At least 487 records · Page 27

Ultrasonic Studies of Composites Undergoing Thermal and Fatigue Loading

New composite materials possess attractive properties for use in advanced aircraft. A necessary requirement for their introduction into aeronautic use is an accurate understanding of their long term aging processes so that proper design criteria can be established. In order to understand those properties, these composites must be exposed to thermal and load cycles that are characteristic of flight conditions. Additionally, airline companies will require nondestructive evaluation (NDE) methods that can be used in the field to assess the condition of these new materials as they age. As part of an effort to obtain the required information about new composites for aviation use, we are performing ultrasonic measurements both in the NDE laboratory and in the materials testing laboratory at NASA. The materials testing laboratory is equipped with environmental chambers mounted on load frames so that composite samples can be exposed to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This study reports on our initial ultrasonic attenuation results from thermoset and thermoplastic composite samples. Ultrasonic attenuation measurements have been used reliably to assess the effects of material degradation. For example, recently, researchers have shown that by using frequencies of ultrasound on the order of 24 MHz, they could obtain adequate contrast in the evaluation of thermal degradation in these composites. This paper will present data that shows results at a lower frequency range. In addition, we report results on the frequency dependence of attenuation as the slope of attenuation with respect to frequency, beta = delta alpha (f) / delta f. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This is a consequence of the assumption that interface correction terms are frequently independent. Uncertainty in those corrections terms compromises the value of conventional quantitative attenuation data.

Madaras, Eric I.↗

Capabilities and Limitations of Infrared Reflectance Microspectroscopy

Technological improvements in IR microspectroscopy have made it an increasingly appealing tool for planetary mineralogy. Microspectroscopy presents the prospect of examining small samples nondestructively and acquiring spectra that can be related to remote sensing observations. However, complications are introduced as a target beam size is reduced, and it is critical that limitations are understood. We present the results of a series of well constrained spectroscopic measurements, linking microspectroscopic data to traditionally collected reflectance spectra and petrologic information for the same rock.

Klima, R. L.↗

Pioneer Mars 1979 mission options

Two mission concepts utilizing modified Pioneer Venus hardware are presented as relatively low-cost alternatives for scientific exploration of Mars in 1979. Mission A would perform in situ aeronomy measurements in the Martian ionosphere and include several remote sensing instruments capable of geological surface mapping at low altitudes. The initial high eccentricity orbit would be allowed to decay in an adaptive mode. Mission B would sequentially deploy (from an orbiter bus), four, nondestructing surface penetrometers carrying instrumentation to investigate soil density, composition and chemistry, subsurface water, and perhaps seismology. Mission B is more expensive than mission A, since it requires more extensive hardware modifications and systems development.

Niehoff, J. C.↗

Nondestructive activation analysis of sample of lunar surface material returned by Luna 16 automatic station

The composition of a sample of lunar surface material returned by the Luna 16 automatic station from the Sea of Fertility was studied, using nondestructive activation analysis. The structure of the returned surface material is inhomogeneous; the surficial material is thin, quite homogeneous, and the granularity increases with depth. Based on grain size, the sample was separated into five zones. The activation analysis was conducted on a sample taken from the friable surficial layer, zone A. The content of Al, Mn, Na, Cr, Co, Fe, and Sc was determined by nondestructive activation analysis of the sample. In determining Cr, Co, Fe, and Sc, the sample was irradiated for 24 hours and cooled for 10 days. Gamma spectra of the samples were recorded with a semiconductor Ge(Li)-detector and a multichannel analyzer, and measurement data were processed with an electronic computer.

Chayko, M.↗

Development of a Neutron List Mode Collar (LMCL) and a List Mode Response Matrix Analysis Concept

This report was prepared for the Safeguards Program of the US Department of Energy’s (DOE’s) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The report presents the development of the neutron nondestructive assay system, the List Mode Collar (LMCL) for the project OR16-List Mode for Collar-PD1La “List Mode Response Matrix for Advanced Correlated Neutron Analysis for Nuclear Safeguards.” The new list mode electronics developed under this project, and a spatial analysis concept called the List Mode Response Matrix are also described in this report. Analysis algorithms based on classification methods are published in a separate report. This research addresses the need to expand the capabilities of current nondestructive assay systems used for nuclear safeguards applications and considers the sustainability of safeguards technologies by the development of a “retrofit” concept using electronics based on modern standards. Furthermore, employing list mode data acquisition enabled the development of a spatial analysis concept and empirical measurement of a spatial response not previously used for safeguards neutron counting applications or measured in a traditional neutron collar detector and, therefore, provides new capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for nondestructive testing

High voltage is applied to an arc gap adjacent to a test specimen to develop a succession of high frequency arc discharges. Those high frequency arc discharges generate pulses of ultrasonic energy within the test specimen without requiring the arc discharges to contact that test specimen and without requiring a coupling medium. Those pulses can be used for detection of flaws and measurements of certain properties and stresses within the test specimen.

Hoop, J. M.↗

Thermal Nondestructive Characterization of Corrosion in Boiler Tubes by Application fo a Moving Line Heat Source

Wall thinning in utility boiler waterwall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used lor inspection of these tubes. This technique has proved to be very labor intensive and slow. This has resulted in a "spot check" approach to inspections, making thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source, coupled with this analysis technique, represents a significant improvement in the inspection speed for large structures such as boiler waterwalls while still providing high-resolution thickness measurements. A theoretical basis for the technique will be presented thus demonstrating the quantitative nature of the technique. Further, results of laboratory experiments on flat Panel specimens with fabricated material loss regions will be presented.

Cramer, K. Elliott↗

Braze joint quality tested electromagnetically

Nondestructive electromagnetic method detects the extent of gold/nickel braze alloy flow in an engine injector sleeve-to-post joint. Voltage is induced in an inductor coil, along with a magnetically permeable material. The effects of altering the quantity of braze alloy present can then be measured.

Graves, D. B.↗

Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

Berning, D.↗

Infrared radiometric technique in temperature measurement

One class of commercially available imaging infrared radiometers using cooled detectors is sensitive to radiation over the 3 to 12 micron wavelength band. Spectral filters can tailor instrument sensitivity to specific regions where the target exhibits optimum radiance. The broadband spectral response coupled with real time two-dimensional imaging and emittance/background temperature corrections make the instruments useful for remote measurement of surface temperatures from -20 C to +1500 C. Commonly used radiometric techniques and assumptions are discussed, and performance specifications for a typical modern commercial instrument are presented. The potential usefulness of an imaging infrared radiometer in space laboratories is highlighted through examples of research, nondestructive evaluation, safety, and routine maintenance applications. Future improvements in instrument design and application of the radiometric technique are discussed.

Glazer, S.↗

Magnetic penetration depth of YBa2Cu3O(7-delta) thin films determined by the power transmission method

A power transmission measurement technique was used to determine the magnetic penetration depth (lambda) of YBa2Cu3O(7-delta) superconducting thin films on LaAlO3 within the 26.5 to 40.0 GHz frequency range, and at temperatures from 20 to 300 K. Values of lambda ranging from 1100 to 2500 A were obtained at low temperatures. The anisotropy of lambda was determined from measurements of c-axis and a-axis oriented films. An estimate of the intrinsic value of lambda of 90 +/- 30 nm was obtained from the dependence of lambda on film thickness. The advantage of this technique is that it allows lambda to be determined nondestructively.

Heinen, Vernon O.↗

Influence of Fiber Content, Thermal Cycles and Creep on Electrical Resistivity Measurements of SiCf/SiC Minicomposites

Fiber-reinforced Ceramic Matrix Composites (CMCs) are currently being used in high-temperature applications such as jet engine components. In such extreme environment applications, materials are exposed to many mechanical and thermal loading cycles during the life of the component. This exposure can degrade the component, and thus, components need to be monitored and inspected during service. The electrical resistivity nondestructive evaluation technique has been shown to be very sensitive to damage in CMCs, and although its performance is highly dependent on temperature, this temperature-dependence is still not well understood. Therefore, this current study aims to establish the influence of thermal cycles, creep, CVI-SiC matrix cracks and fiber volume fraction on the electrical resistance of Hi Nicalon and Hi-Nicalon Type S SiC fiber-reinforced minicomposites with BN interphases. Minicomposites with 97% CVI-SiC matrix volume fraction were used to characterize the electrical resistivity of the CVI-SiC matrix. Next, models were constructed to calculate fiber resistivity and onset and evolution of damage during tensile testing at room-temperature. The thermal cycles were achieved by heating as-received and precracked specimens to 1200°C and then cooling them to room temperature, with or without applied stress on fibers.

creep↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Microcomputed X-Ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.

36 MATERIALS SCIENCE↗

Enhanced resonant ultrasound spectroscopy for measurement of the elastic properties of multi-material systems

Understanding the elastic properties of materials is critical for their safe incorporation and predictable performance. Current methods of bulk elastic characterization often have notable limitations for in situ structural applications, with usage restricted to simple geometries and material distributions. To address these existing issues, this study sought to expand the capabilities of resonant ultrasound spectroscopy (RUS), an established nondestructive evaluation method, to include the characterization of isotropic multi-material samples. In this work, finite-element-based RUS analysis consisted of numerical simulations and experimental testing of composite samples comprised of material pairs with varying elasticity and density contrasts. Utilizing genetic algorithm inversion and mode matching, our results demonstrate that elastic properties of multi-material samples can be reliably identified within several percent of known or nominal values using a minimum number of identified resonance modes, given sample mass is held consistent. The accurate recovery of material properties for composite samples of varying material similarity and geometry expands the pool of viable samples for RUS and advances the method towards in situ inspection and evaluation.

36 MATERIALS SCIENCE↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infrared Contrast Analysis Technique for Flash Thermography Nondestructive Evaluation

The paper deals with the infrared flash thermography inspection to detect and analyze delamination-like anomalies in nonmetallic materials. It provides information on an IR Contrast technique that involves extracting normalized contrast verses time evolutions from the flash thermography infrared video data. The paper provides the analytical model used in the simulation of infrared image contrast. The contrast evolution simulation is achieved through calibration on measured contrast evolutions from many flat bottom holes in the subject material. The paper also provides formulas to calculate values of the thermal measurement features from the measured contrast evolution curve. Many thermal measurement features of the contrast evolution that relate to the anomaly characteristics are calculated. The measurement features and the contrast simulation are used to evaluate flash thermography inspection data in order to characterize the delamination-like anomalies. In addition, the contrast evolution prediction is matched to the measured anomaly contrast evolution to provide an assessment of the anomaly depth and width in terms of depth and diameter of the corresponding equivalent flat-bottom hole (EFBH) or equivalent uniform gap (EUG). The paper provides anomaly edge detection technique called the half-max technique which is also used to estimate width of an indication. The EFBH/EUG and half-max width estimations are used to assess anomaly size. The paper also provides some information on the "IR Contrast" software application, half-max technique and IR Contrast feature imaging application, which are based on models provided in this paper.

Koshti, Ajay↗