Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

OSCAR-Mike: Why not ATAK?

The Office of Nuclear Smuggling Detection and Deterrence (NSDD) is evaluating methods to increase the probability that international partners will detect radioactive materials. One proposed method to accomplish this goal is to improve communications within teams operating in challenging environments. The goal of these improvements would be to enable remote monitoring of detection equipment, share data among end users in the field and subject matter experts, and integrate data from radiation detectors with other types of sensors and camera systems. Accomplishing this goal has the potential to improve the capabilities of currently deployed NSDD equipment. During FY 2021, Oak Ridge National Laboratory demonstrated some core and expanded capabilities of the Android Team Awareness Kit (ATAK), a situational awareness application developed by the US Department of Defense, to enable precision targeting, navigation, and data sharing. During FY 2022, Oak Ridge National Laboratory developed software requirements for an NSDD team awareness kit–based system. The requirements were developed by liaising with NSDD management and subject matter experts to determine NSDD’s needs and by reviewing available software and hardware solutions with US Department of Defense team awareness kit program managers and developers and radiation detection equipment vendors.

97 MATHEMATICS AND COMPUTING↗

Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological and seawater samples from the marine and terrestrial environment of Amchitka Island adjacent to the three detonation sites and at a background or reference site, Adak Island, 180 miles to the east. Consistent with the goals of the Amchitka LTS&M Plan, four data quality objectives (DQOs) were developed for the 2011 sampling event.

54 ENVIRONMENTAL SCIENCES↗

Imaging analysis of nuclear antiviral factors through direct detection of incoming adenovirus genome complexes

Recent studies involving several viral systems have highlighted the importance of cellular intrinsic defense mechanisms through nuclear antiviral proteins that restrict viral propagation. These factors include among others components of PML nuclear bodies, the nuclear DNA sensor IFI16, and a potential restriction factor PHF13/SPOC1. For several nuclear replicating DNA viruses, it was shown that these factors sense and target viral genomes immediately upon nuclear import. In contrast to the anticipated view, we recently found that incoming adenoviral genomes are not targeted by PML nuclear bodies. Here we further explored cellular responses against adenoviral infection by focusing on specific conditions as well as additional nuclear antiviral factors. In line with our previous findings, we show that neither interferon treatment nor the use of specific isoforms of PML nuclear body components results in co-localization between incoming adenoviral genomes and the subnuclear domains. Furthermore, our imaging analyses indicated that neither IFI16 nor PHF13/SPOC1 are likely to target incoming adenoviral genomes. Thus our findings suggest that incoming adenoviral genomes may be able to escape from a large repertoire of nuclear antiviral mechanisms, providing a rationale for the efficient initiation of lytic replication cycle. - Highlights: • Host nuclear antiviral factors were analyzed upon adenovirus genome delivery. • Interferon treatments fail to permit PML nuclear bodies to target adenoviral genomes. • Neither Sp100A nor B targets adenoviral genomes despite potentially opposite roles. • The nuclear DNA sensor IFI16 does not target incoming adenoviral genomes. • PHF13/SPOC1 targets neither incoming adenoviral genomes nor genome-bound protein VII.

60 APPLIED LIFE SCIENCES↗

Initial Component Testing for a Germanium Array Cryostat

This report describes progress on the construction of two ultra-low-background cryostats that are part of the NA-22 funded “Radionuclide Laboratories” (RN Labs) project. Each cryostat will house seven high-purity germanium crystals (HPGe). These cryostats are being built from a limited set of materials that are known to have very low levels of radioactive impurities. The RN Labs instrument is designed to take advantage of low background performance, high detection efficiency, and γ-γ coincidence signatures to provide unprecedented gamma spectroscopy sensitivity. The project is focused on improving gamma analysis capabilities for nuclear detonation detection (NDD) applications. The instrument also has the potential for basic nuclear physics research. Section 1 provides the background for the project. Section 2 discusses germanium crystal acceptance testing. Design problems were found after the first delivery of new detectors from the vendor, Canberra Semiconductors. The first four crystals were returned for repair, resulting in a delay in crystal procurement. Section 3 provides an update on copper electroforming. In general, electroforming parts for RN Labs has proceeded smoothly, but there have been recent problems in electroforming three large copper parts necessary for the project. Section 4 describes the first round of testing for the instrument: anti-cosmic scintillator testing, electronics testing, and initial vacuum testing. Section 5 concludes with an overall description of the state of the project and challenges that remain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting quantum interference device microsusceptometer balanced over a wide bandwidth for nuclear magnetic resonance applications

Superconducting Quantum Interference Device (SQUID) microsusceptometers have been widely used to study magnetic properties of materials at microscale. As intrinsically balanced devices, they could also be exploited for direct SQUID-detection of nuclear magnetic resonance (NMR) from micron sized samples, or for SQUID readout of mechanically detected NMR from submicron sized samples. Here, we demonstrate a double balancing technique that enables achievement of very low residual imbalance of a SQUID microsusceptometer over a wide bandwidth. In particular, we can generate ac magnetic fields within the SQUID loop as large as 1 mT, for frequencies ranging from dc up to a few MHz. As an application, we demonstrate direct detection of NMR from {sup 1}H spins in a glycerol droplet placed directly on top of the 20 μm SQUID loops.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-pseudospin intertwined excitation at the ν = 1 bilayer quantum Hall state investigated by nuclear-spin relaxation

We investigate the electron spin degree of freedom at the imbalanced density bilayer ν = 1 quantum Hall states using the resistively detected nuclear-spin-lattice relaxation rate 1/T{sub 1}. Our measurements reveal a continuous change in 1/T{sub 1} for σ = 1 to 0, suggesting that the balanced density ν = 1 state also exhibits electron-spin fluctuations. Moreover, the value of 1/T{sub 1} in the back layer (the layer from which electrons are transferred to the front layer) increases at intermediate density imbalance states. This indicates that the low-energy electron-spin mode, similar to a mode observed in Skyrmion crystals, might extend across the two layers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background Suppression Effects on Signal Estimation

Gamma detectors at border crossings are intended to detect illicit nuclear material. One performance challenge involves the fact that vehicles suppress the natural background, thus potentially reducing detection probability for threat items. Methods to adjust for background suppression have been considered in related but different settings. Here, methods to adjust for background suppression are tested in the context of signal estimation. Adjustment methods include several clustering options. We find that for the small-to-moderate suppression magnitudes exhibited in the analyzed data, suppression adjustment is only moderatel helpful in locating the signal peak, and in estimating its width or magnitude.

99 GENERAL AND MISCELLANEOUS↗

Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies

The International Atomic Energy Agency (IAEA) has the responsibility to carry out independent inspections of all nuclear material and facilities subject to safeguards agreements in order to verify compliance with non-proliferation commitments. New technologies have been continuously explored by the IAEA and Member States to improve the verification measures to account for declared inventory of nuclear material and detect clandestine diversion and production of nuclear materials. Even with these efforts, a technical safeguards challenge has remained for decades for the case of developing a method in identifying possible diversion of nuclear fuel pins from the Light Water Reactor (LWR) spent fuel assemblies. We had embarked on this challenging task and successfully developed a novel methodology in detecting partial removal of fuel from pressurized water reactor spent fuel assemblies. The methodology uses multiple tiny neutron and gamma detectors in the form of a cluster and a high precision driving system to obtain underwater radiation measurements inside a Pressurized Water Reactor (PWR) spent fuel assembly without any movement of the fuel. The data obtained in such a manner can provide spatial distribution of neutron and gamma flux within a spent fuel assembly. The combined information of gamma and neutron signature is used to produce base signatures and they are principally dependent on the geometry of the detector locations, and exhibit little sensitivity to initial enrichment, burn-up or cooling time. A small variation in the fuel bundle such as a few missing pins changes the shape of the signature to enable detection. This resulted in a breakthrough method which can be used to detect pin diversion without relying on the nuclear power plant operator's declared operation data. Presented are the results of various Monte Carlo simulation studies and experiments from actual commercial PWR spent fuel assemblies.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deliberate Motion Analytics Applied to CUAS Sensor Fusion

The Advanced Reactor Safeguards and Security (ARSS) program in the Department of Energy’s Office of Nuclear Energy (DOE-NE) seeks to identify new technology solutions for safeguards and security challenges associated with domestic deployment of advanced nuclear reactors. Research in the ARSS program is investigating alternative physical protection system (PPS) approaches that leverage new detection technologies. This report shows test results from a new form of artificial intelligence (AI) that is called deliberate motion analytics (DMA) when used to spatially and temporally fuse active radar and passive radio frequency (RF) detection that significantly improves detection of uncrewed aircraft systems (UASs). DMA is designed to filter out false positive alarms yet provide highly reliable intrusion detection at nuclear power plants (NPPs) and advanced small modular reactor (ASMR) perimeters. This form of AI is considered to be an enabling technology for security of the future and supports the ARSS investigation of alternative PPSs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Time-Encoded Imagers

We have developed two neutron detector systems based on time-encoded imaging and demonstrated their applicability toward non-proliferation missions. The 1D-TEI system was designed for and evaluated against the ability to detect Special Nuclear Material (SNM) in very low signal to noise environments; in particular, very large stand-off and/or weak sources that may be shielded. We have demonstrated significant detection (>5 sigma) of a 2.8e5 n/s neutron fission source at 100 meters stand-off in 30 min. If scaled to an IAEA significant quantity of Pu, we estimate that this could be reduced to as few as ~5 minutes. In contrast to simple counting detectors, this was accomplished without the need of previous background measurements. The 2D-TEI system was designed for high resolution spatial mapping of distributions of SNM and proved feasibility of twodimensional fast neutron imaging using the time encoded modulation of rates on a single pixel detector. Because of the simplicity of the TEI design, there is much lower systematic uncertainty in the detector response typical coded apertures. Other imaging methods require either multiple interactions (e.g. neutron scatter camera or Compton imagers), leading to intrinsically low efficiencies, or spatial modulation of the signal (e.g., Neutron Coded Aperture Imager (Hausladen, 2012)), which requires a complicated, high channel count, and expensive position sensitive detector. In contrast, a single detector using a time-modulated collimator can encode directional information in the time distribution of detected events. This is the first investigation of time-encoded imaging for nuclear nonproliferation applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking of moving radioactive sources

A system for detecting unsecured nuclear materials. Whereas current portal monitors rely in part on physical prominence to deter materials from entering the country, their application at intra-modal transport points may actually serve to divert the movement of nuclear materials rather than aid in interception. A flexible and low-profile system has been developed for unobtrusive detection and tracking of radioactive sources in transit suited for deployment at traffic choke points such as rest stops, toll collection plazas, truck stops, and bridges. The system includes gamma radiation detectors, networking for linking these detectors, signal processing algorithms, and a central processing and control unit.

Klann, Raymond↗

SuperCDMS Background Models for Low-Mass Dark Matter Searches

An abundance of astrophysical and cosmological evidence indicates the existence of a non-luminous, non-baryonic form of matter, called dark matter, that is approximately a quarter of all energy in the universe. One promising candidate for dark matter is the Weakly Interacting Massive Particle (WIMP) which interacts with baryonic matter at most on the scale of the weak force. The Cryogenic Dark Matter Search (CDMS) experiment aims to detect the nuclear recoils induced by the elastic scattering of WIMPs off of germanium nuclei. This is a rare signal and difficult to detect, especially the low-energy recoils that are produced by low-mass dark matter. The CDMS project operated at the Soudan Underground Laboratory from 2003--2015, with an upgrade to the SuperCDMS experiment in 2012. The germanium detectors were operated at 50~mK and able to measure both the ionization and athermal phonons produced in a particle interaction. Measuring two signals enables discrimination between electron recoil and nuclear recoil events. An alternative operating mode for the detectors is called the CDMS low ionization threshold experiment (CDMSlite), where a higher bias was applied to the detectors and only the phonon signal analyzed. This method increased sensitivity to low-mass dark matter interactions, but sacrificed discrimination capability. The CDMSlite spectrum had a large contribution from electron recoil background events. From the information gained during the first two CDMSlite Runs, a background model was developed for the third and final CDMSlite Run. Analytical descriptions were identified for those backgrounds that were theoretically known, e.g. tritium $\beta$-spectrum, and Geant simulations were used to understand and predict the low-energy spectra from other sources, e.g. Compton scattering. Multiple new models were developed for detectors operated in CDMSlite at Soudan. These include the analytical formula for Compton scattering, and empirical models for surface backgrounds from $^{210}$Pb contamination of the germanium crystals and detector housing. In order to accurately describe the surface events, a new detector response function was developed that included information about the electric field and energy resolution of the detector. These models were essential to the implementation of a profile likelihood analysis of the CDMSlite Run 3 data, which improved on the sensitivity to dark matter over the Run 2 optimum interval analysis for WIMP masses above 2.5~GeV/$c^2$. This demonstrated a successful application of a likelihood analysis to the high-voltage operating mode, and the potential for these analyses in the future SuperCDMS SNOLAB experiment. For the SuperCDMS SNOLAB experiment, the change in background rates from radiogenic neutrons was considered as additional towers of detectors were added, and the feasibility of an active neutron veto as a potential upgrade for large payloads was studied. This veto could be constructed of plastic scintillator with layers of gadolinium resin, and would aid in reducing the nuclear recoil single scatter background that is indistinguishable from the WIMP signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next-generation Nuclear Physics with Forward Proton/Neutron Detection at MEIC

High-energy scattering processes on polarized light ions (deuterium, 3He) with detection of forward-moving spectator protons and neutrons offer unprecedented opportunities for precision studies of neutron structure and Quantum Chromodynamics in nuclei (nuclear binding, coherent fields). The JLab MEIC accelerator and integrated IR design provides unique capabilities for such measurements, especially with the polarized deuterium beam. We report about results of a JLab 2014 LDRD project aimed at simulating forward detection measurements under realistic conditions and quantifying the physics impact. This includes a short summary of the physics objectives, the results of process simulations, and a critical discussion of the essential beam and detector/IR requirements.

Weiss, Christian↗

Development of a Smart Signal Detection Method for Cyclic Voltammetry via Artificial Neural Intelligence

The electrorefiner (ER) is the heart of pyroprocessing technology which is a high-temperature method for separating uranium from Used Nuclear Fuel (UNF). It is important to improve this technology with respect to nuclear materials detection and accountability. Artificial Neural Intelligence (ANI) is a novel data analysis and simulation method that can be applied to electrochemical data sets. This computational code, which has been performed using the commercial software MATLAB, can be trained to generalize adequate electrical current and potential simulated data sets for the unseen data with a high accuracy of prediction. For this purpose, a massive collection of cyclic voltammetry (CV) data sets by Hoover (2014), for 0.5, 1, 2.5, and 5 wt% of zirconium chloride in LiCl-KCl molten salt with different scan rates at 773 K has been considered. The computer is trained via ANI to predict the unseen data after providing suitable hidden layers and validation numbers. In addition, this work can trace the CV plot for a blind condition by interpolating between two simulated data set. The different hidden layers with various neurons (from 5 to 30) at several validation numbers (from 5 to 30) has been studied and the average percent error between experimental and theoretical data for 0.5 wt% with 200 and 450 mV/s has been calculated. Preliminary results demonstrate that if the number of hidden layers increases from one to three, the average error falls down from 44% to around 8%. The best condition which gives a minimum average percent error has been discovered and the simulated CV graph has been compared with the experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Specialized diamond materials for NMR applications

Polarizable diamond materials and methods for obtaining nuclear magnetic resonance spectra of samples external to the diamond materials are described. The diamond materials can include 12C, 13C, substitutional nitrogen, and nitrogen vacancy defects in a crystalline lattice, wherein the substitutional nitrogen concentration is between 10 ppm and 200 ppm, the nitrogen vacancy concentration is between 10 ppb and 10 ppm, and the 13C concentration is greater than 1.1% and not more than 25%. Methods for obtaining nuclear magnetic resonance spectra can include optically pumping a diamond material to generate electron spin hyperpolarization in nitrogen vacancy centers, transferring the electron spin hyperpolarization to nuclei of the sample, and generating a nuclear magnetic resonance spectrum by applying a magnetic field to the sample, exciting the sample with a radio frequency pulse, and detecting a nuclear magnetic resonance response from the sample.

Parker, Alfred↗

Commissioning and field tests of a van-mounted system for the detection of radioactive sources and Special Nuclear Material

MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗