Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Design of a Multiphase CO2 Turbine Test Facility

As the energy market continues to evolve with increased renewables, such as solar and wind energy, the need to balance energy demand with its availability has become increasingly more challenging. The country’s aggressive decarbonization goals in the upcoming decades will increase renewable energy market penetration, thus exacerbating the disparity between energy demand and renewable resource availability. Long-duration energy storage technologies, such as pumped thermal energy storage (PTES), are potential solutions to this challenge with high potential round-trip efficiency (RTE), no geological or geographical constraints, and low safety risks. The charge mode of a PTES system operates a heat pump cycle, converting input power to thermal energy in hot and cold reservoirs. Fundamentally, heat pumps are commonly used in daily life, but the operating conditions required by high RTE PTES systems are outside the design experience of these systems. The low-pressure side of the cycle for a supercritical CO2 (sCO2) PTES operates just above the vapor-dome and potentially drives the turbine to expand into the dome, resulting in multiphase operation in the rear stages of the turbine. This paper presents the design of the test facility for an advanced multiphase-tolerant sCO2 turbine for the heat pump of a PTES system. Heat rejection and pressure loss estimations for the multiphase sections of the test loop presented unforeseen challenges.

25 ENERGY STORAGE↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Sorption heat pump and control method

A method operates an absorption heat pump system, specifically the flow of hydronic cooling fluid through the condenser during system start-ups, or when the cooling fluid temperature is low. To minimize the time for an absorption heat pump to reach full cooling or heating capacity, it is desirable for the high side pressure to increase as fast as possible, and the low side pressure to decrease as fast as possible. Since the high side pressure is a function of the temperature of the refrigerant exiting the condenser, if the condenser cooling fluid temperature is low, the corresponding high side pressure will be low, which may not permit adequate working fluid flow rates from the high pressure side of the system to the low pressure side.

Garrabrant, Michael A.↗

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal energy storage composites with preformed expanded graphite matrix and paraffin wax for long-term cycling stability and tailored thermal properties

Harvesting solar energy, preventing hot spots in electronics, transport of temperature-sensitive materials, and capture and repurposing of thermal energy require a latent heat thermal energy storage (TES) system to store/discharge heat repeatedly. For the practical application of phase change material (PCM) composites within TES systems, reliable thermal performance throughout its operational lifetime is essential. Nevertheless, the reliability of thermal conductivity in multi-phase composites over relevant numbers (>10 3 ) of melt/freeze cycles has barely been studied, particularly for composites containing fillers for thermal conductivity enhancement. Here, we introduce a preform-type expanded graphite (EG)/paraffin wax composite possessing highly robust heat transfer and storage properties even after 10,000 melt/freeze cycles. To achieve such excellent reliability, comparative studies on the combined influence of fabrication process, particle size, EG vol%, binder amount, and compaction on both magnitude and robustness of thermal conductivity were undertaken. Our parametric study has yielded a trade-off between thermal conductivity and latent heat. Based on our modeling, 20 vol% EG approaches the case where all EG particles are well-connected thermally while 10 vol% EG is close to loosely connected fillers in the matrix. Thermal conductivity of our paraffin composites containing 20 vol% EG (25.1 W·m -1 ·K -1 ) is highest among other EG/paraffin composites without aligned EG in the literature. After 10,000 thermal cycling, negligible conductivity fading was observed for the 10 vol% EG composite, while reduction in latent heat remained within 10% for all 10, 14, 17 and 20 vol% EG samples. Here we anticipate this work provides insight on suitable recipe for desirable magnitude and robustness of thermal conductivity of EG/paraffin composites.

25 ENERGY STORAGE↗

Measuring thermal diffusivity and gap conductance in uranium nitride and Zircaloy relevant for microreactor applications

Heat transfer across nuclear fuels and structural interfaces is an important factor for evaluating the performance of nuclear power systems. Specifically, heat generated as nuclear fuel fissions must be transported through the cladding material and through the reactor to reach the steam turbine for power generation. As new microreactor designs emerge, maximizing the efficiency of this heat transfer process becomes crucial to make them commercially viable. This article examines thermal diffusivity and gap conductance in uranium nitride (UN) fuel and Zircaloy-4 (Zry4) cladding using light flash analysis (LFA). Thermal diffusivity measurements were made on monolithic UN pellets and Zry4 exposed to carbon at peak operating temperatures of microreactors and show that carbon ingress has a minimal effect on thermal diffusivity when compared with identical materials not exposed to carbon. Evaluation of gap conductance at the UN-Zry4 interface was done using one-dimensional two-layer thermal transport models as a function of applied pressure. Here the results show that increasing pressure on the UN-Zry4 interface leads to gains in gap conductance per unit area in fuel-cladding assemblies at microreactor operating temperatures. While many other variables are expected to influence UN-Zry4 interfacial gap conductance (e.g. contact surface roughness, porosity, localized heating, environmental gas pressure), the work offers a demonstration of using a conventional LFA apparatus to determine this parameter at elevated temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY20 Third Milestone Report for Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Buildings

This report summarizes the developments of an integrated simulation program for enabling simulation, auto-sizing, and optimization of geothermal heat pump systems. This work fulfills the following FY20 third milestone for WBS 2.5.5.3: Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Building.

15 GEOTHERMAL ENERGY↗

Identification and Evaluation of Thermal Transport Components for Integrated Energy Systems

A proper evaluation and selection of component technologies is a critical aspect in the development of Integrated Energy System (IES). This study aims to investigate the key components and associated technologies required to build high-temperature heat transport systems for IES. Of particular interest is the component technologies needed to design and construct IES that combines advanced nuclear reactors with high-temperature industrial processes. This study particularly delved into knowledge base, evaluation metrics, and state-of-the-art commercial technologies, aiming to facilitate the evaluation and selection process of various thermal transport components. In addition, an evaluation process was proposed in order to assist in the optimal selection of the thermal transport components based on the knowledge base and evaluation metrics investigated through this study.

42 ENGINEERING↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of an Out-Of-Pile Experimental Facility to Demonstrate the Feasibility of In Situ Thermal Conductivity Measurements of Nuclear Fuels Under Irradiation

There is substantial merit in quantifying nuclear fuel performance under irradiation. At Oak Ridge National Laboratory (ORNL), the MiniFuel irradiation platform has become the primary test vehicle for conducting separate-effects fuel performance irradiation experiments. The MiniFuel experiment is a passively controlled capsule design deployed in the High Flux Isotope Reactor (HFIR) through which fuel performance data is collected post-irradiation. Separate effects fuels irradiation capabilities are being expanded at ORNL by developing instrumented capsule designs that aim to capture fuel performance phenomena in-situ. One such capsule will specifically target fuel specimen thermal conductivity changes as a function of fuel burnup. Due to the complexity of making this measurement on nuclear fuel in-pile, this paper describes the necessary out-of-pile testing conducted on the thermal conductivity capsule (TCC) design. The measurement is ascertained via a thermopile system with heat transferred unidirectionally through a surrogate fuel specimen sandwiched between two conductive materials. The capsules investigated in this study are representative of the in-pile design, with the primary departure from irradiation conditions being the distribution of heat generation within the capsule. In the out-of-pile experiment, an external heater was used to drive heat through the conductive slug materials and into the specimen. This paper expounds the design of the out-of-pile experimental system and the thermal conductivity measurement technique. Predictive models used to determine the sensitivity of the measurement to variables governing thermal contact conductance between the specimen and slug materials and to predict experimental results are also described. Data from the out-of-pile experiment will be used to validate the readiness of the design for insertion into HFIR for irradiation.

Parker, Trevor [ORNL]↗

Modeling the Winter Heat Conduction Through the Sea Ice System During MOSAiC

Abstract Models struggle to accurately simulate observed sea ice thickness changes, which could be partially due to inadequate representation of thermodynamic processes. We analyzed co‐located winter observations of the Arctic sea ice from the Multidisciplinary Drifting Observatory for the Study of the Arctic Climate for evaluating and improving thermodynamic processes in sea ice models, aiming to enable more accurate predictions of the warming climate system. We model the sea ice and snow heat conduction for observed transects forced by realistic boundary conditions to understand the impact of the non‐resolved meter‐scale snow and sea ice thickness heterogeneity on horizontal heat conduction. Neglecting horizontal processes causes underestimating the conductive heat flux of 10% or more. Furthermore, comparing model results to independent temperature observations reveals a ∼5 K surface temperature overestimation over ice thinner than 1 m, attributed to shortcomings in parameterizing surface turbulent and radiative fluxes rather than the conduction. Assessing the model deficiencies and parameterizing these unresolved processes is required for improved sea ice representation.

Geology↗

Pump-induced motion of an interface between competing orders

In this work, we study the motion of an interface separating two regions with different electronic orders following a short-duration pump that drives the system out of equilibrium. Using a generalized Ginzburg-Landau approach and assuming that the main effect of the nonequilibrium drive is to transiently heat the system we address the question of the direction of interface motion—in other words, which ordered region expands and which contracts after the pump. Our analysis includes the effects of differences in free-energy landscape and in order parameter dynamics and identifies circumstances in which the drive may act to increase the volume associated with the subdominant order, for example when the subdominant order has a second-order free-energy landscape while the dominant order has a first-order one.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement of Closures and Mechanistic Limit Modeling in Sockeye

Several improvements were made to the heat pipe application Sockeye, including implementation of closure relations and a second-order spatial discretization. The closures improvements include a new, flexible closures system, interfacial heat transfer coefficients, wall heat transfer coefficients, vapor pressure drop, and liquid pressure drop. These improvements were tested on three test cases, with results compared to analytic solutions and the legacy heat pipe code HTPIPE.

97 MATHEMATICS AND COMPUTING↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermomechanical Processing of Uranium Alloys with 10 and 50 Weight Percent Zirconium

This work focuses on casting and thermomechanical processing for moderate sized (500-1000g) 10% by weight and 50% by weight uranium-zirconium alloys. Three castings of uranium – 10wt% zirconium and a fourth casting of uranium – 50wt% zirconium were completed using different castings processes. The first casting process relied on only induction mixing within the VIM system thereby eliminating the need for an arc-melting feedstock preparation step. The second casting process used the arc-melting process prior for feedstock to the same VIM system. In this study, the induction mixing process alone with a graphite crucible appears insufficient for the fabrication of UZr alloys. Graphite is suitable with the use of master alloy UZr feedstock produced by arc-melting. There was a moderate increase of approximately 100 ppm of carbon within the U10Zr alloys. However, there was a near 1000 ppm increase of carbon in the U50Zr alloy. This carbon content is considered too high for forming processes, and therefore, warrants the use of a ceramic crucible for UZr castings near 50wt% zirconium. Zirconia does not appear suitable for UZr castings near 50wt% zirconium. The use of Beryllia or Thoria may be a more suitable option. However, due to the significantly lower liquidus and lower zirconium content, Zirconia crucibles do appear viable for carbon reduction in the U10Zr system. Two thermomechanical processes are also studied in this work - hot extrusion of the U50Zr system and heat treatment in an argon atmosphere. This work demonstrated that extrusion of the U50Zr alloy near 680°C is a viable choice even with +1000 ppm carbon. Extrusion of the U50Zr system near 630°C was unsuccessful and does not appear viable unless significant force and tooling strength is available. There appears to be a moderate increase in extrudate hardness when compared to as-cast. Heat-treatment reduced the hardness of as-cast alloys in the U10Zr castings as well as resolve some variance in the microstructures. However, for the U50Zr billet that did not successfully extrude at 630°C, heat treatment at 900°C for 96 hours did not have a significant impact on hardness or microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗