How to Make NCERC a go-to Destination for Shielding Benchmarks [Slides]
This talk will discuss the need and value of shielding benchmarks, discuss NCERC’s unique advantages for supporting them and ways NCERC can seize opportunity.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This talk will discuss the need and value of shielding benchmarks, discuss NCERC’s unique advantages for supporting them and ways NCERC can seize opportunity.
This lecture includes a look into progress in surrogate testing. This includes a new chiller that has been fabricated and testing that has resumed. Additional tests are being conducted, including: using formed aluminum gaskets, extended testing with natural uranium, testing with pseudo-spindle, testing with no vacuum. This lecture includes a look into the Reflector Design. Results for detailed model are consistent with results presented in CED-2. Calculations provide flexibility in the physical design of the reflectors (e.g. reflector segment widths and heights). Provided initial CAD models of reflector components.
This lecture includes discussion on the future work of finalizing the data analysis with dose as a function of radial distance and ion chamber integral. Further on agenda is to write manuscript of AFRRI dose characterization and write manuscripts of all NCSP-funded NAD work. Finally, it talks on the goal to publish in Radiation Measurements special issue.
This presentation includes a IER 441 assembly overview and the difference between IER 305 AND IER 441 with central test region assembly and hex pitch. Next this presentation looks at IER 441 procurement issues and delays and new hardware. additionally conducted was a SPRF/CX: IER 441 hardware test fit (Success)). This presentation concludes with lessons learned and acknowledgements.
The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.
Ceramic waste forms are designed to immobilize radionuclides for permanent disposal in geological repositories. One of the principal criteria for the effective incorporation of waste elements is their compatibility with the host material. In terms of performance under environmental conditions, the resistance of the waste forms to degradation over long periods of time is a critical concern when they are exposed to natural environments. Due to their unique crystallographic features and behavior in nature environment as exemplified by their natural analogues, ceramic waste forms are capable of incorporating problematic nuclear waste elements while showing promising chemical durability in aqueous environments. Recent studies of apatite- and hollandite-structured waste forms demonstrated an approach that can predict the compositions of ceramic waste forms and their long-term dissolution rate by a combination of computational techniques including machine learning, first-principles thermodynamics calculations, and modeling using kinetic rate equations based on critical laboratory experiments. By integrating the predictions of elemental incorporation and degradation kinetics in a holistic framework, the approach could be promising for the design of advanced ceramic waste forms with optimized incorporation capacity and environmental degradation performance. Such an approach could provide a path for accelerated ceramic waste form development and performance prediction for problematic nuclear waste elements.
The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.
It is important in neutron noise measurements and reactor startup to understand how the source distribution in a system compares to the equivalent fundamental-mode (EFM) source. Deviation from the fundamental mode source distribution increases as the system $\kappa$ eff increases. A correction factor, g *, is a measure of this deviation, and is the focus of this work. Two methods were utilized to simulate g *. These methods are compared to each other and (where applicable) previous results. The effects associated with nuclear material inner radius, materials of reflectors, and reflector thickness are also investigated.
FY2021 July Monthly Status Report for the Versatile Test Reactor
A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.
The purpose of a nondestructive assay is to accurately verify the declared mass of special nuclear material (SNM) samples in a limited amount of time. One measurement modality is neutron multiplicity counting (NMC), which relates time-correlated neutron detection rates to the mass of SNM present. Traditional theory assumes point-like sources, which can be ill-posed for kilogram-quantity, bulk samples. Recent theory was developed to improve NMC accuracy for non-point-like samples. This work preliminarily examines the theory with measured data. The OSCAR prototype (a 3-by-4 array of 5.08-cm-thick, 5.08-cm-diameter trans-stilbene organic scintillators) measures configurations of 29.41-49.00 kg of highly enriched uranium (93wt% 235 U). Adjusted factorial moments for the emitted neutron multiplicity distributions are used to account for the shape and type of SNM being measured.
The R-Matrix code SAMMY is a widely used nuclear data evaluation code focused on the resolved range, which includes corrections for experimental effects. The code is still mostly written in Fortran 77, and uses a memory management system suitable for the time of its initial writing (1984). A modernization effort is under way to bring the code in-line with modern software development practices. A continuous-integration testing framework was added, automating the large existing set of test cases. It is run on every commit. The memory management was updated to current standard practices suitable for modern software analysis tools. The code can be obtained from https://code.ornl.gov/RNSD/SAMMY. The resonance parameters and covariance information are now stored in C++ objects shared by SAMMY and AMPX, the processing code that generates nuclear data libraries for SCALE. This allows for easier maintenance and access to the resonance parameters inside and outside of SAMMY. This feature is already used by accessing and changing parameters in memory in the Bayesian Monte Carlo Evaluation Framework for Cross Sections Nuclear Data and Integral Benchmark Experiments project, Further plans include the switch to the ENDF reading and writing routines in AMPX, as these routines are more robust, easier to maintain, and support more features. Of note here is support for the new GNDS format. Previously it wasn’t easy to share the full covariance matrix for evaluations containing more than one isotope due to limitations on the ENDF format; this is now supported in GNDS. The data are currently available in a binary SAMMY format and can be exported to GNDS to make them more widely available and sharable. The next step will be to use the same resonance processing code at 0K in AMPX and SAMMY as one of the available Reich-Moore R-Matrix formalism. The first step toward this goal is to isolate the reconstruction into a module that takes resonance parameters as its input and does not depend on SAMMY global parameters. This goal has been achieved and it should now be possible to more easily change the resonance formalism and add enhancements as the Phenomenological R-Matrix parameterization of direct, doorway, and compound nuclear reactions discussed elsewhere on this conference. This concerted modernization and enhancement effort provides multiple advantages to the nuclear data community. It will allow parameter optimization using enhanced formalisms, including experimental effects, that better match complex experimental data. Then those evaluated parameters can immediately be passed off to AMPX to be reconstructed with the exact same cross section model and be put into a data library for subsequent testing using SCALE and the Valid Benchmark suite or other suitable benchmark suites.
Accurate knowledge of the 237 Np($n$; γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. A measurement of the 237 Np($n$; γ) 238 Np cross section was performed using a well characterized fast neutron source and the results was compared with previous measurements and current nuclear data evaluations. This will provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np($n$; γ) 238 Np and an integral cross section of 359(10) mb was measured. The 238 Np half-life has been measured with a result of 50.34(7) hours. An integral measurement of the 237 Np($n$; γ) 238 Np cross section has been measured. This result has been compared to the calculated integral cross section using the ENDF/BVIII.0 and JENDL-4.0 evaluated cross sections and found to be in good agreement with ENDF/BVIII.0 value of 367 mb. The JENDL-4.0 evaluation yields a value of 312 mb, which is significantly lower than the measured cross section.
A statistically predicted tendency for neutrons produced inside fission reactors to form in clusters can cause asymmetrical energy production that is counterbalanced, at least in part, by the spontaneous fission of radioactive material in the reactor. This neutron-clustering effect theory has been demonstrated in a nuclear reactor for the first time and was described in an article published by Los Alamos National Laboratory. The findings of a study supported by the Department of Energy’s Nuclear Criticality Safety Program, funded through the National Nuclear Security Administration, and carried out in collaboration with two French nuclear agencies—the Institute for Radiological Protection and Nuclear Safety (IRSN) and the Atomic Energy Commission (CEA)—could improve reactor safety and lead to more accurate simulations, according to LANL. The team found that a complete die-off was avoided in the small reactor because spontaneous fission—nuclear splitting of radioactive material inside reactors that is not caused by direct impact from a fission neutron—creates more neutrons. The balance of fission chain reactions and spontaneous fission lessens the impact of energy bursts created by clustering neutrons.
FY2021 May Monthly Status Report for the Versatile Test Reactor
June 2021 Monthly Status Report for the Versatile Test Reactor Project
We present recent advances in the R-matrix formalism as well as the Bayesian evaluation framework for improved nuclear data evaluations. The advances in the R matrix formalism include: 1) direct processes, 2) doorway, as well as multistep, processes, and 3) various forms of the Reich-Moore approximation for eliminated capture channels. Furthermore, to address unreasonably small posterior uncertainties often encountered in nuclear data evaluations of large data sets using the conventional form of the Bayes’ theorem, we introduce imperfections (of the data or the model) as a formal evaluation tool for taming the evaluated uncertainties in harmony with Bayes’ theorem. These theoretical advances were motivated by the nuclear data evaluations of differential resolved resonance cross section data using the code SAMMY, as well as the integral benchmark experiments using the SCALE code system, being performed at Oak Ridge National Laboratory for the Nuclear Criticality Safety Program. Some pedagogical applications of the new formalism, as well as a snapshot of the SAMMY modernization efforts, will be presented.
In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.