Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (~0.8 ps–20 ps). Furthermore, maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion temperature and rotation fluctuation measurements with ultra-fast charge exchange recombination spectroscopy (UF-CHERS) in the DIII-D tokamak

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

Truong, D. D. (ORCID:0000000285732539)↗

EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

Design, calibration, and performance of a uniaxial pressure cell for neutron scattering studies of quantum magnetism

Here we provide an overview of a pressure cell designed to apply uniaxial pressure to single crystals for the study, by neutron scattering techniques, of strongly correlated magnetic systems and, in particular, quantum magnets. A detailed overview of the pressure cell components, their requirements, and links to the scientific and technical specifications are presented. The pressure cell is able to accommodate a 200 mm 3 single crystal that can be pressurized up to 2 GPa at cryogenic temperatures. The pressure cell is consistent with the requirements of inelastic neutron scattering and, importantly, neutron polarization analysis. A particular strength of the uniaxial pressure cell is the highly uniform and low background for a wide scattering angle of 360° horizontally and ±20° vertically. We show the performance of the uniaxial pressure cell using a relevant neutron scattering instrument, the polarized diffuse scattering instrument, D7. The experiments confirm that the cell complies with the scientific and technical requirements. This uniaxial pressure cell will provide a useful additional tool in the sample environment suite available for the study of quantum magnetism.

47 OTHER INSTRUMENTATION↗

Photochemistry sample sticks for inelastic neutron scattering

Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. Furthermore, these new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

Deviations from the Porter-Thomas Distribution due to Nonstatistical 𝛾 Decay below the 150 Nd Neutron Separation Threshold

We introduce a new method for the study of fluctuations of partial transition widths based on nuclear resonance fluorescence experiments with quasimonochromatic linearly polarized photon beams below particle separation thresholds. It is based on the average branching of decays of 𝐽=1 states of an even-even nucleus to the 2$^{+}_{1}$ state in comparison to the ground state. Between 5 and 7 MeV, a constant average branching ratio for 𝛾 decays from 1 − states of 0.490(16) is observed for the nuclide 150 Nd. Assuming 𝜒 2 -distributed partial transition widths, this average branching ratio is related to a degree of freedom of 𝜈 = 1.93⁢(12), rejecting the validity of the Porter-Thomas distribution, requiring 𝜈 = 1. The observed deviation can be explained by nonstatistical effects in the 𝛾-decay behavior with contributions in the range of 9.4(10)% up to 94(10)%.

150 ≤ A ≤ 189↗