Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “information measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module

This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.

Ilas, Germina↗

Limitations in Advanced Measurement Systems: An Overview for Power Systems

Measurements have been an essential part of managing the electric power system from the beginning. Surprisingly, today’s measurements are not always particularly trustworthy. Countless factors can influence measurement in real-world conditions. In this report, we look at the measurement system as a comprehensive information acquisition system with complicated interdependencies setting the limiting factors and affecting system performance. The first chapter provides an overview of the whole system and introduces the key elements of the limitations checklist. The second part of the document is a component checklist for measurement system limitations that concisely describes effects, common remedies, and underlying factors.

42 ENGINEERING↗

Multi-technique characterization of iron reduction by an Antarctic Shewanella : an analog system for putative Martian biosignature identification

ABSTRACT Microbes from terrestrial extreme environments enable testing of biosignature production in conditions relevant to astrobiological targets. Mars, which was likely more conducive to life during early warmer and wetter epochs, has inspired missions that search for signs of early life in the surficial rock record, including mineral or organic biosignatures. Microbial iron reduction is a common and ancient metabolism that may have also operated on other rocky celestial bodies. To investigate biosignature production during iron reduction, aShewanellasp. (strain BF02_Schw) isolated from a subglacial discharge known as Blood Falls, Antarctica, was incubated with the electron acceptor ferrihydrite (Fh). Biosignatures associated with Fh reduction were identified using a suite of techniques currently utilized or proposed for Mars missions, including X-ray diffraction and infrared, Mössbauer, and Raman spectroscopy. The biotic origin of features was validated by transcriptional changes observed between treatments with and without Fh and comparison to killed controls. In live treatments, Fh was reduced to magnetite and goethite, both detected in Martian lacustrine basins. Several soluble and volatile metabolites were also detected, including riboflavin and dimethyl sulfide (DMS), which could be astrobiological indicators of active microbial processes. While none of the identified biosignatures individually would serve as definitive proof of life (past or present), detecting concomitant features associated with known terrestrial biotic processes would provide compelling rationale for more targeted life detection missions. Terrestrial extremophiles can support the exploration of astrobiologically relevant microbial processes, validation of life detection instrumentation, and potentially the discovery of new biomarkers. IMPORTANCE Culture-based experiments with terrestrial extremophiles can elucidate biosignatures that may be analogous to those produced under extraterrestrial conditions, and thus inform sampling and technology strategies for future missions. Here, we demonstrate the production of several biosignatures under iron-reducing conditions byShewanellasp. BF02_Schw, originally isolated from an Antarctic analog feature. These biosignatures could be detectable using flight-ready instrumentation. Growth experiments with terrestrial extremophiles can identify biosignatures measurable by current methodologies and inform the development and optimization of techniques for detecting extant or extinct life on other worlds.

Biotechnology & Applied Microbiology↗

Batch Measurement Extremum Seeking Control of Distributed Energy Resources to Account for Communication Delays and Information Loss

Distributed Energy Resources (DER) have great potential to enhance the operation of electric power distribution systems. Previously, we explored the use of 2 Dimensional Extremum Seeking (2D-ES) control algorithms to enable model-free optimal control of DER to provide grid services to both the distribution and transmissions systems. Motivated by preliminary deployments of DER managed by 2D-ES algorithms in hardware-in-the-loop tests and in operational distribution grids, in this work, we extend the control scheme to accommodate communication delays and information loss. We propose a modification to the 2D-ES scheme to allow for the processing of batches of possibly noncontiguous objective function measurements at unknown and possibly uneven intervals. We provide a proof of the convergence of the batch 2D-ES (2D-BES) scheme when optimizing a generic convex objective function, as well as simulation results that demonstrate the suitability of the approach for substation active and reactive power target tracking.

Sankur, Michael↗

Increased power gains from wake steering control using preview wind direction information

Abstract. Yaw controllers typically rely on measurements taken at the wind turbine, resulting in a slow reaction to wind direction changes and subsequent power losses due to misalignments. Delayed yaw action is especially problematic in wake steering operation because it can result in power losses when the yaw misalignment angle deviates from the intended one due to a changing wind direction. This study explores the use of preview wind direction information for wake steering control in a two-turbine setup with a wind speed in the partial load range. For these conditions and a simple yaw controller, results from an engineering model identify an optimum preview time of 90 s. These results are validated by forcing wind direction changes in a large-eddy simulation model. For a set of six simulations with large wind direction changes, the average power gain from wake steering increases from only 0.44 % to 1.32 %. For a second set of six simulations with smaller wind direction changes, the average power gain from wake steering increases from 1.24 % to 1.85 %. Low-frequency fluctuations are shown to have a larger impact on the performance of wake steering and the effectiveness of preview control, in particular, than high-frequency fluctuations. From these results, it is concluded that the benefit of preview wind direction control for wake steering is substantial, making it a topic worth pursuing in future work.

17 WIND ENERGY↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Raw leaf temperature data from May 2017- Aug 2017 at the B34 and K34 towers in Manaus, Brazil

This data package contains raw data from leaf temperature measurements. Additional metadata, such as site information and equipment manuals, are included in the data package listed under Dataset Reference(s) along with all related data packages. Leaf temperature measurements were made using Teflon insulated type T thermocouples (OM-CP-OCTTEMP-A Nomad®, Omega Engineering) directly attached to the abaxial side of the leaf using a breathable white tape and configured to register measurements every 15 s. No data processing or QA/QC was done on the raw datasets. Processed datasets will be uploaded separately. Contact israelmdt@gmail.com if you need to use this dataset for additional information.

54 ENVIRONMENTAL SCIENCES↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

ESS-DIVE reporting format for field measurements of soil respiration

This is a new data and metadata reporting format for soil respiration data, based on engagement with a wide range of researchers in the earth and ecological sciences as well as expert advisory panels. Reporting formats are intended to be ‘bottom-up’, community-developed documents and templates that can enable consistent, findable, accessible, interoperable, and reproducible (FAIR) data; our goal was a reporting format that would be relevant and useful for synthesis activities, optimizing data discoverability and usability while not placing an undue burden on data contributors. The format is split into two levels of information—metadata about chambers (used to measure soil respiration in the field), and the measured data themselves. The file data_reportingformat_template.xlsx contains information on how the data table should be structured, including field names, field descriptions, and units; the chammetadata_reportingformat_template.xlsx file contains similar information for the chamber-level metadata. Fundamentally, this format aims to enable FAIR data through an easy-to-use guide for data providers interested in formatting their data in a common way, and provide ‘future-proofing’ capabilities to support reanalyses of soil respiration data, a globally-important component of the carbon cycle.

54 ENVIRONMENTAL SCIENCES↗

Graph states of atomic ensembles engineered by photon-mediated entanglement

Abstract Graph states are a broad family of entangled quantum states, each defined by a graph composed of edges representing the correlations between subsystems. Such states constitute versatile resources for quantum computation and quantum-enhanced measurement. Their generation and engineering require a high level of control over entanglement. Here we report on the generation of continuous-variable graph states of atomic spin ensembles, which form the nodes of the graph. We program the entanglement structure encoded in the graph edges by combining global photon-mediated interactions in an optical cavity with local spin rotations. By tuning the entanglement between two subsystems, we either localize correlations within each subsystem or enable Einstein–Podolsky–Rosen steering—a strong form of entanglement that enables the extraction of precise information from one subsystem through measurements on the other. We further engineer a four-mode square graph state, highlighting the flexibility of our approach. Our method is scalable to larger and more complex graphs, laying groundwork for measurement-based quantum computation and advanced protocols in quantum metrology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theory and Practice in Measuring In-Vitro Extensibility of Growing Plant Cell Walls

This chapter summarizes four extensometer techniques for measuring cell wall extensibility in vitro and discusses how the results of these methods relate to the concept and ideal measurement of cell wall extensibility in the context of plant cell growth. These in-vitro techniques are particularly useful for studies of the molecular basis of cell wall extension. Measurements of breaking strength, elastic compliance and plastic compliance may be informative about changes in cell wall structure, whereas measurements of wall stress relaxation and creep are sensitive to both changes in wall structure and wall-loosening processes, such as those mediated by expansins and some lytic enzymes. As a result, a combination of methods is needed to obtain a broader view of cell wall behavior and properties connected with the concept of cell wall extensibility.

36 MATERIALS SCIENCE↗

Forward sensitivity approach for estimating eddy viscosity closures in nonlinear model reduction

In this paper, we propose a variational approach to estimate eddy viscosity using forward sensitivity method (FSM) for closure modeling in nonlinear reduced order models. FSM is a data assimilation technique that blends model's predictions with noisy observations to correct initial state and/or model parameters. We apply this approach on a projection based reduced order model (ROM) of the one-dimensional viscous Burgers equation with a square wave defining a moving shock, and the two-dimensional vorticity transport equation formulating a decay of Kraichnan turbulence. We investigate the capability of the approach to approximate an optimal value for eddy viscosity with different measurement configurations. Specifically, we show that our approach can sufficiently assimilate information either through full field or sparse noisy measurements to estimate eddy viscosity closure to cure standard Galerkin reduced order model (GROM) predictions. Therefore, our approach provides a modular framework to correct forecasting error from a sparse observational network on a latent space. We highlight that the proposed GROM-FSM framework is promising for emerging digital twin applications, where real-time sensor measurements can be used to update and optimize surrogate model's parameters.

42 ENGINEERING↗

Dynamic signal recovery in distribution grids using compressive lossy measurements

Distribution system state estimation requires reliable aggregation of the measured data. However, the large volume of the measured data imposes a significant stress on the underlying communication infrastructure. With the challenges associated with measurement availability, current distribution systems are typically unobservable. To cope with the unobservability issue, compressive sensing theory allows us to recover system state information from a small number of measurements provided the states of the distribution system exhibit sparsity. In this paper, we evaluate the robustness of an updated Kalman filtered modified compressive sensing (KF-ModCS) technique that dynamically estimates the grid states using a small fraction of measured data. In practice, measurements used for sparsity based state estimation may also be intermittent due to communication network induced losses. Further, to understand the effect of packet losses on KF-ModCS, we provide an upper bound for the expected variances of the state estimation error for a given rate of information loss. This upper bound is further improved if the support set of the sparse signal that characterizes the state dynamics does not change over time and/or the reduced model is observable. Simulations based on two practical data sets collected from actual customers in a distribution grid validate the theoretical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

Performance Characterization of a Natural Gas–Air Rotating Detonation Engine

An experimental study of a rotating detonation engine (RDE) operating with natural gas and air at elevated chamber pressures and air preheat temperatures was conducted to quantify its performance at conditions representative of land-based power generation gas turbine engines. Here, the thrust produced by the combustor was measured to characterize its work output potential. High-frequency pressure transducers and broadband chemiluminescence measurements of the flame provided information about the wave structure and dynamics. Analysis of common performance metrics demonstrated the necessity of normalizing any RDE performance parameter by the driving system potential, typically the reactant manifold pressure. Application of a thermodynamic performance model to a generic RDE identified the area ratio between the RDE exhaust and injection throats as the primary parameter affecting delivered pressure gain. The model was further applied to draw comparison with experimental measurements of net pressure gain for identical flow conditions. Only one of the two tested injector configurations followed the predicted trends, suggesting that performance of the second was governed by physical processes other than the reactant thermodynamics. Although an absolute pressure gain was not demonstrated, it is promising that the natural gas–air RDE delivered up to 90% of the theoretical performance.

20 FOSSIL-FUELED POWER PLANTS↗

Quasi-Extended Range Optical Frequency Domain Reflectometry for Product Pipelines

Throughout the United States, large natural gas and product transmission pipelines exist. These pipelines are susceptible to failure through corrosion and cracking due to internal and external factors. As these transmission pipeline age, the likelihood of a catastrophic failure increases. The ability to the monitor corrosion and wall thickness of these pipelines is paramount to reduce risk of disastrous failure and increase reliability as well as safety. Optical frequency domain reflectometry can monitor distributed temperature and strain measurements along the natural gas and product pipelines. This measurement technique can provide valuable information of pipe structural health through hoop strain changes due to pipe wall thinning, temperature changes due to gas leaks based on Joule-Thomson effect. Since these pipelines are typically buried, the depth of the pipeline results in a potential loss in the sensing range where the fiber is not physically monitoring the hoop strain of the pipeline. A different configuration of the interferometer will allow for the distributed fiber measurement to start atop the pipeline itself. This configuration results in no loss of sensing range and maintains the sensing resolution of a typically interferometer for an optical frequency domain reflectometry measurement. The quasi-extended range distributed hoop strain measurements were demonstrated on an active transmission pipeline.

Brister, Matthew↗