At least 487 records · Page 27

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. III. Responses after labyrinthectomy

The horizontal angular vestibuloocular reflex (VOR) evoked by high-frequency, high-acceleration rotations was studied in four squirrel monkeys after unilateral labyrinthectomy. Spontaneous nystagmus was measured at the beginning and end of each testing session. During the period that animals were kept in darkness (4 days), the nystagmus at each of these times measured approximately 20 degrees /s. Within 18-24 h after return to the light, the nystagmus (measured in darkness) decreased to 2.8 +/- 1.5 degrees /s (mean +/- SD) when recorded at the beginning but was 20.3 +/- 3.9 degrees /s at the end of the testing session. The latency of the VOR measured from responses to steps of acceleration (3,000 degrees /s(2) reaching a velocity of 150 degrees /s) was 8.4 +/- 0.3 ms for responses to ipsilesional rotations and 7.7 +/- 0.4 ms for contralesional rotations. During the period that animals were kept in darkness after the labyrinthectomy, the gain of the VOR measured during the steps of acceleration was 0.67 +/- 0.12 for contralesional rotations and 0.39 +/- 0.04 for ipsilesional rotations. Within 18-24 h after return to light, the VOR gain for contralesional rotations increased to 0.87 +/- 0.08, whereas there was only a slight increase for ipsilesional rotations to 0.41 +/- 0. 06. A symmetrical increase in the gain measured at the plateau of head velocity was noted after the animals were returned to light. The VOR evoked by sinusoidal rotations of 2-15 Hz, +/-20 degrees /s, showed a better recovery of gain at lower (2-4 Hz) than at higher (6-15 Hz) frequencies. At 0.5 Hz, gain decreased symmetrically when the peak amplitude was increased from 20 to 100 degrees /s. At 10 Hz, gain was decreased for ipsilesional half-cycles and increased for contralesional half-cycles when velocity was raised from 20 to 50 degrees /s. A model incorporating linear and nonlinear pathways was used to simulate the data. Selective increases in the gain for the linear pathway accounted for the recovery in VOR gain for responses at the velocity plateau of the steps of acceleration and for the sinusoidal rotations at lower peak velocities. The increase in gain for contralesional responses to steps of acceleration and sinusoidal rotations at higher frequencies and velocities was due to an increase in the contribution of the nonlinear pathway. This pathway was driven into cutoff and therefore did not affect responses for rotations toward the lesioned side.

NASA Discipline Neuroscience↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Lan, C. Edward↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Chin, Suei↗

Shear dampers for deflections of micro-inch magnitudes

The rotation of the TV camera on the Mariner Jupiter/Saturn 1977 (MJS77) spacecraft will excite the long magnetometer and heavy RTG booms which are slightly damped perturbances that have long settling times. To ensure clear TV pictures additional damping was required over micro-inch displacements and at low frequencies. The solution incorporated elastomeric shear dampers at the base of these booms which possessed high loss tangent values in the expected frequency and temperature ranges. Presented are the shear damper design, results of full scale horizontal boom tests and relative effects of damper sizing and temperature. Boom instrumentation and excitation used for the full scale tests are also discussed.

Otth, D.↗

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.↗

Ion heating by waves with frequencies below the ion gyrofrequency

Ion heating by broadband and coherent waves with relatively small amplitude and frequencies below the ion gyrofrequency is examined. The theoretical results, verified by test particle calculations, show that such waves can heat ions to high energies, and in particular produce the ion conic distributions observed in the earth's magnetosphere. The model utilized differs from other approaches in that neither quasi-linear theory nor stochastic acceleration in a large amplitude wave are used to heat ions. This heating mechanism may be significant in other geophysical and astrophysical environments.

Temerin, M.↗

High accuracy time transfer synchronization

In July 1994, the U.S. Naval Observatory (USNO) Time Service System Engineering Division conducted a field test to establish a baseline accuracy for two-way satellite time transfer synchronization. Three Hewlett-Packard model 5071 high performance cesium frequency standards were transported from the USNO in Washington, DC to Los Angeles, California in the USNO's mobile earth station. Two-Way Satellite Time Transfer links between the mobile earth station and the USNO were conducted each day of the trip, using the Naval Research Laboratory(NRL) designed spread spectrum modem, built by Allen Osborne Associates(AOA). A Motorola six channel GPS receiver was used to track the location and altitude of the mobile earth station and to provide coordinates for calculating Sagnac corrections for the two-way measurements, and relativistic corrections for the cesium clocks. This paper will discuss the trip, the measurement systems used and the results from the data collected. We will show the accuracy of using two-way satellite time transfer for synchronization and the performance of the three HP 5071 cesium clocks in an operational environment.

Wheeler, Paul J.↗

Determining the Accuracy of Aerodynamic Model Parameters Estimated from Flight Test Data

An important part of building mathematical models based on measured data is calculating the accuracy associated with statistical estimates of the model parameters. Indeed, without some idea of this accuracy, the parameter estimates themselves have limited value. In this work, an expression for computing quantitatively correct parameter accuracy measures for maximum likelihood parameter estimates with colored residuals is developed and validated. This result is important because experience in analyzing flight test data reveals that the output residuals from maximum likelihood estimation are almost always colored. The calculations involved can be appended to conventional maximum likelihood estimation algorithms. Monte Carlo simulation runs were used to show that parameter accuracy measures from the new technique accurately reflect the quality of the parameter estimates from maximum likelihood estimation without the need for correction factors or frequency domain analysis of the output residuals. The technique was applied to flight test data from repeated maneuvers flown on the F-18 High Alpha Research Vehicle (HARV). As in the simulated cases, parameter accuracy measures from the new technique were in agreement with the scatter in the parameter estimates from repeated maneuvers, while conventional parameter accuracy measures were optimistic.

Morelli, Eugene A.↗

Accuracy of Aerodynamic Model Parameters Estimated from Flight Test Data

An important put of building mathematical models based on measured date is calculating the accuracy associated with statistical estimates of the model parameters. Indeed, without some idea of this accuracy, the parameter estimates themselves have limited value. An expression is developed for computing quantitatively correct parameter accuracy measures for maximum likelihood parameter estimates when the output residuals are colored. This result is important because experience in analyzing flight test data reveals that the output residuals from maximum likelihood estimation are almost always colored. The calculations involved can be appended to conventional maximum likelihood estimation algorithms. Monte Carlo simulation runs were used to show that parameter accuracy measures from the new technique accurately reflect the quality of the parameter estimates from maximum likelihood estimation without the need for correction factors or frequency domain analysis of the output residuals. The technique was applied to flight test data from repeated maneuvers flown on the F-18 High Alpha Research Vehicle. As in the simulated cases, parameter accuracy measures from the new technique were in agreement with the scatter in the parameter estimates from repeated maneuvers, whereas conventional parameter accuracy measures were optimistic.

Morelli, Eugene A.↗

Entropy Splitting for High Order Numerical Simulation of Compressible Turbulence

A stable high-order numerical scheme for direct numerical simulation (DNS) of shock-free compressible turbulence is presented. The method is applicable to general geometries. It contains no upwinding, artificial dissipation, or filtering. Instead the method relies on the stabilizing mechanisms of an appropriate conditioning of the governing equations and the use of compatible spatial difference operators for the interior points (interior scheme) as well as the boundary points (boundary scheme). An entropy-splitting approach splits the inviscid flux derivatives into conservative and nonconservative portions. The spatial difference operators satisfy a summation-by-parts condition, leading to a stable scheme (combined interior and boundary schemes) for the initial boundary value problem using a generalized energy estimate. A Laplacian formulation of the viscous and heat conduction terms on the right hand side of the Navier–Stokes equations is used to ensure that any tendency to odd–even decoupling associated with central schemes can be countered by the fluid viscosity. The resulting methods are able to minimize the spurious high-frequency oscillations associated with pure central schemes, especially for long time integration applications such as DNS. For validation purposes, the methods are tested in a DNS of compressible turbulent plane channel flow at low values of friction Mach number, where reference turbulence data bases exist. It is demonstrated that the methods are robust in terms of grid resolution, and in good agreement with published channel data. Accurate turbulence statistics can be obtained with moderate grid sizes. Stability limits on the range of the splitting parameter are determined from numerical tests.

N.D. Sandham↗

Electromagnetic Interference to Flight Navigation and Communication Systems: New Strategies in the Age of Wireless

Electromagnetic interference (EMI) promises to be an ever-evolving concern for flight electronic systems. This paper introduces EMI and identifies its impact upon civil aviation radio systems. New wireless services, like mobile phones, text messaging, email, web browsing, radio frequency identification (RFID), and mobile audio/video services are now being introduced into passenger airplanes. FCC and FAA rules governing the use of mobile phones and other portable electronic devices (PEDs) on board airplanes are presented along with a perspective of how these rules are now being rewritten to better facilitate in-flight wireless services. This paper provides a comprehensive overview of NASA cooperative research with the FAA, RTCA, airlines and universities to obtain laboratory radiated emission data for numerous PED types, aircraft radio frequency (RF) coupling measurements, estimated aircraft radio interference thresholds, and direct-effects EMI testing. These elements are combined together to provide high-confidence answers regarding the EMI potential of new wireless products being used on passenger airplanes. This paper presents a vision for harmonizing new wireless services with aeronautical radio services by detecting, assessing, controlling and mitigating the effects of EMI.

Ely, Jay J.↗

Sensory Bias Predicts Postural Stability, Anxiety, and Cognitive Performance in Healthy Adults Walking in Novel Discordant Conditions

We designed a gait training study that presented combinations of visual flow and support surface manipulations to investigate the response of healthy adults to novel discordant sensorimotor conditions. We aimed to determine whether a relationship existed between subjects visual dependence and their scores on a collective measure of anxiety, cognition, and postural stability in a new discordant environment presented at the conclusion of training (Transfer Test). A treadmill was mounted to a motion base platform positioned 2 m behind a large visual screen. Training consisted of three walking sessions, each within a week of the previous visit, that presented four 5-minute exposures to various combinations of support surface and visual scene manipulations, all lateral sinusoids. The conditions were scene translation only, support surface translation only, simultaneous scene and support surface translations in-phase, and simultaneous scene and support surface translations 180 out-of-phase. During the Transfer Test, the trained participants received a 2-minute novel exposure. A visual sinusoidal roll perturbation, with twice the original flow rate, was superimposed on a sinusoidal support surface roll perturbation that was 90 out of phase with the scene. A high correlation existed between normalized torso translation, measured in the scene-only condition at the first visit, and a combined measure of normalized heart rate, stride frequency, and reaction time at the transfer test. Results suggest that visually dependent participants experience decreased postural stability, increased anxiety, and increased reaction times compared to their less visually dependent counterparts when negotiating novel discordant conditions.

Brady, Rachel A.↗

SiC Field Effect Transistor Technology Demonstrating Prolonged Stable Operation at 500 C

While there have been numerous reports of short-term transistor operation at 500 degree C or above, these devices have previously not demonstrated sufficient long-term operational durability at 500 degree C to be considered viable for most envisioned applications. This paper reports the development of Silicone Carbi field effect transistors capable of long-term electrical operation at 500 degree C. A 6H-SiC MESFET was packaged and subjected to continuous electrical operation while residing in a 500 degree C oven in oxidizing air atmosphere for over 2400 hours. The transistor gain, saturation current (IDSS), and on-resistance (RDS) changed by less than 20% from initial values throughout the duration of the biased 500 degree C test. Another high-temperature packaged 6H-SiC MESFET was employed to form a simple one-stage high-temperature low-frequency voltage amplifier. This single-stage common-source amplifier demonstrated stable continuous electrical operation (negligible changes to gain and operating biases) for over 600 hours while residing in a 500 degree C air ambient oven. In both cases, increased leakage from annealing of the Schottky gate-to-channel diode was the dominant transistor degradation mechanism that limited the duration of 500 degree C electrical operation.

Neudeck, Philip G.↗

Modeling of Multi-Loops Related Device Turn-On Overvoltage in 3L-ANPC Converters

The analytical model for the device drain-source turn-on overvoltage in three-level active neutral point clamped (3L-ANPC) converters is established in this paper. Considering the two commutation loops in the converter, the relationship between the overvoltage and the loop inductances is evaluated. The line switching frequency device usually exhibits higher overvoltage, while the high switching frequency device is not strongly influenced by the multiple loops. A 500 kVA 3L-ANPC converter using SiC MOSFETs is tested, and the model is verified with the experimental results.

SiC MOSFET↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. The study findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. These findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. These findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗