Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micromachining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Aligned Carbon Nanotube Tape for Sensor Applications

For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical properties CNT tape as a strain gauge in Structural Health Monitoring will provide an excellent material to embed within composite structures

Tucker, Dennis S.↗

Proposed US Contributions to LOFT

Proposed US Enhancements include:Tantalum X -ray collimator, Additional ground station, Large Observatory for X-Ray Timing (LOFT) instrument team participation, US science support center & data archive, and Science enabled by US hardware. High-Z material with excellent stopping power. Fabricated using a combination of laser micromachining and chemical etching. Known technology capable of producing high-aspect ratio holes and large open fractions. Reduces LOFT LAD background by a factor of 3. Telemetry formats for LOFT based upon RXTE/EDS experience. Ground system software and strategies for WFM based upon RXTE/ASM automated pipeline software. MSFC engineering trade studies supporting the Ta collimator. Burst alert triggers based upon Fermi/GBM and HETE-2. Science Enhancements Enabled by US Hardware include: Tantalum collimator: Reduces background by factor of 3. Improves sensitivity to faint sources such as AGN. Eliminates contamination by bright/variable sources. outside the LAD field of view. US Ground Station: Enables continuous telemetry of all events from the WFM. Allows LAD to observe very bright >500 mCrab sources with full event resolution.

Wilson-Hodge, Colleen↗

Large-aperture Wide-bandwidth Antireflection-coated Silicon Lenses for Millimeter Wavelengths

The increasing scale of cryogenic detector arrays for submillimeter and millimeter wavelength astrophysics has led to the need for large aperture, high index of refraction, low loss, cryogenic refracting optics. Silicon with n 3.4, low loss, and high thermal conductivity is a nearly optimal material for these purposes but requires an antireflection (AR) coating with broad bandwidth, low loss, low reflectance, and a matched coefficient of thermal expansion. We present an AR coating for curved silicon optics comprised of subwavelength features cut into the lens surface with a custom three-axis silicon dicing saw. These features constitute a metamaterial that behaves as a simple dielectric coating.We have fabricated silicon lenses as large as 33.4 cm in diameter with micromachined layers optimized for use between 125 and 165 GHz. Our design reduces average reflections to a few tenths of a percent for angles of incidence up to 30deg with low cross polarization.We describe the design, tolerance, manufacture, and measurements of these coatings and present measurements of the optical properties of silicon at millimeter wavelengths at cryogenic and room temperatures. This coating and lens fabrication approach is applicable from centimeter to submillimeter wavelengths and can be used to fabricate coatings with greater than octave bandwidth.

thermal expansion↗

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

Spinoff 2015

Topics covered include: 3D Endoscope to Boost Safety, Cut Cost of Surgery; Audio App Brings a Better Night's Sleep Liquid Cooling Technology Increases Exercise Efficiency; Algae-Derived Dietary Ingredients Nourish Animals; Space Grant Research Launches Rehabilitation Chair; Vision Trainer Teaches Focusing Techniques at Home; Aircraft Geared Architecture Reduces Fuel Cost and Noise; Ubiquitous Supercritical Wing Design Cuts Billions in Fuel Costs; Flight Controller Software Protects Lightweight Flexible Aircraft; Cabin Pressure Monitors Notify Pilots to Save Lives; Ionospheric Mapping Software Ensures Accuracy of Pilots' GPS; Water Mapping Technology Rebuilds Lives in Arid Regions; Shock Absorbers Save Structures and Lives during Earthquakes; Software Facilitates Sharing of Water Quality Data Worldwide; Underwater Adhesives Retrofit Pipelines with Advanced Sensors; Laser Imaging Video Camera Sees through Fire, Fog, Smoke; 3D Lasers Increase Efficiency, Safety of Moving Machines; Air Revitalization System Enables Excursions to the Stratosphere; Magnetic Fluids Deliver Better Speaker Sound Quality; Bioreactor Yields Extracts for Skin Cream; Private Astronaut Training Prepares Commercial Crews of Tomorrow; Activity Monitors Help Users Get Optimum Sun Exposure; LEDs Illuminate Bulbs for Better Sleep, Wake Cycles; Charged Particles Kill Pathogens and Round Up Dust; Balance Devices Train Golfers for a Consistent Swing; Landsat Imagery Enables Global Studies of Surface Trends; Ruggedized Spectrometers Are Built for Tough Jobs; Gas Conversion Systems Reclaim Fuel for Industry; Remote Sensing Technologies Mitigate Drought; Satellite Data Inform Forecasts of Crop Growth; Probes Measure Gases for Environmental Research; Cloud Computing Technologies Facilitate Earth Research; Software Cuts Homebuilding Costs, Increases Energy Efficiency; Portable Planetariums Teach Science; Schedule Analysis Software Saves Time for Project Planners; Sound Modeling Simplifies Vehicle Noise Management; Custom 3D Printers Revolutionize Space Supply Chain; Improved Calibration Shows Images' True Colors; Micromachined Parts Advance Medicine, Astrophysics, and More; Metalworking Techniques Unlock a Unique Alloy; Low-Cost Sensors Deliver Nanometer-Accurate Measurements; Electrical Monitoring Devices Save on Time and Cost; Dry Lubricant Smooths the Way for Space Travel, Industry; and Compact Vapor Chamber Cools Critical Components.

Source record↗

Ultra-Sensitive Transition-Edge Sensors (TESs) for Far-IR/Submm Space-Borne Spectroscopy

We have built surface micromachined thin-film metallized Si(x)N(y) optical absorbers for transition-edge sensors (TESs) suitable for the Background - Limited far-IR/Submm Spectrograph (BLISS). BLISS is a broadband (38 micrometers - 433 micrometers), grating spectrometer consisting of five wavebands each with a modest resolution of R (is) approx. 1000. Because BLISS requires the effective noise equivalent power (NEP) of the TES to be below 10 (exp 19) W/Hz(exp 1/2), our TESs consist of four long (1000 micrometers), narrow (0.4 micrometers ), and thin (0.25 micrometers ) Si(x) N(y) support beams that reduce the thermal conductance G between the substrate and the optical absorber. To reduce the heat capacity of the absorber and make the response time tau fast enough for BLISS, our absorbers are patterned into a mesh geometry with a fill factor of less than 10%. We use a bilayer of Ti/Au to make the effective impedance of the absorber match the impedance of the incoming radiation for each band. Measurements of the response time of the metallized absorbers to heat pulses show that their heat capacity exceeds the predictions of the Debye model. Our results are suggestive that the surface of the low pressure chemical vapor deposition (LPCVD) Si(x)N(y) used in the absorbers' construction is the source of microstates that dominate the heat capacity.

far-IR spectrometer↗

Shear Stress Sensing using Elastomer Micropillar Arrays

The measurement of shear stress developed as a fluid moves around a solid body is difficult to measure. Stresses at the fluid-solid interface are very small and the nature of the fluid flow is easily disturbed by introducing sensor components to the interface. To address these challenges, an array of direct and indirect techniques have been investigated with various advantages and challenges. Hot wire sensors and other indirect sensors all protrude significantly into the fluid flow. Microelectromechanical systems (MEMS) devices, although facilitating very accurate measurements, are not durable, are prone to contamination, and are difficult to implement into existing model geometries. One promising approach is the use of engineered surfaces that interact with fluid flow in a detectable manner. To this end, standard lithographic techniques have been utilized to generate elastomeric micropillar arrays of various lengths and diameters. Micropillars of controlled length and width were generated in polydimethylsiloxane (PDMS) elastomer using a soft-lithography technique. The 3D mold for micropillar replication was fabricated using laser ablative micromachining and contact lithography. Micropillar dimensions and mechanical properties were characterized and compared to shear sensing requirements. The results of this characterization as well as shear stress detection techniques will be discussed.

Wohl, Christopher J.↗

Multimode Bolometer Development for the Primordial Inflation Explorer (PIXIE) Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background [1]. In this work, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a tensioning scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE↗

Multimode Bolometer Development for the PIXIE Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With approximately 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE↗

Micromechanical Devices for Control of Cell-Cell Interaction, and Methods of Use Thereof

The development and function of living tissues depends largely on interactions between cells that can vary in both time and space; however, temporal control of cell-cell interaction is experimentally challenging. By employing a micromachined silicon substrate with moving parts, herein is disclosed the dynamic regulation of cell-cell interactions via direct manipulation of adherent cells with micron-scale precision. The inventive devices and methods allow mechanical control of both tissue composition and spatial organization. The inventive device and methods enable the investigation of dynamic cell-cell interaction in a multitude of applications, such as intercellular communication, spanning embryogenesis, homeostasis, and pathogenic processes.

Bhatia, Sangeeta N.↗

Diagnostic Techniques to Elucidate the Aerodynamic Performance of Acoustic Liners

In support of Topic A.2.8 of NASA NRA NNH10ZEA001N, the University of Florida (UF) has investigated the use of flow field optical diagnostic and micromachined sensor-based techniques for assessing the wall shear stress on an acoustic liner. Stereoscopic particle image velocimetry (sPIV) was used to study the velocity field over a liner in the Grazing Flow Impedance Duct (GFID). The results indicate that the use of a control volume based method to determine the wall shear stress is prone to significant error. The skin friction over the liner as measured using velocity curve fitting techniques was shown to be locally reduced behind an orifice, relative to the hard wall case in a streamwise plane centered on the orifice. The capacitive wall shear stress sensor exhibited a linear response for a range of shear stresses over a hard wall. PIV over the liner is consistent with lifting of the near wall turbulent structure as it passes over an orifice, followed by a region of low wall shear stress.

June, Jason↗

Ion Chromatography-on-a-chip for Water Quality Analysis

We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

Kidd, R. D.↗

Far-Infrared Room-Temperature Focal Plane Modules for Radiation Budget Instrument

This work presents focal plane modules for a Radiation Budget Instrument, a passive remote-sensing instrument that follows the legacy of the Clouds and Earth’s Radiant Energy System (CERES) to measure short and longwave Earth’s radiation budget. The focal plane arrays are micromachined at JPL (Jet Propulsion Laboratory) and integrated into sub-assembly modules to be mounted on the optical telescope of the instrument.

Mariani, Giacomo↗

Small Inertial Measurement Units- Sources of Error and Limitations on Accuracy

Inertial measurement units (IMUs) with very low mass and power can be manufactured using micromachined accelerometers and gyroscopes. Six degree of freedom packages which require a few watts of power and have less than a kg of mass are available commercially, greatly expanding the potential applications of IMUs in guidance and navigation. Recent advances in small sensor design and fabrication have pushed the performance limits of these small devices. However, the limitations on the precision of small IMUs are not entirely due to the performance of the individual sensors.

Hoenk, Michael E.↗