Preshot Report for the NIF Discovery Science DDCyl Campaign: D_Hyd_DDCyl_DRT_DDD/EEE/FFF
The first Discovery Science shot day with the NIF DDCyl campaign demonstrated that Rayleigh-Taylor instability growth during the deceleration phase is scale-invariant for targets that varied in radial dimension and implosion time-scale by a factor of three. Smaller cylindrical implosions at the OMEGA laser facility were compared to the larger cylinders fielded in our first NIF outing. Both sets of targets had an initial m = 20 sinusoidal perturbation machined on the inner surface of an embedded aluminum marker layer, with the amplitude larger by the same factor of three for the NIF-scale targets. We observed growth factors of 14 at late time (t=λ = 7:7 ns, where λ = 1 for OMEGA and λ = 3 for NIF). These used a high density (300 mg/cm³) CH foam core, providing a very long period of deceleration before the rebounding shock hit the incoming spike tips, but the final convergence was only CR≈ 2:25. For our second shot day with this campaign, we are attempting to increase the convergence ratio to CR≥ 5 before reshock, while still measuring instability growth during the convergence/deceleration phase. As discussed in previous reports, the best way to increase convergence before reshock is to lower the density of the central foam. The preshot designs called for the use of a 30 mg/cm³ CH foam, though the as-built foams are closer to 40-42 mg/cm³, which is predicted to result in a final CR≈ 5:1 before reshock. Other than the lower foam density, the target design is identical to those used previously.