Remotely Discerning Radioactive Source Type via Laser-Driven Electron Avalanche in Air
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Threshold of parametric oscillator system with idler modes in same frequency spacing as laser pump source
This paper describes techniques that have been developed at JPL for visualization and measurements of droplet fields in a moving airstream. The techniques have been applied to a variety of problems which include simulation of heavy rain conditions in a wind tunnel, engine ingestion of wheel spray, analysis of fuel nozzle sprays and aerodynamic breakup of non-Newtonian liquids. The approach pursued here is direct imaging using a pulsed laser illumination source, followed by digital processing of photographic images. A laser double pulse technique has been used for determination of droplet velocities. Laser induced fluorescence has been used to enhance droplet definition in photographic images. The image processing software developed is capable of distinguishing between out-of-focus and in-focus drops, retaining only the latter for size determination.
Work on the development of an interferometric system for the purpose of absolute length determination commenced in January of this year. Our goal is to develop a system capable of measurements on the order of one meter with an accuracy of 1 part in 10 or greater. A modified Michelson bread board with stabilized laser diode source was assembled. Some preliminary measurements began using the tunable Santek laser in an FM modulation scheme. During this same period a literature search yielded a paper by Suematsu and Takeda which discusses a promising fourier transform technique for real time data analysis. We are in the process of evaluating this technique while we continue to change and upgrade the system configuration.
The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.
Linear accelerator based X-ray free electron laser (FEL) light sources provide an important tool for scientific discoveries. Most of these light source facilities employ a laser heater to increase the electron beam’s uncorrelated energy spread to suppress microbunching instability through the linear accelerators. In this paper, we first studied the microbunching instability in an X-ray FEL linear accelerator with lower initial peak current (~ 10 A) and moderate final peak currents (1-2 kA). In this regime, the microbunching instability can be substantially mitigated with modest initial uncorrelated energy spread. Here, we then suggested a less expensive method to mitigate the microbunching instability using a section of low beta FODO lattice instead of the laser heater. With the use of the high brightness electron beam from a photoinjector, the intrabeam scattering effect inside the beam through the FODO lattice can generate sufficient uncorrelated energy spread to mitigate the microbunching instability. At last, we demonstrated the feasibility of this method with self-consistent solution of the Fokker–Planck equation through the X-ray FEL linear accelerator.
Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.
In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.
Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.
Single-arm double-mode double-order optical waveguide interferometer utilizes interference between two propagating modes of different orders. Sensing effect results from the change in propagation conditions of the modes caused by the environment. The waveguide is made as an open asymmetric slab structure containing a dye-doped polymer film onto a fused quartz substrate. It is more sensitive to the change of environment than its conventional polarimetric analog using orthogonal modes (TE and TM) of the same order. The sensor still preserves the option of operating in polarimetric regime using a variety of mode combinations such as TE(sub 0)/TM(sub 0) (conventional), TE(sub 0)/TM(sub 1), TE(sub 1)/TM(sub 0), or TE(sub 1)/TM(sub 1) but can also work in nonpolarimetric regime using combinations TE(sub 0)/TM(sub 1) or TE(sub 0)/TM(sub 1). Utilization of different mode combinations simultaneously makes the device more versatile. Application of the sensor to gas sensing is based on doping polymer film with an organic indicator dye sensitive to a particular gas. Change of optical absorption spectrum of the dye caused by the gaseous pollutant results change of the reactive index of the dye-doped polymer film that can be detected by the sensor. As an indicator dyes, we utilize Bromocresol Purple doped into polymer poly(methyl) methacrylate, which shows a reversible growth of the absorption peak neat 600 nm after exposure to wet ammonia. We have built a breadboard prototype of the sensor with He-Ne laser as a light source and with a single mode fiber input and a multimode fiber output. The prototype showed sensitivity to temperature change of the order of 2 C per one full oscillation of the signal. The sensitivity of the sensor to the presence of wet ammonia is 200 ppm per one full oscillation of the signal. The further improvements include switching to a longer wavelength laser source (750-nm semiconductor laser), substitution of poly(methyl) methacrylate with hydrophilic high-temperature polyimide, and increase the doping rate of indicator dye. All these improvements are expected to bring sensitivity to 10 ppm of ammonia per one full oscillation of signal independent on the humidity of ambient air. The proposed sensor can be used as a robust and inexpensive stand-alone instrument for continuous environment pollution monitoring.
Recent progress with powerful, efficient, and coherent monolithic diode master-oscillator/power-amplifier (M-MOPA) systems is promising for the development of a space-based diode laser power station. A conceptual design of a 50-kW diode laser power module was made for space-based power stations capable of beaming coherent power to the moon, Martian rovers, or other satellites. The laser diode power module consists of a solar photovoltaic array or nuclear power source, diode laser arrays (LDAs), a phase controller, beam-steering optics, a thermal management unit, and a radiator. Thermal load management and other relevant aspects of the system (such as power requirements and system mass) are considered. The 50-kW power module described includes the highest available efficiency of LD M-MOPA system to date. However, the overall efficiency of three amplifier stages, including the coupling efficiency, turns out to be 55.5 percent. Though a chain of PA stages generates a high-power coherent beam, there is a penalty due to the coupling loss between stages. The specific power of the 50-kW module using solar power is 6.58 W/kg.
This paper describes a lifetime PSP system that has recently been developed using pulsed light-emitting diode (LED) lamps and a new interline transfer CCD camera technology. This system alleviates noise sources associated with lifetime PSP systems that use either flash-lamp or laser excitation sources and intensified CCD cameras for detection. Calibration curves have been acquired for a variety of PSP formulations using this system, and a validation test was recently completed in the Subsonic Aerodynamic Research Laboratory (SARL) at Wright-Patterson Air Force Base (WPAFB). In this test, global surface pressure distributions were recovered using both a standard intensity-based method and the new lifetime system. Results from the lifetime system agree both qualitatively and quantitatively with those measured using the intensity-based method. Finally, an advanced lifetime imaging technique capable of measuring temperature and pressure simultaneously is introduced and initial results are presented.
The widely established techniques for the generation of ultrashort optical pulses rely on passive mode locking of lasers, with the output pulse duration and emission spectrum determined by the intrinsic lifetime of laser transition in the gain medium. Due to the instantaneous nature of nonlinear gain, optical parametric oscillators (OPOs) are capable of generating optical radiation in all timescales from continuous-wave (cw) to ultrashort femtosecond regime, if driven by laser pump sources in the corresponding time domain. In the ultrashort timescale, operation of OPOs conventionally relies on mode-locked pump lasers, with the concomitant disadvantages of large footprint and high cost. At the same time, the lack of gain storage mandates the use of synchronous pumping, resulting in increased complexity. In this paper, we present the concept of phase-modulated OPO driven by cw pump laser. The approach overcomes the traditional drawbacks of ultrafast OPOs, enabling femtosecond pulse generation without the need for synchronous pumping, resulting in a simplified, compact, and cost-effective architecture using cw input pump lasers. We derive a mean-field equation for a degenerate χ ( 2 ) OPO driven by a cw laser with intracavity electro-optic modulator (EOM), and also including dispersion compensation. The equation predicts the formation of stable femtosecond pulses ( < 200 fs ) , in both normal and anomalous dispersion regimes, with a controllable repetition rate determined by the frequency of the EOM. The remarkable functionality of the proposed scheme paves the way for the development of an alternative class of widely tunable coherent femtosecond light sources in both bulk and integrated format based on χ ( 2 ) OPOs using cw pump lasers. Published by the American Physical Society 2024
Laser light sources are commonly used in schlieren-based flow visualization techniques that are in development at NASA Langley Research Center. Of particular interest are high-intensity, low coherence sources that allow for high signal-to-noise schlieren imagery to be acquired without the laser speckle that typically occurs as a result of interference. Results from a self-aligned focusing schlieren system developed at NASA Langley and a background-oriented schlieren system are presented to highlight the effectiveness of these sources.
Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.
A CO2 laser heated, floating zone fiber growth process was developed. The resulting Al2O3 fibers exhibited the high room temperature strengths for large diameter fibers as well as high specific creep rupture strengths observed at 1093 C and 1316 C (2000 F and 2400 F). Single crystal fibers of TiC and Y2O3 were also grown. An optical system was developed to focus four CO2 laser beams onto the surface of a feed rod permitting the formation of highly controllable molten zones. The optical system permitted energy densities and angle of incidence of the beams to be adjusted over wide ranges. This optical system was incorporated into a controlled atmosphere, fiber growth furnace. The two principal advantages of a CO2 laser heat source are that ambient atmospheres may be freely selected to optimize fiber properties and the laser has no inherent temperature limit, so extremely high melting point materials can be melted. Both advantages were demonstrated.
An infrared measurement system is used that consists of a laser heating source, an infrared camera for data acquisition, and a video recorder for data storage. A laser beam is scanned over an airfoil, heating its surface to a few degrees above ambient. An infrared camera then measures the temperature of the airfoil over a two-dimensional field, and these temperatures are stored as a function of time on a video recorder. The resulting temperature pictures are digitized and an iterative approximation algorithm is used to extract the heat transfer coefficient. The resulting values are normalized to the natural convection condition. The technique has been applied in low-speed wind tunnel tests and compared to well-established hot-film measurements which were made simultaneously to confirm the flow conditions. Heat transfer coefficients were determined using a linear scanning pattern, to indicate the position of natural and of artificially induced transition on an airfoil, at various wind speeds. The technique is shown to be sensitive to transition at low Mach numbers. The advantages of the technique are discussed.