Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Electron-Nanobunch-Width-Dominated Spectral Power Law for Relativistic Harmonic Generation from Ultrathin Foils

Relativistic high-order harmonic generation from solid-density plasma offers a compact source of coherent ultraviolet and x-ray light. For solid targets much thinner than the laser wavelength, the plasma thickness can be tuned to increase conversion efficiency; a reduction in total charge allows for balancing the laser and plasma driving forces, producing the most effective interaction. Unlike for semi-infinite plasma surfaces, in this study we find that for ultrathin foil targets the dominant factor in the emission spectral shape is the finite width of the electron nanobunches, leading to a power-law exponent of approximately 10/3. Ultrathin foils produce higher-efficiency frequency conversion than solid targets for moderately relativistic (1 0 <40) interactions and also provide unique insight into how the trajectories of individual electrons combine and interfere to generate reflected attosecond pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Third Fermi Large Area Telescope Catalog of Gamma-Ray Pulsars

We present 294 pulsars found in GeV data from the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope. Another 33 millisecond pulsars (MSPs) discovered in deep radio searches of LAT sources will likely reveal pulsations once phase-connected rotation ephemerides are achieved. A further dozen optical and/or X-ray binary systems colocated with LAT sources also likely harbor gamma-ray MSPs. This catalog thus reports roughly 340 gamma-ray pulsars and candidates, 10% of all known pulsars, compared to ≤11 known before Fermi. Half of the gamma-ray pulsars are young. Of these, the half that are undetected in radio have a broader Galactic latitude distribution than the young radio-loud pulsars. The others are MSPs, with six undetected in radio. Overall, ≥236 are bright enough above 50 MeV to fit the pulse profile, the energy spectrum, or both. For the common two-peaked profiles, the gamma-ray peak closest to the magnetic pole crossing generally has a softer spectrum. The spectral energy distributions tend to narrow as the spindown power $\dot{E}$ decreases to its observed minimum near 10 33 erg s -1 , approaching the shape for synchrotron radiation from monoenergetic electrons. We calculate gamma-ray luminosities when distances are available. Our all-sky gamma-ray sensitivity map is useful for population syntheses. The electronic catalog version provides gamma-ray pulsar ephemerides, properties, and fit results to guide and be compared with modeling results.

79 ASTRONOMY AND ASTROPHYSICS↗

Diverse simulations of time-resolved photoluminescence in thin-film solar cells: A SnO 2 /CdSe y Te 1-y case study

Time-resolved photoluminescence (TRPL) is widely used to measure carrier lifetime in thin-film solar cell absorbers. However, the injection dependence of data and frequent non-exponential decay shapes complicate the interpretation. Here, we develop a numerical model to simulate injection-dependent TRPL measurements in a SnO 2 /CdSe y Te 1-y case study solar cell structure, considering parameters of interest to researchers in industry and academia. Previous simulations have shown that, in low injection, excess electrons and holes injected by the laser pulse are rapidly separated in the electric field formed by the pn junction. As a result, at early times, the PL signal can decay faster than the Shockley-Read-Hall lifetime in the absorber bulk (t_bulk). Prior simulations have shown that the charge stored in the junction can slowly leak out to affect decays at late times. However, it has not been clear if and to what degree charge storage can affect the slopes extracted from TRPL decays - t_2 - commonly cited as the TRPL-measured lifetime. Here, we show that charge storage can, in some cases, result in t_2 values that substantially overestimate t_bulk. Previous simulations indicate that high injection conditions can screen the junction field and minimize charge separation. Here, we show that continued injection increases can drive down t_2 below t_bulk as radiative recombination becomes dominant. We catalog charge storage and radiative recombination impacts for a diverse set of material parameters and compare results to double-heterostructure models.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,S↗

Continuous wave room temperature operation of the 2 $μ$m GaSb-based photonic crystal surface emitting diode lasers

Continuous wave room temperature operation of 2 μm GaSb-based photonic-crystal surface-emitting diode lasers has been realized. The deep etched square mesa devices showed threshold current densities of 500 A/cm 2 at 20 °C. The epi-side down mounted lasers generated above 10 mW of output power in the continuous wave regime and tens of milliwatts in pulses from the 200 × 200 μm 2 aperture. Here, the breakthrough in the device performance parameters was achieved thanks to a highly homogeneous air-pocket retaining epitaxial regrowth process optimized for a specifically designed antimonide diode laser heterostructure. The nanofabrication method utilizing low temperature atomic hydrogen surface cleaning yielded low disorder square lattice of droplet-shaped voids covered by uniform p-cladding layer. The laser emission spectrum as well as near/far field patterns demonstrated peculiar features presumably linked to deformation of the void shape during regrowth and formation of the array of filaments.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On the analysis of signal peaks in pulse-height spectra

The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient Mesoscopic Immiscibility, Viscosity Anomaly, and High Internal Pressure at the Semiconductor–Metal Transition in Liquid Ga 2 Te 3

Gallium tellurides appear to be promising phase-change materials (PCMs) of the next generation for brain-inspired computing and reconfigurable optical metasurfaces. They are different from the benchmark PCMs because of sp 3 gallium hybridization in both cubic Ga 2 Te 3 and amorphous pulsed laser deposition (PLD) films. Liquid Ga 2 Te 3 also shows a viscosity η(T) anomaly just above melting when η(T) first increases and only then starts decreasing. We used high-energy X-ray diffraction to observe a transient mesoscopic immiscibility that suggested dense metallic liquid droplets in a semiconducting melt. The η(T) shape was consistent with this finding. A vanishing first sharp diffraction peak that also shifts to a higher Q indicates a high internal pressure in the metallic melt, which produces a remarkable asymmetry of the Ga–Te nearest neighbor distances and is reminiscent of high-pressure rhombohedral Ga 2 Te 3 . Finally, the observed phenomena provide a realistic scenario for a fast, multilevel SET–RESET response, which also unravels similar trends in the purported density-driven liquid polyamorphism of water, phosphorus, sulfur, and other materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Trapped-Exciton Radiative Recombination in β–Ga 2 O 3 : Impact of Two Concurrent Nonradiative Auger Processes

The peculiarities of radiative and nonradiative processes associated with self-trapped intrinsic eXcitons in the excited β-Ga 2 O 3 crystals are studied via time-resolved techniques of induced absorption, transient grating, and photoluminescence (PL) at room temperature. The excitation above the bandgap is produced by laser pulses with linear light polarization parallel and orthogonal in the (–201) and (001) planes. We elucidate that the nonradiative recombination rate occurring in the eXciton prevails over its radiative emission rate in a wide range of free carrier concentration composed of excited and equilibrium electrons. Hence, the nonradiative recombination has no effect on the strong anisotropy and the shape of the eXciton emission band. However, we find out that the conventional ABC model of electron effective lifetime is insufficient for explanation of the excitation dependences. Inclusion of two nonradiative Auger mechanisms in a modified ABC formula provides excellent agreement of these dependences. We conclude that the trap-assisted Auger process is in proportion to the free electron density with coefficient B = 1.1 × 10 –11 cm 3 /s and appears at low/intermediate excitation, while the triple-particle Auger process is in proportion to Δn 2 with coefficient C = 8 × 10 –30 cm 6 /s and appears at high excitation conditions. The transition between two Auger mechanisms is accompanied by a rise of the eXciton diffusivity in preferred crystallographic directions where the radiative PL intensity is maximal. The diffusion length LD in these directions can reach values ~300 nm, but, at high excitations, LD becomes limited by Auger lifetimes. These findings pave the way for the implementation of self-trapped eXcitons into specific optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hybrid model predictive control techniques for safety factor profile and stored energy regulation while incorporating NBI constraints

Abstract A novel hybrid Model Predictive Control (MPC) algorithm has been designed for simultaneous safety factor ( q ) profile and stored energy ( w ) control while incorporating the pulse-width-modulation constraints associated with the neutral beam injection (NBI) system. Regulation of the q -profile has been extensively shown to be a key factor for improved confinement as well as non-inductive sustainment of the plasma current. Simultaneous control of w is necessary to prevent the triggering of pressure-driven magnetohydrodynamic instabilities as the controller shapes the q profile. Conventional MPC schemes proposed for q -profile control have considered the NBI powers as continuous-time signals, ignoring the discrete-time nature of these actuators and leading in some cases to performance loss. The hybrid MPC scheme in this work has the capability of incorporating the discrete-time actuator dynamics as additional constraints. In nonlinear simulations, the proposed hybrid MPC scheme demonstrates improved q -profile+ w control performance for NSTX-U operating scenarios.

Physics↗

Fundamental bandwidth limits and shaping of frequency-modulated combs

Frequency-modulated (FM) combs based on active cavities like quantum cascade lasers have recently emerged as promising light sources in many spectral regions. Unlike passive modelocking, which generates amplitude modulation using the field’s amplitude, FM comb formation relies on the generation of phase modulation from the field’s phase. They can therefore be regarded as a phase-domain version of passive modelocking. However, while the ultimate scaling laws of passive modelocking have long been known—Haus showed in 1975 that pulses modelocked by a fast saturable absorber have a bandwidth proportional to effective gain bandwidth—the limits of FM combs have been much less clear. Here, we show that FM combs based on fast gain media are governed by the same fundamental limits, producing combs whose bandwidths are linear in the effective gain bandwidth. Not only do we show theoretically that the diffusive effect of gain curvature limits comb bandwidth, but we also show experimentally how this limit can be increased. By adding carefully designed resonant-loss structures that are evanescently coupled to the cavity of a terahertz laser, we reduce the curvature and increase the effective gain bandwidth of the laser, demonstrating bandwidth enhancement. Our results can better enable the creation of active chip-scale combs and be applied to a wide array of cavity geometries.

47 OTHER INSTRUMENTATION↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Electrochemical Deposition with Redox Replacement of Lanthanum with Uranium in Molten LiCl-KCl

Electrochemical recovery of dilute concentrations of actinides from spent nuclear fuel would reduce the longevity of storing high-level nuclear waste. Electrochemical deposition with redox replacement (EDRR) is used in a molten salt medium for the selective electrochemical recovery of uranium in the presence of excess concentrations of lanthanum. In each EDRR cycle, after a short electrodeposition pulse, the deposited lanthanum is spontaneously replaced by uranium at open circuit. After repeated cycles, uranium metal was obtained on a tungsten electrode immersed in LiCl-KCl melt that contained 1 wt.% lanthanum chloride – 0.15 wt.% uranium 4+ chloride. Here, scanning electron microscopy and energy dispersive X-ray spectroscopy analysis revealed uranium particles approximately 0.5 - 1 μm with well-defined rectangular shapes; and with 20 – 60 times more uranium recovered on the surface of the electrode than lanthanum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ablating nanoscale pores in crystalline quartz using laser-induced micro-plasmas in tri-layer structures

We demonstrate a novel approach for achieving rapid, consistent, and controllable micro-pore fabrication in single-crystalline quartz. These micro-pores are essential for applications in biology, i.e., studying ion channels in general and mechano-sensitive channels (MSC) in particular. The fabrication process consists of direct material ablation using pulsed UV light from a 193 nm excimer laser. These pulses ablate single-crystalline quartz chips by burning a laser-induced plasma in a tri-layer structure. Controllable plasma confinement and thus pore size is achieved by sandwiching a thin layer of a selected organic solution between the quartz chip and different substrates. This solution causes the confined micro-plasma to generate special ablation conditions, to create uniformly sized and shaped nanopores.

36 MATERIALS SCIENCE↗

Modeling Nondestructive Defect Detection in Additively Manufactured Metallic Structures for Nuclear Applications

The future of quickly, economically produced metallic nuclear reactor parts with minimal supply-chain dependence lies in Laser Powder Bed Fusion (LPBF) Additive Manufacturing (AM): a 3D printing method involving laser melting and net shaping stainless steel and Inconel metallic powder into a solid structure. However, intrinsic features in LPBF frequently leads to the formation of materials defects, such as pores, within 3D printed structures. As safe long-term use in energy applications requires knowledge of all relevant defects before deployment in a reactor, we must develop methods for nondestructive detection of these defects. We are investigating Pulsed Thermal Tomography (PTT), which is a non-contact nondestructive imaging method scalable to arbitrary structure size. Thermal tomography (TT) is a computational method for 3D spatial reconstruction of material thermal effusivity from flash or pulsed thermography temperature data cube. Thermography data cube consists of 2D surface temperature measurements at different times. The objective of the present work is to investigate limits on defect detection in AM metallic structures with PTT. To this effect, we modeled PTT with COMSOL heat transfer computer simulations. We developed a layered media COMSOL simulation consisting of a Stainless Steel 316 (SS316) plate with an internal layer of un-sintered SS316 powder. Thermophysical properties of the powder layer were modeled with equivalent volume mixing model. To account for partial sintering at the boundary of the defect, the transition between solid and powder layers was modeled as a Gaussian. Using data from COMSOL simulations, we reconstructed depth-dependent thermal effusivity, which allowed defect visibility estimation. A series of parametric studies determined that at 1mm depth, 50µm is the smallest detectable defect. In addition, classification of the defects which can lead to early fatigue of the metallic structure in a reactor is briefly discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory tests of CO2 laser collective Thomson scattering for measurements of ion temperature in the divertor

Collective Thomson scattering (CTS) is a diagnostic method that measures the ion velocity distribution of a plasma. CO2 laser CTS measurements are challenging because of the inherently small Doppler broadening and scattering signals that are difficult to detect. We implemented a heterodyne detection scheme to measure spectrum changes of less than a GHz. To maximize the collected light at small scattering angles, we designed a unique light collection approach consisting of a customized conical-shaped (axicon) lens with a hole in the center. The axicon lens is used to collect the scattered light emitted within an annular cross-section from the scattering volume while the probe beam is passed through the hole at the center of the lens. The performance of the heterodyne detection scheme and annular collection approach was demonstrated using a Transverse Excited Atmospheric pressure CO2 laser with a pulse energy of 160 mJ at λ = 10.59 µm.

Instruments & Instrumentation↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗