Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience

AIMTo report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT).Materials and MethodsFour consecutive female patients (mean age 38.0 years; range 25–55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.ResultsEight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40–70 min) and 53418 mGy.cm{sup 2} (range 6113–101628 mGy.cm{sup 2}), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1–12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.ConclusionsMVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Amplatzer Vascular Plug with Preoperative Common Hepatic Artery Embolization for Distal Pancreatectomy with En Bloc Celiac Axis Resection

PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the origin of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Amplatzer Vascular Plug for Preoperative Embolization Before Distal Pancreatectomy with En Bloc Celiac Axis Resection

Purpose: We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). Materials and Methods: Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative embolization of the common hepatic and the left gastric artery (CHA, LGA) with AVP or coils. We compared the embolization success rate, embolization-related complications, the time required for preoperative embolization before DP-CAR and the procedure costs in patients whose CHA was AVP- (n = 7) or coil (n = 12) embolized. Results: The success rate for preoperative AVP and coil embolization was 100% and 83.3%, respectively. The median procedure time was shorter in patients whose CHA was embolized with AVP than coils; the difference was not significant (p = 0.045). The total cost was significantly lower for AVP than coil embolization (p = 0.01). Conclusion: The AVP is useful for the preoperative embolization of the CHA before DP-CAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous measurement of x-ray absorption spectra and kinetics : a fixed-bed, plug-flow operando reactor.

An inexpensive fixed-bed, plug-flow operando reactor is described in which X-ray absorbance and kinetic data can be measured simultaneously. Pt L3 (11.56 keV) XANES and EXAFS data were obtained on a 1.5% Pt/silica catalyst in borosilicate glass reactors of different diameters, 3-6 mm, and thicknesses, 0.3-1.2 mm, some of which are capable of operation at pressures up to about 40 atm. Additionally, polyimide tubular reactors with low absorbance can be used for lower energy edges of the 3d transition metals, or fluorescence detection for low concentration or highly absorbing supports. With the polyimide reactor, however, the pressure is limited to {approx}3.5 atm and the reaction temperature to about 300 C. To validate the reactor, the rate and activation energies for the water-gas shift reaction on 2% Pd, 13.7% Zn on Al2O3 catalyst were within 15% of those obtained in a standard laboratory reactor, which is within laboratory reproducibility. In addition, the Pd K edge (24.35 keV) XANES and EXAFS data on pre-reduced catalyst were identical to that previously determined on a regular cell. The EXAFS data show that the degree of Pd-Zn alloy formation changes with reaction temperature demonstrating the importance of characterizing the catalyst under reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization-based plug-and-play measurement-device-independent quantum key distribution

Measurement-device-independent quantum key distribution (MDI-QKD) has received much attention, with the goal of overcoming all of the security loopholes caused by an imperfect detection system. We here propose a plug-and-play MDI-QKD (P&P MDI-QKD) scheme whereby an untrusted relay node, Charlie, owns a laser and sends photons to Alice and Bob. Alice (Bob) modulates the polarization of the incident photons and returns them to Charlie. Charlie uses a modified Bell state analyzer (BSA) to perform Bell state measurements (BSM). In comparison with the original version of MDI-QKD, our scheme exploits a single untrusted laser as the photon source. This makes the signal photons identical and enhances the Hong-Ou-Mandel effect. Second, because of the P&P structure, the setup can automatically eliminate the birefringence influence of the fibers, which makes the setup highly stable. Finally, our modified BSA can identify |Φ〉{sup +} and |Φ〉{sup −} of four Bell states with polarization encoding but not |Ψ〉{sup +} and |Ψ〉{sup −}. Based on practical experimental parameters, a simulation showed that the maximum theoretical secure transmission distance could reach more 280 km.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comprehensive powertrain modeling for heavy-duty applications: A study of plug-in hybrid electric bus

A comprehensive forward-looking powertrain model with an efficiency-based control strategy was developed to achieve real-time optimization of plug-in hybrid electric buses while considering the real vehicle drivability and the practical operation of all powertrain components under real driving conditions. The control strategy is based on a supervisory control algorithm that alternately employs charge-dominant control and discharge-dominant control to manage multiple powertrain sources, and enable an optimal overall efficiency-based powertrain operation state by maximizing the inherent optimal powertrain efficiency through best all transmission gear choice and the blend of motor and/or engine power. In the model, a component energy efficiency database was developed to rapidly enable an smart and optimal operating state determined from a set of efficiency maps characterizing the component and powertrain control states as a function of the instantaneous vehicle operational condition. The results revealed that the energy savings achieved with the innovative powertrain control improved by 10%–30% compared with the baseline hybrid powertrain control strategy. The benefits of eco-driving with respect to energy consumption were also evaluated using the powertrain model. The powertrain control model was implemented into a real hybrid bus. Measured energy savings with the optimized control strategy were similar to the simulated results.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of plug-in hybrid electric vehicles on power systems with demand response and wind power.

This paper uses a new unit commitment model which can simulate the interactions among plug-in hybrid electric vehicles (PHEVs), wind power, and demand response (DR). Four PHEV charging scenarios are simulated for the Illinois power system: (1) unconstrained charging, (2) 3-hour delayed constrained charging, (3) smart charging, and (4) smart charging with DR. The PHEV charging is assumed to be optimally controlled by the system operator in the latter two scenarios, along with load shifting and shaving enabled by DR programs. The simulation results show that optimally dispatching the PHEV charging load can significantly reduce the total operating cost of the system. With DR programs in place, the operating cost can be further reduced.

17 WIND ENERGY↗

Cost Analysis of Plug-In Hybred Electric Vehicles Using GPS-Based Longitudinal Travel Data

Using spatial, longitudinal travel data of 415 vehicles over 3 18 months in the Seattle metropolitan area, this paper estimates the operating costs of plug-in hybrid electric vehicles (PHEVs) of various electric ranges (10, 20, 30, and 40 miles) for 3, 5, and 10 years of payback period, considering different charging infrastructure deployment levels and gasoline prices. Some key findings were made. (1) PHEVs could help save around 60% or 40% in energy costs, compared with conventional gasoline vehicles (CGVs) or hybrid electric vehicles (HEVs), respectively. However, for motorists whose daily vehicle miles traveled (DVMT) is significant, HEVs may be even a better choice than PHEV40s, particularly in areas that lack a public charging infrastructure. (2) The incremental battery cost of large-battery PHEVs is difficult to justify based on the incremental savings of PHEVs operating costs unless a subsidy is offered for largebattery PHEVs. (3) When the price of gasoline increases from $4/gallon to $5/gallon, the number of drivers who benefit from a larger battery increases significantly. (4) Although quick chargers can reduce charging time, they contribute little to energy cost savings for PHEVs, as opposed to Level-II chargers.

Wu, Xing↗

Data mining of plug-in electric vehicles charging behavior using supply-side data

This paper aims to better understand the charging patterns of plug-in electric vehicles (PEVs) and identify factors that may significantly impact PEVs’ charging behavior. We collected 189,864 supply-side charging session data over 13 months from 821 charging stations in Illinois from ChargePoint. Through descriptive and regression analyses, we characterize the distributions of key charging behavior indicators, including charging location, dwell time, and battery start state of charge (SOC), and quantify the impacts of closely related factors on these charging behaviors. In this work, we find that: (1) PEVs are more likely to charge in the morning at multifamily commercial locations with a lower start SOC compared with single family residential locations; (2) Weekday and morning sessions are more likely to utilize workplace charging and have shorter dwell time compared with weekend and afternoon sessions; (3) Single family residential area and locations with Levels 1/2 chargers have a higher start SOC and longer dwell time compared with other locations and DC fast chargers (DCFCs). These findings provide policy insights to identify potential time and locations to incentivize PEVs for grid services, as well as identify critical location categories for further charging infrastructure investment to better reduce range anxiety and promote PEV adoption.

33 ADVANCED PROPULSION SYSTEMS↗

Perspective on the oil-dominated gas hydrate plugging conceptual picture as applied to transient Shut-In/Restart

Gas hydrate formation is rarely an issue during continuous production conditions. Unplanned and/or extended shut-downs comprise the majority of scenarios where overlapping concern and uncertainty for gas hydrate blockages exist. To date, most experimental studies and theoretical analysis of gas hydrate formation derive from the steady-state conceptual picture. Yet, significant distinctions induced by phase separation and prolonged cooling suggest an altered conceptual picture is required for transient shut-in/restart operations. To address this outstanding issue, this work presents a conceptual picture for the base case of a non-surface active hydrocarbon undergoing cold restart without enacted mitigation efforts. First, phase separation upon shut-in leads to the localization of gas hydrate ingredients due to fluids density differences and pipeline inclination. Cooling to the seafloor temperature, then, induces gas hydrate film formation at the hydrocarbon interface and maximizes subcooling, resulting in rapid and confined gas hydrate growth occurring upon restart. Furthermore, this ultimately leads to plugging dominated by the deposition of porous, low conversion gas hydrate masses. Direct visual observations and results from Raman spectroscopy, hydrate contact angle and film growth, micromechanical force apparatus, rocking cell, and flow loop studies support the mechanisms outlined within each step. Similar to the influence provided by the original Colorado School of Mines steady-state conceptual picture that was introduced about 15 years ago, this transient counterpart builds a foundation that could inspire new directions of hydrate research and analysis in areas where uncertainty abounds.

02 PETROLEUM↗

Evaluation of commercial lithium-ion cells based on composite positive electrode for plug-in hybrid electric vehicle applications. Part I: Initial characterizations

Evaluating commercial Li-ion batteries presents some unique benefits. One of them is to use cells made from established fabrication process and form factor, such as those offered by the 18650 cylindrical configuration, to provide a common platform to investigate and understand performance deficiency and aging mechanism of target chemistry. Such an approach shall afford us to derive relevant information without influence from processing or form factor variability that may skew our understanding on cell-level issues. A series of 1.9 Ah 18650 lithium ion cells developed by a commercial source using a composite positive electrode comprising (LiMn1/3Ni1/3Co1/3O2 + LiMn2O4) is being used as a platform for the investigation of certain key issues, particularly path-dependent aging and degradation in future plug-in hybrid electric vehicle (PHEV) applications, under the US Department of Energy's Applied Battery Research (ABR) program. Here we report in Part I the initial characterizations of the cell performance and Part II some aspects of cell degradation in 2C cycle aging. The initial characterizations, including cell-to-cell variability, are essential for life cycle performance characterization in the second part of the report when cell-aging phenomena are discussed. Due to the composite nature of the positive electrode, the features (or signature) derived from the incremental capacity (IC) of the cell appear rather complex. In this work, the method to index the observed IC peaks is discussed. Being able to index the IC signature in details is critical for analyzing and identifying degradation mechanism later in the cycle aging study.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a plug-and-play anti-noise module for fault diagnosis of rotating machines in nuclear power plants

The health of rotating machines is crucial to the stable operation and safety of nuclear power plants. However, research on machine learning-based fault diagnosis of rotating machines in the nuclear industry is still in its infancy. The signal noise generated in the plant may negatively affect the effectiveness of the analysis. In this paper, a plug-and-play anti-noise machine learning module is proposed to fill the knowledge and capability gap. The modules are loaded into a convolutional neural network called deep residual network (ResNet) to obtain a new model with noise reduction capability. The basic idea is that the module is able to identify noise features and include them in the subsequent analysis, effectively filtering noise at the feature level of the network. Nine variants of the new model are compared with the original ResNet as well as four classical machine learning models to test the effectiveness of the module and to examine the impact of the module's loading modes on the performance of the new model. Finally, this research helps facilitate the application of machine learning in the plant noise environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimation of vehicle home parking availability in China and quantification of its potential impacts on plug-in electric vehicle ownership cost

China has become the world's largest plug-in electric vehicle (PEV) market. One major barrier to greater consumer acceptance of PEVs is the lack of home parking spaces for charging outlets. This paper developed a methodology to estimate the residential parking ratios (parking spaces vs household numbers) and project the residential community-weighted parking availabilities (home parking availabilities) in China, by area and by province, through data mining from several major real estate trading network platforms. The results show that the home parking availabilities from 2015 to 2050 vary by geographic areas and building life expectancy. A method was developed to quantify the shadow values of home parking impacting on PEV ownership costs and combined with Monte Carlo simulation to address estimation uncertainty. Depending on the PEV type and all-electric range, the value of home parking space to a PEV owner, measured by the reduced vehicle ownership cost, ranges from $2399 USD to 10,802 USD. Finally, the total incremental shadow value, relative to the 2015 situation, of the home parking availability for PEV owners increases over time due to both improvement in home parking availability and increase in the PEV population, and is estimated to reach over 2.51 billion USD by 2025 (U.S. dollars in 2015 level).

33 ADVANCED PROPULSION SYSTEMS↗

Well-to-Wheels Analysis of Zero-Emission Plug-In Battery Electric Vehicle Technology for Medium- and Heavy-Duty Trucks

Conventional diesel medium- and heavy-duty vehicles (MHDVs) create large amount of air emissions. With the advancement in technology and reduction in the cost of batteries, plug-in battery electric vehicles (BEVs) are increasingly attractive options for improving energy efficiency and reducing air emissions of MHDVs. In this paper, we compared the well-to-wheels (WTW) greenhouse gases (GHGs) and criteria air pollutant emissions of MHD BEVs with their conventional diesel counterparts across weight classes and vocations. We expanded the Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET) model to conduct the WTW analysis of MHDVs. The fuel economy for a wide range of MHDV weight classes and vocations, over various driving cycles, was evaluated using a high-fidelity vehicle dynamic simulation software (Autonomie). The environmental impacts of MHD BEVs are sensitive to the source of electricity used to recharge their batteries. The WTW results show that MHD BEVs significantly improve environmental sustainability of MHDVs by providing deep reductions in WTW GHGs, nitrogen oxides, volatile organic compounds, and carbon monoxide emissions, compared to conventional diesel counterparts. Increasing shares of renewable and natural gas technologies in future national and regional electricity generation are expected to reduce WTW particulate matters and sulfur oxide emissions for further improvement of the environmental performance of MHD BEVs.

33 ADVANCED PROPULSION SYSTEMS↗

Room temperature continuous wave operation of quantum cascade lasers with 12.5% wall plug efficiency

An InP based quantum cascade laser heterostructure emitting at 4.6 {mu}m was grown with gas-source molecular beam epitaxy. The wafer was processed into a conventional double-channel ridge waveguide geometry with ridge widths of 19.7 and 10.6 {mu}m without semi-insulating InP regrowth. An uncoated, narrow ridge device with a 4.8 mm cavity length was epilayer down bonded to a diamond submount and exhibits 2.5 W maximum output power with a wall plug efficiency of 12.5% at room temperature in continuous wave operation.

36 MATERIALS SCIENCE↗