higher than 95%, allowing the prediction of the electrical conductivity of the CPC and the percolation threshold as a function of the volumetric fraction of the CB.

da SiIva, Moacy P.↗

Optimization of fluorescence and surface adsorption of citric acid/ethanolamine carbon nanoparticles for subsurface tracers

The tunable fluorescence and biocompatibility of fluorescent carbon nanoparticles (FCNs) makes them appealing tracers in geothermal, environmental, and clinical applications. Here, we address FCNs synthesized from reaction and pyrolysis of citric acid and ethanolamine. We examine the fluorescence and the adsorption of these FCNs as critical parameters that influence their use in applications. FCN fluorescence was observed to develop during pyrolysis and measured at pyrolysis temperatures ranging from 190 to 250 °C. Transmission electron microscopy shows that the FCN average diameter of approximately 13 nm is unaffected by pyrolysis temperature. However, pyrolysis temperature strongly affects fluorescence, which peaks at 210 °C. Here, the surface hydrophobicity of the FCNs increases with pyrolysis temperature as measured by retention on reverse phase chromatography. Together, these results suggest that particle surface functionalities provide both fluorescence and hydrophilicity, and that these surface functionalities are destroyed with excessive pyrolysis. To examine their surface adsorption, quartz crystal microbalance measurements demonstrate that pyrolysis temperature increases FCN adsorption on mineral surfaces. Surfaces with greater hydrophobicity show greater FCN adsorption. Adsorption is unaffected by the presence of mono- or divalent ions in solution. This suggests adsorption by hydrophobic interaction for the Fe 2 O 3 , SiO 2 , and AlSiO surfaces studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

High-Temperature Air Stability of Electrodeposited Copper Cobalt Oxide and Copper Manganese Oxide Absorber Coatings for Concentrating Solar Power

The solar absorptance of a thermal receiver surface significantly affects the photothermal conversion efficiency of concentrating solar power (CSP) plants. The stability of solar receivers and coatings applied to improve solar absorptance at high temperatures is critical for efficient and long-term operation. This study analyzes the high-temperature air stability of multiscale fractal textured electrodeposited copper manganese oxide and copper cobalt oxide solar receiver coatings over a range of temperatures. The study also investigates the effect of high temperature on phase stability, chemical and morphological evolution, and the optical properties of the two solar absorber materials. A computational model is developed to determine the absorptance of the textured absorbers and is shown to match the experimental measurements closely over a range of heat treatment temperatures from 450 °C to 850 °C and durations up to 100 h. Degradation curves and coating stability maps are developed from the study. Copper manganese oxide and copper cobalt oxide coatings exhibit good thermal stability up to ~815 °C and 630 °C, respectively, with minimal changes in their optical and structural properties with thermal efficiency greater than 90%. Furthermore, the study offers valuable insights into the high-temperature annealing effects on the optical and structural properties of multiscale copper alloyed coatings fabricated by electrodeposition and presents a means of designing the optimal temperature range for maximizing absorber efficiency in practical applications.

14 SOLAR ENERGY↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗

Hyper Suprime-Cam Year 3 results: Cosmology from galaxy clustering and weak lensing with HSC and SDSS using the emulator based halo model

We present cosmology results from a blinded joint analysis of cosmic shear, galaxy-galaxy weak lensing, and projected galaxy clustering, measured from the Hyper Suprime-Cam three-year (HSC-Y3) shape catalog and the Sloan Digital Sky Survey (SDSS) DR11 spectroscopic galaxy catalog—a cosmology analysis. We define luminosity-cut, and therefore nearly volume-limited, samples of SDSS galaxies to serve as the tracers of w p and as the lens samples for Δ⁢Σ in three spectroscopic redshift bins spanning the range 0.15± and Δ⁢Σ measurements, we use a single sample of about seven million source galaxies over 416 deg 2 , selected from HSC-Y3 based on having photometric redshifts (photo-z) greater than 0.75. The deep, high-quality HSC-Y3 data enable significant detections of the Δ⁢Σ signals, with integrated signal-to-noise ratio S/N~24 in the range 3≤R/[ℎ –1 Mpc]≤30 over the three lens samples. ξ ± has S/N ~19 in the range 8' ≤$\theta$ ≤5⁢0' and 30' ≤$\theta$ ≤15⁢0' for ξ + and ξ – , respectively. For cosmological parameter inference, we use the dark emulator package, combined with a halo occupation distribution prescription for the relation between galaxies and halos, to model w p and Δ⁢Σ down to quasinonlinear scales, and we estimate cosmological parameters after marginalizing over nuisance parameters. In our baseline analysis we employ an uninformative flat prior of the residual photo-z error, given by Π⁡(Δz ph )=$U$⁡(–1,1), to model a residual bias in the mean redshift of HSC source galaxies. Comparing the relative lensing amplitudes for Δ⁢Σ in the three redshift bins and for ξ ± with the single HSC source galaxy sample allows us to calibrate the photo-z parameter Δ⁢z ph to the precision of σ⁡(Δ⁢z ph )≃0.09. With these methods, we obtain a robust constraint on the cosmological parameters for the flat Λ⁢CDM model: S 8 =σ 8 ⁢(Ω m /0.3) 0.5 =$0.763^{+0.040}_{–0.036}$, or the best-constrained parameter given by $S^{'}_{8}$ = σ 8 ⁢(Ω m /0.3) 0.22 =0.721±0.028, determined with about 4% fractional precision. Based on multidimensional tension metrics, HSC-Y3 data exhibits about 2.5σ tension with the cosmological constraint inferred by Planck for the Λ⁢CDM model, and hints at a nonzero residual photo-z bias implying that the true mean redshift of the HSC galaxies at z ≳0.75 is higher than that implied by the original photo-z estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

How Austenitic Is a Martensitic Steel Produced by Laser Powder Bed Fusion? A Cautionary Tale

Accurate phase fraction analysis is an essential element of the microstructural characterization of alloys and often serves as a basis to quantify effects such as heat treatment or mechanical deformation. Additive manufacturing (AM) of metals, due to the intrinsic nonequilibrium solidification and spatial variability, creates additional challenges for the proper quantification of phase fraction. Such challenges are exacerbated when the alloy itself is prone to deformation-induced phase transformation. Using commonly available in-house X-ray diffraction (XRD) and electron backscatter diffraction (EBSD) and less commonly used synchrotron-based high-energy X-ray diffraction, we characterized nitrogen-atomized 17-4 precipitation-hardening martensitic stainless steel, a class of AM alloy that has received broad attention within the AM research community. On the same build, our measurements recovered the entire range of reported values on the austenite phase fractions of as-built AM 17-4 in literature, from ≈100% martensite to ≈100% austenite. Aided by Calphad simulation, our experimental findings established that our as-built AM 17-4 is almost fully austenitic and that in-house XRD and EBSD measurements are subject to significant uncertainties created by the specimen’s surface finish. Hence, measurements made using these techniques must be understood in their correct context. Our results carry significant implications, not only to AM 17-4 but also to AM alloys that are susceptible to deformation-induced structure transformation and suggest that characterizations with less accessible but bulk sensitive techniques such as synchrotron-based high energy X-ray diffraction or neutron diffraction may be required for proper understanding of these materials.

17-4 steel↗

Measurement of the central exclusive production of charged particle pairs in proton-proton collisions at $\sqrt{s}$ = 200 GeV with the STAR detector at RHIC

We report on the measurement of the Central Exclusive Production of charged particle pairs h+h- (h = π, K, p) with the STAR detector at RHIC in proton-proton collisions at $\sqrt{s}$ = 200 GeV. The charged particle pairs produced in the reaction pp → p' + h + h - + p' are reconstructed from the tracks in the central detector and identified using the specific energy loss and the time of flight method, while the forward-scattered protons are measured in the Roman Pot system. Exclusivity of the event is guaranteed by requiring the transverse momentum balance of all four final-state particles. Differential cross sections are measured as functions of observables related to the central hadronic final state and to the forward-scattered protons. They are measured in a fiducial region corresponding to the acceptance of the STAR detector and determined by the central particles’ transverse momenta and pseudorapidities as well as by the forward-scattered protons’ momenta. This fiducial region roughly corresponds to the square of the four-momentum transfers at the proton vertices in the range 0.04 GeV 2 < -t 1 , -t 2 < 0.2 GeV 2 , invariant masses of the charged particle pairs up to a few GeV and pseudorapidities of the centrally-produced hadrons in the range |η| < 0.7. The measured cross sections are compared to phenomenological predictions based on the Double Pomeron Exchange (DPE) model. Structures observed in the mass spectra of π + π - and K + K - pairs are consistent with the DPE model, while angular distributions of pions suggest a dominant spin-0 contribution to π + π - production. For π + π - production, the fiducial cross section is extrapolated to the Lorentz-invariant region, which allows decomposition of the invariant mass spectrum into continuum and resonant contributions. The extrapolated cross section is well described by the continuum production and at least three resonances, the f 0 (980), f 2 (1270) and f 0 (1500), with a possible small contribution from the f 0 (1370). Fits to the extrapolated differential cross section as a function of t 1 and t 2 enable extraction of the exponential slope parameters in several bins of the invariant mass of π + π - pairs. These parameters are sensitive to the size of the interaction region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Burn mode signatures enabled by high dynamic range fusion reaction history

The evolution of the fusion burn of a compressed inertial confinement fusion (ICF) implosion gives information about the evolution of the temperature, mass, and volume of the hot spot. Currently, the fusion reaction history has been measured with about a decade of dynamic range, giving information about just the peak of the fusion burn. There are proposals for extending the dynamic range to 1000×, measuring the rising edge of the burn earlier in time. Using fusion hot spot theory and a set of ICF simulations, we identify and categorize different stages of fusion burn and what signatures could be measured. For ice layered implosions, the details, conditions, and dynamics of the fusion burn propagation could be observed. For double shell and OMEGA scale implosions, the evolution of the final compression and rebounding shock before ignition could be observed. Higher dynamic range expands investigation into the logarithmic derivative, α, as a signature of various mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Speed of Sound Measurements of Binary Mixtures of Difluoromethane (R-32) with 2,3,3,3-Tetrafluoropropene (R-1234yf) or trans-1,3,3,3-Tetrafluoropropene (R-1234ze(E)) Refrigerants

In this article, sound speed data measured using a dual-path pulse-echo instrument are reported for binary mixtures of difluoromethane (R-32) with 2,3,3,3-tetrafluoropropene (R-1234yf) or trans-1,3,3,3-tetrafluoropropene (R-1234ze(E)). The sound speed is reported at two compositions for each binary mixture of approximately (0.33/67) and (0.67/0.33) mole fraction at temperatures between 230 K and 345 K. Data are reported from pressures slightly above the bubble point to 12 MPa for R-32/1234yf mixtures to avoid potential polymerization reactions and to 53 MPa for the R-32/1234ze(E) mixtures. The mean uncertainty of the sound speed data are less than 0.1% of the measured value where uncertainties at individual state points range from 0.04% to 0.5% of the measured value as the conditions approach the mixture critical region. The reported data are compared to available Helmholtz-energy-explicit EOS included in REFPROP and all systems studied have average absolute deviations greater than 2%. The comparisons show that further adjustments to the mixture models are needed to provide a reasonable representation of the data within its experimental uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗