Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “physical exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A 2D finite element wave equation solver based on triangular base elements

A finite element method based on the subdivision of the physical domain in triangular sub-domains in which simple local 'areale' coordinates are adopted is explored. The advantage of the method is that it straightforwardly allows grid refinement in regions where higher precision is required. The plasma model was kept simple for this 'proof-of-principle' exercise. Rather than accounting for the actual differential or integro-differential dielectric tensor, its locally uniform plasma equivalent was adopted for 3 possible choices: the cold plasma response, the full hot Stix/Swanson plasma tensor retaining all orders in finite Larmor radius (FLR) and the more common hot tensor, truncated at terms of second order in the Larmor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical signaling in the development of postmenopausal osteoporosis

Estrogen deficiency results in increased bone turnover and net bone loss in rats as well as humans. The respective roles of bone turnover and mechanical strain in mediating estrogen deficiency-induced cancellous bone loss were investigated in ovariectomized rats. Ovariectomy resulted in increased bone turnover in long bones. However, cancellous bone was preferentially lost in the metaphysis, a site that experiences low strain energy during normal physical activity. No bone loss was observed in the epiphysis, a site experiencing higher strain energy, despite a similar increase in bone turnover. The role of mechanical strain in maintaining bone balance was investigated by altering the strain history. Mechanical strain was increased or decreased in long bones of ovariectomized rats by treadmill exercise or functional unloading, respectively. Increasing mechanical loading reduced bone loss in the metaphysis. In contrast, decreasing weight bearing accentuated bone loss in the metaphysis and resulted in bone loss in the epiphysis. Finally, administration of estrogen to ovariectomized rats reduced bone loss in unloaded limbs and prevented bone loss in the loaded limbs. These results suggest that estrogen alters the mechanosensory (mechanostat) set point for skeletal adaptation, effectively reducing the minimum strain energy levels at which bone is added. Additionally, these studies suggest that physical activity as well as endocrine status play an important role in maintenance of the female skeleton during aging.

Non-NASA Center↗

Development of computer-based analytical tool for assessing physical protection system

Assessment of physical protection system effectiveness is the priority for ensuring the optimum protection caused by unlawful acts against a nuclear facility, such as unauthorized removal of nuclear materials and sabotage of the facility itself. Since an assessment based on real exercise scenarios is costly and time-consuming, the computer-based analytical tool can offer the solution for approaching the likelihood threat scenario. There are several currently available tools that can be used instantly such as EASI and SAPE, however for our research purpose it is more suitable to have the tool that can be customized and enhanced further. In this work, we have developed a computer–based analytical tool by utilizing the network methodological approach for modelling the adversary paths. The inputs are multi-elements in security used for evaluate the effectiveness of the system’s detection, delay, and response. The tool has capability to analyze the most critical path and quantify the probability of effectiveness of the system as performance measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The duality between color and kinematics and its applications

Abstract This review describes the duality between color and kinematics and its applications, with the aim of gaining a deeper understanding of the perturbative structure of gauge and gravity theories. We emphasize, in particular, applications to loop-level calculations, the broad web of theories linked by the duality and the associated double-copy structure, and the issue of extending the duality and double copy beyond scattering amplitudes. The review is aimed at doctoral students and junior researchers both inside and outside the field of amplitudes and is accompanied by various exercises.

Physics↗

Plutonium Oxide Process Capability Work Plan

Pacific Northwest National Laboratory (PNNL) has been tasked to develop a Pilot-scale Plutonium-oxide Processing Unit (P3U) providing a flexible capability to produce 200g (Pu basis) samples of plutonium oxide using different chemical processes for use in identifying and validating nuclear forensics signatures associated with plutonium production. Materials produced can also be used as exercise and reference materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

cAMP levels in fast- and slow-twitch skeletal muscle after an acute bout of aerobic exercise

The present study examined whether exercise duration was associated with elevated and/or sustained elevations of postexercise adenosine 3',5'-cyclic monophosphate (cAMP) by measuring cAMP levels in skeletal muscle for up to 4 h after acute exercise bouts of durations that are known to either produce (60 min) or not produce (10 min) mitochondrial proliferation after chronic training. Treadmill-acclimatized, but untrained, rats were run at 22 m/min for 0 (control), 10, or 60 min and were killed at various postexercise (0, 0.5, 1, 2, and 4 h) time points. Fast-twitch white and red (quadriceps) and slow-twitch (soleus) muscles were quickly excised, frozen in liquid nitrogen, and assayed for cAMP with a commercial kit. Unexpectedly, cAMP contents in all three muscles were similar to control (nonexercise) at most (21 of 30) time points after a single 10- or 60-min run. Values at 9 of 30 time points were significantly different from control (P < 0.05); i.e., 3 time points were significantly higher than control and 6 were significantly less than control. These data suggest that the cAMP concentration of untrained skeletal muscle after a single bout of endurance-type exercise is not, by itself, associated with exercise duration.

NASA Discipline Musculoskeletal↗

Reduced Incidence of Cardiac Arrhythmias in Walkers and Runners

Walking is purported to reduce the risk of atrial fibrillation by 48%, whereas jogging is purported to increase its risk by 53%, suggesting a strong anti-arrhythmic benefit of walking over running. The purpose of these analyses is to compare incident self-reported physician-diagnosed cardiac arrhythmia to baseline energy expenditure (metabolic equivalent hours per day, METhr/d) from walking, running and other exercise. Proportional hazards analysis of 14,734 walkers and 32,073 runners. There were 1,060 incident cardiac arrhythmias (412 walkers, 648 runners) during 6.2 years of follow-up. The risk for incident cardiac arrhythmias declined 4.4% per baseline METhr/d walked by the walkers, or running in the runners (P = 0.0001). Specifically, the risk declined 14.2% (hazard ratio: 0.858) for 1.8 to 3.6 METhr/d, 26.5% for 3.6 to 5.4 METhr/d, and 31.7% for $5.4 METhr/d, relative to ,1.8 METhr/d. The risk reduction per METhr/d was significantly greater for walking than running (P,0.01), but only because walkers were at 34% greater risk than runners who fell below contemporary physical activity guideline recommendations; otherwise the walkers and runners had similar risks for cardiac arrhythmias. Cardiac arrhythmias were unrelated to walking and running intensity, and unrelated to marathon participation and performance. The risk for cardiac arrhythmias was similar in walkers and runners who expended comparable METhr/d during structured exercise. We found no significant risk increase for self-reported cardiac arrhythmias associated with running distance, exercise intensity, or marathon participation. Rhythm abnormalities were based on self-report, precluding definitive categorization of the nature of the rhythm disturbance. However, even if the runners’ arrhythmias include sinus bradycardia due to running itself, there was no increase in arrhythmias with greater running distance.

59 BASIC BIOLOGICAL SCIENCES↗

Project Summary 27th International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities

The course content consisted of 32 modules that included topics necessary to understand how to conduct PPS design and evaluation. An important aspect of ITC-27's training methodology was to ensure that each topic was presented via lecture (hear), and also included demonstrations (see) and hands-on field activities (do), whenever applicable. A final exercise provided participants with the opportunity to apply the design and evaluation knowledge gained during the course. Guest lecturers—both domestic and international—supplemented information from related agency perspectives. A new topic—Unmanned Aerial Systems (UAS)—offered participants a high-level awareness of the types, uses, and capabilities of these systems and how they might be used in both an adversarial and protective capacity.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainty Quantification in Climate Modeling and Projection

The projection of future climate is one of the most complex problems undertaken by the scientific community. Although scientists have been striving to better understand the physical basis of the climate system and to improve climate models, the overall uncertainty in projections of future climate has not been significantly reduced (e.g., from the IPCC AR4 to AR5). With the rapid increase of complexity in Earth system models, reducing uncertainties in climate projections becomes extremely challenging. Since uncertainties always exist in climate models, interpreting the strengths and limitations of future climate projections is key to evaluating risks, and climate change information for use in Vulnerability, Impact, and Adaptation (VIA) studies should be provided with both well-characterized and well-quantified uncertainty. The workshop reported herein aimed at providing participants, many of them from developing countries, information on strategies to quantify the uncertainty in climate model projections and assess the reliability of climate change information for decision-making. The program included a mixture of lectures on fundamental concepts in Bayesian inference and sampling, applications, and hands-on computer laboratory exercises employing software packages for Bayesian inference, Markov Chain Monte Carlo methods, and global sensitivity analyses. The lectures covered a range of scientific issues underlying the evaluation of uncertainties in climate projections, such as the effects of uncertain initial and boundary conditions, uncertain physics, and limitations of observational records. Progress in quantitatively estimating uncertainties in hydrologic, land surface, and atmospheric models at both regional and global scales was also reviewed. The application of Uncertainty Quantification (UQ) concepts to coupled climate system models is still in its infancy. The Coupled Model Intercomparison Project (CMIP) multi-model ensemble currently represents the primary data for assessing reliability and uncertainties of climate change information. An alternative approach is to generate similar ensembles by perturbing parameters within a single-model framework. One of workshop’s objectives was to give participants a deeper understanding of these approaches within a Bayesian statistical framework. However, there remain significant challenges still to be resolved before UQ can be applied in a convincing way to climate models and their projections.

54 ENVIRONMENTAL SCIENCES↗

Physiological coherence in healthy volunteers during laboratory‐induced stress and controlled breathing

Abstract Physiological coherence has been related with a general sense of well‐being and improvements in health and physical, social, and cognitive performance. The aim of this study was to evaluate the relationship between acute stress, controlled breathing, and physiological coherence, and the degree of body systems synchronization during a coherence‐generation exercise. Thirty‐four university employees were evaluated during a 20‐min test consisting of four stages of 5‐min duration each, during which basal measurements were obtained (Stage 1), acute stress was induced using validated mental stressors (Stroop test and mental arithmetic task, during Stage 2 and 3, respectively), and coherence states were generated using a controlled breathing technique (Stage 4). Physiological coherence and cardiorespiratory synchronization were assessed during each stage from heart rate variability, pulse transit time, and respiration. Coherence measurements derived from the three analyzed variables increased during controlled respiration. Moreover, signals synchronized during the controlled breathing stage, implying a cardiorespiratory synchronization was achieved by most participants. Hence, physiological coherence and cardiopulmonary synchronization, which could lead to improvements in health and better life quality, can be achieved using slow, controlled breathing exercises. Meanwhile, coherence measured during basal state and stressful situations did not show relevant differences using heart rate variability and pulse transit time. More studies are needed to evaluate the ability of coherence ratio to reflect acute stress.

Mejía‐Mejía, Elisa↗

A Magnetic Diagnostic Code for 3D Fusion Equilibria

A synthetic magnetic diagnostics code for fusion equilibria is presented. This code calculates the response of various magnetic diagnostics to the equilibria produced by the VMEC and PIES codes. This allows for treatment of equilibria with both good nested flux surfaces and those with stochastic regions. DIAGNO v2.0 builds upon previous codes through the implementation of a virtual casing principle. The codes is validated against a vacuum shot on the Large Helical Device where the vertical field was ramped. As an exercise of the code, the diagnostic response for various equilibria are calculated on the Large Helical Device (LHD).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Overview of Chain of Custody Options for LETTERPRESS.

This purpose of this document is to provide an overview of Chain of Custody (CoC) technology options that could be made available for the LETTERPRESS exercise as part of the Quad Working Group. The Quad Working Group comprises five sub-working groups (Management, Protocol, Simulation, Technology, and Training) with members from the U.S., U.K., Norway, and Sweden having the goal of providing a repeatable, realistic arms control exercise (dubbed LETTERPRESS) to be executed in representative facilities and using non-proliferative but representative treaty items. The Technology Working Group is responsible for supporting the technology requirements of the LETTERPRESS exercise and as such the technologies presented here are possible options to meet those requirements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Determining the amount of physical activity needed for long-term weight control

OBJECTIVE: To evaluate prospectively the influence of habitual physical activity on body weight of men and women and to develop a model that defines the role of physical activity on longitudinal weight change. DESIGN AND SETTING: Occupational cohort study conducted for a mean of 5.5 y. SUBJECTS: A total of 496 (341 male and 155 female) NASA/Johnson Space Center employees who completed the 3 month education component of the employee health-related fitness program and remained involved for a minimum of 2 y. MEASUREMENTS: Body weights were measured at baseline (T1) and follow-up (T2), and habitual physical activity was obtained from the mean of multiple ratings of the 11-point (0-10) NASA Activity Scale (NAS) recorded quarterly between T1 and T2. Other measures included age, gender, VO(2 max) obtained from maximal treadmill testing, body mass index (BMI), and body fat percentage. RESULTS: Multiple regression demonstrated that mean NAS, T1 weight, aging and gender all influence long-term T2 weight. T1 age was significant for the men only. Independently, each increase in mean NAS significantly (P<0.01) reduced T2 weight in men (b=-0.91 kg; 95% CI:-1.4 to-0.42 kg) and women (b=-2.14 kg; 95% CI:-2.93 to-1.35 kg). Mean NAS had a greater effect on T2 weight as T1 weight increased, and the relationship was dose-dependent. CONCLUSIONS: Habitual physical activity is a significant source of long-term weight change. The use of self-reported activity level is helpful in predicting long-term weight changes and may be used by health care professionals when counseling patients about the value of physical activity for weight control.

Exercise↗

Influence of exercise training on the oxidative capacity of rat abdominal muscles

Our purpose was to determine if endurance exercise training would increase the oxidative capacity of the abdominal expiratory muscles of the rat. Accordingly, 9 male rats were subjected to an endurance training protocol (1 h/day, 6 days/week, 9 weeks) and 9 litter-mates served as controls. Citrate synthase (CS) activity was used as an index of oxidative capacity, and was determined in the following muscles: soleus, plantaris, costal diaphragm, crural diaphragm, and in all four abdominal muscles: rectus abdominis, transversus abdominis, external oblique, and internal oblique. Compared to their non-trained litter-mates, the trained rats had higher peak whole body oxygen consumption rates (+ 16%) and CS activities in plantaris (+34%) and soleus (+36%) muscles. Thus, the training program caused substantial systemic and locomotor muscle adaptations. The CS activity of costal diaphragm was 20% greater in the trained animals, but no difference was observed in crural diaphragm. The CS activity in the abdominal muscles was less than one-half of that in locomotor and diaphragm muscles, and there were no significant changes with training except in the rectus abdominis where a 26% increase was observed. The increase in rectus abdominis CS activity may reflect its role in postural support and/or locomotion, as none of the primary expiratory pumping muscles adapted to the training protocol. The relatively low levels of CS activity in the abdominal muscles suggests that they are not recruited frequently at rest, and the lack of an increase with training indicates that these muscles do not contribute significantly to the increased ventilatory activity accompanying exercise in the rat.

Non-NASA Center↗

A New, More Physically Based Algorithm, for Retrieving Aerosol Properties over Land from MODIS

The MOD Imaging Spectrometer (MODIS) has been successfully retrieving aerosol properties, beginning in early 2000 from Terra and from mid 2002 from Aqua. Over land, the retrieval algorithm makes use of three MODIS channels, in the blue, red and infrared wavelengths. As part of the validation exercises, retrieved spectral aerosol optical thickness (AOT) has been compared via scatterplots against spectral AOT measured by the global Aerosol Robotic NETwork (AERONET). On one hand, global and long term validation looks promising, with two-thirds (average plus and minus one standard deviation) of all points falling between published expected error bars. On the other hand, regression of these points shows a positive y-offset and a slope less than 1.0. For individual regions, such as along the U.S. East Coast, the offset and slope are even worse. Here, we introduce an overhaul of the algorithm for retrieving aerosol properties over land. Some well-known weaknesses in the current aerosol retrieval from MODIS include: a) rigid assumptions about the underlying surface reflectance, b) limited aerosol models to choose from, c) simplified (scalar) radiative transfer (RT) calculations used to simulate satellite observations, and d) assumption that aerosol is transparent in the infrared channel. The new algorithm attempts to address all four problems: a) The new algorithm will include surface type information, instead of fixed ratios of the reflectance in the visible channels to the mid-IR reflectance. b) It will include updated aerosol optical properties to reflect the growing aerosol retrieved from eight-plus years of AERONE". operation. c) The effects of polarization will be including using vector RT calculations. d) Most importantly, the new algorithm does not assume that aerosol is transparent in the infrared channel. It will be an inversion of reflectance observed in the three channels (blue, red, and infrared), rather than iterative single channel retrievals. Thus, this new formulation of the MODIS aerosol retrieval over land includes more physically based surface, aerosol and radiative transfer with fewer potentially erroneous assumptions.

Levy, Robert C.↗

Changes in Body Inertia During Bed Rest Studies

Development of effective exercise countermeasures is crucial for long duration human space flight. To analyze the mechanical effects of a particular exercise on the musculoskeletal system, the inertial properties of segments of the body must be quantified. Since bone mineral density loss is related to the lack of mechanical stress and strain on the skeletal system, physical analysis can be very useful for countermeasure evaluation.

Todd, Beth A.↗

Setting a VO2 Max Standard for NASA Astronauts During Spaceflight

Aerobic fitness is best measured by Maximal Aerobic Capacity or VO2 Max which is defined as a measure of oxygen utilization and transport. Increased Vo2 max indicates improved oxygen consumption during high level exercise and is widely accepted as a predictor of an individual's likelihood of successfully completing a demanding task. As such, agencies and organizations have adopted VO2 max as part of a comprehensive set of physical requirements. The purpose of this study is to review the literature and existing medical and occupational VO2 max data, to propose a VO2 max standard for NASA astronauts for training and spaceflight.

Shahi, Varun↗

A Magnetic Diagnostic Code for 3D Fusion Equilibria

A synthetic magnetic diagnostics code for fusion equilibria is presented. This code calculates the response of various magnetic diagnostics to the equilibria produced by the VMEC and PIES codes. This allows for treatment of equilibria with both good nested flux surfaces and those with stochastic regions. DIAGNO v2.0 builds upon previous codes through the implementation of a virtual casing principle. The code is validated against a vacuum shot on the Large Helical Device (LHD) where the vertical field was ramped. As an exercise of the code, the diagnostic response for various equilibria are calculated on the LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗