A high resolution atlas of the galactic plane at 12 microns and 25 microns

High resolution images of the 12 micron and 25 micron IRAS survey data from each HCON crossing the Galactic Plane are being created for those regions that the original IRAS processing labeled as confused. This encompasses the area within 100 deg longitude of the Galactic Center and within 3 deg to 10 deg of the Plane. The procedures used to create the images preserve the spatial resolution inherent in the IRAS instrument. The images are separated into diffuse and point source components and candidate sources are extracted from the point source image after non-linear spatial sharpening. Fluxes are estimated by convolving the candidate sources with the point response function and cross-correlating with the original point source image. A source is considered real if it is seen on at least two HCON's with a rather generous flux match but a stringent position criterion. A number of fields spanning a range of source densities from low to high have been examined. Initial analysis indicates that the imaging and extraction works quite well up to a source density of about 100 sources per square degree or down to roughly 0.8 Janskys.

Price, Stephan D.↗

Remotely Estimating Total Suspended Solids Concentration in Clear to Extremely Turbid Waters Using a Novel Semi-Analytical Method

Total suspended solids (TSS) concentration is an important biogeochemical parameter for water quality management and sediment-transport studies. In this study, we propose a novel semi-analytical method for estimating TSS in clear to extremely turbid waters from remote-sensing reflectance (Rrs). The proposed method includes three sub-algorithms used sequentially. First, the remotely sensed waters are classified into clear (Type I), moderately turbid (Type II), highly turbid (Type III), and extremely turbid (Type IV) water types by comparing the values of Rrs at 490, 560, 620, and 754 nm. Second, semi-analytical models specific to each water type are used to determine the particulate backscattering coefficients (bbp) at a corresponding single wavelength (i.e., 560 nm for Type I, 665 nm for Type II, 754 nm for Type III, and 865 nm for Type IV). Third, a specific relationship between TSS and bbp at the corresponding wavelength is used in each water type. Unlike other existing approaches, this method is strictly semi-analytical and its sub-algorithms were developed using synthetic datasets only. The performance of the proposed method was compared to that of three other state-of-the-art methods using simulated (N = 1000, TSS ranging from 0.01 to 1100 g/m3) and in situ measured (N = 3421, TSS ranging from 0.09 to 2627 g/m3) pairs of Rrs and TSS. Results showed a significant improvement with a Median Absolute Percentage Error (MAPE) of 16.0% versus 30.2–90.3% for simulated data and 39.7% versus 45.9–58.1% for in situ data, respectively. The new method was subsequently applied to 175 MEdium Resolution Imaging Spectrometer (MERIS) and 498 Ocean and Land Colour Instrument (OLCI) images acquired in the 2003–2020 timeframe to produce long-term TSS time-series for Lake Suwa and Lake Kasumigaura, Japan. Performance assessments using MERIS and OLCI matchups showed good agreements with in situ TSS measurements.

Mulit-Wavelength↗

Ultrasonic Imaging Of Deep Arteries

Swept-frequency sound replaces pulsed sound. Ultrasonic medical instrument produces images of peripheral and coronary arteries with resolutions higher and at depths greater than attainable by previous ultrasonic systems. Time-delay-spectrometry imager includes scanning, image-processing, and displaying equipment. It sweeps in frequency from 0 to 10 MHz in 20 ms, pauses for 5 ms, and repeats sweep. Intended for use in noninvasive detection and measurement of atherosclerotic lesions.

Rooney, James A.↗

A neutron imaging device for sample alignment in a pulsed neutron scattering instrument

A neutron-imaging device for alignment purposes has been tested on the INES beamline at ISIS, the pulsed neutron source of Rutherford Appleton Laboratory (U.K.). Its use, in conjunction with a set of movable jaws, turns out extremely useful for scattering application to complex samples where a precise and well-defined determination of the scattering volume is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

The Design & Development of the Ocean Color Instrument Precision Superduplex Hybrid Bearing Cartridge

A high precision, high-resolution Ocean Color Imaging (OCI) instrument is under development for the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission which requires a pair of medium speed mechanisms to scan the ocean surface continuously. The design of the rotating telescope (RT) mechanism operating at 360 RPM and the half-angle mirror (HAM) mechanism synchronized at 180 RPM was concern for maintaining pointing precision over the required life and continuous operations. An effort was undertaken with the manufacturer to design and analyze a special bearing configuration to minimize axial and radial runout, minimize torque, and maintain nominal contact stresses and stiffness over the operating temperature range and to maximize life. The bearing design, development effort, analysis and testing will be discussed as will the technical challenges that this specific design imposed upon the mechanism engineers. Bearing performance, runout as achieved and verified during encoder installation and operating torque will be described.

mechanism↗

Measurement of thigmomorphogenesis and gravitropism by non-intrusive computerized video image processing

A video image processing instrument, DARWIN (Digital Analyser of Resolvable Whole-pictures by Image Numeration), was developed. It was programmed to measure stem or root growth and bending, and coupled to a specially mounted video camera to be able to automatically generate growth and bending curves during gravitropism. The growth of the plant is recorded on a video casette recorder with a specially modified time lapse function. At the end of the experiment, DARWIN analyses the growth or movement and prints out bending and growth curves. This system was used to measure thigmomorphagenesis in light grown corn plants. If the plant is rubbed with an applied force load of 0.38 N., it grows faster than the unrubbed control, whereas 1.14 N. retards its growth. Image analysis shows that most of the change in the rate of growth is caused in the first hour after rubbing. When DARWIN was used to measure gravitropism in dark grown oat seedlings, it was found that the top side of the shoot contracts during the first hour of gravitational stimulus, whereas the bottom side begins to elongate after 10 to 15 minutes.

Jaffe, M. J.↗

The Fundamental Structure of Coronal Loops

During the past ten years, solar physicists have attempted to infer the coronal heating mechanism by comparing observations of coronal loops with hydrodynamic model predictions. These comparisons often used the addition of sub ]resolution strands to explain the observed loop properties. On July 11, 2012, the High Resolution Coronal Imager (Hi ]C) was launched on a sounding rocket. This instrument obtained images of the solar corona was 0.2 ]0.3'' resolution in a narrowband EUV filter centered around 193 Angstroms. In this talk, we will compare these high resolution images to simultaneous density measurements obtained with the Extreme Ultraviolet Imaging Spectrograph (EIS) on Hinode to determine whether the structures observed with Hi ]C are resolved.

Winebarger, Amy↗

Time-Distance Helioseismology with the HMI Instrument

We expect considerable improvement of time-distance results from the Helioseismic and Magnetic Imager (HMI) instrument as opposed to the earlier MDI and GONG data. The higher data rate makes possible several improvements, including faster temporal sampling (45 sec), smaller spatial pixels (0.5 arc sec), better wavelength coverage (6 samples across the line all transmitted to the ground), and year-round coverage of the full disk. The higher spatial resolution makes possible better longitude coverage of active regions and supergranulation and also better latitude coverage. Doppler, continuum, and line depth images have a strong granulation signal. Line core images show little granulation. Analyses to test the limits of these new capabilities will be presented.

Duvall, Thomas L., Jr.↗

Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) baseline concept

There will be several state of the art spectrometers in operation on the NASA Polar Orbiting Platform (NPOP-1) as part of the Earth Observing System (EOS). The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument is presently being constructed for flight on the EOS. It is an imaging spectrometer utilizing a grating type, reflecting Schmidt optical design that must provide a 1.1 kilometer spatial resolution at nadir from a spacecraft altitude of 705 kilometers with a 1500 kilometer cross-track swath and a +/- 50 degree forward and aft tilt capability. The instrument is required to cover the wavelength range from 400 to 880 nanometers in approximately 15 nanometer steps with less than 2.3 percent instrument induced polarization. The absolute radiometric accuracy must be at least 5 percent over the full dynamic range of the instrument.

Magner, Thomas J.↗

Nuclear imaging of the breast: Translating achievements in instrumentation into clinical use

Approaches to imaging the breast with nuclear medicine and/or molecular imaging methods have been under investigation since the late 1980s when a technique called scintimammography was first introduced. This review charts the progress of nuclear imaging of the breast over the last 20 years, covering the development of newer techniques such as breast specific gamma imaging, molecular breast imaging, and positron emission mammography. Key issues critical to the adoption of these technologies in the clinical environment are discussed, including the current status of clinical studies, the efforts at reducing the radiation dose from procedures associated with these technologies, and the relevant radiopharmaceuticals that are available or under development. The necessary steps required to move these technologies from bench to bedside are also discussed.

60 APPLIED LIFE SCIENCES↗

Hard X-ray imaging facility for space shuttle: A scientific and conceptual engineering study

A shuttle-accommodated instrument for imaging hard X-rays in the study of nonthermal particles and high temperature particles in various solar and cosmic phenomena was defined and its feasibility demonstrated. The imaging system configuration is described as well as the electronics, aspect systems, mechanical and thermal properties and the ground support equipment.

Peterson, L. E.↗

Wide-Field InfraRed Survey Telescope (WFIRST) Mission and Synergies with LISA and LIGO-Virgo

The Wide-Field InfraRed Survey Telescope (WFIRST) is a NASA space mission in study for launch in 2024. It has a 2.4 m telescope, wide-field IR instrument operating in the 0.7 - 2.0 micron range and an exoplanet imaging coronagraph instrument operating in the 400 - 1000 nm range. The observatory will perform galaxy surveys over thousands of square degrees to J=27 AB for dark energy weak lensing and baryon acoustic oscillation measurements and will monitor a few square degrees for dark energy SN Ia studies. It will perform microlensing observations of the galactic bulge for an exoplanet census and direct imaging observations of nearby exoplanets with a pathfinder coronagraph. The mission will have a robust and wellfunded guest observer program for 25% of the observing time. WFIRST will be a powerful tool for time domain astronomy and for coordinated observations with gravitational wave experiments. Gravitational wave events produced by mergers of nearby binary neutron stars (LIGO-Virgo) or extragalactic supermassive black hole binaries (LISA) will produce electromagnetic radiation that WFIRST can observe.

Wide-Field InfraRed Survey Telescope (WFIRST) Miss↗

Planetary exploration sensor systems

Most of the instruments that have been used in planetary exploration have been either spectrometers or imaging devices. Instruments of these types are being developed for the Galileo and VOIR (Venus Orbiting Imaging Radar) missions. Galileo will take advantage of new CCD (charge-coupled device) technology, and VOIR will use techniques of synthetic aperture radar developed for Seasat. For determining the macrostructure of mineral resources, the best approach is believed to involve acoustic imaging, essentially a seismic data processing technique. Determinations of microstructure would require a light microscope and an electron microscope. For determining the nature and form of volatiles, a differential scanning calorimeter could be used. To determine the mineral composition, an electron beam microprobe with X-ray fluorescence and spectroscopy would be used.

Saunders, R. S.↗

Visualization of Multi-Dimensional Imaging Data for the DIII-D National Fusion Facility

With funding provided from the Office of Fusion Energy Science’s program on Diagnostic Systems for Magnetic Fusion Energy Sciences, the PI and his team have pioneered the development of microwave imaging systems for magnetic fusion plasma diagnostics. Specifically, electron cyclotron emission (ECE) imaging [1], a passive radiometric technique, measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) [2], an active radar imaging technique, measures electron density fluctuations. These microwave imaging diagnostic instruments developed by UC Davis have made important contributions to fusion science in a relatively short period of time from their original installation on DIII-D. The microwave imaging diagnostic technique has matured considerably since the beginning of a fruitful collaboration with DIII-D and PPPL, and has also been adopted at preeminent tokamak facilities worldwide. As discussed in detail in the following, this has continued with the development of revolutionary microwave diagnostic instruments employing monolithic millimeter wave integrated circuit (MMIC) system-on-chip (SoC) technology. Specifically, “chip” receivers mounted in liquid crystal polymer (LCP) modules have been demonstrated to dramatically improve the performance of the electron cyclotron emission imaging (ECEI) system including: 30x improvement in noise temperature thereby permitting absolute 2-D electron temperature images, outstanding shielding against out-of-band interference including microwave bursting which had plagued previous ELM studies using the old quasi-optical mini-lens ECEI system, and independent modules facilitating flexible repair and replacement. Under the “Visualization of multi-dimensional imaging data for the DIII-D National Fusion Facility” program, funding was provided for a research scientist postdoc and a Ph.D. student to support physics studies at DIII-D employing these instruments. This endeavor is synergistic with our current grant under the DOE Fusion Energy Sciences (FES) program on Diagnostic Systems for Magnetic Fusion Energy Sciences. This support considerably increased the scientific output of the diagnostics. The activities were strongly focused in the areas of pedestal and ELM stability, energetic particle confinement, and the early detection and avoidance of tokamak disruptions employing the microwave imaging diagnostic instruments developed under the advanced diagnostics program where imaging of the ELM crash was made possible by the elimination of the interference from the associated microwave “bursts”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mees CCD imaging spectrograph

The Mees CCD (MCCD0 instrument is an imaging spectroscopy device which uses the 25-cm coronagraph telescope and the 3.0-m Coude spectrograph at Mees Solar Observatory on Haleakala, Maui. The instrument works with resolving power up to about 200,000 with significant throughput from 3934 A (Ca II K) to about 10,000 A. A fast guiding active mirror stabilizes the image during observations. A rapidly writing magnetic tape storage system allows observations to be recorded at 256 kbytes/s. Currently, the MCCD is used for imaging spectroscopy of solar flares at 6563 A (H-alpha), and velocity measurements of umbral oscillations; future plans include emission line studies of active region coronae, and photospheric studies of solar oscillations.

Penn, Matthew J.↗