Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Quark and lepton mixing as manifestations of violated mirror symmetry

The existence of heavy mirror analogs of ordinary fermions would provide deeper insight into the gedanken paradox appearing in the Standard Model upon direct parity violation and consisting in a physical distinguishability of left- and right-hand coordinate frames. Arguments are presented in support of the statement that such mirror states may also be involved in the formation of observed properties of the system of Standard Model quarks and leptons—that is, their mass spectra and their weak-mixing matrices: (i) In the case of the involvement of mirror generations, the quark mixing matrix assumes the experimentally observed form. It is determined by the constraints imposed by weak SU(2) symmetry and by the quark-mass hierarchy. (ii) Under the same conditions and upon the involvement of mirror particles, the lepton mixing matrix (neutrino mixing) may become drastically different from its quark analog—the Cabibbo-Kobayashi-Maskawa matrix; that is, it may acquire properties suggested by experimental data. This character of mixing is also indicative of an inverse mass spectrum of Standard Model neutrinos and their Dirac (not Majorana) nature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and calibration of mirrors and gratings for the Soft X-ray materials science beamline at the Linac Coherent Light Source free-electron laser

This article discusses the development and calibration of the x-ray reflective and diffractive elements for the Soft X-ray Materials Science (SXR) beamline of the Linac Coherent Light Source (LCLS) free-electron laser (FEL), designed for operation in the 500 – 2000 eV region. The surface topography of three Si mirror substrates and two Si diffraction grating substrates was examined by atomic force microscopy (AFM) and optical profilometry. The figure of the mirror substrates was also verified via surface slope measurements with a long trace profiler. A boron carbide (B 4 C) coating especially optimized for the LCLS FEL conditions was deposited on all SXR mirrors and gratings. Coating thickness uniformity of 0.14 nm root mean square (rms) across clear apertures extending to 205 mm length was demonstrated for all elements, as required to preserve the coherent wavefront of the LCLS source. The reflective performance of the mirrors and the diffraction efficiency of the gratings were calibrated at beamline 6.3.2 at the Advanced Light Source synchrotron. To verify the integrity of the nanometer-scale grating structure, the grating topography was examined by AFM before and after coating. This is to our knowledge the first time B 4 C-coated diffraction gratings are demonstrated for operation in the soft x-ray region.

36 MATERIALS SCIENCE↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Room temperature plasma-etching and surface passivation of far-ultraviolet Al mirrors using electron beam generated plasmas

The development of optical systems operating in the far ultraviolet range (FUV, λ=100-200 nm) is limited by the efficiency of passivated aluminum (Al) mirrors. Although it is presently possible to obtain high-reflectivity FUV mirrors through physical vapor deposition, the process involves deposition with substrates at high temperatures, which is technically challenging for large optical elements. A novel passivation procedure for bare Al mirrors is reported. The treatment consisted of using a low-temperature electron-beam generated plasma produced in a gas mixture of Ar and SF6 to etch away the native oxide layer from the Al film, while simultaneously promoting the generation of a thin aluminum tri-fluoride (AlF3) layer on the Al surface. In the first section we analyze the effect of varying both ion energy and SF6 concentration on the FUV reflectance, thickness, composition, and surface morphology of the resulting AlF3 protective layers. In the second section, the reflectivity of samples is optimized at selected important FUV wavelengths for astronomical observations. Notably, samples attained state-of-the-art reflectances of 75% at 108.5 nm (He Lyman γ), 91% at 121.6 nm (H Lyman α), 90% at 130.4 nm (OI), and of 95% at 155.0 nm (C IV). The stability over time of these passivated mirrors is also investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3d N=4 Bootstrap and Mirror Symmetry

We investigate the non-BPS realm of 3d {N} = 4 N = 4 superconformal field theory by uniting the non-perturbative methods of the conformal bootstrap and supersymmetric localization, and utilizing special features of 3d {N} = 4 N = 4 theories such as mirror symmetry and a protected sector described by topological quantum mechanics (TQM). Supersymmetric localization allows for the exact determination of the conformal and flavor central charges, and the latter can be fed into the mini-bootstrap of the TQM to solve for a subset of the OPE data. We examine the implications of the Z_2 Z 2 mirror action for the SCFT single- and mixed-branch crossing equations for the moment map operators, and apply numerical bootstrap to obtain universal constraints on OPE data for given flavor symmetry groups. A key ingredient in applying the bootstrap analysis is the determination of the mixed-branch superconformal blocks. Among other results, we show that the simplest known self-mirror theory with SU(2) \times SU(2) S U ( 2 ) × S U ( 2 ) flavor symmetry saturates our bootstrap bounds, which allows us to extract the non-BPS data and examine the self-mirror Z_2 Z 2 symmetry thereof.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mirror monochromator

In this SBIR project, Electron Optica, Inc. (EOI) is developing a mirror electron monochromator (MirrorChrom) attachment to new and retrofitted electron microscopes (EMs) for improving the energy resolution of the EM from the characteristic range of 0.2-0.5 eV to the range of 10-50 meV. This improvement will enhance the characterization of materials by imaging and spectroscopy. In particular, the monochromator will refine the energy spectra characterizing materials, as obtained from transmission EMs [TEMs] fitted with electron spectrometers, and it will increase the spatial resolution of the images of materials taken with scanning EMs (SEMs) operated at low voltages. EOI’s MirrorChrom technology utilizes a magnetic prism to simultaneously deflect the electron beam off the axis of the microscope column by 90° and disperse the electrons in proportional to their energies into a module with an electron mirror and a knife-edge. The knife-edge cuts off the tails of the energy distribution to reduce the energy spread of the electrons that are reflected, and subsequently deflected, back into the microscope column. The knife-edge is less prone to contamination, and thereby charging, than the conventional slits used in existing monochromators, which improves the reliability and stability of the module. The overall design of the MirrorChrom exploits the symmetry inherent in reversing the electron trajectory in order to maintain the beam brightness – a parameter that impacts how well the electron beam can be focused downstream onto a sample. During phase I, EOI drafted a set of candidate monochromator architectures and evaluated the trade-offs between energy resolution and beam current to achieve the optimum design for three particular applications with market potential: increasing the spatial resolution of low voltage SEMs, increasing the energy resolution of low voltage TEMs (beam energy of 5-20 keV), and increasing the energy resolution of conventional TEMs (beam energy of 80-120 keV). Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key monochromator components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete monochromator. The simulations reveal that the mirror monochromator can reduce the energy spread of a Schottky electron source, an established electron emitter used widely in EMs, to 10 meV for practical beam current values and that further reduction of the energy spread down to 3 meV is possible for low current applications with a Cold Field Emitter (an electron source with 10x the brightness of a Schottky source). MirrorChroms can be designed and built to attach to different types of TEMs and SEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at the nanoscale to advance material science research in the field of nanotechnology as well as biomedical research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation and assessment of debris on NIF transport mirrors

The purpose of this report is to document the quantity and nature of debris found on the surface of NIF transport mirrors during initial system operations in calendar years 2009 and early 2010. Observations were made of LM5s equipped with viewing windows, returned LM8s, and a few returned LM7s. In all cases the mirror surfaces were illuminated with grazing-angle bright light so as to highlight debris. For the LM5s this illumination was provided by bar lights that are permanently attached to the mirror line replaceable units (LRUs) and are used in-situ. For all other surfaces, illumination was provided by a hand-held “bright-light” 75,000 candlepower flashlight. The number of debris items on mirror surfaces were determined by counting items individually or, if they were too numerous to count over the entire surface, by determining an approximate representative number density (number per area) from which a total debris count could be estimated. Approximate sizes of debris items were most often estimated visually, but occasionally particles were removed from the surface by picking or wiping and subsequently analyzed in an optical or scanning electron microscope. Particles from enclosures were collected by swiping the surface as for the verification of cleanliness. The swipe paper provides a convenient substrate for the subsequent examination and analysis of the particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The St. Benedict Facility: Probing Fundamental Symmetries through Mixed Mirror $β$-Decays

Precise measurements of nuclear beta decays provide a unique insight into the Standard Model due to their connection to the electroweak interaction. These decays help constrain the unitarity or non-unitarity of the Cabibbo–Kobayashi–Maskawa (CKM) quark mixing matrix, and can uniquely probe the existence of exotic scalar or tensor currents. Of these decays, superallowed mixed mirror transitions have been the least well-studied, in part due to the absence of data on their Fermi to Gamow-Teller mixing ratios ($ρ$). At the Nuclear Science Laboratory (NSL) at the University of Notre Dame, the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is being constructed to determine the ρ for various mirror decays via a measurement of the beta–neutrino angular correlation parameter ($α_{βν}$) to a relative precision of 0.5%. In this work, we present an overview of the St. Benedict facility and the impact it will have on various Beyond the Standard Model studies, including an expanded sensitivity study of $ρ$ for various mirror nuclei accessible to the facility. A feasibility evaluation is also presented that indicates the measurement goals for many mirror nuclei, which are currently attainable in a week of radioactive beam delivery at the NSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward Interpreting the IBEX Ribbon with Mirror Diffusion in Interstellar Turbulent Magnetic Fields

We investigate the role of the magnetohydrodynamic (MHD) turbulence measured by Voyager in the very local interstellar medium (VLISM) in modeling the Interstellar Boundary Explorer ribbon. We demonstrate that the mirroring by compressible modes of MHD turbulence dominates over that by the mean magnetic field. Based on the new mirror diffusion mechanism identified by Lazarian & Xu for particles with large pitch angles in MHD turbulence, we find that the mirror diffusion can both confine pickup ions and preserve their initial pitch angles, and thus it accounts for the enhanced intensity of energetic neutral atoms that return to the heliosphere. The ribbon width is determined by both the range of pitch angles for effective turbulent mirroring and the field line wandering induced by Alfvénic modes. It in turn provides a constraint on the amplitude of magnetic fluctuations of fast modes. The field line wandering also affects the coherence of the ribbon structure across the sky. By extrapolating the magnetic energy spectrum measured by Voyager, we find that the injection scale of the turbulence in the VLISM must be less than ~500 au for the ribbon structure to be coherent.

79 ASTRONOMY AND ASTROPHYSICS↗

Mount enables precision adjustment of optical-instrumentation mirror

Mirror mount assembly allows the plane of a mirror to be adjusted through small angles about two orthogonal axes. The assembly, which has a mirror mount with two independently adjustable flexure joints, allows independent precise adjustment of the mirror mount with respect to each axis.

Source record↗

Thermal correction of deformations in a telescope mirror

Orbiting astronomical observatories have the potential for making observations far superior to those from earth-based mirrors. In order for this performance to be realized, the contour of the primary mirror must be very accurately controlled. A preliminary investigation of the use of thermally induced elastic strains for correcting axisymmetric deformations in space telescope mirrors has been presented. The relation between axial deformation and thermal inputs was determined by a finite difference solution of the equations for thin elastic shells. The use of this technique was demonstrated analytically on a beryllium paraboloid. This mirror had 10 equally spaced thermal inputs and results are presented which show the nature of the temperature distribution required to correct deformations due to an acceleration-type loading.

Rhodes, M. D.↗

Research study to determine critical optical/mechanical properties of materials considered for selection as substrates for the primary mirror on a large telescope

An investigation was conducted to evaluate the stability of a specific low expansion glass-ceramic material relative to its use as a large, lightweight mirror substrate for diffraction-limited spaceborne optical applications. These evaluations were made on a segment (0.44 meter diameter by 0.31 meter thick) of a 2 to 3 meter diameter mirror blank. The dimensional stability of this mirror was measured interferometrically before and after lightweighting, as a function of rough machining, etching, thermal environment, and support configuration. A special computer analysis program was used to plot the coefficients corresponding to aberrations with sixfold symmetry (caused by the mirror's self-weight deflection on a three point support). The objective was to enhance the test sensitivity. Results indicate that any such effects due to self-weight deflection are of the order of 0.015 lambda rms. The rms and peak-to-peak figure changes associated with each processing operation are summarized.

Slomba, A. F.↗

Effects of surface polishing on the microstrain behavior of telescope mirror materials

Rough ground silicic mirror substrate materials were found in previous investigations to exhibit significant surface yield. This effect was removed by surface etching, a procedure not normally employed in the finishing of optical telescope mirrors. The effects of fine grinding and polishing techniques as well as graded etching are investigated. Torsional shear measurements of yield strain versus stress are made on four candidate mirror substrate materials: polycrystalline silicon, ULE silica 7971, CER-VIT 101, and fused silica 7940. Commonly employed fine grinding and polishing practices are shown to remove a major portion of the surface yield found in rough ground mirror substrate materials.

Eul, W. A.↗

Scanning mirror for infrared sensors

A high resolution, long life angle-encoded scanning mirror, built for application in an infrared attitude sensor, is described. The mirror uses a Moire' fringe type optical encoder and unique torsion bar suspension together with a magnetic drive to meet stringent operational and environmental requirements at a minimum weight and with minimum power consumption. Details of the specifications, design, and construction are presented with an analysis of the mirror suspension that allows accurate prediction of performance. The emphasis is on mechanical design considerations, and brief discussions are included on the encoder and magnetic drive to provide a complete view of the mirror system and its capabilities.

Anderson, R. H.↗

Evaluation of control laws and actuator locations for control systems applicable to deformable astronomical telescope mirrors

Some of the major difficulties associated with large orbiting astronomical telescopes are the cost of manufacturing the primary mirror to precise tolerances and the maintaining of diffraction-limited tolerances while in orbit. One successfully demonstrated approach for minimizing these problem areas is the technique of actively deforming the primary mirror by applying discrete forces to the rear of the mirror. A modal control technique, as applied to active optics, has previously been developed and analyzed. The modal control technique represents the plant to be controlled in terms of its eigenvalues and eigenfunctions which are estimated via numerical approximation techniques. The report includes an extension of previous work using the modal control technique and also describes an optimal feedback controller. The equations for both control laws are developed in state-space differential form and include such considerations as stability, controllability, and observability. These equations are general and allow the incorporation of various mode-analyzer designs; two design approaches are presented. The report also includes a technique for placing actuator and sensor locations at points on the mirror based upon the flexibility matrix of the uncontrolled or unobserved modes of the structure. The locations selected by this technique are used in the computer runs which are described. The results are based upon three different initial error distributions, two mode-analyzer designs, and both the modal and optimal control laws.

Ostroff, A. J.↗

Method and apparatus for optically monitoring the angular position of a rotating mirror

An optical system monitors the angular position of a rotating scanning mirror to indicate the effective start and end of each scan. At a certain angular position, a ray of energy transmitted to the mirror is reflected a plurality of times between the reflectors associated with the optical system and the line on the mirror parallel to the axis, and then to a detector to sense that angular position. A single optical system may be arranged to sense a plurality of different angular positions for each revolution of the mirror.

Lansing, J. C., Jr.↗

Solar simulator mirror refurbishment

Solar simulator mirrors were refurbished. Two different refurbishment methods were employed. In the first, the electroformed mirror replica was removed from the casting and replaced with a new mirror replica. In the second, only the aluminized surface, with its protective overcoat, was removed from the mirror and replaced after cleaning of the nickel surface.

Leverton, W. R.↗

Solar absorptance of second surface mirrors for high angles of incidence

Recent measurements have indicated an increase rather than a decrease in the solar absorptivity of second surface mirrors at angles of incidence greater than 80 deg. These observations stimulated an analytical effort which revealed that the increase does occur. Using electromagnetic wave theory, the solar absorptance equations for the mirror configurations commonly encountered in application are developed. An increase in mirror solar absorptance has also been deduced from the temperatures of a second surface mirrored radiator being monitored on the Nimbus E microwave spectrometer experiment. Test and calculated results substantiating the solar absorptance increase are presented.

Stultz, J. W.↗