Ultrafast Space-time and Spectrum-time Resolved Diagnostics of Multicharged Femtosecond Laser Microplasma

We present the review of the recent experimental studies of fundamental mechanisms of femtosecond laser plasma formation and evolution performed in A. M. Prokhorov General Physics Institute of Russian Academy of Sciences. The main object we dealt with was the micro-sized plasma produced in gases with high intensity (up to 5x10{sup 17} W/cm{sup 2}), tightly focused (to a few microns in diameter) IR and UV femtosecond laser pulses. The main attention in the experiments was paid to the initial stage of microplasma formation and evolution characterized by strong laser-plasma coupling resulting in efficient ionization and heating of the medium, distortion of laser beam, and nonlinear spectral conversion of laser radiation to the continuum and laser harmonics. Using a precise pump-probe micro-interferometric technique the dynamics of plasma was studied with femtosecond time-resolution in a wide density range--from a minimal detectable electron concentration (10{sup 19} cm{sup -3}) to the almost total (down to nuclei) ionization of ions occurred under femtosecond excitation. The obtained time-dependences of plasma density were analyzed. It was observed, for the first time, that a characteristic time of femtosecond laser plasma formation in gases considerably (in times) exceeds the duration of the pump laser pulse. This postionization process is attributed to impact ionization of plasma by hot electrons. We compare the results of the experiments with what the developed theory predicts. Using an ultrafast streak-camera-based spectroscopy technique the temporal evolution of microplasma emission and the dynamics of spectral lines formation in UV-visible range were studied with picosecond time-resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a digital multiradian phase detector and its application in fusion plasma interferometry

We discuss the circuit design of a digital multiradian phase detector that measures the phase difference between two 10 kHz square wave TTL signals and provides the result as a binary number. The phase resolution of the circuit is 1/64 period and its dynamic range is 256 periods. This circuit has been developed for fusion plasma interferometry with submillimeter waves on the ASDEX Upgrade tokamak. The results from interferometric density measurement are discussed and compared to those obtained with the previously used phase detectors, especially with respect to the occurrence of phase jumps. It is illustrated that the new phase measurement provides a powerful tool for automatic real-time validation of the measured density, which is important for feedback algorithms that are sensitive to spurious density signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of X-Ray Optical Anisotropy of Materials by means of X-Ray Interferometry

A novel approach is proposed in the present work for investigation of X-ray optical anisotropy of materials, that is based on X-ray interferometric method of measurements. Unlike the existing methods, where the specimen to be tested is placed in the path of one of interfering beams, in the proposed approach the specimens under investigation are placed directly in the paths of both the interfering beams, owing to which the impact of other factors on the shift of interference Moire fringes is eliminated. In this way the Moire fringes simultaneously appear during the same exposure both in the absence and presence of specimens with different orientations of optical axes. Due to the fact that the relative displacement of Moire fringes is observed in three different columns of the same beam, it becomes possible to simultaneously observe and immediately identify the presence of X-ray optical anisotropy, as well as to measure the values of refractive indices n{sub o} and n{sub e} for specimens under study. By means of proposed method the X-ray optical anisotropy of cellophane film was registered and values of refractive indices n{sub o} and n{sub e} for cellophane were measured. It was established that cellophane is X-ray optically positive anisotropic medium.

36 MATERIALS SCIENCE↗

A Software Tool for Processing the Displacement Time Series Extracted from Raw Radar Data

The application of high-resolution radar waveform and interferometric principles recently led to the development of a microwave interferometer, suitable to simultaneously measuring the (static or dynamic) deflection of several points on a large structure. From the technical standpoint, the sensor is a Stepped Frequency Continuous Wave (SF-CW), coherent radar, operating in the K{sub u} frequency band.In the paper, the main procedures adopted to extract the deflection time series from raw radar data and to assess the quality of data are addressed, and the MATLAB toolbox developed is described. Subsequently, other functions implemented in the software tool (e.g. evaluation of the spectral matrix of the deflection time-histories, identification of natural frequencies and operational mode shapes evaluation) are described and the application to data recorded on full-scale bridges is exemplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II

A high spatial resolution two color [CO{sub 2}, {lambda}=10.6 {mu}m/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and {lambda}=1.064 {mu}m] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO{sub 2} (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density measurements using coherence imaging spectroscopy based on Stark broadening

A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H{sub {gamma}} line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of reflectometry Bragg backscattering spectral responses in the absence of a cutoff layer

Experimental reflectometry signals obtained in the absence of a cutoff layer, with the possibility of interferometric operation excluded, show a coherent and recurrent frequency spectrum signature similar to an Alfven cascade signature. A possible explanation resides in the modulation of a resonant Bragg backscattering response by an Alfven mode structure located at the center of the plasma whose frequency of oscillation modulates the backscattered signal in a conformable way. This situation is modeled and simulated using an O-mode full-wave Maxwell finite-difference time-domain code and the resulting signatures are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attosecond Nonlinear Optics

We report nonlinear multiphoton processes in atoms and molecules by intense high harmonics and their applications to attosecond pulse characterization. Phase matched high harmonics by a loosely focusing geometry produce highly focusable intensity with fully spatiotemporal coherence, which is sufficient to induce nonlinear optical phenomena in the extreme ultraviolet and soft x-ray (XUV) region. With this XUV coherent light source, two-photon double ionization in He is demonstrated with 42-eV high harmonic photons. On the other hand, when intense high harmonics around 20 eV is subjected to N{sub 2} molecules, occurrence of Coulomb explosion following to two-photon double ionization is observed in attosecond temporal precision. Taking advantage of larger cross section of two-photon ionization in molecules, we successfully perform the interferometric autocorrelation of an attosecond pulse train with the ion signals produced by Coulomb explosion of nitrogen molecules. The result reveals the phase relation between attosecond pulses in the train.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer

In weakly absorbing materials such as polymers and soft tissue, x-ray phase sensitive imaging methods can provide substantially enhanced contrast compared to classical, absorption based radiography. For specific applications, the latter can be applied in a dual energy scheme that helps to identify, discriminate and/or quantify materials. In this paper, we report on a new method that combines the idea of dual energy with x-ray phase contrast imaging and thus provides material sensitivity among poor absorbers. The dual energy modality cannot be applied in common phase contrast imaging schemes because of their demand for limited bandwidth or even monochromatic x-ray sources. Our new interferometric method based on diffraction gratings can overcome this shortcoming and thus simultaneously deliver x-ray phase contrast images for two distinct x-ray energy intervals. It has been shown that high quality images can be obtained with the dual energy phase setup. Energy spectra with 40 kV and 70 kV were applied to obtain low- and high-energy images, respectively. Furthermore, an estimation of the effective energy in the image formation process for absorption and phase contrast was experimentally determined. Examples are shown for which the dual energy phase contrast modality delivers complementary information on material composition when compared with the conventional dual energy scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced room temperature oxidation in silicon and porous silicon under 10 keV x-ray irradiation

We report the observation of enhanced oxidation on silicon and porous silicon samples exposed in air ambient to high-dose-rate 10 keV x-ray radiation at room temperature. The evolution of the radiation-induced oxide growth is monitored by ellipsometry and interferometric reflectance spectroscopy. Fourier transform infrared (FTIR) spectroscopy shows the emergence of Si-O-Si stretching modes and corresponding suppression of SiH{sub x} and Si-Si modes in the porous silicon samples. The radiation response depends strongly on initial native oxide thickness and Si-H surface species. The enhanced oxidation mechanism is attributed to photoinduced oxidation processes wherein energetic photons are used to dissociate molecular oxygen and promote the formation of more reactive oxygen species.

36 MATERIALS SCIENCE↗

A high sensitivity ultralow temperature RF conductance and noise measurement setup

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of Optical Bullets in Laser-Driven Plasma Bubble Accelerators

Electron density bubbles generated in plasma of density n{sub e{approx}10{sup 19}/cm{sup 3}} are shown to reshape copropagating probe pulses into optical 'bullets'. The bullets, reconstructed by frequency-domain interferometric techniques, are used to visualize bubble formation independently of relativistic electron generation.

43 PARTICLE ACCELERATORS↗

Optical Frequency Domain Visualization of Electron Beam Driven Plasma Wakefields

Bunch driven plasma wakefield accelerators (PWFA), such as the 'plasma afterburner', are a promising emerging method for significantly increasing the energy output of conventional particle accelerators. The study and optimization of this method would benefit from an experimental correlation of the drive bunch parameters and the accelerated particle parameters with the corresponding plasma wave structure. However, the plasma wave structure has not been observed directly so far. We will report ongoing development of a noninvasive optical Frequency Domain Interferometric (FDI) and Holographic (FDH) diagnostics of bunch driven plasma wakes. Both FDI and FDH have been previously demonstrated in the case of laser driven wakes. These techniques employ two laser pulses co-propagating with the drive particle bunch and the trailing plasma wave. One pulse propagates ahead of the drive bunch and serves as a reference, while the second is overlapped with the plasma wave and probes its structure. The multi-shot FDI and single-shot FDH diagnostics permit direct noninvasive observation of longitudinal and transverse structure of the plasma wakes. The experiment is being developed at the 70 MeV Linac in the Accelerator Test Facility at Brookhaven National Laboratory to visualize wakes generated by two and multi-bunch drive beams.

43 PARTICLE ACCELERATORS↗

Mirrorlike pulsed laser deposited tungsten thin film

Mirrorlike tungsten thin films on stainless steel substrate deposited via pulsed laser deposition technique in vacuum (10{sup -5} Torr) is reported, which may find direct application as first mirror in fusion devices. The crystal structure of tungsten film is analyzed using x-ray diffraction pattern, surface morphology of the tungsten films is studied with scanning electron microscope and atomic force microscope. The film composition is identified using energy dispersive x-ray. The specular and diffuse reflectivities with respect to stainless steel substrate of the tungsten films are recorded with FTIR spectra. The thickness and the optical quality of pulsed laser deposition deposited films are tested via interferometric technique. The reflectivity is approaching about that of the bulk for the tungsten film of thickness {approx}782 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical and Experimental Study of Optical Coherence Tomography (OCT) Signals Using an Analytical Transport Model

Optical coherence tomography (OCT) is a non-invasive low coherent interferometric technique that provides cross-sectional images of turbid media. OCT is based on the classical Michelson interferometer where the mirror of the reference arm is oscillating and the signal arm contains a biological sample. In this work, we analyzed theoretically the heterodyne optical signal adopting the so called extended Huygens-Fresnel principle (EHFP). We use simulated OCT images with known optical properties to test an algorithm developed by ourselves to recover the scattering coefficient and we recovered the scattering coefficient with a relative error less than 5% for noisy signals. In addition, we applied this algorithm to OCT images from phantoms of known optical properties; in this case curves were indistinguishable. A revision of the validity of the analytical model applied to our system should be done.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of excitation wavelength on dynamics of laser-produced tin plasma

We investigated the effect of the excitation wavelength on the density evolution of laser-produced tin plasmas, both experimentally and numerically. For producing plasmas, Sn targets were excited with either 10.6 {mu}m CO{sub 2} laser or 1.06 {mu}m Nd:yttrium aluminum garnet laser; both are considered to be potential excitation lasers for extreme ultraviolet lithography laser-produced plasma light sources. The electron density of the plasma during the isothermal expansion regime was estimated using an interferometric technique. The Stark broadening of isolated singly-ionized emission was employed for deducing the density during the plasma adiabatic expansion regime. Our results indicate that the excitation source wavelength determines the initial density of the plasma, as well the plume expansion dynamics. Numerical simulation using HEIGHTS simulation package agrees well with the experimentally measured density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A superconducting quantum interference device based read-out of a subattonewton force sensor operating at millikelvin temperatures

We present a scheme to measure the displacement of a nanomechanical resonator at cryogenic temperature. The technique is based on the use of a superconducting quantum interference device to detect the magnetic flux change induced by a magnetized particle attached on the end of the resonator. Unlike conventional interferometric techniques, our detection scheme does not involve direct power dissipation in the resonator, and therefore, is particularly suitable for ultralow temperature applications. We demonstrate its potential by cooling an ultrasoft silicon cantilever to a noise temperature of 25 mK, corresponding to a subattonewton thermal force noise of 0.5 aN/{radical}(Hz).