Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Measured Indoor Nitrogen Oxides in Homes with a Child with Asthma and Gas or Induction Electric Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study is a randomized control trial investigating the effects of replacing gas with induction electric ranges in the homes of children with asthma in California's San Joaquin Valley. Indoor air quality parameters and respiratory health indicators were measured over 2-week intensive at Baseline and after consecutive 3-month study phases, with half getting electric cooking at the start of Phase 1 and others in Phase 2. Indoor air measurements included time-integrated NO 2 and NO X by passive sampler and time-resolved NO 2 by electrochemical sensors. In the first 40 homes, data were collected during 61 intensives for gas cooking and 55 for induction. Cooking was identified using temperature sensors above the cooktop. Pollutant events were identified from sharp rises in concentrations Time integrated NOX species were lower with electric cooking, with mean differences of 14.2 ppb for NO 2 (95% CI: 9.6, 18.7; p < 0.001), 55.6 ppb for NO X (95% CI: 30.4, 80.9; p < 0.001), and 41.5 ppb for derived NO (95% CI: 19.7, 63.2; p < 0.001). A paired, within home analysis showed larger reductions in Group 2 (gas to induction) than Group 1 that remained electric across Phase 1 and Phase 2 for NO 2 (mean difference in As of 10.5 ppb; 95% CI: 5.6, 15.4; p < 0.001), NO X (32.3 ppb; 95% CI: 10.0, 54.5; p=0.007), and derived NO (21.8 ppb; 95% CI: 3.6, 40.0; p=0.022). Compared to electric cooking, gas had much higher rates of associated NO 2 events, and larger above-baseline NO 2 peaks. These preliminary results are consistent with prior findings that shifting to induction cooking can substantially lower indoor NO 2 compared with gas cooking.

Fang, Yi↗

A Natural ≳100× Telescope: Discovery of the Strongly Lensed Type II SN 2025mkn at z = 1.37

We present the discovery of SN 2025mkn, a gravitationally lensed Type II supernova. First detected as a blue transient in Zwicky Transient Facility (ZTF), 0. "83 from a z = 0.42 elliptical galaxy, the follow-up SNIFS/UH2.2 m and LRIS/Keck spectra revealed absorption lines at z = 1.371. Later JWST NIRCam imaging shows that the bright transient is a close pair of point sources separated by 0. "07, and a 30 times fainter counterimage opposite the lens, for which NIRSpec reveals strong Hα emission also at z = 1.371. The lightcurves and spectra are consistent with the Type II supernova source being magnified ≳100 times, with ∼250 required to reconcile its luminosity with that of nearby events such as SN 2023ixf. Lens models are consistent with such high magnifications, and always show that the faint image arrived first (undetected in earlier ZTF imaging), consistent with the later spectral phase of this fainter image. A fourth image is also predicted and possibly detected in the NIRSpec data. Lightcurve-based time-delay measurements are not possible due to the first image being the faintest; however, the resolved NIRSpec spectra offer a future opportunity for time-delay cosmography through supernova phase measurements.

Strong gravitational lensing↗

Heisenberg-limited Hamiltonian learning for interacting bosons

We develop a protocol for learning a class of interacting bosonic Hamiltonians from dynamics with Heisenberg-limited scaling. For Hamiltonians with an underlying bounded-degree graph structure, we can learn all parameters with root mean square error ϵ using ${\mathcal{O}}(1/\epsilon )$ total evolution time, which is independent of the system size, in a way that is robust against state-preparation and measurement error. In the protocol, we only use bosonic coherent states, beam splitters, phase shifters, and homodyne measurements, which are easy to implement on many experimental platforms. A key technique we develop is to apply random unitaries to enforce symmetry in the effective Hamiltonian, which may be of independent interest.

computer science↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Integrated quantum optical phase sensor in thin film lithium niobate

Abstract The quantum noise of light, attributed to the random arrival time of photons from a coherent light source, fundamentally limits optical phase sensors. An engineered source of squeezed states suppresses this noise and allows phase detection sensitivity beyond the quantum noise limit (QNL). We need ways to use quantum light within deployable quantum sensors. Here we present a photonic integrated circuit in thin-film lithium niobate that meets these requirements. We use the second-order nonlinearity to produce a squeezed state at the same frequency as the pump light and realize circuit control and sensing with electro-optics. Using 26.2 milliwatts of optical power, we measure (2.7 ± 0.2)% squeezing and apply it to increase the signal-to-noise ratio of phase measurement. We anticipate that photonic systems like this, which operate with low power and integrate all of the needed functionality on a single die, will open new opportunities for quantum optical sensing.

47 OTHER INSTRUMENTATION↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESS Observations of the WASP-121 b Phase Curve

We study the red-optical photometry of the ultrahot Jupiter WASP-121 b as observed by the Transiting Exoplanet Survey Satellite (TESS) and model its atmosphere through a radiative transfer simulation. Given its short orbital period of ∼1.275 days, inflated state, and bright host star, WASP-121 b is exceptionally favorable for detailed atmospheric characterization. Toward this purpose, we use allesfitter to characterize its full red-optical phase curve, including the planetary phase modulation and secondary eclipse. We measure the day- and nightside brightness temperatures in the TESS passband as 3012{sub −42}{sup +40} and 2022{sub −602}{sup +254} K, respectively, and do not find a statistically significant phase shift between the brightest and substellar points. This is consistent with inefficient heat recirculation on the planet. We then perform an atmospheric retrieval analysis to infer the dayside atmospheric properties of WASP-121 b, such as its bulk composition, albedo, and heat recirculation. We confirm the temperature inversion in the atmosphere and suggest H{sup −}, TiO, and VO as potential causes of the inversion, absorbing heat at optical wavelengths at low pressures. Future Hubble Space Telescope and James Webb Space Telescope observations of WASP-121 b will benefit from its first full phase curve measured by TESS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of window temperature variations on ITER toroidal interferometer and polarimeter (TIP) measurements

Abstract The toroidal interferometer and polarimeter (TIP) is one of the primary electron density diagnostics on ITER. To meet measurement requirements over several thousand seconds, environmental factors such as changes in the window temperature, air temperature, and humidity, which can cause uncompensated phase drifts, must be minimized. This paper reports measurements of the phase shift induced by ZnSe and BaF₂ windows as their temperature is varied utilizing the TIP prototype. To accomplish these measurements, test pieces of BaF₂ and ZnSe are placed in a small oven that is located in one leg of the 10.59/5.22 micron two-color interferometer TIP prototype. The oven temperature was varied from room temperature to ∼90 °C, which is slightly higher than the expected window temperatures on ITER. The vibration compensated phase shifts measured for these two materials are dϕᵥ꜀ /dT/L = 0.0121 and −0.275 deg. /°C/cm −1 for BaF₂ and ZnSe, respectively. From these measurements, it was concluded that temperature variations of the environmental/secondary confinement barrier window and primary vacuum window have to be suppressed within approximately 1°C and 2°C, respectively, in order to passively meet the electron density measurement requirements in ITER.

Akiyama, T (ORCID:0000000198469795)↗

Differential $t\overline{t}$ cross-section measurements using boosted top quarks in the all-hadronic final state with 139 fb -1 of ATLAS data

Measurements of single-, double-, and triple-differential cross-sections are presented for boosted top-quark pair-production in 13 TeV proton–proton collisions recorded by the ATLAS detector at the LHC. The top quarks are observed through their hadronic decay and reconstructed as large-radius jets with the leading jet having transverse momentum (pT) greater than 500 GeV. The observed data are unfolded to remove detector effects. The particle-level cross-section, multiplied by the $t\overline{t}$ $\rightarrow$ $WWb$$\overline{b}$ branching fraction and measured in a fiducial phase space defined by requiring the leading and second-leading jets to have p T > 500 GeV and p T > 350 GeV, respectively, is 331 ± 3(stat.) ± 39(syst.) fb. This is approximately 20% lower than the prediction of ${398}^{+48}_{-49}$ fb by POWHEG+PYTHIA 8 with next-to-leading-order (NLO) accuracy but consistent within the theoretical uncertainties. Results are also presented at the parton level, where the effects of top-quark decay, parton showering, and hadronization are removed such that they can be compared with fixed-order next-to-next-to-leading-order (NNLO) calculations. The parton-level cross-section, measured in a fiducial phase space similar to that at particle level, is 1.94 ± 0.02(stat.) ± 0.25(syst.) pb. This agrees with the NNLO prediction of ${1.96}^{+0.02}_{-0.17}$ pb. Reasonable agreement with the differential cross-sections is found for most NLO models, while the NNLO calculations are generally in better agreement with the data. The differential cross-sections are interpreted using a Standard Model effective field-theory formalism and limits are set on Wilson coefficients of several four-fermion operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production and Chemical Analysis of NaCl-KCl-UCl 3 Salts

Thermochemical and thermophysical properties of several molten salt systems of interest to molten salt reactor (MSR) developers are being measured at Argonne National Laboratory. These properties are needed by developers to design, license, and operate their reactors. Thermochemical properties being measured at Argonne include thermal transitions, phase behavior, and heat capacity. Thermophysical properties being measured at Argonne include liquid density, surface tension, volumetric thermal expansion of the liquid phase, thermal diffusivity, thermal conductivity, and viscosity. Properties of the ternary NaCl-KCl-UCl 3 system that may be used as a fuel bearing salt are being measured. Low-melting eutectic salt compositions are of interest to developers owing to the thermal efficiency. Using salts with low melting temperatures allow reactors to be operated at a lower temperature to improve operation and decrease safety concerns. Confirming low melting behaviors are maintained during composition changes that occur during fission is also an important factor. It is essential to any molten salt reactor developer utilizing a fuel bearing salt to have a complete understanding of the behavior of that fuel salt at a variety of compositions near the eutectic composition they plan to use. This kind of stability is indicated on a phase diagram by low liquidus slopes at compositions bordering the eutectic. Therefore, a thermodynamic model was constructed to determine what compositions of the ternary NaCl, KCl, and UCl 3 system should be studied to support MSR developers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of High-Power Polyphase PCB Coil Systems for Wireless Power Transfer

Printed circuit board (PCB) coils have been proposed prior for implementation as inductive wireless charging coils to minimize size and cost. Utilization of PCBs can allow for a reduced cost, improved manufacturability, and a wide range of geometric customization options. To circumvent material limitations on insulation and thermal performance, parallel paths can be implemented to divide the current per path accordingly. Within this paper, an unconventional high-power PCB coil is designed employing all possible techniques for wiring with axial and radial parallel paths with equivalent transposition to minimize circulating currents. Design studies are simulated in 3D finite element analysis (FEA) to evaluate imbalance between phases with and without transposition. Two experimental prototype coils were fabricated with measurements for self-inductance and mutual inductance between phases. These measurements were validated to be sufficiently consistent with FEA results. Additionally, a method is proposed for a two-step optimization of coupling coefficient and coil losses.

Lewis, Donovin D.↗

Evolution of magnetic field induced ordering in the layered quantum Heisenberg triangular-lattice antiferromagnet Ba 3 CoSb 2 O 9

Quantum fluctuations in the effective spin-12 layered triangular-lattice quantum Heisenberg antiferromagnet Ba 3 CoSb 2 O 9 lift the classical degeneracy of the antiferromagnetic ground state in magnetic field, producing a series of novel spin structures for magnetic fields applied within the crystallographic ab plane, including a celebrated collinear “up-up-down” spin ordering with magnetization equal to 1/3 of the saturation magnetization over an extended field range. Theoretically unresolved, however, are the effects of interlayer antiferromagnetic coupling and transverse magnetic fields on the ground states of this system. Additional magnetic field induced phase transitions are theoretically expected and in some cases have been experimentally observed, but details regarding their number, location, and physical character appear inconsistent with the predictions of existing models. Conversely, an absence of experimental measurements as a function of magnetic-field orientation has left other key predictions of these models untested. To address these issues, in this study we have used specific heat, neutron diffraction, thermal conductivity, and magnetic torque measurements to map out the phase diagram as a function of magnetic field intensity and orientation relative to the crystallographic ab plane. For H||ab, we have discovered an additional magnetic field induced phase transition at low temperature and an unexpected tetracritical point in the high-field phase diagram, which coupled with the apparent second-order nature of the phase transitions eliminates several theoretically proposed spin structures for the high-field phases. Our calorimetric measurements as a function of magnetic field orientation are in general agreement with theory for field-orientation angles close to plane parallel (H||a) but diverge at angles near plane perpendicular; a predicted convergence of two phase boundaries at finite angle and a corresponding change in the order of the field induced phase transition are not observed experimentally. Our results emphasize the role of interlayer coupling in selecting and stabilizing field induced phases, provide guidance on the nature of the magnetic order in each phase, and reveal the need for new physics to account for the nature of magnetic ordering in this archetypal two-dimensional spin-12 triangular-lattice quantum Heisenberg antiferromagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗