Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Symmetry-dependent broadening parameters for methane

Experimental results for the pressure-broadened linewidths gamma of methane are presented and compared with theoretical results. A solar Fourier transform spectrometer with spectral resolving power of about one million was used together with a 6-m base length multitraversal absorption cell. Pressures were determined to an accuracy of + or - 0.2 Torr by means of a capacitance manometer. The pressuring gases were N2, H2, and He. Results are presented for numerical averages of all linewidths corresponding to a given tetrahedral symmetry for J = 0-6. For all cases studied, gamma(E) is found to be substantially less than gamma(A), and gamma(A) is found to be near to, but significantly smaller than, gamma(F). Relative inelastic cross sections calculated for argon scattering from methane are compared with relative pressure-broadened linewidths measured in several experiments involving methane and other gases.

Fox, K.↗

Diagnostics of vector magnetic fields

It is shown that the vector magnetic fields derived from observations with a filter magnetograph will be severely distorted if the spatially unresolved magnetic structure is not properly accounted for. Thus the apparent vector field will appear much more horizontal than it really is, but this distortion is strongly dependent on the area factor and the temperature line weakenings. As the available fluxtube models are not sufficiently well determined, it is not possible to correct the filter magnetograph observations for these effects in a reliable way, although a crude correction is of course much better than no correction at all. The solution to this diagnostic problem is to observe simultaneously in suitable combinations of spectral lines, and/or use Stokes line profiles recorded with very high spectral resolution. The diagnostic power of using a Fourier transform spectrometer for polarimetry is shown and some results from I and V spectra are illustrated. The line asymmetries caused by mass motions inside the fluxtubes adds an extra complication to the diagnostic problem, in particular as there are indications that the motions are nonstationary in nature. The temperature structure appears to be a function of fluxtube diameter, as a clear difference between plage and network fluxtubes was revealed. The divergence of the magnetic field with height plays an essential role in the explanation of the Stokes V asymmetries (in combination with the mass motions). A self consistent treatment of the subarcsec field geometry may be required to allow an accurate derivation of the spatially averaged vector magnetic field from spectrally resolved data.

Stenflo, J. O.↗

Rotary transformer design with fixed magnetizing and/or leakage inductances

A design algorithm is considered for transformers that must transfer electric power across a rotating interface. Among other features, this procedure allows the designer to minimize either weight or losses for either a fixed magnetizing inductance or a fixed leakage inductance. Numerical results are included to indicate the design trade-offs between various parameters.

Stuart, T. A.↗

Comparison of high temperature, high frequency core loss and dynamic B-H loops of a 2V-49Fe-49Co and a grain oriented 3Si-Fe alloy

The design of power magnetic components such as transformers, inductors, motors, and generators, requires specific knowledge about the magnetic and electrical characteristics of the magnetic materials used in these components. Limited experimental data exists that characterizes the performance of soft magnetic materials for the combined conditions of high temperature and high frequency over a wide flux density range. An experimental investigation of a 2V-49-Fe-49Co (Supermendur) and a grain oriented 3 Si-Fe (Magnesil) alloy was conducted over the temperature range of 23 to 300 C and frequency range of 0.1 to 10 kHz. The effects of temperature, frequency, and maximum flux density on the core loss and dynamic B-H loops for sinusoidal voltage excitation conditions are examined for each of these materials. A comparison of the core loss of these two materials is also made over the temperature and frequency range investigated.

Wieserman, W. R.↗

Comparison of high temperature, high frequency core loss and dynamic B-H loops of a 2V-49Fe-49Co and a grain oriented 3Si-Fe alloy

The design of power magnetic components such as transformers, inductors, motors, and generators, requires specific knowledge about the magnetic and electrical characteristics of the magnetic materials used in these components. Limited experimental data exists that characterizes the performance of soft magnetic materials for the combined conditions of high temperature and high frequency over a wide flux density range. An experimental investigation of a 2V-49-Fe-49Co (Supermendur) and a grain oriented 3 Si-Fe (Magnesil) alloy was conducted over the temperature range of 23 to 300 C and frequency range of 0.1 to 10 kHz. The effects of temperature, frequency, and maximum flux density on the core loss and dynamic B-H loops for sinusoidal voltage excitation conditions are examined for each of these materials. A comparison of the core loss of these two materials is also made over the temperature and frequency range investigated.

Wieserman, W. R.↗

Performance of High-frequency High-flux Magnetic Cores at Cryogenic Temperatures

Three magnetic powder cores and one ferrite core, which are commonly used in inductor and transformer design for switch mode power supplies, were selected for investigation at cryogenic temperatures. The powder cores are Molypermalloy Core (MPC), High Flux Core (HFC), and Kool Mu Core (KMC). The performance of four inductors utilizing these cores has been evaluated as a function of temperature from 20 C to -180 C. All cores were wound with the same wire type and gauge to obtain equal values of inductance at room temperature. Each inductor was evaluated in terms of its inductance, quality (Q) factor, resistance, and dynamic hysteresis characteristics (B-H loop) as a function of temperature and frequency. Both sinusoidal and square wave excitations were used in these investigations. Measured data obtained on the inductance showed that both the MPC and the HFC cores maintain a constant inductance value, whereas with the KMC and ferrite core hold a steady value in inductance with frequency but decrease as temperature is decreased. All cores exhibited dependency, with varying degrees, in their quality factor and resistance on test frequency and temperature. Except for the ferrite, all cores exhibited good stability in the investigated properties with temperature as well as frequency. Details of the experimental procedures and test results are presented and discussed in the paper.

Gerber, Scott S.↗

Mechanisms underlying very-low-frequency RR-interval oscillations in humans

BACKGROUND: Survival of post-myocardial infarction patients is related inversely to their levels of very-low-frequency (0.003 to 0.03 Hz) RR-interval variability. The physiological basis for such oscillations is unclear. In our study, we used blocking drugs to evaluate potential contributions of sympathetic and vagal mechanisms and the renin-angiotensin-aldosterone system to very-low-frequency RR-interval variability in 10 young healthy subjects. METHODS AND RESULTS: We recorded RR intervals and arterial pressures during three separate sessions, with the patient in supine and 40 degree upright tilt positions, during 20-minute frequency (0.25 Hz) and tidal volume-controlled breathing after intravenous injections: saline (control), atenolol (0.2 mg/kg, beta-adrenergic blockade), atropine sulfate (0.04 mg/kg, parasympathetic blockade), atenolol and atropine (complete autonomic blockade), and enalaprilat (0.02 mg/kg, ACE blockade). We integrated fast Fourier transform RR-interval spectral power at very low (0.003 to 0.03 Hz), low (0.05 to 0. 15 Hz), and respiratory (0.2 to 0.3 Hz) frequencies. Beta-adrenergic blockade had no significant effect on very-low- or low-frequency RR-interval power but increased respiratory frequency power 2-fold. ACE blockade had no significant effect on low or respiratory frequency RR-interval power but modestly (approximately 21%) increased very-low-frequency power in the supine (but not upright tilt) position (P<0.05). The most profound effects were exerted by parasympathetic blockade: Atropine, given alone or with atenolol, abolished nearly all RR-interval variability and decreased very-low-frequency variability by 92%. CONCLUSIONS: Although very-low-frequency heart period rhythms are influenced by the renin-angiotensin-aldosterone system, as low and respiratory frequency RR-interval rhythms, they depend primarily on the presence of parasympathetic outflow. Therefore the prognostic value of very-low-frequency heart period oscillations may derive from the fundamental importance of parasympathetic mechanisms in cardiovascular health.

Non-NASA Center↗

On the Computation of High Order Rys Quadrature Weights and Nodes

Since its introduction in 1976, the Rys Quadrature method has proven a very attractive method for evaluating electron repulsion integrals for calculations using Gaussian type orbitals. Since then, there have been considerable refinements of the method, but at it's core, Gaussian weights and nodes are used to exactly evaluate using a numerical approach to the transform integral. One of the powers of the Rys Quadrature method is the relative ease in evaluating integrals involving functions of high angular momentum. In this work we report on the complete resolution of these numerical difficulties, and we have easily computed accurate quadrature weights and nodes up to order 101. All calculations were carried out using 128-bit precision.

Computation↗

A 294 GHz 0.47m W Caterpillar amplifier based transmitter in 65 nm CMOS for THz data-links

A fully integrated CMOS THz transmitter for short range data-links is presented which provides 0.47 mW of output power to 294 GHz. The output frequency is derived from a 147 GHz on-chip LO and fully differential caterpillar power amplifier combined with a transformer coupled frequency doubler. The transmitter is integrated with an on-chip dipole antenna for use in THz communication systems and consumes a total of 258 mW.

Chang, Mau-Chung Frank↗

Occurrence of Large Geomagnetically Induced Currents Within the EPRI SUNBURST Monitoring Network

Space weather, a natural hazard, can adversely impact human technological assets. High-voltage electric power transmission grids constitute one of the most critical technological systems vulnerable to space weather driven geomagnetically induced currents (GICs). One of the major challenges pertaining to the study of GICs over the continental United States has been the availability of GIC measurements, which are critical for validation of geoelectric field and power flow models, for example. In this study, we analyze GIC measurements collected at 17 Electrical Power Research Institute (EPRI) SUNBURST transformer locations across the United States for which a GIC value of 10 A or greater was recorded. This data set includes 52 individual geomagnetic storms with Kp index 6 and above during the period from 2010 to 2021. The analysis confirms that there is a good correlation between the number of geomagnetic storms per year and the number of recorded GIC events. Our results also show that about 76% of the top 17 GIC events are associated with the storm main phase, while only 24% are attributed to storm sudden commencements. In addition, it is shown, for the first time, that mid-latitude positive bays can cause large GICs over the continental United States. Finally, this study shows that the largest measured GIC event in the data set was associated with a localized intense dB/dt structure, which could be attributed to substorm activity.

Chigomezyo M. Ngwira↗

Circuit for providing variable waveform excitation

A circuit for testing an electronic component, such as a transformer, includes at least two power supplies and at least two H bridge circuits. A first H bridge circuit is conductively coupled in parallel to a first power supply. A second H bridge circuit is conductively coupled in parallel to a second power supply. The second H bridge circuit includes one or more anti-series diodes for preventing current from the first power supply from passing through the second H bridge circuit to the second power supply. The first H bridge circuit and the second H bridge circuit are configured to conductively couple to the electronic component for providing a voltage with a predefined waveform to the electronic component.

Beddingfield, Richard B.↗

A BAPTA employing rotary transformers, stepper motors and ceramic ball bearings

The utilization of rotary transformers as an alternative to slip rings for the power transfer from solar panels to a satellite's main body could be advantageous, especially if an ac bus system is taken into consideration. Different approaches with main emphasis on the electromagnetic design were investigated and showed efficiencies of up to 99% with a 3 kW power capability. A solidly preloaded pair of ball bearings with ceramic balls assures proper transformer air gaps and acceptable torque changes over temperature and temperature gradients. The bearing and power transfer assembly is driven by a direct drive stepper motor with inherent redundancy properties and needs no caging mechanism.

Auer, W.↗

Modelling a single phase voltage controlled rectifier using Laplace transforms

The development of a 20 kHz, AC power system by NASA for large space projects has spurred a need to develop models for the equipment which will be used on these single phase systems. To date, models for the AC source (i.e., inverters) have been developed. It is the intent of this paper to develop a method to model the single phase voltage controlled rectifiers which will be attached to the AC power grid as an interface for connected loads. A modified version of EPRI's HARMFLO program is used as the shell for these models. The results obtained from the model developed in this paper are quite adequate for the analysis of problems such as voltage resonance. The unique technique presented in this paper uses the Laplace transforms to determine the harmonic content of the load current of the rectifier rather than a curve fitting technique. Laplace transforms yield the coefficient of the differential equations which model the line current to the rectifier directly.

Kraft, L. Alan↗

Tapless Voltage Regulating Transformer. Final Report

Voltage regulation is a common practice in power grid operation. The conventional voltage regulation methods have been facing ever increasing challenges as the penetration of renewable generations deepens in the grid. The intermittent nature of the renewable sources may result in sudden rise or drop of power generation, possibly breaking the generation-load balance. A lack of adequate voltage control not only affects the power quality but is detrimental to the system operation with the potential for large economic losses. Most conventional voltage regulation devices rely on mechanical tap changers to impose the regulation in a step-wise manner. Although sufficient for normal operations, the mechanical tap changers can be easily worn out in the challenging situations created by renewables. In this project, a novel technology called tapless voltage regulating transformer (TAREX) was proposed and investigated. It has the potential to excel at addressing the new voltage regulation challenges and replace the conventional regulating transformers. TAREX is based on the concept of the saturable-core reactor (SCR). The voltage of a TAREX can be smoothly and continuously regulated in a reasonable range by using a low rating power electronics based controller. It uses control of the transformer core magnetization to regulate the voltage on the windings, and thus eliminates the mechanical tap changer. This project is to prove the principle of TAREX, understand the voltage regulation mechanism, and preliminarily understand its impacts on the power systems through modeling, prototyping, and testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2020 International Conference on Smart Grids and Energy Systems (SGES)

This paper is concerned about phasor-based linear state estimation of three-phase power grids which contain non transposed lines and unsymmetrical branches. It builds upon our previous work where the linear measurement equations were decoupled into three independent sets via the symmetrical component transformation. Such a transformation may however not fully decouple the measurement equations if there are nontransposed transmission lines and unsymmetrical branches in the system. This paper addresses this limitation by deriving additive terms that compensate for the remaining coupling between sequence measurements after the application of the conventional transformation. It will be shown that general unbalanced threephase power grids can still be transformed into three decoupled subsystems and their state estimation solution can be obtained in parallel by the proposed approach.

Khalili, Ramtin↗