Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Hysteresis curves reveal the microscopic origin of cooperative CO 2 adsorption in diamine-appended metal–organic frameworks

Diamine-appended metal-organic frameworks (MOFs) of the form Mg 2 (dobpdc)(diamine) 2 adsorb CO 2 in a cooperative fashion, exhibiting an abrupt change in CO 2 occupancy with pressure or temperature. This change is accompanied by hysteresis. While hysteresis is suggestive of a first-order phase transition, we show that hysteretic temperature-occupancy curves associated with this material are qualitatively unlike the curves seen in the presence of a phase transition; they are instead consistent with CO 2 chain polymerization, within one-dimensional channels in the MOF, in the absence of a phase transition. Here, our simulations of a microscopic model reproduce this dynamics, providing a physical understanding of cooperative adsorption in this industrially important class of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2000-2001 California Statewide Household Travel Survey

The 2000-2001 California Statewide Household Travel Survey, conducted under the auspices of the California Department of Transportation, was conducted between October 2000 and December 2001 among households located in each of California's 58 counties. The purpose of the study was to update the statewide database of household socioeconomic and travel information and helped to refine travel estimates, models, and forecasts throughout California. The survey was an essential element in determining statewide and regional travel patterns. A total of 17,040 households participated in the survey, contributing household socioeconomic and travel data. Travel variables collected include trip times, mode, activity at location, origin and destination, and vehicle occupancy, among other travel-related data from 134,173 trips. Residents completed diary records of their daily travel over a 24-hour (weekday) or 48-hour period (Friday/Saturday or Sunday/Monday pair).

1Hz data↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Ability of Developmentally Precocious Estrogen Signaling to Recapitulate Ovarian Transcriptomes and Follicle Dynamics in Alligators from a Contaminated Lake

Concern has grown in recent decades over anthropogenic contaminants that interfere with the functioning of endocrine hormones. However, mechanisms connecting developmental processes to pathologies associated with endocrine-disrupting chemical (EDC) exposure are poorly understood in naturally exposed populations. We sought to a) characterize divergence in ovarian transcriptomic and follicular profiles between alligators originating from a historically EDC-contaminated site, Lake Apopka, and a reference site; b) test the ability of developmentally precocious estrogen exposure to recapitulate site-associated patterns of divergence; and c) test whether treatment with exogenous follicle-stimulating hormone (FSH) is capable of rescuing phenotypes associated with contaminant exposure and/or embryonic estrogen treatment. Alligators eggs were collected from a contaminated site and a reference site, and a subset of eggs from the reference site were treated with estradiol (E2) during embryonic development prior to gonadal differentiation. After hatching, alligators were raised under controlled laboratory settings for 5 months. Juveniles from both sites were divided and treated with exogenous FSH. Histological analyses and RNA-sequencing were conducted to characterize divergence in ovarian follicle dynamics and transcriptomes between sites, between reference and E2-treated animals, and between FSH-treated and nontreated animals. We observed broad site-of-origin divergence in ovarian transcriptomes and reductions in ovarian follicle density between juvenile alligators from Lake Apopka and the reference site. Treating embryos from the reference site with E2 overwhelmingly recapitulated transcriptional and histological alterations observed in Lake Apopka juveniles. Ovarian phenotypes observed in Lake Apopka alligators or resulting from estrogen treatment were only partially rescued by treatment with exogenous FSH. Recapitulation of ovarian abnormalities by precocious E2 revealed a relatively simple mechanism underlying contaminant-induced pathologies in a historical example of environmental endocrine disruption. Findings reported here support a model where the developmental timing of estrogen signaling has the potential to permanently alter ovarian organization and function.

59 BASIC BIOLOGICAL SCIENCES↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum dynamics of a nucleon in the Fermi accelerator

Highlights: • In nuclear physics, the Fermi accelerator is a coherent open quantum system. • There is not a true equilibrium for a nucleon‘s mean-energy in the Fermi accelerator. • Occupation of higher energy eigen-states remains even after the mean-energy plateaus. • This work paves the way for work on quantum tunnelling in the Fermi accelerator. The quantum dynamics of a particle in a one-dimensional box with an oscillating wall (the Fermi accelerator) is investigated. The model is applied to the motion of a single nucleon in the mean-field potential of a heavy atomic nucleus whose surface vibrates. By directly solving the time-dependent Schrödinger equation, both the state of the particle and its mean-energy are studied. The effects of the frequency of the wall oscillation on the nucleon’s energy are addressed. Its energy oscillates in phase with the moving wall for all frequencies, showing no chaotic behaviour. There is a large initial peak of the nucleon’s energy as the particle adjusts to the sudden change in the size of the box and a varying relaxation time as it plateaus towards lower energy and a partial equilibrium. Small oscillations in energy continue, since there cannot be a true equilibrium while the wall is moving. The quantum coherence between the different parts of the nucleon’s wave-function in real space is very much preserved. This research lays the foundation for future investigations into quantum tunnelling in the Fermi accelerator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QUOTAS: A New Research Platform for the Data-driven Discovery of Black Holes

We present QUOTAS, a novel research platform for the data-driven investigation of supermassive black hole (SMBH) populations. While SMBH data—observations and simulations—have grown in complexity and abundance, our computational environments and tools have not matured commensurately to exhaust opportunities for discovery. To explore the BH, host galaxy, and parent dark matter halo connection—in this pilot version—we assemble and colocate the high-redshift, z > 3 quasar population alongside simulated data at the same cosmic epochs. As a first demonstration of the utility of QUOTAS, we investigate correlations between observed Sloan Digital Sky Survey (SDSS) quasars and their hosts with those derived from simulations. Leveraging machine-learning algorithms (ML), to expand simulation volumes, we show that halo properties extracted from smaller dark-matter-only simulation boxes successfully replicate halo populations in larger boxes. Next, using the Illustris-TNG300 simulation that includes baryonic physics as the training set, we populate the larger LEGACY Expanse dark-matter-only box with quasars, and show that observed SDSS quasar occupation statistics are accurately replicated. First science results from QUOTAS comparing colocated observational and ML-trained simulated data at z3 are presented. QUOTAS demonstrates the power of ML, in analyzing and exploring large data sets, while also offering a unique opportunity to interrogate theoretical assumptions that underpin accretion and feedback models. QUOTAS and all related materials are publicly available at the Google Kaggle platform. (The full data set—observational data and simulation data—are available at: https://www.kaggle.com/ and the codes are available at:https://www.kaggle.com/datasets/quotasplatform/quotas)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum spin liquids bootstrapped from Ising criticality in Rydberg arrays

Arrays of Rydberg atoms constitute a highly tunable, strongly interacting venue for the pursuit of exotic states of matter. We develop a strategy for accessing a family of fractionalized phases known as quantum spin liquids in two-dimensional Rydberg arrays. We specifically use effective field theory methods to study arrays assembled from Rydberg chains tuned to an Ising phase transition that famously hosts emergent fermions propagating within each chain. This highly entangled starting point allows us to naturally access spin liquids familiar from Kitaev's honeycomb model—albeit from an entirely different framework. In particular, we argue that finite-range repulsive Rydberg interactions, which frustrate nearby symmetry-breaking orders, can enable coherent propagation of emergent fermions between the chains in which they were born. Delocalization of emergent fermions across the full two-dimensional Rydberg array yields a gapless Z 2 spin liquid with a single massless Dirac cone. Here, the Rydberg occupation numbers exhibit universal power-law correlations that provide a straightforward experimental diagnostic of this phase. We further show that explicitly breaking symmetries perturbs the gapless spin liquid into gapped, topologically ordered descendants: Breaking lattice symmetries generates toric-code topological order, whereas introducing Floquet-mediated chirality generates non-Abelian Ising topological order. In the toric-code phase, we analytically construct microscopic incarnations of non-Abelian defects, which can be created and transported by dynamically controlling the atom positions in the array. Our work suggests that appropriately tuned Rydberg arrays provide a cold-atoms counterpart of solid-state “Kitaev materials” and, more generally, it spotlights a different angle for pursuing experimental platforms for Abelian and non-Abelian fractionalization.

36 MATERIALS SCIENCE↗

Generalized hydrodynamic analysis of transport through a finite open nanopore for two-component single-file systems

Single-file diffusion (SFD) in finite open nanopores is characterized by nonzero spatially varying tracer diffusion coefficients within a generalized hydrodynamic description. This contrasts with infinite SFD systems where tracer diffusivity vanishes. In standard tracer counterpermeation (TCP) analysis, two reservoirs, each containing a different species, are connected to opposite ends of a finite pore. Here, we implement an extended TCP analysis to allow the two reservoirs to contain slightly different mixtures of the two species. Then, determination of diffusion fluxes through the pore allows extraction of diffusion coefficients for near-constant partial concentrations of the two species. This analysis is applied for a lattice-gas model describing two-component SFD through a finite linear pore represented by a one-dimensional array of cells. Two types of particles, A and B, can hop only to adjacent empty cells with generally different rates, $h_A$ and $h_B$. Particles are noninteracting other than exclusion of multiple cell occupancy. Results reveal generalized hydrodynamic tracer diffusion coefficients which adopt small values inversely proportional to pore length in the pore center, but which are strongly enhanced near pore openings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Material efficiency and climate change mitigation of passenger vehicles

A transition to electric vehicles and renewable energy is currently underway but may not be rapid enough in order to reach ambitious climate change mitigation targets. Therefore, additional, preferably instantaneous, measures are needed for quick emissions reductions, which is where material efficiency (ME) could constitute a promising solution. ME strategies include but are not limited to vehicle lightweighting through material substitution, increased recycling of materials, reuse and remanufacturing of vehicle components, vehicle downsizing (switching to a smaller vehicle) and more intensive use by means of increased vehicle occupancy through sharing practices. While recent analyses have focused on a narrow subset of these, we find striking differences in the overall potential of different strategies to decrease vehicular carbon footprints. Downsizing and more intensive use offer the largest mitigation potential but strongly depend on consumer behavior and are highly sensitive to modeling assumptions. Combined, the analyzed strategies can achieve emission reductions of up to 57% over the life cycle of a single vehicle, which is comparable to up to 83% achieved through a shift to low-carbon energy supply. ME can cut carbon footprints of already efficient vehicles charging renewable electricity by half again. This makes ME both an excellent short-term solution for climate change mitigation targeting the light vehicle sector but also an important complementary strategy to the long-term transition towards electric vehicles and renewable energy supply.

54 ENVIRONMENTAL SCIENCES↗

Integrating Human Factors in Dynamic Rideshare Assignment: Willingness-To-Pay for Delay

Dynamic ride-sharing (DRS) has been projected to be a key solution to lowering system-wide congestion. Despite recent developmental progress, demand studies for DRS suggest low levels of willingness for travelers to use such services. The disconnect between DRS system designs and user preferences limits the application impacts of DRS in the real world. Therefore, this paper aims to design a new DRS trip/vehicle assignment strategy by considering the user preferences of choices under different levels of service. In this study, an agent-based simulation approach is used to model a fleet of shared vehicles that allows DRS. An optimization model is developed to match riders to vehicles while accounting for traveler delay and delay acceptance. Travelers are also dynamically issued predictive discounts, catered to their expected willingness to pay, to incentivize them to accept longer trip delays. Results show that the proposed approach can improve system efficiency by increasing average vehicle occupancy by up to 1.0 persons/trip and DRS acceptance by up to 38.9% depending on fleet size. Additionally, congestion is eased through the decrease of empty vehicle miles traveled by up to 7.1%.

Paul, Joseph↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

On the Ordering Mechanism of Cu + in 2D van der Waals Multiferroic CuCrP 2 S 6

CuCrP 2 S 6 is a van der Waals multiferroic where the tunable Cu + sublattice underpins its exceptional ferroelectric and electronic switching properties. Yet, the microscopic mechanism governing Cu + ordering has remained elusive. Here, we combine single-crystal X-ray and neutron diffraction with pair distribution function analysis to uncover a temperature-driven evolution of Cu + ordering, giving rise to an incommensurate quasi-antipolar phase between the paraelectric and antiferroelectric states. The modulation originates from correlated Cu + occupancy redistribution coupled to breathing distortion of surrounding S 3 triangles, establishing a symmetry-adapted lattice distortion mode. Diffuse scattering persisting over 35 K above the transition confirms that the structural instability follows an order-disorder mechanism. The spontaneous off-centering of Cu + positions CuCrP 2 S 6 as a model platform for correlated order-disorder phenomena in 2D layered ferroics, and provides design principles for next-generation memory and logic devices.

ferroelectrics↗

Bosonic field digitization for quantum computers

Quantum simulation of quantum field theory is a flagship application of quantum computers that promises to deliver capabilities beyond classical computing. The realization of quantum advantage will require methods that can accurately predict error scaling as a function of the resolution and parameters of the model and that can be implemented efficiently on quantum hardware. In this paper, we address the representation of lattice bosonic fields in a discretized field amplitude basis, develop methods to predict error scaling, and present efficient qubit implementation strategies. A low-energy subspace of the bosonic Hilbert space, defined by a boson occupation number cutoff, can be represented with exponentially good accuracy by a low-energy subspace of a finite-size Hilbert space. The finite representation construction and the associated errors are directly related to the accuracy of the Nyquist-Shannon sampling and the finite Fourier transforms of the boson number states in the field and the conjugate-field bases. We analyze the relation between the boson mass, the discretization parameters used for wave function sampling, and the finite representation size. Numerical simulations of small size Φ 4 problems demonstrate that the boson mass optimizing the sampling of the ground state wave function is a good approximation to the optimal boson mass yielding the minimum low-energy subspace size. However, we find that accurate sampling of general wave functions does not necessarily result in accurate representation. Finally, we develop methods for validating and adjusting the discretization parameters to achieve more accurate simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗