Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “potential capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characterization and Testing of Amidoxime-Based Adsorbent Materials to Extract Uranium from Natural Seawater

Extraction of uranium (U) from seawater for use as a nuclear fuel is a significant challenge due to the low concentration of U in seawater (~3.3 ppb) and difficulties to selectively extract U from the background of major and trace elements in seawater. The Pacific Northwest National Laboratory (PNNL)’s Marine Sciences Laboratory (MSL) has been serving as a marine test site for determining performance characteristics (adsorption capacity, adsorption kinetics, and selectivity) of novel amidoxime-based polymeric adsorbents developed at Oak Ridge National Laboratory (ORNL) under natural seawater exposure conditions. This manuscript describes the performance of three formulations (38H, AF1, AI8) of amidoxime-based polymeric adsorbents produced at ORNL in MSL’s ambient seawater testing facility. The adsorbents were produced in two forms, fibrous material (40-100 mg samples) and braided material (5-10 g samples), and exposed to natural seawater using flow-through columns and recirculating flumes. All three formulations demonstrated high 56 day uranium adsorption capacity (>3 g U/kg adsorbent). The AF1 formulation had the best uranium adsorption performance, with a 56 day capacity of 3.9 g U/ kg adsorbent, a saturation capacity of 5.4 g U/kg adsorbent, and ~25 days half-saturation time. The two exposure methods, flowthrough columns and flumes, were demonstrated to produce similar performance results, providing confidence that the test methods were reliable, that scaling up from 10’s of mg quantities of exposure in flow-through columns to gram quantities in flumes produced similar results, and confirm that the manufacturing process produces a homogeneous adsorbent. Adsorption kinetics appear to be element specific, with half-saturation times ranging from minutes for the major cations in seawater, to 8-10 weeks for V and Fe. Reducing the exposure time provides a potential pathway to improve the adsorption capacity of U by reducing the V/U ratio on the adsorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High capacity Li/Ni rich Ni-Ti-Mo oxide cathode for Li-ion batteries

With the rising cost and insufficient supply of cobalt, the thrust for cobalt-free cathode materials with the high specific capacity to build Li-ion batteries has increased significantly. Using nickel as the prime electrochemical active species, we have synthesized a new-class of materials with the combination of ordered and disordered phases. To obtain high capacity and electrical charge neutrality, stoichiometry of cations designed in a way that it forms Li/Ni rich Ni-Ti-Mo oxide materials. In addition to conventional capacity from redox activity of transition metals, partially reversible oxygen redox reaction also contributes to electrochemical activity and thus results in unusual high capacity. The resultant cathode materials of LiNi 0.5 Ti 0.5 O 2 -(Li 4 MoO 5 ) 0.8 and LiNiO 2 mixture phases reach the specific capacity of 240 mAh/g. Detailed soft X-ray absorption spectroscopy and electron microscopy are used to reveal the crystal phases in this system and trace changes in the Ni 2+ /Ni 4+ redox couple during charge-discharge processes. Finally, such comprehensive analysis of ordered-disordered oxides suggesting potentiality to develop high-capacity cobalt-free cathodes.

25 ENERGY STORAGE↗

An Opportunistic Wireless Charging System Design for an On-Demand Shuttle Service: Preprint

System right-sizing is critical to implementation of in-motion wireless power transfer (WPT) for electric vehicles. This study introduces a modeling tool, WPTSim, which uses one-second speed, location, and road grade data from an on-demand employee shuttle in operation to simulate the incorporation of WPT at fine granularity. Vehicle power and state of charge are simulated over the drive cycle to evaluate potential system designs. The required battery capacity is determined based on the rated power at a variable number of charging locations. Adding just one WPT location can more than halve the battery capacity needed. Many configurations are capable of being self sustaining with WPT, while others benefit from supplemental stationary charging.

30 DIRECT ENERGY CONVERSION↗

Tailoring conductive networks within hollow carbon nanospheres to host phosphorus for advanced sodium ion batteries

The formidable sustainability challenges in advancing energy storage technologies call for game-changing research in battery designs. The previous pursuing of novel cathode materials with high redox potentials impedes the vast applications due to the simultaneous electrolyte decomposition at high potentials, though they are expected to deliver high specific capacities. Eventually, people start thinking in an opposite way, desirable anode materials with low redox potentials can also own high specific capacities. Among all the promising candidates, phosphorus-based anodes in sodium ion batteries (SIBs) have received considerable attention owing to the low cost and relatively high natural abundance of phosphorus. More importantly, phosphorus can store three sodium atoms and enable a high theoretical capacity of 2596 mAh g -1 , which overwhelms any other SIB anode currently available. However, the poor electronic conductivity and large volume change of phosphorus during cycling severely deteriorate battery performance. The most widely used strategy is to confine phosphorus within well-designed carbon hosts. Here, we thereby introduce a new type of porous hollow carbon with conductive-network interior as phosphorus host, which not only improves the electrical conductivity, but also creates enough interior surface for maximizing phosphorus utilization and shortening the ion's diffusion distance, compared to those conventional hollow carbon hosts. Therefore, the as-prepared red phosphorus-carbon spheres composites (RP/CS) exhibit superior rate performance (similar to 1083 mAh g -1 at 4 A g -1 , similar to 837 mAh g -1 even at 8 A g -1 ) and excellent cycle life (1027 mAh g -1 at 4 A g -1 more than 2000 cycles).

25 ENERGY STORAGE↗

Rooftop Solar Photovoltaic Technical Potential in the United States

How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Evaluation of Rooftop Solar Potential in Chernihiv and Lviv, Ukraine, and Efficacy of High-Resolution 3D Data Digital Twins [Slides]

NREL evaluated rooftop solar photovoltaic (PV) siting opportunities in the cities of Chernihiv and Lviv, Ukraine, leveraging very-high-resolution 3D elevation data to calculate technical potential. The study assessed total rooftop solar capacity and annual energy production. In Chernihiv and Lviv, 116,503 buildings were analyzed for their rooftop solar potential. The buildings in the study areas include a mixture of residential, commercial, and industrial buildings, characterized by diverse roof shapes and sizes. The total estimated rooftop solar capacity is 332 MWDC in Chernihiv and 873 MWDC in Lviv with annual energy production up to 376.2 GWhDC in Chernihiv and 995.5 GWhDC in Lviv. This accounting provides a clear estimate of the potential rooftop solar installations that could be realized under optimal conditions, considering both technical constraints and the geographic distribution of available rooftop space. Related to Russia's invasion of Ukraine, NREL estimates loss from buildings damaged or destroyed of 2,754 buildings, 20.15 MWDC of capacity, and 22,869 MWhDC of annual energy production in Chernihiv as well as a loss of 1,316 buildings, 34.49 MWDC of capacity, and 39,369 MWhDC of annual energy production in Lviv. The study also assessed the feasibility of adapting this methodology on a national scale using either simulated digital surface models (DSMs) or a digital twin approach. While the very-high-resolution DSM provided more precise results, the simulated DSM demonstrated reasonable accuracy for broader applications in modeling aggregated distributed solar supply. The feasibility of using a digital twin for Ukraine's national rooftop solar potential is considered promising, with certain limitations in areas with highly variable building stock and heavy war damage.

14 SOLAR ENERGY↗

CarbonSAFE Phase I: Integrated CCS Pre-Feasibility – Northwest Gulf of Mexico (Final Research Performance Progress Report)

Offshore storage achieves two major objectives for the US commercial large scale CCS deployment: 1. Adding large capacity to serve local regional, and potentially broader objectives 2. Lowering risk by providing storage with one public owner, away from population, with no conflict with water resources and reduced concern about induced seismicity. A high-concentration CO 2 source was identified as the top candidate for the project and going forward with the CarbonSAFE Phase II proposal. The top-rated source is the NET Power facility in Houston (La Porte), Texas. A manuscript based on analysis of results from the two-stage survey conducted in eight selected Texas counties was submitted to the International Journal of Greenhouse Gas Control on August 21, 2018. A primary confining interval (seal) is associated with MFS9 (biochronozone Amphistegina B) which can reach a thickness of up to 250 m. However, the Amphistegina B confining interval thins considerably in the onshore direction. Consequently, the most suitable portion of the Miocene section for future CO 2 sequestration in the study area is considered to be the offshore area where Amphistegina B is thickest. Based on three models for capacity assessment, the study proposes a base case for the High Island 10-L Field in which 9 wells operated for 12 years each completed into 4 zones will emplace a total of 150MMT of CO 2 with wells placed in the water leg where all the plume will slowly migrate into the structural trap is feasible in terms of geology and engineering. The 10-L Field was assessed in more detail than other examined oil and gas fields in the study area in order to look at some specifics about how initial future CCS projects might be accomplished in the favorable GoM of the US region and expand the sites to a larger set to experiment with matching all the possible sources to sinks. The 10-L site is large enough to accept CO 2 from multiple sinks; the expanded sinks are estimated to be large enough to accept all the CO 2 from the region plus some from outside the region. A number of uncertainties were identified. The largest and most consequential uncertainty is the cost of offshore pipelines in the study setting, which impacts the conditions where CO 2 transport would be by ship versus the cases where pipeline would be preferred. Ships are preferred for small volumes and short durations; pipelines for larger volumes and long duration. Additional work is needed to advance the maturity of multiple sinks available, to continue outreach to industries and the public, and to develop realistic source opportunities. The study demonstrates that industrial source clusters connected to a transport hub delivering CO 2 to a nearby storage complex is the most cost-effective and improved way to de-carbonize industrial activities, particularly, in an expected low-carbon and increasing carbon price environmental. The feasibility of the new business models should be based on the best use of the existing infrastructure and strategically build on new supporting infrastructure to drive down the costs of large-scale CCS deployment. Assessing the pre-feasibility of the commercial implementation of a CCS cluster and hub in the GoM energy ecosystem, our study links these elements successfully through an optimized combination (minimum cost) of CO 2 sources on land with offshore storage. Offshore storage achieves two major objectives for the US commercial large scale CCS deployment: 1. Adding large capacity to serve local regional, and potentially broader objectives 2. Lowering risk by providing storage with one public owner, away from population, with no conflict with water resources and reduced concern about induced seismicity.

54 ENVIRONMENTAL SCIENCES↗

Multiyear Simulations of the Martian Water Cycle with the Ames General Circulation Model

Mars atmosphere is carbon dioxide dominated with non-negligible amounts of water vapor and suspended dust particles. The atmospheric dust plays an important role in the heating and cooling of the planet through absorption and emission of radiation. Small dust particles can potentially be carried to great altitudes and affect the temperatures there. Water vapor condensing onto the dust grains can affect the radiative properties of both, as well as their vertical extent. The condensation of water onto a dust grain will change the grain s fall speed and diminish the possibility of dust obtaining high altitudes. In this capacity, water becomes a controlling agent with regard to the vertical distribution of dust. Similarly, the atmosphere s water vapor holding capacity is affected by the amount of dust in the atmosphere. Dust is an excellent green house catalyst; it raises the temperature of the atmosphere, and thus, its water vapor holding capacity. There is, therefore, a potentially significant interplay between the Martian dust and water cycles. Previous research done using global, 3-D computer modeling to better understand the Martian atmosphere treat the dust and the water cycles as two separate and independent processes. The existing Ames numerical model will be employed to simulate the relationship between the Martian dust and water cycles by actually coupling the two cycles. Water will condense onto the dust, allowing the particle's radiative characteristics, fall speeds, and as a result, their vertical distribution to change. Data obtained from the Viking, Mars Pathfinder, and especially the Mars Global Surveyor missions will be used to determine the accuracy of the model results.

R M Haberle↗

Semiconducting Zn x Mo 3 S 13 -GO Chalcocarbogel: A High-Capacity and Stable Sulfur-Equivalent Conversion-Based Electrode for Lithium-Ion Batteries

Lithium–sulfur batteries with a sulfur electrode offer a theoretical capacity of ∼1672 mAh g –1 , but rapid capacity loss mainly constrains their practical application. This work introduces a semiconducting and amorphous Zn x Mo 3 S 13 -GO (x = 0.5) chalcocarbogel sulfur-equivalent electrode with superior capacity and stability for lithium-ion batteries (LIBs). The Zn x Mo 3 S 13 -GO is synthesized in solution under ambient conditions, and its local structure contains S–S, M-Q (M = Mo, Zn; Q = S, O), C–S, and Mo–Mo bonding motifs with Mo coordination environment closely related to Mo 3 S 13 anions, as determined by X-ray photoelectron spectroscopy, synchrotron X-ray scattering, X-ray absorption spectroscopy, and ab initio molecular dynamics simulations. The Li/Zn x Mo 3 S 13 -GO cell offers an initial discharge capacity of 1019 mAh g –1 at a rate of C/3. After the activation cycles, the Li/Zn x Mo 3 S 13 -GO cell demonstrates good cycling stability, retaining a discharge capacity of 519.4 mAh g –1 after 250 cycles with ∼99.98% Coulombic efficiency and excellent rate capabilities. Moreover, it provides an initial discharge capacity of ∼574 mAh g –1 and maintains a retention capacity of 279 mAh g –1 at 1C after 625 cycles. The Lewis acidic Zn 2+ ion enhances the Lewis basic polysulfide anchoring ability and reduces the dissolution of polysulfides produced during the redox process through Zn–S covalent interaction, while the semiconducting and amorphous structure of the chalcocarbogel increases the electrical and ionic conductivity. Furthermore, this work highlights chalcocarbogels’ potential for developing high-capacity and stable electrodes for LIBs.

25 ENERGY STORAGE↗

Revealing the potential of nickel zinc ferrite: Facile synthesis and cost-effective anode for lithium-ion batteries

The increasing demand for lithium-ion batteries (LIBs) underscores the need for cost-effective alternative anode materials to ensure efficient Li-ion storage, given their pivotal role in various industries. This research focuses on the facile synthesis of nickel zinc ferrite (NZFO: Ni 0.65 Zn 0.35 Fe 2 O 4 ) and conducts comprehensive electrochemical analyses to evaluate its potential as a high-capacity alternative anode material for LIBs. The NZFO-CMR [sodium carboxymethyl cellulose (2%) and styrene-butadiene rubber (1%)] exhibited an initial delithiated capacity of ∼1232 mA h g −1 and maintained a stable capacity of around 358 mA h g −1 , along with an average Coulombic efficiency of 99.6% over 200 cycles. Cyclic voltammetry analysis revealed that Li-ion insertion was predominantly governed by ion diffusion, and the consistent correlation observed in electrochemical impedance spectroscopy spectra indicated stable electrochemical behavior throughout cycling. The facile synthesis approach and reasonable electrochemical performance of NZFO suggest its potential as an alternative anode material for advancing LIB's technology.

25 ENERGY STORAGE↗

Stabilization xLi{sub 2}MnO{sub 3}{sm_bullet}(1-x)LiMO{sub 2} electrode surfaces (M=Mn, Ni, Co) with mildly acidic, fluorinated solutions.

It has been demonstrated previously that Li{sub 2}MnO{sub 3}-stabilized LiMO{sub 2} electrodes [xLi{sub 2}MnO{sub 3} {sm_bullet} (1?x)LiMO{sub 2}, M=Mn, Ni, Co] can provide anomalously high electrochemical capacities ({approx}250 mAh/g) if charged to high potentials (>4.6 V). High-voltage charging results in an irreversible capacity loss on the initial charge/discharge cycle; it also damages the electrode surface, leading to a high cell impedance. In this paper, we report that preconditioning 0.1Li{sub 2}MnO{sub 3} {sm_bullet} 0.9LiMn{sub 0.256}Ni{sub 0.372}Co{sub 0.372}O{sub 2} electrode powders [alternatively Li{sub 1.048}(Mn{sub 0.333}Ni{sub 0.333}Co{sub 0.333}){sub 0.952}O{sub 2} in Li{sub 1+x}M{sub 1?x}O{sub 2} notation] with extremely mild acidic solutions of NH{sub 4}PF{sub 6}, (NH{sub 4}){sub 3}AlF{sub 6}, and NH{sub 4}BF{sub 4} salts in water and methanol (pH 6-6.5) leads to remarkable cycling stability of both lithium half-cells and full lithium-ion cells when repeatedly charged to high voltages ({ge} 4.5 V). The enhanced electrochemical performance is attributed to stabilized electrode surfaces that are etched and passivated by fluorinated species. The low-temperature behavior of unconditioned and preconditioned electrodes is presented.

10 SYNTHETIC FUELS↗

Letter Report for Characterization of Biochar

On 27 November 2012, a bulk biochar sample was received for characterization of selected physical and chemical properties. The main purpose of the characterization was to help determine the degree to which biochar would be suitable as a soil amendment to aid in growth of plants. Towards this end, analyses to determine specific surface, pH, cation-exchange capacity, water retention, and wettability (i.e. surface tension) were conducted. A second objective was to determine how uniform these properties were in the sample. Towards this end, the sample was separated into fractions based on initial particle size and on whether the material was from the external surface or the internal portion of the particle. Based on the results, the biochar has significant liming potentials, significant cation-retention capacities, and highly variable plant-available moisture retention properties that, under the most favorable circumstances, could be helpful to plants. As a consequence, it would be quite suitable for addition to acidic soils and should enhance the fertility of those soils.

biochar↗

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

Two-Stage, Integrated, Geothermal-CO2 Storage Reservoirs: An Approach for Sustainable Energy Production, CO 2 -Sequestration Security, and Reduced Environmental Risk

We introduce a hybrid two-stage energy-recovery approach to sequester CO 2 and produce geothermal energy at low environmental risk and low cost by integrating geothermal production with CO 2 capture and sequestration (CCS) in saline, sedimentary formations. Our approach combines the benefits of the approach proposed by Buscheck et al. (2011b), which uses brine as the working fluid, with those of the approach first suggested by Brown (2000) and analyzed by Pruess (2006), using CO 2 as the working fluid, and then extended to saline-formation CCS by Randolph and Saar (2011a). During stage one of our hybrid approach, formation brine, which is extracted to provide pressure relief for CO 2 injection, is the working fluid for energy recovery. Produced brine is applied to a consumptive beneficial use: feedstock for fresh water production through desalination, saline cooling water, or make-up water to be injected into a neighboring reservoir operation, such as in Enhanced Geothermal Systems (EGS), where there is often a shortage of a working fluid. For stage one, it is important to find economically feasible disposition options to reduce the volume of brine requiring reinjection in the integrated geothermal-CCS reservoir (Buscheck et al. 2012a). During stage two, which begins as CO 2 reaches the production wells; coproduced brine and CO 2 are the working fluids. We present preliminary reservoir engineering analyses of this approach, using a simple conceptual model of a homogeneous, permeable CO 2 storage formation/geothermal reservoir, bounded by relatively impermeable sealing units. We assess both the CO 2 sequestration capacity and geothermal energy production potential as a function of well spacing between CO 2 injectors and brine/CO 2 producers for various well patterns and for a range of subsurface conditions.

02 PETROLEUM↗

Making Coal Relevant for Small Scale Applications: Modular Gasification for Syngas/Engine CHP Applications in Challenging Environments

This Front-End Engineering Design (FEED) study is funded by the US Department of Energy (DOE), and managed by the National Energy Technology Laboratory (NETL) through a Cooperative Agreement awarded to the University of Alaska Fairbanks (UAF) to perform a technical and cost study for the design and installation of a Hamilton-Maurer International (HMI) gasifier for generating a clean syngas for firing in reciprocating engines. An existing diesel engine generator (DEG) and a commercially available spark ignition engine are used to generate electricity with the low-Btu syngas. Other than the HMI gasifier, only commercially available technologies were assumed for this study. An important objective of this design study was to estimate capital and operating costs of small modular coal and coal/biomass fired generating units to provide wind regulation services. Although this study is based on retrofitting an existing coal fired power plant with the HMI gasifier, sufficient data was developed to characterize greenfield units. The original concept was to provide clean syngas and tars/oils from the gasification process to the existing Colt-Pielstick PC2.6B diesel engine generator (9.6 MWe) installed at the UAF Atkinson Power Plant. The intent was to convert the diesel engine to operate in a dual fuel mode, firing both syngas and tars/oils. As the project progressed, Fairbanks Morse Engine (FME), current licensee for the Colt-Pielstick engine line, was not able to develop a modification package for the engine to allow for syngas firing. Although this type of modification is available for firing natural gas, the capability does not extend to syngas. Western Energy Systems, distributor for Innio Jenbacher, was able to offer the Jenbacher Model JMS620 engine. After review of available options, the project team selected a design configuration using two Jenbacher engines rated at 1965 kWe each to fire the syngas, with the oils/tars directed to the Colt Pielstick diesel to be blended with ultra-low sulfur diesel oil (ULSD). The Jenbacher engines are expected to operate at continuous base load, with some load-following ability, while the existing diesel engine will operate in grid support service, with loads varying from a nominal 25% to 100%. An annual capacity factor for the diesel engine is projected to be between 50% and 60%. The overall gasifier and gas clean-up system is sized to produce enough syngas to adequately fuel three Jenbacher Engines for a nominal power output of 5.9 MWe, but this study assumes that only two Jenbacher engines will be installed due to space constraints in the Atkinson Power Plant, and because of expected air emission permit limitations. There is still potential that the excess syngas capacity equivalent to about 2 MWe could be used as supplemental fuel for the DEG. The exhaust from the Jenbacher engines is passed through heat recovery units to generate low pressure steam, thereby providing a significant portion of the steam required for operating the gasifier. The overall performance of the HMI gasifier/engine configuration is summarized as follows: 1) Overall electric efficiency, Jenbacher and diesel engines, based on gasifier fuel production (syngas and pyrolysis liquids) is 35.2% LHV, 2) Overall cogenerating efficiency (electricity plus steam), based on gasifier fuel production (syngas and pyrolysis liquids) is 54.8% LHV, 3) Overall electric efficiency, Jenbacher and diesel engines, based on coal input, is 29.6% LHV, and 4) Overall cogenerating efficiency, electricity plus steam, based on coal input is 46.0%. This project is estimated to have a Bare Erected Cost (BEC) of $\$$ 33.4 million and a Total Plant Cost (TPC) of $\$$ 45.7 million. Based on the original scope, sending both the clean syngas and the oils and tars to the existing diesel engine, the BEC and TPC values would have been $\$$ 23.3 million and $\$$ 32.1 million, respectively. A variable Cost of Electricity (COE) is calculated to reflect only those costs that will be incurred by incremental operation of the system for the HMI gasifier/Jenbacher engine combination. Operation of the diesel engine is determined separately. The variable COE values are: Case 1: 100% Usibelli Coal: (a) HMI gasifier/Jenbacher Engines -- 8.3 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh, and Case 2: 80% Usibelli Coal + 20% wood chips (proportion based on Btu input, LHV basis): (a) HMI Gasifier/Jenbacher -- 13.7 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh. The incremental cost of operating the gasifier/Jenbacher system increases with co-firing of wood chips due to the high cost of this material, over five times as costly as Usibelli coal delivered to the Atkinson Power building. The diesel cost is constant as the oils and tars are priced at the same value as the ULSD for the purposes of fueling the diesel engine. Section 8 of this report provides details of the O&M costs. The overall power system is configured to be modular and scalable to provide a wide range of generating capacity using the same components. This allows for reduction in cost, risk, schedule time to engineer and construct, and provides some degree of repeatability for air permitting.

01 COAL, LIGNITE, AND PEAT↗

The Role of Catholyte Modulation in Suppressing the Initial Capacity Fade of Zinc Electrolytic Manganese Dioxide Coin Cells

Despite its potential for zinc–manganese oxide batteries, electrolytic manganese dioxide (EMD) can experience capacity fade due to a deficiency in the Mn 2+ supply at the cathode electrolyte interphase (CEI) from side reactions, even in the presence of an electrolyte additive. In this work, electrolyte loading modulation at the cathode electrolyte interface (CEI) was correlated with Zn∥EMD cell capacity retention and cycling performance, as a proposed measure to curb the initial capacity fade observed in EMD. Initial galvanostatic charge/discharge cycling, with varied electrolyte loading, revealed severe capacity fade (from ~188 to 10 mAh g –1 for the highest loading of 200 μL) within the first 15 cycles. Such a decrease in cell capacity is correlated with the formation of a Mn 4+ deposit on the current collector and consequently, the Mn 2+ depletion at CEI, as was supported by elemental and Raman analyses. Interestingly, confinement of the electrolyte to the CEI at a lower (≤15 μL) electrolyte loading mitigated Mn 4+ side-deposition, maintaining the cell capacity at >80% over the first 15 cycles. Interfacial Mn supply/depletion could be monitored via voltammetric analysis based on changes of the Zn 2+ insertionreduction peak. Additional galvanostatic experiments corroborated the voltammetric interpretation and the proposed degradation pathway in the studied cell conditions. The outcomes of this work provide practical insight into coin-cell design and configuration strategies for developing Zn∥EMD batteries.

25 ENERGY STORAGE↗

An Assessment of Technical Hydropower Potential at Non-Powered Dams in the United States

Historically, dams have been constructed for a variety of purposes, such as providing a more secure and reliable water supply, mitigating impacts from variations in river flow, allowing continuous navigability, and harnessing mechanical power. A relatively small portion of dams have been designed to store or regulate flows for the purpose of generating electricity (roughly 3% of nationally inventoried dams in the US and 17% of the dams included in the World Register of Dams). The remaining population of existing non-powered dams (NPDs) presents both an opportunity to generate renewable energy and a need to modernize aging infrastructure. This report describes an assessment of more than 2,600 NPDs in the US that have a collective potential of nearly 4 GW in new power capacity. Previous national-scale assessments were aimed at evaluating the theoretical maximum power potential at existing dams in the United States. These estimates were based on the best available information at the time for water availability, hydraulic head, and representative regional capacity factors. This study revisits a subset of 3,299 dams identified in the most recent theoretical resource assessment and uses more detailed and updated hydrologic data to produce estimates of technical potential. These improvements in data enable estimates that more realistically reflect what is physically possible given simple assumptions about the existing structure and constraints on flow and head (Figure 1).

13 HYDRO ENERGY↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗