Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Centrifugal Pump Model for System Codes for Advanced NPP Designs

In this document, a homologous model and one-dimensional line model for centrifugal pump are described to provide the theoretical background of a pump model to be developed in system-level codes. Input and output parameters are proposed, along with a summary of the governing equations for each model. Furthermore, hydraulic performance degradation of centrifugal pump is also modeled in the homologous pump model. This document suggests that system codes provide a homologous and one-dimensional line model for centrifugal pumps, allowing the users to choose the model that best fits their purposes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems

The Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems offers an approximation of geomembrane lining system costs for pumped storage hydropower (PSH) reservoirs. Geomembrane lining systems have been used around the world for over 60 years for the construction of dams and reservoirs. Although geomembrane lining systems have found widespread use in the construction of canals and waste containment systems, they have not been utilized in the construction of new PSH facilities in the United States since the Mount Elbert PSH powerplant in Colorado. For this reason, PSH developers in the United States expressed the need for a tool that would allow them to estimate the costs of geomembrane lining systems for their PSH projects. To meet this need, the Cost Model for Pumped Storage Hydropower Geomembrane Lining Systems was developed by Oak Ridge National Laboratory with support from Argonne National Laboratory and Stantec, Inc. This Cost Model will enable PSH developers to develop a preliminary estimate of the cost of geomembrane lining systems and to better understand different reservoir lining options and their cost and performance characteristics, thus enabling them to make informed decisions related to preferred reservoir lining systems for their PSH projects.

DeNeale, Scott [Oak Ridge National Laboratory (ORN↗

Reservoir Lining for Pumped Storage Hydropower: Scoping Study of Geomembrane Lining Systems

This report summarizes the results of a scoping study performed to research the use of geomembrane lining systems for pumped storage hydropower (PSH) reservoirs. The study consisted of a literature review for pertinent and publicly available information about geomembrane lining materials and their use in dams, reservoirs, and PSH as well as an assessment of the applicability of geomembrane lining systems to PSH reservoirs.

13 HYDRO ENERGY↗

A Critical Literature Review of Defrost Technologies for Heat Pumps and Refrigeration Systems

When the operating conditions are extremely cold and humid and the surface temperature of the heat exchanger well below the freezing point (lower than the dew point temperature of the air) moisture from the air stream will freeze on the surface after condensation and the frost will start growing. The frost growth degrades the performance of the system considerably. It hinders the airflow and increases the pressure drop through the coil which means more fan power is requires for to maintain the desired flow rate. With reduced flow rate due to the increase of pressure drop, system’s capacity drops rapidly. In the case of heat pump the capacity of the evaporator decreases due to the airflow drop, which reduces the overall heating capacity and coefficient of performance of the heat pump. Additionally, the frost layer increases the thermal resistance to the heat transfer between the air and refrigerant. The reduction in airflow and increased thermal resistance reduces the heat energy extracted by the evaporator and decreases the heat pump capacity and efficiency. Similar process is observed for the cooling coils of commercial refrigeration system where the frost growth can dramatically reduce the system capacity. Once the performance reaches its minimum acceptable stage, a defrost process is introduced to remove the frost layer and to achieve the performance at the start of the cycle. The frost defrost process is repeated continuously. Overall the frost growth is highly undesired phenomena which can cause considerable reduction in performance of the system.

42 ENGINEERING↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

MEMS based pumped liquid cooling systems for micro/nano spacecraft thermal control

The electronic and other payload power densities in future micro/nano spacecraft are expected to exceed 25 Watts/cm(sup 2) and require advanced thermal control concepts and technologies to keep their payload within allowable temperature limits. This paper presents background on the need for pumped liquid cooling systems for future micro/nano spacecraft and results from this ongoing experimental investigation.

cooling system thermal control microspacecraft↗

Electromagnetic Pumps for Conductive-Propellant Feed Systems

Prototype electromagnetic pumps for use with lithium and bismuth propellants were constructed and tested. Such pumps may be used to pressurize future electric propulsion liquid metal feed systems, with the primary advantages being the compactness and simplicity versus alternative pressurization technologies. Design details for two different pumps are described: the first was designed to withstand (highly corrosive) lithium propellant, and t he second was designed to tolerate the high temperature required to pump liquid bismuth. Both qualitative and quantitative test results are presented. Open-loop tests demonstrated the capability of each device to electromagnetically pump its design propellant (lithium or bismuth). A second set of tests accurately quantified the pump pressure developed as a function of current. These experiments, which utilized a more easily handled material (gallium), demonstrated continuously-adjustable pump pressure levels ranging from 0-100 Torr for corresponding input current levels of 0-75 A. While the analysis and testing in this study specifically targeted lithium and bismuth propellants, the underlying design principles should be useful in implementing liquid metal pumps in any conductive-propellant feed system.

Markusic, Thomas E.↗

Groundwater Pump and Treat System Optimization Report U.S. DOE NNSA Pantex Plant, Texas

This document details the approach and presents the results for the optimization of the perched groundwater pump and treat (P&T) systems at the Pantex Plant, located in the Texas panhandle (Figure 1.1). Recommendations from the second Five-Year Review (FYR) for the Pantex Plant (HGL, 2018) and objectives specified in the 2007 Record of Decision (ROD) are the basis of the optimization effort.

54 ENVIRONMENTAL SCIENCES↗

A pumped two-phase cooling system for spacecraft

A pumped, two-phase heat-transport system is being developed for possible use for temperature control of scientific instruments on future NASA missions. As compared to a single-phase system, this two-phase system can maintain tighter temperature control with less pumping power. A laboratory model of the system has been built and tested. The measured heat transfer coefficients were approximately the same as in heat pipes, 220 Btu/hr-sq ft-F, as compared to 25 Btu/hr-sq ft-F for single-phase liquid flow. Heat shearing between experiments has been demonstrated wherein vapor generated in the cold plate of an active experiment was condensed in a cold, unheated experiment. System stability has been observed. However, additional development is needed. The use of non-azeotropic mixtures of coolants appears especially promising as a simple way to determine exit quality and thus control the flow rates to prevent dryout.

Ollendorf, S.↗

Flight Operation of a Pump-Fed Liquid-Hydrogen Fuel System

A pump-fed liquid-hydrogen fuel system was developed and flight tested in a B57 bomber. The aircraft was flown to an altitude of 50,000 feet and a Mach number of 0.75 with JP-4 fuel in both engines. One engine was then switched to hydrogen operation for approximately 11 minutes. The liquid-hydrogen pump used for these flights was a five-cylinder positive-displacement type submerged in the bottom of the hydrogen tank. The hydrogen flow regulator was able to maintain a constant engine speed even though pump speed and discharge pressure oscillated.

David B. Fenn↗

Vein-style air pumping tube and tire system and method of assembly

An air pumping tube and tire system and method of assembling is provided in which a tire groove is formed to extend into a flexing region of a tire sidewall and a complementary air pumping tube inserts into the tire groove. In the green, uncured air pumping tube condition, one or more check valves are assembled into the air pumping tube through access shafts and align with an internal air passageway of the air pumping tube. Plug components of the system enclose the check valves in the air pumping tube and the check valve-containing green air pumping tube is then cured.

42 ENGINEERING↗

Large-capacity pump vaporizer for liquid hydrogen and nitrogen

Pump vaporizer system delivers 500 standard cubic feet per minute of hydrogen or nitrogen, one system delivers both gases. Vacuum-jacketed pump discharges liquid hydrogen or liquid nitrogen into vaporizing system heated by ambient air. Principal characteristics of the flow and discharge system, pump, and vaporizer are given.

Hauser, J. A.↗

Use of Systems Engineering in Repurposing Coal-Fired Power Plants with Malta Pumped Thermal Energy Storage System

he electric sector across North America is facing a transition. Both economics and policy decisions have pointed towards a broad retirement of fossil assets across markets. Owners are facing the problem of how to evolve the base of the electric sector from fossil asset to greener alternative. Coal-fired power plants built the modern electricity grid. Their rotating machinery are the beating heart of the grid, providing essential resiliency and reliability services. Power plant retirements are disruptive to plant workforces and cause outsized impacts on surrounding communities. The transition from thermal power plants that use rotating machinery to generate electricity (e.g., coal- and gas-fired plants) to variable, inverter-based generation (e.g., solar and wind) is affecting the reliability of the electric grid. Grid operators and national regulators have issued warnings about known and anticipated risk. In 2021, Malta Inc. was awarded a Department of Energy (DOE) grant to study how to integrate a Malta 100MW Pumped Heat Energy Storage (PHES) system with a retiring coal-fired power plant to meet emissions requirements, retain plant workforces, preserve communities, and maintain grid reliability. This presentation provides a summary of this study, focusing on how systems engineering approach was used to arrive at a proposed design concept that met multiple objectives and requirements. There will be three main parts for this presentation. The first part of the presentation will focus on how different systems engineering was applied for this work. In particular, the following areas: stakeholder engagement, site selection process, developing requirements and use cases for the integrated system, defining the system and its boundary, coming up with different system architecture/option, performing a techno-economic analysis to compare the different options and down selection of the preferred option, will be discusses. For these areas, discussion on the decisions on how much breadth and depth to go into each area will be provided. These discussions provide good insights into how to apply systems engineering. The second part of the presentation will provide a deeper dive into the two recommended integration options that repurpose coal-fired power plants with Malta PHES system. The comparison of the two options and general guidance of how to choose an option will be provided. This is particularly useful for utilities who are facing coal-plant retirements. The two options will be compared based on its performance (such as power output, efficiency), complexity, and cost. The social impact on local communities of the two options will also be discussed. The final part of the presentation will discuss the impact that this work has had, including Malta Inc. being invited to the White House to discuss progress and outcomes of this work with the Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization. In summary, this presentation aims to provide a showcase of how sy

25 ENERGY STORAGE↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗