Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

(abstract) A Relativistically Expanding Radio Source Associated with GRO J1655-40

GRO J1655-40 was discovered as a new, bright X-ray source with the BATSE detector of the Gamma Ray Observatory (GRO) on July 27, 1994. During the subsequent radio outburst we completed VLBI synthesis imaging observations at a frequency of 2.29 GHz. An unprecedented angular motion of 65+/- mas per day was reported between two components of complex and disparate morphology ?? The separation rate indicates that the two components were at zero separation near the onset of the radio flare. Similar to the recently reported GRS 1915+105, it seems that the motion of material ejected from a stellar mass compact object with at least a mildly relativistic velocity may explain the observed radio structural changes in GRO J1655-40. The two-week delay between the X-ray outburst and the production of radio components may indicate that the X-rays were produced by a super-critical accretion process onto the compact member of this stellar binary system. This process inhibited or smothered the ejection of radio components until the accretion disk stabilized.

X-ray sources Gamma Ray Observatory GRO radio outb↗

The Swift Gamma-ray Burst Explorer: Early Views into Black-hole Creation

This viewgraph presentation reviews the discovery of Gamma-ray Bursts (GRBs) in the 1960's and early 1970's, and the characteristics of GRBs. Theoretical predictions and explanations are reviewed. The first observation of a GRB by the Beppo-SAX is discussed, and then the need develop a Gamma Ray Burst detector with a larger field of view, that has rapid follow-up capabilities and has the ability to rapidly get localized positions to the ground. The Swift instruments (i.e., the Burst Alert Telescope (BAT), the X-Ray Telescope (XRT) and the UV/Optical Telescope (UVOT)) are shown and described. The scenario for observing of GRBs is reviewed. Many charts of the some of the GRBs data and GRB spectra are shown.

Hill, Joe↗

Codoping method for modifying the scintillation and optical properties of garnet-type scintillators

A method of tailoring the properties of garnet-type scintillators to meet the particular needs of different applications is described. More particularly, codoping scintillators, such as Gd 3 Ga 3 Al 2 O 12 , Gd 3 Ga 2 Al 3 O 12 , or other rare earth gallium aluminum garnets, with different ions can modify the scintillation light yield, decay time, rise time, energy resolution, proportionality, and/or sensitivity to light exposure. Also provided are the codoped garnet-type scintillators themselves, radiation detectors and related devices comprising the codoped garnet-type scintillators, and methods of using the radiation detectors to detect gamma rays, X-rays, cosmic rays, and particles having an energy of 1 keV or greater.

Tyagi, Mohit↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube

A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.

Timothy, J. G.↗

PING Gamma Ray and Neutron Measurements of a Meter-Sized Carbonaceous Asteroid Analog

Determining the elemental composition of carbonaceous (spectral type C) asteroids is still one of the basic problems when studying these objects. The only main source of elemental composition information for asteroids is from their optical, NIR and IR properties, which include their spectral reflectance characteristics, albedo, polarization, and the comparison of optical spectroscopy with meteorite groups corresponding to asteroids of every spectral type. Unfortunately, these sources reflect observations from widely contrasting spatial scales that presently yield a void in the continuum of microscopic and macroscopic evidence, a lack of in situ measurement confirmation, and require deeper sensing techniques to discern the nature of these asteroids. The Probing In situ with Neutrons and Gamma rays (PING) instrument is ideally suited to address this problem because it can be used to determine the bulk elemental composition, H and C content, the average atomic weight and density of the surface and subsurface layers of C-type asteroids, and can provide measurements used to determine the difference between and distinguish between different types of asteroids. We are currently developing the PING instrument that combines gamma ray and neutron detectors with a 14 Me V pulsed neutron generator to determine the in-situ bulk elemental abundances and geochemistry of C-type asteroids with a spatial resolution of 1 m down to depths of tens of cm to 1 m. One aspect of the current work includes experimentally testing and optimizing PING on a known meter-sized Columbia River basalt C-type asteroid analog sample that has a similar composition and the same neutron response as that of a C-type asteroid. An important part of this effort focuses on utilizing timing measurements to isolate gamma rays produced by neutron inelastic scattering, neutron capture and delayed activation processes. Separating the gamma ray spectra by nuclear processes results in higher precision and sensitivity elemental composition measurements. Using gated data acquisition techniques allows for the unambiguous identification of gamma ray lines from different isotopes and nuclear processes, especially in situations when limited detector resolution results in overlapping gamma ray lines that cannot be individually resolved. In this paper, we will present the PING basalt layering experimental data, taken at the test facility at NASA Goddard Space Flight Center using the time tagged event-by-event data analysis technique, compared to our MCNPX computer simulation results for the C-type asteroid and basalt layering simulant models. Comparison of these data will show the advantages, validity, and measurement sensitivity of PING's nuclear interrogation methods to obtain more precise and sensitive in situ bulk elemental composition and density measurements of the subsurface of asteroids.

Bodnarik, J.↗

Fast neutron activation of ubiquitous materials

Nuclear explosions expose ubiquitous materials to large numbers of neutrons, producing a variety of radioactive isotopes. To simulate such phenomena from both fission and thermonuclear explosions, we irradiated 29 different targets with approximately 3 and 14 MeV neutrons and measured the beta-delayed gamma rays using germanium detectors. Therefore, for each neutron energy, the expected radioisotopes, half-lives, and gamma ray energies were deduced. From measurements of the ratios of activities of the radionuclides produced by neutron irradiations, we were able to identify several materials that are particularly sensitive to the neutron energy spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

RPC based tracking system at CERN GIF++ facility

With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy spectral breaks in gamma-ray bursts

Model fits are presented for 18 gamma-ray burst spectra from 100 keV to 27 MeV made with the BATSE spectroscopy detectors on the Compton Gamma Ray Observatory. Most of the bursts are well fitted as power laws with spectral indices between -1.36 and -2.29; however, five bursts show definite departures from a simple power-law fit at high energies. Three of these bursts are well fitted with broken power-law spectra and break energies of from 400 to 690 keV, such as might arise from photon-photon interactions. If so, then the source compactness and hence distance will be sharply constrained. Two of the bursts have spectra with sharply confined slope changes and are well fitted with broken power-law spectra with break energies of 1.2 and 1.6 MeV at peak, such as might arise from photon-magnetic field interactions. If so, then these spectral breaks provide strong evidence for the existence of high magnetic fields in the burst emission region.

Schaefer, Bradley E.↗

Background estimation in a (gnu e)-diffusion detector

Background conditions for detecting (gamma e)-diffusion are discussed with reference to the utilization of a hodoscope system consisting of wide area flat Geiger counters connected for coincidence and of a controllable spark chamber. When calculating the background, any organic compounds synthesized from C, O2 and H2 with radioactive admixtures is presumed to be the preferrable material for the construction of the detector. The number of background events simulating the effect sought is estimated by analyzing the spectrum of the organic glass gamma radiation caused by disintegration and fission of long lived isotopes and by nuclear reactions with the participation of alpha particles and neutrons.

Glotov, V. I.↗

Multi-Line Gamma-Ray Spectrometer Performance of a Si(Li) Detector Stack

Experimental data is presented which for the first time displays multi-line spectrometer performance of a Si(Li) detector stack at elevated temperature. The stack consists of four elements, each with a 2 cm diameter active area. Ba-133 and Ag-110m spectra are obtained using various techniques to enhance the peak-to-background ratio. Spectral data are shown as a function of temperature (94 K less than or equal to T less than or equal to 230 K) using optimized peak shaping.

Hubbard, G. Scott↗

Multi-Line Gamma-Ray Spectrometer Performance of a Si(Li) Detector Stack

Experimental data is presented which for the first time displays multi-line spectrometer performance of a Si(Li) detector stack at elevated temperature. The stack consists of four elements, each with a 2 cm diameter active area. Ba-133 and Ag-110m spectra are obtained using various techniques to enhance the peak-to-background ratio. Spectral data are shown as a function of temperature (94 K less than or = T less than or = 230 K) using optimized peak shaping.

Hubbard, G. Scott↗

Spectral evolution of gamma-ray bursts

BATSE's Spectral Detectors provide a series of high resolution spectra over the duration of a gamma-ray burst; fits to these spectra show the evolution of the continuum as the burst progresses. The burst continuum can usually be fit by the spectral form AE sup alpha exp(-E/kT) from around 25 keV to more than 3 MeV, with varying trends in the value and evolution of the spectral parameters. As a result of limited statistics for E greater than 1 - 2 MeV in the individual spectra, a high energy power law is not required. Only long duration strong bursts can be studied by fitting a series of spectra, and therefore our conclusions concern only this class of burst. The bursts we analyzed tend to be characterized by a hard-to-soft trend both for individual intensity spikes and for the burst as a whole: the hardness leads the count rate in spectra which resolve the temporal variations, while the hardness of successive spikes decreases. We also summarize the performance of the Spectral Detectors and the development of analysis tools to date.

Band, D.↗