FLUKA Analysis of Linac Fault Study Dose Rates
The planned Linac Fault Study was conducted on December 5 and 6, 2013 according to the Fault Study Procedure. Beam energy out the end of the Linac was typically 200 MeV, except for the LB-B1 Fault study that used 100 MeV beam out of the 4 th accelerator cavity (ACC4, also called and labeled as 4 th accelerating structure, AS4). The Linac fault study where beam was steered into the 4 th accelerator cavity (upstream) had beam energy of 150 MeV, since the last cavity was not traversed. Table I describes the list of the Beam Loss Fault Studies generated for verification of the Linac tunnel bulk and Linac supplemental shield effectiveness. The beam charge for the loss locations was typically measured at the LB-IT1 integrating current monitor after the ACC4 cavity, between LB-Q1 and LB-Q2. If beam was transported to the dumps a Faraday cup (LB-DU1 or LBDU2) monitor will yield the transported current to the dump, with the difference between LB-IT1 and LB-DU1 yielding the charge lost ahead of the dump. For beam miss-steered or intercepted ahead of the dumps the transport efficiency is zero. For the ACC4 beam loss fault the assumed current was the LB-ITI value before the miss-steering. For most of the faults the LB-ITI current was reading ~13.4 nC and the pulse rate was 1Hz, for 13.4 nC/s beam current.