Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “passivation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗

Trap-Assisted Dopant Compensation Prevents Shunting in poly-Si Passivating Interdigitated Back Contact Silicon Solar Cells

Interdigitated back contact (IBC) solar cells achieve the highest efficiencies of single-junction architectures, but complicated patterning of the rear fingers and spreading of dopants during processing inhibit their mainstream adoption due to concerns of shunting between the IBC fingers. One method of simplifying patterning at the rear is by using contact masks combined with plasma-enhanced chemical vapor deposition (PECVD) or ion implantation. However, the intrinsic isolation region becomes contaminated during high-temperature annealing by lateral diffusion of dopants and during masked PECVD by spreading of dopant radicals through region between the mask and the substrate. Despite this contamination, we show through scanning spreading resistance microscopy and Kelvin probe force microscopy that a ~20 µm wide compensating region exists with high enough resistivity to prevent shunting. We model this p-i-n poly-Si system using two simulation models: a simple resistor model considering only the capture of charge carriers by trap defects in poly-Si to reduce the conductivity, and a more refined 1-dimensional finite element model using Poisson’s equation, drift-diffusion equations, and recombination of carriers. Using this model, we show that high defect density significantly decreases the current across the region between the p- and n-type fingers, preventing shunting.

atom probe↗

Effect of Dopant Compensation on the Conductivity of the Intrinsic poly-Si Isolation Region in Passivated IBC Silicon Solar Cells

The performance of IBC solar cells depends on the ability of this region to electrically isolate the doped fingers so that shunting does not occur and reduce the cell fill factor. We report on simulations which model the region between the p- and n-type poly-Si fingers of interdigitated back contact (IBC) solar cells as a series of resistors extending from one doped finger to the other. We demonstrate that the existence of a well compensated region between the doped fingers is enough to prevent shunting and loss of cell performance, despite contamination of dopants from the opposing dopant fingers. We show through these simulations that a net doping concentration below ~1018 cm-3 will enable a high resistivity and identify the conditions under which this highly resistive region forms despite imperfect finger edges. Additionally, we apply this analysis to tails measured by time-of-flight secondary ion mass spectrometry and confirm this hypothesis for our experimentally measured tails.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Plasma Etching on Dopant Compensation between p- and n-Type Poly-Si Fingers in Passivated Interdigitated Back Contact Solar Cells

Efficiencies surpassing 26% have been achieved for single-junction Si solar cells based on the interdigitated back contact (IBC) architecture. However, the possibility of lateral shunting between the doped fingers has limited industrial adoption thus far. To avoid this possibility of shunt, complicated patterning techniques of the doped rear fingers have been developed, but spreading can still occur through multiple pathways during cell processing. Patterning can be simplified by using masked plasma-enhanced chemical vapor deposition (PECVD), but spreading during deposition will also lead to contamination of the isolation region between doped fingers. We significantly reduce the effect of this spreading through a short, gentle plasma etching step, which enables a trap-assisted compensation mechanism to take effect more easily than without the plasma etch. These two effects combined allow for the use of a simple patterning technique while still maintaining a highly resistive region between the doped fingers, and will reduce the complexity of IBC cell fabrication overall.

atom probe↗

Damp Heat Degradation of Polycrystalline Silicon Passivated Contacts

After 1000 hours of damp heat exposure at 85% humidity and 85 C, LPCVD n-poly and p-poly are stable for both metallized and non-metallized regions whereas for PECVD, only n-poly is stable; PECVD p-poly suffers significant degradation and defects became more pronounced with exposure time; and PECVD p-poly degrades more than LPCVD p-poly with or without additional dielectric layers (i.e., SiNx + Al2O3 stack).

damp heat degradation↗

Performance of Subyearling Fall Chinook Salmon Tagged with 8-, 9-, and 12-mm Passive Integrated Transponder Tags in the Snake River

Abstract Inferences based on tagged individuals from a population are limited in part by the minimum size of fish that can be tagged. Smaller tags allow a greater proportion of a population to be represented by tagging and should reduce potential tag effects on fish performance. We evaluated different performance metrics of juvenile fall Chinook Salmon Oncorhynchus tshawytscha tagged with 8-, 9-, and 12-mm PIT tags in the Snake River. We did not find evidence that posttagging mortality of 45–49-mm-FL fish tagged with 8-mm tags was higher than the posttagging mortality of larger fish tagged with 9- and 12-mm tags. The incisions of fish tagged with 8-mm tags using 14-guage needles healed faster than those of fish tagged with larger tags using 12-guage needles. For individuals that received 8-mm tags, growth in length and mass was higher for 45–49-mm fish than for 50–59-mm fish and 60-mm and larger fish. Growth of the larger size-classes (50–59 and ≥60 mm) was also generally higher for those tagged with 8-mm tags compared to those tagged with 9- and 12-mm tags, respectively. There were no strong relationships between tag burden (i.e., tag weight expressed as a percentage of fish weight) at the time of tagging and growth metrics for any tag size or fish size-class. Releases made to compare the detection efficiency of the three tag types in the juvenile fish bypass at Lower Granite Dam, Washington, showed that 99–100% of all fish were detected. Survival of fish from rearing areas to Lower Granite Dam generally increased with fish size and varied by year, but there was no strong evidence of a tag size effect. The 8-mm PIT tag allowed us to represent a larger portion (i.e., 6.2–24.1%) of the subyearling fall Chinook Salmon population in the Snake River without compromising fish performance or detectability at the dam.

Tiffan, Kenneth F.↗

Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector

The Comprehensive Test Ban Treaty (CTBT) bans nuclear weapons testing and establishes the International Monitoring System (IMS) for the purpose of treaty verification. IMS is a detector network that confirms that global nuclear activity is peaceful in nature. These detector systems use β-γcoincidence measurements to characterize atmospheric samples containing radioxenon isotopes. The goal of this work is to use the system consisting of two sodium iodide detectors and two PIPSbox detectors to characterize isotopically pure samples of 131m Xe, 133m Xe, 133 Xe, and 135 Xe via β, γ, and β-γ coincidence measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of passive vortex generators to enhance vertical mixing in an open raceway pond

A novel use of vortex generators in a raceway pond is described here, with the flow field quantitatively simulated using computational fluid dynamics using the large eddy simulation turbulence model. Persistence lengths of the swirling motion generated by the vortex generators indicate that significant vertical mixing can be achieved by placing vortex generators in the straight section opposite the paddle wheel, downstream of the first hairpin bend. Relatively simple vortex generators are capable of creating stronger swirling motions that persist for a longer distance than those created by the paddle wheel. For optimal performance, vortex generators are positioned side by side but in opposite directions, and their diameters should be equal to or slightly less than the desired liquid depth. The optimal length of a 0.18 m diameter vortex generator in a 0.2 m deep pond was determined to be 0.3 m. As a result, it has been demonstrated that a longer persistence length is achieved by inducing a swirling motion with its rotational axis parallel to the primary flow direction.

09 BIOMASS FUELS↗