Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

I/O performance studies of analysis workloads on production and dedicated resources at CERN

The recent evolutions of the analysis frameworks and physics data formats of the LHC experiments provide the opportunity of using central analysis facilities with a strong focus on interactivity and short turnaround times, to complement the more common distributed analysis on the Grid. In order to plan for such facilities, it is essential to know in detail the performance of the combination of a given analysis framework, of a specific analysis and of the installed computing and storage resources. This contribution describes performance studies performed at CERN, using the EOS disk-based storage, either directly or through an XCache instance, from both batch resources and highperformance compute nodes which could be used to build an analysis facility. A variety of benchmarks, both synthetic and based on real-world physics analyses and their corresponding input datasets, are utilized. In particular, the RNTuple format from the ROOT project is put to the test and compared to the latest version of the TTree format, and the impact of caches is assessed. In addition, we assessed the difference in performance between the use of storage system specific protocols, like XRootd, and FUSE. The results of this study are intended to be a valuable input in the design of analysis facilities, at CERN and elsewhere.

Sciabà, Andrea↗

Grid Strength Assessment for High Levels of Inverter-based Resources in the Puerto Rico Power

A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.

inverter based resources, PR100, grid strength↗

Survey and Gap Prioritization of U.S. Electric Vehicle Charge Management Deployments

The goal of this study was to survey and characterize the scope of current technical and programmatic knowledge pertaining to EV charge management technologies and practices in the US and relevant international jurisdictions. This characterization of existing field demonstrations and knowledge derived were used to determine gaps in the SCM demonstration landscape. Addressing these gaps through research and demonstration could increase confidence in the U.S. that load management and EV charge control could achieve overarching societal benefits. A survey of charge management deployments and input from stakeholders was completed to determine the state-of-the-art of smart charge management (SCM) where SCM is defined as controlling the amount of power exchanged between chargers and EVs to meet customers' charging needs while also responding to external power demand or pricing signals to provide load management, resilience, or other benefits to the customer and electric grid. The survey was the basis of the gap analysis in this report and determines which areas are well understood, with high confidence, and which areas need further investigation. Existing examples of EV charge management are characterized here to determine aspects that are ready for widespread deployment and have been demonstrated in the field. These include demonstration studies, pilots, programs, and EV-specific tariffs. In all, 110 examples of charge management were characterized. The data sources were public literature and utility filings as well as targeted interviews. In addition, 43 interviews with stakeholders were conducted with a consistent set of questions used in each interview. This study prioritized gaps in demonstrated SCM capabilities based on 1) Urgency of the particular use-case to offset traditional grid assets, 2) Impact, extensibility, and scaling of results across the entire spectrum of 3000+ utility service territories including projected technical and market potential for a given grid service, and 3) Value of federal funding in addressing the gap, including potential to leverage and/or add scope to existing field demonstrations funded by other non-federal funding mechanisms.

33 ADVANCED PROPULSION SYSTEMS↗

DC Microgrids Under Denial of Service Attacks: Feasibility and Stability Issues

Distributed control has been extensively studied for a DC microgrid to coordinate multiple grid assets where each asset can generate its own control decisions based on communications within its neighborhood. Nevertheless, such a control strategy usually has a strong dependence on active information exchange and needs to always maintain a pre-determined communication graph. This makes it vulnerable to cyber attacks, especially denial of service (DoS) attacks that block communication channels that effectively change the communication graph. In this paper, we study two potential impacts of DoS attacks: the inability to maintain steady-state and dynamical generation-demand balance, i.e. the feasibility and stability issues. We develop a mathematical model to describe the cyber-induced system steady-state and dynamical performance. The model reveals the impacts of DoS attacks and enables formal analysis. Case studies are shown to verify the proposed work.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analysis of Loss-of-Offsite-Power Events: Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2020, while the most recent 15-year data (i.e., from 2006–2020) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather related. Highly significant decreasing trends in the LOOP occurrence rates were identified for All-LOOPs during critical operation (p-value = 0.001) and switchyard-centered LOOPs during critical operation (p-value = 0.002) for the most recent 10-year period (2011–2020). Adverse trends in LOOP durations continue for switchyard-centered LOOPs (p-value = 0.005), All-LOOPs (p-value = 0.019), as well as All-LOOPs during shutdown operation (p-value = 0.003). Statistical tests show the LOOP counts are not uniformly distributed across the 12 months, and variation among the months exists for plant-centered LOOPs (p-value = 0.028), grid-related LOOPs (p-value = 0.021), All-LOOPs (p-value = 0.003), and All-LOOPs during critical operation (p-value = 0.008). The engineering analysis of LOOP data showed for the period of 2006–2020, the equipment failure events were dominated by failures of circuits and relay; human errors have been less frequent and occurred primarily in maintenance; and weather events were dominated by tornadoes and lightning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Electric Medium- and Heavy-Duty Vehicle Charging Infrastructure Attributes and Development

Although more established for light-duty vehicles (LDVs), advancements in electric vehicle (EV) charging technology are being made in the medium- and heavy-duty (MD/HD) sector. Progress is also being made with the electrification of MD/HD vehicles, including transit buses, school buses, MD trucks, and HD trucks. The diverse set of operational requirements and duty cycles for each vocation, as well as the range in the size of fleets, present unique charging and infrastructure requirements. This report focuses on charging requirements for MD/HD vehicles and synergies with LDV infrastructure. This analysis leans toward the qualitative rather than quantitative because relevant model inputs are in development and will not be established for a few years, as EV deployments are more mature in the LDV sectors than MD/HD. The report begins with an overview of MD/HD vehicle classes and types of charging, including depot and residential charging, among others (Section 2). Section 3 analyzes the home bases (overnight dwell locations) of existing MD/HD vehicles, with an emphasis on depot and residential home bases, and discusses implications for charging infrastructure. Section 4 discusses the key characteristics for determining if, when, and where MD/HD vehicles can leverage LDV charging infrastructure rather than requiring dedicated chargers. These considerations include electricity demand, connectors, physical space requirements, payment considerations, and impacts on the grid. Section 5 summarizes shared characteristics for MD/HD vehicles that are appropriate for near-term electrification and includes a summary of the outlook of the electric MD/HD vehicle market. The conclusion (Section 6) summarizes the report's findings and outlines areas for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced Models for Chemical Kinetics derived from Parallel Ensemble Simulations of Stirred Reactors

Detailed chemical kinetic models are essential to improve the predictive capability of computational fluid dynamics (CFD) simulations and to impact the development of next generation combustion technologies. However, such detailed kinetic models are beyond the reach of CFD codes due to the computational cost of transporting additional chemical degrees of freedom. Reduced order models for combustion kinetics exploit the presence of lower dimensional manifolds in the state space and require far fewer number of scalars to be transported as part of CFD simulations. In this paper, we describe the software infrastructure developed to allow large ensembles of stirred reactor configurations with detailed chemical kinetics. The canonical reactor simulations are incorporated in a workflow with sparse grid and data reduction methodologies aimed at development of reduced order models. We present results from analyzing the results of the stirred reactor calculations for syngas mixture using principal component analysis (PCA) and neural network methodologies. The results show that nonlinear autoencoder model can surpass PCA in representing the original dataset with far fewer degrees of freedom.

Zhang, Pei↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Final Technical Report of a Feasibility Investigation of a Hydropower Flexibility Upgrade Kit

The project studied the feasibility of a concept for a flexibility upgrade kit called h-Dynamyk to improve the flexibility of U.S. hydropower plants and assessed its potential impact on the U.S. hydropower industry. This concept addresses the growing need for grid flexibility amid rising renewable energy adoption, such as wind and solar, which often introduce intermittency. The upgrade kit is intended to address challenges posed by aging turbine designs in meeting modern grid demands for flexibility services like frequency response, voltage control, spinning reserve, and black-start capabilities. Key features of the h-Dynamyk kit include siphon turbine assemblies, medium-voltage variable frequency drives (VFDs), and smart controls integrated with plant systems to optimize operations and extend equipment life. This nine-month discovery project successfully achieved its objectives by defining a baseline design and performance metrics for the h-Dynamyk flexibility upgrade kit, analyzing this baseline, and incorporating lessons learned from this analysis into a modified set of metrics and recommendations for future design and testing, which were further guided by field site studies.

13 HYDRO ENERGY↗

A Multi-Model Framework for Assessing Long- and Short-Term Climate Influences on the Electric Grid

Climate change influences many aspects of the electric grid, but prior work and industry practices often ignore the potential effects of changing climate, or they only consider a single effect or individual effects in isolation. Challenges vary with each grid and include adapting to long-term trends such as changing temperature and precipitation or shorter-term events such as drought or storms that could increase in frequency or intensity. Here we present a multi-model framework designed to analyze the effects of long and short-term climate impacts in combination. This framework couples capacity expansion and production cost models with hydrologic models and future climate scenario data to analyze alternative climate and energy futures at high spatial, temporal, and process resolutions. Furthermore, we constructed and evaluated the results of a suite of simulated scenarios exploring climate impacts on capacity investment and stress-tested the resulting future infrastructures using hourly dispatch modeling under alternative drought and load conditions. We demonstrate the approach through a case study of the U.S. Western Interconnection, where climate impacts depend on interactions between temperature-induced load, water availability for hydropower, technology competitiveness, and demand flexibility. Changes in 2038 generating capacity range from -8.5-16.6 GW, and changes in 2038 transmission capacity range from -1-2 GW. Capacity increases are driven by higher load from higher temperatures, while capacity reductions can be achieved in scenarios with higher future hydropower availability and increased demand flexibility. Scenarios requiring additional capacity cost an additional $\$5$-$\$17$ billion (discounted) from 2018 to 2038; however, scenarios with capacity reductions cost $\$1$-$\$18$ billion less. Stress tests on four 2038 infrastructures demonstrated that the identified systems were able to serve at least 99.999% of load and 99.96% of reserves. However, drought and unexpected high-load conditions can result in reduced capacity to respond to contingency events we did not model. Although these results are system and scenario specific, they highlight the importance of considering multiple climate change impacts simultaneously in long-term planning efforts and demonstrate a multi-model, multiscale approach that can be flexibly applied to any system and set of climate change concerns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic and Deployment Analysis of Fossil Fuel-Based Power Generation with Integrated Energy Storage

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenues. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation such as wind and solar is shifting traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. The recent studies have shown that flexibility of a coal-fired power plant can be improved by the energy storage. The objective of this project was to analyze a set of energy storage options (technologies) and determine their impact on flexibility and economics of a representative coal-fired power plant. The effect of five Energy Storage Systems (ESSs) integrated with a coal power plant on plant flexibility and economics was investigated in this study. The results obtained in this project and presented in this report showed that ESS integrated with a thermal power plant improves plant flexibility and participation in the Energy and Ancillary Services markets and also improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Efficient Contingency Analysis in Power Systems via Network Trigger Nodes

Modeling failure dynamics within a power system is a complex and challenging process due to multiple inter-dependencies and convoluted inter-domain relationships. Subject matter experts (SMEs) are interested in understanding these failure dynamics for reducing the impact from future disasters (i.e., losses or failures of power system components, such as transmission lines). Contingency analysis (CA) tools enable such ’what-if’ scenario analyses to evaluate the impacts on the power system. Analyzing all possible contingencies among N system components can be computationally expensive. An important step for performing CA is identifying a set of k ‘trigger’ components, which when failed initially can significantly impact the overall system by causing multiple failures. Currently SMEs focus on identifying these trigger components by running expensive simulations on all possible subsets, which quickly becomes infeasible. Hence finding a relevant set of trigger components (contingencies) rapidly to enable efficient and useful CA is crucial.In a collaboration between computer scientists and power system experts, we propose an efficient method for performing CA by exploiting network inter-dependencies in power system components. First, we construct a network with multiple electric grid infrastructure components and dependencies as connections among them. We reformulate the problem of finding a set of trigger components as a problem of identifying critical nodes in the network, which can cascade power failures through connected nodes and cause significant damage to the network. To guide the practical CA tools, we develop a network-based model with a probabilistic edge-weights setup using intricate domain rules. Then we conduct an empirical study on real power system data in the US for both regional and national levels. Firstly, we use power system datasets for the US to create a national-scale domain-driven model. Secondly, we demonstrate that network-based model outperforms the outputs from a real CA tool and show on average 25 × improved selection of contingencies, thereby showcasing practical benefits to the power experts.

Tabassum, Anika↗

Hydrological analysis in watersheds with a variable-resolution global climate model (VR-CESM)

Traditionally, watershed-scale hydrology is simulated by distributed hydrological models with offline meteorological forcing data, or by regional regional climate models that link atmospheric and land hydrology interactions. Global climate models (GCMs) are rarely used to study watershed-scale hydrology due to the relatively coarse grid resolution, computationally expensive downscaling, and simplified physical processes. Recently, however, watershed-scale hydrology analysis has become possible in GCMs due to the development of variable-resolution GCMs that dynamically couple the hydrological processes between atmosphere and land systems at fine resolutions in selected regions and coarse resolution elsewhere. In this study, we used the variable-resolution Community Earth System Model (VR-CESM) with refined-resolution (14 km) in the western U.S. and eastern China to evaluate watershed-scale hydrology. Furthermore, we compared the historical VR-CESM outputs with gauge measurements and other hydrological models (e.g., National Water Model in the U.S.) and calibrated the subsurface runoff capacities in four mountainous watersheds. An RCP8.5 projection from 2007 to 2050 is used to estimate the impact of changing precipitation and snow climatology on watershed hydrology. We also analyzed the long-term runoff variability and the possibility of extreme runoff events as simulated by the VR-CESM. Although calibration is not possible in larger-scale watersheds, VR-CESM simulates the long-term annual variability of watersheds and provides insights on climate change impacts on hydrology. We conclude that refined-resolution VR-CESM can be used for watershed-scale hydrology analysis to understand water resources and water balance, in addition to traditional watershed-scale hydrological models. It enables hydrological analysis at multiple watersheds in one simulation and can help understand the two-way dynamics between land surface hydrology and atmospheric processes, and is especially practical for projecting climate change impacts. However, it is challenging to apply VR-CESM for hydrologic analysis in regulated watersheds as human factors (e.g., pumping, irrigation, water diversion) have not been fully addressed in VR-CESM.

54 ENVIRONMENTAL SCIENCES↗

An Investigation into the Effects of Swirl on the Performance and Emissions of an Opposed-Piston Two-Stroke Engine using Large Eddy Simulations

Opposed-piston two-stroke (OP-2S) engines have the potential to achieve higher thermal efficiency than a conventional four-stroke diesel engine. However, the uniflow scavenging process is difficult to control over a wider range of speed and loads due to its sensitivity to pressure dynamics, port timings, and port design. Specifically, the angle of the intake ports can be used to generate swirl which has implications for open and closed cycle effects. This study proposes an analysis of the effects of port angle on the in-cylinder flow distribution and combustion performance of an OP-2S using computational fluid dynamics engine. Large Eddy Simulation (LES) was used to model turbulence given its ability to predict in-cylinder mixing and cyclic variability. A three-cylinder model was validated to experimental data collected by Achates Power and the grid was verified using an LES quality approach from the literature. The model was used to simulate port angles from 12 to 29 degrees at constant pressure and temperature boundary conditions. Results indicated that the higher bulk swirl ratio generated by larger port angles tends to trap more internal residuals. This effect on the scavenging performance, combined with the larger trapped swirl ratio, also has a significant impact on the combustion performance in a two-stroke engine. It was concluded that there exists a tradeoff of efficiency and emissions that must be considered when increasing the port angle in a uniflow two-stroke engine. 1. Introduction Two-stroke engines were developed in the 1800s and are commonly used in practice today for lightweight power applications such as motorcycles or handheld power tools, as well as large-bore low speed engines for stationary power and marine applications. Two-stroke engines provide the distinct advantage of higher torque/power output but present challenges due to its coupled intake and exhaust process. Four-stroke engines have the benefit of using two full piston strokes to induct intake charge and to expel exhaust gases. Controlling the trapped charge composition in a twostroke engine via a scavenging process is crucial for reliable and efficient engine operation.

33 ADVANCED PROPULSION SYSTEMS↗