Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Speculations on future opportunities to evolve Brayton powerplants aboard the space station

The Space Station provides a unique, low-risk environment in which to evolve new capabilities. In this way, the Space Station will grow in capacity, in its range of capabilities, and its economy of operation as a laboratory and as a center for space operations. Although both Rankine and Brayton cycles, two concepts for solar dynamic power generation, now compete to power the station, this paper confines its attention to the Brayton cycle using a mixture of He and Xe as its working fluid. Such a Brayton powerplant to supply the station's increasing demands for both electric power and heat has the potential to gradually evolve higher and higher performance by exploiting already-evolved materials (ASTAR-811C and molten-Li heat storage), its peak cycle temperature rising ultimately to 1500 K. Adapting the station to exploit long tethers (200 to 300 km long) could yield increases in payloads to LEO, to GEO, and to distant destinations in the solar system. Such tethering of the Space Station would not only require additional power for electric propulsion but also would so increase nuclear safety that nuclear powerplants might provide this power. From an 8000-kWt SP-100 reactor, thermoelectric power generation could produce 300 kWe, or adapted solar-Brayton cycle, 2400 to 2800 kWe.

English, Robert E.↗

Biomass Production and Nutrient Removal by Perennial Energy Grasses Produced on a Wet Marginal Land

Growing dedicated bioenergy crops on marginal land can provide beneficial outcomes including biomass production and energy, resource management, and ecosystem services. We investigated the effects of harvest timing (peak standing crop [PEAK] or after killing frost [KF]) and nitrogen (N) fertilizer rates (0, 56, and 112 kg N ha -1 ) on yield, nutrient concentrations, and nutrient removal rates of perennial grasses on a wet marginal land. We evaluated three monocultures, including switchgrass (Panicum virgatum L., SW), Miscanthus x giganteus (MG), prairie cordgrass (Spartina pectinata Link, PCG), and a polyculture mixture of big bluestem (Andropogon gerardii Vitman), Indiangrass (Sorghastrum nutans (L.) Nash), and sideoats grama (Bouteloua curtipendula Torr., MIX). Increasing the application of N did correlate with increased biomass, concentration, and subsequent removal of nutrients across almost all treatment combinations. In all grass treatments except MG, PEAK harvesting increased yield and nutrient removal. At PEAK harvest, switchgrass is ideal for optimizing both biomass production and nutrient removal. While our results also suggest short-term plasticity for farmers when selecting harvest timing for optimal nutrient removal, KF harvest is recommended to ensure long-term stand longevity and adequate nutrient removal. If the KF harvest is adopted, MG would be the ideal option for optimizing biomass yield potential. Additionally, we found that the yield of polyculture did not vary much with harvest timing, suggesting better yield stability. Future studies should give consideration for long-term evaluation of polyculture mixtures to assess their biomass yields and nutrient removal capacities.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

Preservation of Microalgae, Lignocellulosic Biomass Blends by Ensiling to Enable Consistent Year-Round Feedstock Supply for Thermochemical Conversion to Biofuels

Seasonal variation in microalgae productivity is a significant barrier to economical production of algae biofuels and chemicals. Summer production can be 3–5 times higher than in the winter resulting in uneven feedstock supplies at algae biorefineries. A portion of the summer production must be preserved for conversion in the winter in order to maintain a biorefinery running at capacity. Ensiling, a preservation process that utilizes lactic acid fermentation to limit microbial degradation, has been demonstrated to successfully stabilize algae biomass (20% solids) and algae-lignocellulosic blends (40% algae-60% lignocellulosic biomass, dry basis) for over 6 months, resulting in fuel production cost savings with fewer emissions. Preservation of algae as blends could be beneficial to biorefineries that utilize thermochemical approaches to fuel production as co-processing of algae and lignocellulosic biomass has been observed to enhance biocrude yield and improve oil quality. This study conducts a resource assessment of biomass residues in the southern United States to identify materials available during peak algae productivity and in sufficient quantity to meet the algae storage needs of an algae biofuel industry. Eight feedstocks met the quantity threshold but only three, distillers grains, haylage, and yard waste, were also available in season. Storage experiments utilizing both freshwater and marine strains of microalgae – Scenedesmus acutus, Chlorella vulgaris, Chlorella zofingiensis, Nannochloropsis gaditana, and Porphyridium purpureum – and yard waste were conducted for 30 days. Storage losses were less than 10% in all but one case, and the pH of all but one blend was reduced to less than 4.7, indicating that yard waste is a suitable feedstock for blending with algae prior to storage. To better understand whether the benefits to conversion realized by processing blends might be affected by storage, elemental analysis and bomb calorimetry of pre- and post-storage algae-yard waste blends were conducted to characterize changes occurring during storage. Storing algae biomass as blends with lignocellulosic biomass could be an effective method of mitigating seasonal variability in algae biomass production while retaining the synergistic effect of co-processing algae blends in thermochemical conversion.

09 BIOMASS FUELS↗

Fast extraction of nickel from aqueous media by using ionic metal-organic frameworks

As global demand for stainless steel rapidly increases, supply for minerals such as nickel, manganese, and chromium become more critical. To shift mineral peak production and delay scarcity of alloying minerals, recycling rate of the mineral needs to increase. Development of simple and cost-effective techniques for critical mineral production and recovery from industrial wastewater will lead to enhance the current recycling rate of the mineral and reduce potential hazards of industrial wastewater bearing high concentrations of minerals. Here, in this study, ionic metal-organic framework (iMOF)-based sorbents are successfully designed for critical metal ion extraction from aqueous solution. The iMOFs are highly stable in aqueous solution over wide pH ranges, indicating that they are suitable for use in industrial wastewater with harsh chemical environments. The sorption capacity of iMOFs towards Ni reaches 34.1 mg/g with a removal efficiency of >99.9%. Notably, complete extraction of Ni takes place within 5 min, which is much faster compared to other sorbents. Moreover, the iMOFs can simultaneously coextract multiple minerals, proving their effectiveness as general sorbents for critical mineral recovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Modeling & Size Optimization of Thermal Energy Storage for Iron & Steel Production

Iron and steel production are responsible for 90 million MtCO2 per year in the United States. Hydrogen direct reduction of iron (H2DRI) is a promising pathway for a more sustainable iron production than commercially deployed technologies which rely on natural gas. The H2DRI process requires hydrogen at a temperature of up to 950 degrees C fed into a reduction furnace to produce pellets or briquettes that are used in the downstream iron and steelmaking process. In this work, we propose to use an electrical thermal energy storage (ETES) system, that can use renewable electricity to store high-temperature heat and dispatch it upon demand. Such a system can buffer the H2DRI plant from the variability of electricity prices by charging during curtailment and running the plant from storage during times of peak electricity price. We have developed heat transfer models for two different ETES systems that can be used to heat up hydrogen to the required temperatures: a particle-based ETES and a firebrick ETES. These models are used to evaluate the performance of such a system and support the sizing and preliminary cost estimation. The preliminary results using both models show that designing ETES systems for an industrial-scale H2DRI furnace is feasible. The firebrick ETES system has limited operational duration, which might limit the price buffering effect unless significantly oversized. The particle ETES system heat exchanger has industry-feasible dimensions, but its storage capacity would be decided upon the number of particle storage silos.

25 ENERGY STORAGE↗

High-temperature molten salt thermal energy storage systems

The results of comparative screening studies of candidate molten carbonate salts as phase change materials (PCM) for advanced solar thermal energy storage applications at 540 to 870 C (1004 to 1600 F) and steam Rankine electric generation at 400 to 540 C (752 to 1004 F) are presented. Alkali carbonates are attractive as latent heat storage materials because of their relatively high storage capacity and thermal conductivity, low corrosivity, moderate cost, and safe and simple handling requirements. Salts were tested in 0.1 kWhr lab scale modules and evaluated on the basis of discharge heat flux, solidification temperature range, thermal cycling stability, and compatibility with containment materials. The feasibility of using a distributed network of high conductivity material to increase the heat flux through the layer of solidified salt was evaluated. The thermal performance of an 8 kWhr thermal energy storage (TES) module containing LiKCO3 remained very stable throughout 5650 hours and 130 charge/discharge cycles at 480 to 535 C (896 to 995 F). A TES utilization concept of an electrical generation peaking subsystem composed of a multistage condensing steam turbine and a TES subsystem with a separate power conversion loop was defined. Conceptual designs for a 100 MW sub e TES peaking system providing steam at 316 C, 427 C, and 454 C (600 F, 800 F, and 850 F) at 3.79 million Pa (550 psia) were developed and evaluated. Areas requiring further investigation have also been identified.

Petri, R. J.↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

Poly(norbornene) anion conductive membranes: homopolymer, block copolymer and random copolymer properties and performance

It has previously been shown that phase-separated block copolymers with non-ion conducting (hydrophobic) blocks and ion conducting (hydrophilic) blocks can form efficient ion conducting channels with high ionic mobility and conductivity. Block copolymers can provide a means for phase segregation and ion channel formation while homopolymers and random copolymers have been shown to have lower ion mobility. In this study, the properties of poly(norbornene) based anion exchange membranes (AEMs) comprising homopolymers, block copolymers, and random copolymers with high ion-exchange capacity (IEC) (3.48–4.55 meq. g -1 ) have been investigated and compared. The polymers were cross-linked with N,N,N',N'-tetramethyl-1,6-hexanediamine before casting the membranes to avoid excessive water swelling due to high water uptake. It was shown that high ionic conductivity can be achieved in both random copolymers and homopolymers even in the absence of microphase-separated structures. For example, the conductivity of a random copolymer was 194 mS cm -1 at 80 °C, which was comparable to the block copolymer, 201 mS cm -1 at 80 °C. The H 2 /O 2 fuel cell performance of random copolymer composite membranes showed a peak power density of 3.05 W cm -2 and peak current density of 7.85 A cm -2 at 80 °C compared to block copolymer membranes (peak power density of 3.21 W cm -2 and peak current density of 8.27 A cm -2 at 80 °C). It is more critical that high water transport be achieved in AEMs than achieving a phase-segregated morphology. Finally, the homopolymer, block copolymer, and random copolymer membranes showed <1.35% degradation after aging in 1 M NaOH at 80 °C for 1000 h.

08 HYDROGEN↗

Static and dynamic spin properties in the quantum triangular lattice antiferromagnet Ag 2 CoO 2

In Ag 2 CoO 2 , Co forms triangular lattice layers, which are separated by the metallic (Ag 2 ) block. The magnetic susceptibility and heat capacity measurements show that this material exhibits an antiferromagnetic transition at T N =17.5 K and the Weiss temperature (T Θ ) and the effective moment are -274 K and 1.62μ B , respectively, indicating that the Co ion carries spin (S) 1/2 and has a strongly frustrated state with T Θ /T N =15.7. A density functional theory calculation confirmed that the valence state of the Co ions is 2+ and the low-spin state with S=1/2 is realized at reduced on-site Coulomb interaction on Co. We performed elastic and inelastic neutron scattering experiments in a powder sample of Ag 2 CoO 2 . Although no noticeable magnetic Bragg peaks were observed below T N , distinct magnetic excitations were observed in the inelastic neutron scattering experiments. The excitations are consistent with those expected for the S=1/2 Heisenberg triangular lattice antiferromagnet. These results suggest that the ordered moment is reduced due to the quantum effect, which explains the absence of the magnetic Bragg peaks. Our results thus suggest that Ag 2 CoO 2 is a good candidate to realize a quantum Heisenberg triangular lattice antiferromagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Investigation of a Physisorption-Based Hydrogen Storage System

This study discusses a practical system utilizing the principle of physisorption where hydrogen is weakly bound to the surface of a nanoporous silica aerogel blanket as an alternative to high-pressure and cryogenic hydrogen storage. Three different experiments are conducted to simulate various scenarios of such a storage method: change in pressure and change of scale. Transient responses of the charging and discharging cycles are of particular interest. It is observed that hydrogen uptake can be increased by up to 36-38 % at ambient conditions and 77 K when utilizing the aerogel blankets. Packing density, or the artificial increase of surface per volume, increases storage capacity as it is a mainly surface-driven phenomenon. High-pressure testing up to 50 bar showed benefits of the aerogel addition whereas the maximum uptake improvement was observed for 2 bar with a 105.3 % improvement over an empty vessel at identical conditions corresponding to 6.43 wt%. The scale-up of the system is highly sensitive to the design of the internal cooling design as aerogels are poor thermal conductors reducing the transient response of such systems. Furthermore, the high mass of metal-based pressure vessels further delays the thermal response. This makes the system suitable for day to week-long hydrogen storage but not for peak-shaving or load balancing.

Marcel Otto↗

Impact of nano-scale cavities on hydrogen storage and retention in yttrium hydride

Here, in situ synchrotron high-energy x-ray diffraction experiments and detailed transmission electron microscopy (TEM) characterization were conducted on as-fabricated and neutron-irradiated yttrium hydrides. The high-resolution synchrotron x-ray diffraction revealed minor α yttrium and major δ yttrium hydride phases in all specimens. Specimens were subject to heat treatments (heating-cooling cycles), and the intensity of α yttrium partially and completely disappeared in as-fabricated and neutron-irradiated specimens, respectively. The disappearance of α yttrium was unforeseen because hydrogen was expected to leave δ phase, causing an increase in α yttrium diffraction peak intensity. This observation indicated a surplus of hydrogen in the specimens where it was odd for hydride-forming early transition metal elements. The subsequent through-focus TEM characterization discovered nanometric cavities in both as-fabricated and neutron-irradiated yttrium hydride specimens for the first time. Two types of cavities were identified as fabrication-caused and irradiation-induced. The fabrication-caused cavities were associated with regions having linear deformation features, interfaces, and inclusions. The irradiation-induced cavities were observed as being formed isolated in the yttrium hydride phase. The presence of such nanometric cavities was considered as potential hydrogen storage pockets where the overall hydrogen storing capacity of yttrium hydride would be enhanced.

36 MATERIALS SCIENCE↗