Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

New Whole-House Solutions Case Study: Schneider Homes, Inc.

Schneider Homes cut energy use by 50% over the 2004 IECC on 28 homes built near Seattle in 2008. Schneider packed the walls with R-23 of blown fiberglass and blanketed the ceiling with R-38 of blown cellulose. Ducts went into conditioned space through open-web floor trusses between floors and air handlers went into an air sealed garage closet.

blown cellulose↗

Modeling of Stress Distribution in Molten Salt Thermal Energy Storage Tanks for In-Service Central Receiver Power Plants

Failures in molten nitrate salts thermal energy storage tanks (TES) have been occurring in several concentrating solar power (CSP) plants around the world after a few months or years of operation. These failures are mainly related to a combination of high stress, corrosion, large deformation, and thermal cycling. Most of these failures are a consequence of the infancy of this technology; technical standards for design, fabrication, implementation, and operation of molten salt tanks operating at temperatures up to 565 degrees Celsius do not exist and most of current in-service tanks have been designed using the recommendations from the American Petroleum Institute (API) 650 and the American Society of Mechanical Engineers ASME section II standards, which are applicable for TES tanks operating at lower temperatures. We have developed a 3-dimensional model of a representative molten salt hot tank design that uses typical CSP plant operation conditions and allows determining the temperature and stress distribution in the tank. The model also considers the initial floor residual stresses and distortion after its welding fabrication. We have identified critical thermal gradients in the tank floor and shell and locations in the tank where the stresses are high and could become susceptible points for failure.

concentrating solar power↗

Digital Autoradiography as a novel complementary technique for the investigation of radioactive contamination in nuclear facilities under dismantlement

The detection (location and quantification) of nuclear facilities to be dismantled possible contamination with low-range particles emitters ({sup 3}H, other low-energy β emitters, a emitters) remains a tedious and expensive task. Indeed, usual remote counters show a too low sensitivity to these non-penetrating radiations, while conventional wipe tests are irrelevant for fixed radioactivity evaluation. The only method to accurately measure activity levels consists in sampling and running advanced laboratory analyses (spectroscopy, liquid scintillation counting, pyrolysis...). Such measurements generally induce sample preparation, waste production (destructive analyses, solvents), nuclear material transportation, long durations, and significant labor mobilization. Therefore, the search for the limitation of their number and cost easily conflicts with the necessity to perform a dense screening for sampling (to maximize the representativeness of the samples), in installations of thousands of square meters (floors, wells, ceilings), plus furniture, pipes, and other wastes. To overcome this contradiction, Digital Autoradiography (D. A.) was re-routed from bio molecular research to radiological mapping of nuclear installations under dismantling and to waste and sample analysis. After in-situ exposure to the possibly-contaminated areas to investigate, commercial reusable radiosensitive phosphor screens (of a few 100 cm{sup 2}) were scanned in the proper laboratory device and sharp quantitative images of the radioactivity could be obtained. The implementation of geostatistical tools in the data processing software enabled the exhaustive characterization of concrete floors at a rate of 2 weeks / 100 m{sup 2}, at lowest costs. Various samples such as drilled cores, or tank and wood pieces, were also successfully evaluated with this method, for decisive results. Thanks to the accurate location of potential contamination spots, this approach ensures relevant and representative sampling for further laboratory analyses and should be inserted in the range of common tools used in dismantling. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Application of collimated spectrometric systems for the characterization of radioactive contamination of decommissioned facilities - 15030

Different approaches use collimated spectrometric systems for the characterization of radioactive contamination of various objects: soil, constructions decommissioned facilities. From time of works on elimination of Chernobyl accident and other large scale contamination accidents due radioactive dawn-falls we start to use 'CORAD' method which gives values of surface contamination of soil (in Ci/m{sup 2}) and depth of soil contamination (in MFP or cm) using measurements with collimated spectrometric detector NaI(Tl). The realizations of method for measuring of surface contamination of walls, floors using spectrometric detectors of various types were carried out in last years. We present the main results of the work - the upgraded detector for measuring contamination in wells and concrete measurements in contaminated areas of engineering rooms. Realization of method using different types of spectrometric detectors scintillating NaI(Tl) and LaBr{sub 3}, semiconductor - HPGe and room temperature CdZnTe. Different types of detector are the most suitable for different conditions of measurements. The results of measurements of contaminated soil, sediment, concrete construction floor and walls in the rooms are presented. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Anthropogenic N deposition increases soil C storage by reducing the relative abundance of lignolytic fungi

Abstract Atmospheric nitrogen (N) deposition has increased dramatically since preindustrial times and continues to increase across many regions of the Earth. In temperate forests, this agent of global change has increased soil carbon (C) storage, but the mechanisms underlying this response are not understood. One long‐standing hypothesis proposed to explain the accumulation of soil C proposes that higher inorganic N availability may suppress both the activity and abundance of fungi that decay lignin and other polyphenols in soil. In field studies, elevated rates of N deposition have reduced the activity of enzymes mediating lignin decay, but a decline in the abundance of lignolytic fungi has not been definitively documented to date. Here, we tested the hypothesis that elevated rates of anthropogenic N deposition reduce the abundance of lignolytic fungi. We conducted a field experiment in which we compared fungal communities colonizing low‐lignin, high‐lignin, and wood substrates in a northern hardwood forest that is part of a long‐term N deposition experiment. We reasoned that if lignolytic fungi decline under experimental N deposition, this effect should be most evident among fungi colonizing high‐lignin and wood substrates. Using molecular approaches, we provide evidence that anthropogenic N deposition reduces the relative abundance of lignolytic fungi on both wood and a high‐lignin substrate. Furthermore, experimental N deposition increased total fungal abundance on a low‐lignin substrate, reduced fungal abundance on wood, and had no significant effect on fungal abundance on a high‐lignin substrate. We simultaneously examined these responses in the surrounding soil and forest floor, in which we did not observe significant reductions in the relative abundance of lignolytic fungi or in the size of the fungal community; however, we did detect a change in community composition in the forest floor that appears to be driven by a shift away from lignolytic fungi and towards cellulolytic fungi. Our results provide direct evidence that reductions in the abundance of lignolytic fungi are part of the mechanism by which anthropogenic N deposition increases soil C storage.

Entwistle, Elizabeth M.↗

Probing eddy size and its effective mixing length in stably stratified roughness sublayer flows

Stably stratified roughness sublayer flows are ubiquitous yet remain difficult to represent in models and to interpret using field experiments. Here, continuous high-frequency potential temperature profiles from the forest floor up to 6.5 times the canopy height observed with distributed temperature sensing (DTS) are used to link eddy topology to roughness sublayer stability correction functions and coupling between air layers within and above the canopy. The experiments are conducted at two forest stands classified as hydrodynamically sparse and dense. Near-continuous profiles of eddy sizes (length scales) and effective mixing lengths for heat are derived from the observed profiles using a novel conditional sampling approach. The approach utilizes potential temperature isoline fluctuations from a statically stable background state. The transport of potential temperature by an observed eddy is assumed to be conserved (adiabatic movement) and we assume that irreversible heat exchange between the eddy and the surrounding background occurs along the (vertical) periphery of the eddy. This assumption is analogous to Prandtl's mixing-length concept, where momentum is transported rapidly vertically and then equilibrated with the local mean velocity gradient. A distinct dependence of the derived length scales on background stratification, height above ground, and canopy characteristics emerges from the observed profiles. Implications of these findings for (1) the failure of Monin–Obukhov similarity in the roughness sublayer and (2) above-canopy flow coupling to the forest floor are examined. The findings have practical applications in terms of analysing similar DTS data sets with the proposed approach, modelling roughness sublayer flows, and interpreting nocturnal eddy covariance measurements above tall forested canopies.

54 ENVIRONMENTAL SCIENCES↗

Using AI Simulations to Dynamically Model Multi-agent Multi-team Energy Systems

The complexity of energy systems is well known as they are complex and intricate systems. As a result, many extant studies have used many simplifications or generalizations that do not accurately reflect the nature of this complex system. In particular, most HVAC systems are modeled as a single unit, or several large units, rather than as a hierarchical composite (e.g., as a floor rather than as a collection of disparate rooms). The net result of this is that the simulations are too generic to perform meaningful analysis, machine learning, or integrated simulation. We propose using a multi-agent multi-team strategic simulations framework called SiMAMT to better define, model, simulate, and learn the HVAC environment. SiMAMT allows us to create distinct models for each type of room, hierarchically aggregate them into units (like floors, or sections), and then into larger sets (like buildings or a campus), and then perform a simulation that interacts with each sub-element individually, the teams of sub-elements collectively, and the entire set in aggregation. Further, and most importantly, we additionally model another ‘team’ within the simulation framework - the users of the systems. Again, each individual is modeled distinctly, aggregated into sub-sets, then collected into large sets. Each user, or agent, is performing on their own but with respect to the larger team goals. This provides a simulation that has a much higher model fidelity and more applicable results that match the real-world.

Franklin, D. Michael↗

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transport and Fate of Natural Gas and Brine Escaping from a Hydrocarbon Reservoir Through a Failed Deepwater Well in the Oceanic Subsurface of the Gulf of Mexico

The possibility of broaching, or the release of fluids at the seafloor due to a damaged or faulty well, is a hazard that must be assessed in the well permitting process. Here, this paper describes a numerical simulation study of a real-life scenario where a complex, permeable sandy formation, connected to the seafloor via known chimneys/seeps, is intersected by a damaged production well that drains another deeper, gas-bearing formation. The objective of the study is to determine the transport and fate of hydrocarbon reservoir fluids (gas and brines) escaping into the sandy formation through the casing shoe of the failed well, and to determine the time it takes for these contaminants to reach the ocean floor. We conducted a detailed simulation study to represent the conditions, properties, and behavior of the system under such failure conditions, and we investigated the migration of gas and brine for a range of reservoir and chimney properties. A key conclusion is that, for such complex systems, modeling the three-dimensional geometry of the system in detail is the key to describing transport and assessing the time and magnitude of potential releases. For the system studied here, transport times range from under 2 years (highest permeabilities) to many decades, ensuring significant time to respond to potential broaching hazards. Lastly, under the conditions investigated in this study, we also determine that gas-dominated releases associated with low rates of water flow into the sandy formation are likely to cause hydrate formation that can reduce permeabilities in the colder, upper regions of the chimneys and possibly mitigate releases.

58 GEOSCIENCES↗

Estimating source-sink distributions and fluxes of reactive nitrogen and sulfur within a mixed forest canopy

The vertical source-sink distribution of air pollutants within and above forested canopies is necessary for describing the biological, physical, and chemical processes influencing the soil-vegetation-atmosphere exchange. Here, this study implemented inverse modeling methods to estimate the source-sink and flux profiles of reactive nitrogen (N) and sulfur (S) compounds from measurements of the mean concentration profiles of ammonia (NH 3 ), nitric acid (HNO 3 ), sulfur dioxide (SO 2 ), and particulate ammonium (NH 4 + ), nitrate (NO 3 − ), and sulfate (SO 4 2− ) at a forest site in the southern Appalachian Mountains. Three inverse approaches utilizing different approximations to scalar transport within the canopy were developed and evaluated against sensible heat flux measurements. The Eulerian model (EUL), which incorporates vertical velocity skewness, performed well in reproducing the turbulent heat fluxes and was subsequently used to calculate the chemical source-sink and flux profiles. Above-canopy fluxes of NH 3 were downward, indicating that the forest was a net sink of NH 3 . The soil/litter layer was both a source and a sink for NH 3 but the exchange rate at the forest floor was small. Fluxes of HNO 3 , SO 2 , NO 3 − , NH 4 + , and SO 4 2- were uni-directional (deposition only) between the air and the canopy/ground and increased monotonically from the forest floor to the canopy top. Crown foliage dominated the uptake of reactive N and S during the growing season, accounting for 80–90% of the total canopy-scale flux. Fluxes and canopy-ground partitioning estimated using the resistance-based Surface Tiled Aerosol and Gas Exchange (STAGE) model were generally comparable to EUL. The comparison highlights the need for improved parameterizations of litter exchange and NH 3 compensation points in resistance models for forest ecosystems. The findings here benefit the application of critical loads in forest ecosystems and guide further development of resistance-based exchange models.

54 ENVIRONMENTAL SCIENCES↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Personal and environmental predictors of polycyclic aromatic hydrocarbon exposure identified through repeated silicone wristband sampling

This study integrates quantitative data on personal exposure to polycyclic aromatic hydrocarbons (PAHs) in 162 silicone wristbands with demographics, behavioral information, and housing characteristics to explore contributions to residential exposure in a superfund-adjacent community over the course of a year. Forty-six residents completed questionnaires and wore silicone wristbands as personal passive samplers for seven consecutive days on up to four separate occasions in alternating months between November 2022 and June 2023. It was hypothesized that individual behaviors and housing characteristics are sources of dependence and correlation between personal PAH exposures. 50 PAHs were detected at least once, 17 of which were alkylated PAHs. Exposure to PAHs of similar molecular weight was often correlated, notably between naphthalenes (2-rings) and higher molecular weight PAHs (3 or more rings). Generalized linear mixed models identified flooring type, participant age, and sampling month as important predictors of increased PAH exposure, and flooring type, and use of wood stoves or heavy machinery as predictors of increased naphthalene exposure relative to higher molecular weight PAHs. Individual chemical models based on concentration data and detection frequencies corroborated these findings across multiple PAHs. We demonstrate that personal exposure is not static and the degree of variability in personal exposure is individual. Hence, identification of influential exposure factors through repeated measures of chemical exposure and characterization of variability in personal exposure as performed in this study, is important in the development of exposure mitigation strategies.

Bonner, Emily↗

Effects of carbon dioxide sequestration on California margin deep-sea foraminiferal assemblages

Abstract Deep-sea sequestration of CO2 is being considered as a possible mitigation tool to decrease atmospheric CO2 concentrations and its associated negative effects. This study investigated potential effects of liquid carbon dioxide (CO2) injection on deep-sea foraminiferal assemblages. Foraminifera are ideal for this ecological impact investigation because of differing test composition (calcareous and non-calcareous) and thickness, and diverse epifaunal and infaunal depth preferences. The experiment was conducted on August-September 2003, at 3600 m off the coast of Monterey Bay, California, aboard the R/V Western Flyer using the ROV Tiburon. The pH of the site was monitored throughout the experiment. Sediment push-cores were collected (both from the experimental and control sites) and stained to distinguish live (stained) from dead (unstained) individuals. Effects of CO2 injection on assemblages have been tracked both vertically (to 10 cm depth below sea floor) and horizontally (up to 10 m from CO2 injection sites), as well as between live and dead individuals. Within corrals (containing the injected CO2) and their underlying sediments, severe pH changes (near 4.0 units) were recorded. This compares with a record of small average reductions in ocean pH (-0.05 units) combined with large episodic excursions (-1.7 units) over the experimental area due to the injection of CO2. Exposure to this gradient of low pH caused increased mortality and dissolution of calcareous forms within corrals, as far as 5 m from the injection site, and to at least 10 cm depth in the sediments. This experiment revealed several major effects of CO2 injection on foraminiferal assemblages in surficial sediments: 1) total number of foraminifera in a sample decreases; 2) foraminiferal species richness decreases in both stained and unstained specimens; and 3) relative percentage of stained (live) forms in the remaining tests increases. Down-core trends (to 10 cm below sea floor) have revealed: 1) percent agglutinated forms decline and calcareous forms increase with depth; 2) agglutinated species richness decreases with depth; and 3) experimental core assemblages become increasingly similar with depth to those in control cores not subjected to CO2 injection. These results imply almost complete initial mortality and dissolution in the upper 10 cm throughout the corrals following liquid CO2 injection. Since calcareous foraminifera represent more than 50% of the total assemblages, this clearly indicates that emplacement of CO2 will result in negative effects to diversity and survivorship of the deep-sea benthic meiofauna.

54 ENVIRONMENTAL SCIENCES↗

Origin of texture development in orthorhombic uranium

We study texture evolution of alpha-uranium (α-U) during plane strain compression and uniaxial compression to high strains at different temperatures. We combine a multiscale polycrystal constitutive model and detailed analysis of texture data to uncover the slip and twinning modes responsible for the formation of individual texture components. The analysis indicates that during plane strain compression, floor slip (001)[100] results in the formation of two pronounced {001}{001} texture peaks tilted 10–15° away from the normal toward the rolling direction. During both high-temperature (573 K) through-thickness compression and plane strain compression, the active slip modes are floor slip (001)[100] and chimney slip 1/2{110} <11¯0> with slightly different ratios. {130} <31¯0> deformation twinning is profuse during rolling and in-plane compression and decreases with increasing temperature, but is not as active for through-thickness compression. Lastly, we comment on some similarities between rolling textures of α-U, which has a c/a ratio of 1.734, and those that develop in hexagonal close packed metals with similarly high c/a ratios like Zn (1.856) and Cd (1.885) and are dominated by basal slip.

36 MATERIALS SCIENCE↗

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗