Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Measurement of transverse Jc profiles of coated conductors using a magnetic knife of permanent magnets

The transverse J{sub c} distribution in YBCO coated conductors was measured non-destructively with high resolution using a 'magnetic knife' made of permanent magnets. The method utilizes the strong depression of J{sub c} in applied magnetic fields. A narrow region of low (including zero) magnetic field, in a surrounding higher field, is moved transversely across the sample in order to reveal the critical-current density distribution. The net resolution of this device is approximately 65 {micro}m, and the J{sub c} resolution is better than 0.5%. A Fourier series inversion process was used to determine the transverse J{sub c} distribution in the sample. The J{sub c} profile was correlated with other sample properties of coated conductors prepared by pulsed laser deposition. Because of its straight-forward and inexpensive design, this J{sub c} imaging technique can be a powerful tool for quality control in coated-conductor production.

36 MATERIALS SCIENCE↗

Investigations of high mobility single crystal chemical vapor deposition diamond for radiotherapy photon beam monitoring

The intrinsic properties of diamond make this material theoretically very suitable for applications in medical physics. Until now ionization chambers have been fabricated from natural stones and are commercialized by PTW, but their fairly high costs and long delivery times have often limited their use in hospital. The properties of commercialized intrinsic polycrystalline diamond were investigated in the past by many groups. The results were not completely satisfactory due to the nature of the polycrystalline material itself. In contrast, the recent progresses in the growth of high mobility single crystal synthetic diamonds prepared by chemical vapor deposition (CVD) technique offer new alternatives. In the framework of the MAESTRO project (Methods and Advanced Treatments and Simulations for Radio Oncology), the CEA-LIST is studying the potentialities of synthetic diamond for new techniques of irradiation such as intensity modulated radiation therapy. In this paper, we present the growth and characteristics of single crystal diamond prepared at CEA-LIST in the framework of the NoRHDia project (Novel Radiation Hard CVD Diamond Detector for Hadrons Physics), as well as the investigations of high mobility single crystal CVD diamond for radiotherapy photon beam monitoring: dosimetric analysis performed with the single crystal diamond detector in terms of stability and repeatability of the response signal, signal to noise ratio, response speed, linearity of the signal versus the absorbed dose, and dose rate. The measurements performed with photon beams using radiotherapy facilities demonstrate that single crystal CVD diamond is a good alternative for air ionization chambers for beam quality control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Green strength of zirconium sponge and uranium dioxide powder compacts

Zirconium metal sponge is compacted into rectangular or cylindrical shapes using hydraulic presses. These shapes are stacked and electron beam welded to form a long electrode suitable for vacuum arc melting and casting into solid ingots. The compact electrodes should be sufficiently strong to prevent breakage in handling as well as during vacuum arc melting. Usually, the welds are strong and the electrode strength is limited by the green strength of the compacts, which constitute the electrode. Green strength is also required in uranium dioxide (UO{sub 2}) powder compacts, to withstand stresses during de-tensioning after compaction as well as during ejection from the die and for subsequent handling by man and machine. The strengths of zirconium sponge and UO{sub 2} powder compacts have been determined by bending and crushing respectively, and Weibul moduli evaluated. The green density of coarse sponge compact was found to be larger than that from finer sponge. The green density of compacts from lightly attrited UO{sub 2} powder was higher than that from unattrited category, accompanied by an improvement in UO{sub 2} green crushing strength. The factors governing green strength have been examined in the light of published literature and experimental evidence. The methodology and results provide a basis for quality control in metal sponge and ceramic powder compaction in the manufacture of nuclear fuel.

36 MATERIALS SCIENCE↗

TU-C-201-02: Clinical Implementation of HDR: Afterloader and Applicator Selection

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-03: The Use of Checklists and Audit Tools for Safety and QA

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-01: Clinical Implementation of HDR: A New User’s Perspective

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

Building America

Builders generally use a 'spec and purchase' business management system (BMS) when implementing energy efficiency. A BMS is the overall operational and organizational systems and strategies that a builder uses to set up and run its company. This type of BMS treats building performance as a simple technology swap (e.g. a tank water heater to a tankless water heater) and typically compartmentalizes energy efficiency within one or two groups in the organization (e.g. purchasing and construction). While certain tools, such as details, checklists, and scopes of work, can assist builders in managing the quality of the construction of higher performance homes, they do nothing to address the underlying operational strategies and issues related to change management that builders face when they make high performance homes a core part of their mission. To achieve the systems integration necessary for attaining 40% + levels of energy efficiency, while capturing the cost tradeoffs, builders must use a 'systems approach' BMS, rather than a 'spec and purchase' BMS. The following attributes are inherent in a systems approach BMS; they are also generally seen in quality management systems (QMS), such as the National Housing Quality Certification program: Cultural and corporate alignment, Clear intent for quality and performance, Increased collaboration across internal and external teams, Better communication practices and systems, Disciplined approach to quality control, Measurement and verification of performance, Continuous feedback and improvement, and Whole house integrated design and specification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intensity-Modulated Radiotherapy for Head-and-Neck Cancer in the Community Setting

Purpose: To review outcomes with intensity-modulated radiation therapy (IMRT) in the community setting for the treatment of nasopharyngeal and oropharyngeal cancer. Methods and Materials: Between April 2003 and April 2007, 69 patients with histologically confirmed cancer of the nasopharynx and oropharynx underwent IMRT in our practice. The primary sites included nasopharynx (11), base of tongue (18), and tonsil (40). The disease stage distribution was as follows: 2 Stage I, 11 Stage II, 16 Stage III, and 40 Stage IV. All were treated with a simultaneous integrated boost IMRT technique. The median prescribed doses were 70 Gy to the planning target volume, 59.4 Gy to the high-risk subclinical volume, and 54 Gy to the low-risk subclinical volume. Forty-five patients (65%) received concurrent chemotherapy. Toxicity was graded according to the Radiation Therapy Oncology Group toxicity criteria. Progression-free and overall survival rates were estimated with the Kaplan-Meier product-limit method. Results: Median duration of follow-up was 18 months. The estimated 2-year local control, regional control, distant control, and overall survival rates were 98%, 100%, 98%, and 90%, respectively. The most common acute toxicities were dermatitis (32 Grade 1, 32 Grade 2, 5 Grade 3), mucositis (8 Grade 1, 33 Grade 2, 28 Grade 3), and xerostomia (0 Grade 1, 29 Grade 2, 40 Grade 3). Conclusions: Intensity-modulated radiotherapy in the community setting can be accomplished safely and effectively. Systematic internal review systems are recommended for quality control until sufficient experience develops.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Tests for the Detection of the LINAC Irradiation Field Using PIN Diodes

The employment of the technology of semiconductor detectors, in the medical physics environment is of great importance due to its versatility and dependability. In this work we present the first results and the experimental arrangement employed with PIN diodes that are conditioned for the measurement of the field of irradiation of a lineal accelerator (LINAC) used in radiotherapy. In our tests we used a PIN photodiode. In former experiments, this diode presented a response to the intensity of the applied field when it was exposed to an X-ray beam in medical and industrial radiography equipments. This diode is a low cost and easy acquisition one in the field. These characteristics transform it into a serious candidate as detector to be used in electronic arrangements for the detection of radiation fields in radio-therapy with X-rays. Experiments were designed to obtain the response of this diode when it was exposed to X-ray beams of a LINAC used in radiotherapy. Firstly the tests were carried out for a 6 MeV photon beam with a source to surface distance (SSD) of 100 cm, obtaining very encouraging results. We seek to carry out tests for more energy values in order to obtain the energy response of this detector as a radiation sensor device. This device could be applied in the design of working tools, for example, for the quality control in procedures of radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ characterization of material extrusion printing by near-infrared spectroscopy

Material extrusion printing of reactive resins and inks present a unique challenge due to the time-dependent nature of the rheological and chemical properties they possess. As a result, careful print optimization or process control is important to obtain consistent, high quality prints via additive manufacturing. Here, we present the design and use of a near-infrared (NIR) flow through cell for in situ chemical monitoring of reactive resins during printing. Differences between in situ and off-line benchtop measurements are presented and highlight the need for in-line monitoring capability. Additionally, in-line extrusion force monitoring and off-line post inspection using machine vision is demonstrated. By combining NIR and extrusion force monitoring, it is possible to follow cure reaction kinetics and viscosity changes during printing. When combined with machine vision, the ability to automatically identify and quantify print artifacts can be incorporated on the printing line to enable real-time, artificial intelligence-assisted quality control of both process and product. Together, these techniques form the building blocks of an optimized closed-loop process control strategy when complex reactive inks must be used to produce printed hardware.

36 MATERIALS SCIENCE↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arroyo Seco Improvement Program ( 2019 Annual Report)

The Arroyo Seco Improvement Program is being carried out at Sandia National Laboratories, California in order to address erosion and other streambed instability issues in the Arroyo Seco as it crosses the Sandia National Laboratories, California. The work involves both repair of existing eroded areas, and habitat enhancement. This work is being carried out under the requirements of Army Corps of Engineers permit 2006-400195S and California Regional Water Quality Control Board, San Francisco Bay Region Water Quality Certification Site No. 02-01-00987.

54 ENVIRONMENTAL SCIENCES↗

Arroyo Seco Improvement Program Annual Report for 2020

The Arroyo Seco Improvement Program is being carried out at Sandia National Laboratories, California in order to address erosion and other streambed instability issues in the Arroyo Seco as it crosses the Sandia National Laboratories, California. The work involves both repair of existing eroded areas, and habitat enhancement. This work is being carried out under the requirements of Army Corps of Engineers permit 2006-400195S and California Regional Water Quality Control Board, San Francisco Bay Region Water Quality Certification Site No. 02-01-C0987.

54 ENVIRONMENTAL SCIENCES↗

Metallographic techniques for evaluation of Thermal Barrier Coatings produced by Electron Beam Physical Vapor Deposition

Thermal Barrier Coatings (TBC) produced by Electron Beam Physical Vapor Deposition (EB-PVD) are primarily applied to critical hot section turbine components. EB-PVD TBC for turbine applications exhibit a complicated structure of porous ceramic columns separated by voids that offers mechanical compliance. Currently there are no standard evaluation methods for evaluating EB-PVD TBC structure quantitatively. This paper proposes a metallographic method for preparing samples and evaluating techniques to quantitatively measure structure. TBC samples were produced and evaluated with the proposed metallographic technique and digital image analysis for columnar grain size and relative intercolumnar porosity. Incorporation of the proposed evaluation technique will increase knowledge of the relation between processing parameters and material properties by incorporating a structural link. Application of this evaluation method will directly benefit areas of quality control, microstructural model development, and reduced development time for process scaling.

36 MATERIALS SCIENCE↗

3D imaging of semiconductor components by discrete laminography

X-ray laminography is a powerful technique for quality control of semiconductor components. Despite the advantages of nondestructive 3D imaging over 2D techniques based on sectioning, the acquisition time is still a major obstacle for practical use of the technique. In this paper, we consider the application of Discrete Tomography to laminography data, which can potentially reduce the scanning time while still maintaining a high reconstruction quality. By incorporating prior knowledge in the reconstruction algorithm about the materials present in the scanned object, far more accurate reconstructions can be obtained from the same measured data compared to classical reconstruction methods. We present a series of simulation experiments that illustrate the potential of the approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an {sup 241}Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: EGSnrc-based dosimetric study of the BEBIG {sup 60}Co HDR brachytherapy sources

Purpose: The purpose of this work is to calculate two-dimensional (2D) dose rate distributions around the BEBIG (Eckert and Ziegler, BEBIG GmbH, Germany) models GK60M21 (old) and Co0.A86 (new) {sup 60}Co high dose rate brachytherapy sources in an unbounded liquid water phantom. The study includes calculation of absorbed dose to water-kerma ratio D/K around the BEBIG sources and a {sup 60}Co point source in water. A comparison is made with previously published data. Methods: The EGSnrcMP Monte Carlo code system is used to calculate the absorbed dose and water-kerma in water and air-kerma strength in vacuum. EGSnrcMP-based user codes such as EDKnrc, FLURZnrc, and DOSRZnrc are employed in the work. Results: The value of D/K reaches a maximum of 1.040{+-}0.002 for the {sup 60}Co point source (constant between 3.6 and 4.5 mm from the source) and 1.076{+-}0.002 for the BEBIG sources (constant between 2.6 and 3.2 mm along the transverse axis of the sources). Dose rate data for the new and old sources are comparable to published data for radial distances r>0.5 cm. Differences up to 9% are observed at points close to the source (r=0.25 cm). In addition for the new source, compared to previously published data, dose rate data are higher by 14% along the longitudinal axis where the source cable is connected. Dose rate differences on the longitudinal axis ({theta}=180 deg.) of this source are explained by varying the length of the simulated source cable. Conclusions: The 2D rectangular data set calculated in the present work could be considered for quality control on radiotherapy treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗