Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid argon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Graph Neural Network for Object Reconstruction in Liquid Argon Time Projection Chambers

The Exa.TrkX project presents a graph neural network (GNN) technique for low-level reconstruction of neutrino interactions in a Liquid Argon Time Projection Chamber (LArTPC). GNNs are still a relatively novel technique, and have shown great promise for similar reconstruction tasks in the Large Hadron Collider (LHC). Graphs describing particle interactions are formed by treating each detector hit as a node, with edges describing the relationships between hits. We utilise a multi-head attention message passing network which performs graph convolutions in order to label each node with a particle type.We present an updated variant of our GNN architecture, with several improvements. After testing the model on more realistic simulation with regions of unresponsive wires, the target was modified from edge classification to node classification in order to increase robustness. Removing edges as a classification target opens up a broader possibility space for edge-forming techniques; we explore the model’s performance across a variety of approaches, such as Delaunay triangulation, kNN, and radius-based methods. We also extend this model to the 3D context, sharing information between detector views. By using reconstructed 3D spacepoints to map detector hits from each wire plane, the model naively constructs 2D representations that are independent yet fully consistent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCQE-like $\nu_{e}$ Selection in SBND using Convolutional Visual Network

Neutrinos from the Booster Neutrino Beam (BNB) at Fermilab interact with argon in a Liquid Argon Time Projection Chamber (LArTPC) differently based on their flavour. By examining the particles produced in a charged-current interaction, both the interaction type and the neutrino flavour can be inferred. The Short Baseline Near Detector has the largest neutrino-argon cross section data to date, motivating in-depth studies of various cross-section channels and topologies. This project aims to select electron neutrino quasi-elastic-like (QE-like) interactions in SBND using Convolutional Visual Network (CVN) scores. The CVN is a neural network that processes visual information from an event and assigns scores corresponding to its likelihood of being each interaction type. An inclusive study of electron neutrino charged current interactions using CVN has already been conducted. This analysis aims to build on this study, further utilizing CVN scores to isolate electron neutrino QE-like interactions characterized by the presence of an electron and one or more protons ($N > 0$) in the final state. The project s goal is to contribute to the overall cross-section measurement efforts within the SBN program at Fermilab.

Breen, Genevieve [Mt. Holyoke Coll.]↗

Neutron-Antineutron Transition Search at DUNE

Neutron-antineutron transition is a baryon number violating process with ΔB=2, providing a unique insight into potential explanations of the baryon asymmetry in our universe, especially in the context of post-sphaleron baryogenesis. Studies have been conducted across various neutron-rich environments, including free neutron sources, neutron stars, and bound neutrons in large underground neutrino detectors, among which large neutrino experiments have historically obtained the most stringent constraints. The forthcoming Deep Underground Neutrino Experiment (DUNE) will offer especially strong prospects for this search, enabled by the high spatial resolution of its liquid argon time projection chamber. This poster presents a recent study on neutron-antineutron transition at DUNE using machine-learning based event classification.

Yu, Kaiwen [UC, Irvine (main)]↗

Search for light sterile neutrinos with two neutrino beams at MicroBooNE

The existence of three distinct neutrino flavours, ν e , ν μ and ν τ , is a central tenet of the Standard Model of particle physics. Quantum-mechanical interference can allow a neutrino of one initial flavour to be detected sometime later as a different flavour, a process called neutrino oscillation. Several anomalous observations inconsistent with this three-flavour picture have motivated the hypothesis that an additional neutrino state exists, which does not interact directly with matter, termed as ‘sterile’ neutrino, ν s . This includes anomalous observations from the Liquid Scintillator Neutrino Detector (LSND)3 experiment and Mini-Booster Neutrino Experiment (MiniBooNE), consistent with ν μ → ν e transitions at a distance inconsistent with the three-neutrino picture. Here we use data obtained from the MicroBooNE liquid-argon time projection chamber in two accelerator neutrino beams to exclude the single light sterile neutrino interpretation of the LSND and MiniBooNE anomalies at the 95% confidence level (CL). Moreover, we rule out a notable portion of the parameter space that could explain the gallium anomaly. This is one of the first measurements to use two accelerator neutrino beams to break a degeneracy between ν e appearance and disappearance, which would otherwise weaken the sensitivity to the sterile neutrino hypothesis. We find no evidence for either ν μ → ν e flavour transitions or ν e disappearance that would indicate non-standard flavour oscillations. Our results indicate that previous anomalous observations consistent with ν μ → ν e transitions cannot be explained by introducing a single sterile neutrino state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of calorimetric measurement in a liquid argon time projection chamber

The liquid argon time projection chamber provides high-resolution event images and excellent calorimetric resolution for studying neutrino physics and searching for beyond-standard-model physics. In this article, we review the main physics processes that affect detector response, including the electronics and field responses, space charge effects, electron attachment to impurities, diffusion, and recombination. We describe methods to measure those effects, which are used to calibrate the detector response and convert the measured raw analog-to-digital converter (ADC) counts into the original energy deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform resampling with LMN method

In this article, resampling is a common technique applied in digital signal processing. Based on the Fast Fourier Transformation (FFT), we apply an optimization called here the LMN method to achieve fast and robust re-sampling. In addition to performance comparisons with some other popular methods, we illustrate the effectiveness of this LMN method in a particle physics experiment: re-sampling of waveforms from Liquid Argon Time Projection Chambers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

Searching for Sterile Neutrinos Using an Exclusive 1$\mu$;1$\rho$ Selection: The Short Baseline Near Detector (SBND)

Over the last two decades, we have seen several of short-baseline neutrino oscillation experiments report results which challenged mainstream theories of neutrino oscillations. On the forefront of exploring these anomalies further is Fermilab's Short-Baseline Neutrino (SBN) program, which consists of two large liquid argon time projection chambers (LArTPCs), SBND and ICARUS, placed in alignment with the Booster Neutrino Beam (BNB). I'll be showing the strength that a 1mu1p selection at the SBN program can have for delivering world-leading sensitivity to distortions in the muon neutrino spectrum due to sterile neutrino oscillations.

Rowe, Nathaniel [Chicago U.]↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The continuous readout stream of the MicroBooNE liquid argon time projection chamber for detection of supernova burst neutrinos

The MicroBooNE continuous readout stream is a parallel readout of the MicroBooNE liquid argon time projection chamber (LArTPC) which enables detection of non-beam events such as those from a supernova neutrino burst. The low energies of the supernova neutrinos and the intense cosmic-ray background flux due to the near-surface detector location makes triggering on these events very challenging. Instead, MicroBooNE relies on a delayed trigger generated by SNEWS (the Supernova Early Warning System) for detecting supernova neutrinos. The continuous readout of the LArTPC generates large data volumes, and requires the use of real-time compression algorithms (zero suppression and Huffman compression) implemented in an FPGA (field-programmable gate array) in the readout electronics. In this paper we present the results of the optimization of the data reduction algorithms, and their operational performance. To demonstrate the capability of the continuous stream to detect low-energy electrons, a sample of Michel electrons from stopping cosmic-ray muons is reconstructed and compared to a similar sample from the lossless triggered readout stream.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decaying sterile neutrinos at short baselines

Long-standing anomalous experimental results from short-baseline neutrino experiments have persisted for decades. These results, when interpreted with one or more light sterile neutrinos, are inconsistent with numerous null results experimentally. However, if the sterile neutrino decays en route to the detector, this can mimic ν μ → ν e oscillation signals while avoiding many of these external constraints. We revisit this solution to the MiniBooNE and LSND puzzles in view of new data from the MicroBooNE experiment at Fermilab. Using MicroBooNE’s liquid-argon time-projection chamber search for an excess of ν e in the Booster beam, we derive new limits in two models’ parameter spaces of interest; where the sterile neutrino decays (I) via mixing with the active neutrinos, or (II) via higher-dimensional operators. We also provide an updated, comprehensive fit to the MiniBooNE neutrino- and antineutrino-beam data, including appearance ( ν e ) and disappearance ( ν μ ) channels. Despite alleviating the tension with muon neutrino disappearance experiments, we find that the latest MicroBooNE analysis rules out the decaying sterile neutrino solution in a large portion of the parameter space at more than 99% CL. Published by the American Physical Society 2024

Hostert, Matheus (ORCID:0000000295848877)↗

Measurement of Charged-current Muon Neutrino–argon Interactions Without Final-state Pions Using the MicroBooNE Detector

This thesis presents a new high-statistics measurement of flux-integrated single- and double-differential cross sections for charged-current muon neutrino interactions on argon nuclei without final-state pions. The analysis utilizes the full 1.3 $\times$ $10^{21}$ protons-on-target dataset collected by the MicroBooNE liquid argon time projection chamber between 2015 and 2020 at Fermilab's Booster Neutrino Beam. The results of this study are reported with respect to final-state muon kinematic variables and compared with predictions from commonly used neutrino event generators. In one-dimensional distributions, all generators perform reasonably well. However, in two dimensions, only a few demonstrate good agreement with the data. These findings provide valuable insight into characterizing neutrino-nucleon interactions. Such advancements are vital for future long-baseline neutrino experiments, which aim to accurately measure neutrino oscillation and investigate beyond-the-Standard-Model physics with high sensitivity.

Englezos, Panagiotis [Rutgers U., Piscataway (main↗

Cryogenic electronics for noble liquid neutrino detectors

In this paper we present the general features of cryogenic (or “cold”) electronics for noble liquid time projection chambers, with design principles and details for neutrino physics, a brief history of the technology and details of recent research and development that is driving the design of the detectors under construction. Finally, some comments on future R&D envisioned and the impact of this work on other fields is described. “Cold” in the context of this work applies to CMOS devices operated at 77 K and above, at liquids temperatures of LAr (89 K), LKr (125 K) and LXe (165 K), with most of the tests performed in, or at LN 2 (77 K). Additionally, the paper is concentrated on the design of cold electronics for large liquid argon TPCs, those that have been successfully operated, MicroBooNE and ProtoDUNE, and those designed or under construction, such as SBND and DUNE first and second 10 kton modules. The high performance achieved with MicroBooNE and ProtoDUNE – a high signal-to-noise ratio combined with high stability of response – is mainly due to the integral approach to design and construction of sensing electrodes with cold readout electronics in a modular approach with the cryostat signal feed-throughs incorporating warm interface electronics into a Faraday cage with the cryostat. The integral concept is described in some detail in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The System for on-Axis Neutrino Detection at the DUNE Near Detector complex

The Deep Underground Neutrino Experiment Near Detector complex aims at constraining the systematic uncertainties and deconvolving the neutrino beam flux and cross-section models. The System for on-Axis Neutrino Detection (SAND) is the Near Detector component permanently on-axis. SAND is based on the 0.6 T superconducting magnet and electromagnetic calorimeter previously used in the KLOE experiment. The 40 m3 magnetic volume will be filled with an active target/tracker system. One considered option foresees an upstream liquid Argon active target (about 1.5 t) and a Straw Tube Tracker (about 5 t). In this talk the design of SAND will be described and its performances discussed in view of the SAND primary goals, namely the beam monitoring and neutrino flux measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 0∼30–0140 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗