Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Care 3, Phase 1, volume 1

A computer program to aid in accessing the reliability of fault tolerant avionics systems was developed. A simple mathematical expression was used to evaluate the reliability of any redundant configuration over any interval during which the failure rates and coverage parameters remained unaffected by configuration changes. Provision was made for convolving such expressions in order to evaluate the reliability of a dual mode system. A coverage model was also developed to determine the various relevant coverage coefficients as a function of the available hardware and software fault detector characteristics, and subsequent isolation and recovery delay statistics.

Stiffler, J. J.↗

Model-based diagnostics for Space Station Freedom

An innovative approach to fault management was recently demonstrated for the NASA LeRC Space Station Freedom (SSF) power system testbed. This project capitalized on research in model-based reasoning, which uses knowledge of a system's behavior to monitor its health. The fault management system (FMS) can isolate failures online, or in a post analysis mode, and requires no knowledge of failure symptoms to perform its diagnostics. An in-house tool called MARPLE was used to develop and run the FMS. MARPLE's capabilities are similar to those available from commercial expert system shells, although MARPLE is designed to build model-based as opposed to rule-based systems. These capabilities include functions for capturing behavioral knowledge, a reasoning engine that implements a model-based technique known as constraint suspension, and a tool for quickly generating new user interfaces. The prototype produced by applying MARPLE to SSF not only demonstrated that model-based reasoning is a valuable diagnostic approach, but it also suggested several new applications of MARPLE, including an integration and testing aid, and a complement to state estimation.

Fesq, Lorraine M.↗

Managing Cassini Safe Mode Attitude at Saturn

The Cassini spacecraft was launched on October 15, 1997 and arrived at Saturn on June 30, 2004. It has performed detailed observations and remote sensing of Saturn, its rings, and its satellites since that time. In the event safe mode interrupts normal orbital operations, Cassini has flight software fault protection algorithms to detect, isolate, and recover to a thermally safe and commandable attitude and then wait for further instructions from the ground. But the Saturn environment is complex, and safety hazards change depending on where Cassini is in its orbital trajectory around Saturn. Selecting an appropriate safe mode attitude that insures safe operation in the Saturn environment, including keeping the star tracker field of view clear of bright bodies, while maintaining a quiescent, commandable attitude, is a significant challenge. This paper discusses the Cassini safe table management strategy and the key criteria that must be considered, especially during low altitude flybys of Titan, in deciding what spacecraft attitude should be used in the event of safe mode.

Attitude Control↗

Automatic recognition of intermittent failures - An experimental study of field data

A methodology is proposed for recognizing the symptoms of persistent problems in large systems. The system error rate is used to identify the error states among which relationships may exist. Statistical techniques are used to validate and quantify the strength of the relationship among these error states. As input, the approach takes the raw error logs containing a single entry for each error that is detected as an isolated event. As output, it produces a list of symptoms that characterize persistent errors. Thus, given a failure, it is determined whether the failure is an intermittent manifestation of a common fault or whether it is an isolated (transient) incident. The technique is shown to work on two CYBER systems and an IBM 3081 multiprocessor system. Comparisons to real failure/repair information obtained from field engineers show that, in about 85 percent of the cases, the error symptoms recognized by this approach correspond to real problems. The remaining 15 percent of the cases, although not directly supported by field data, are confirmed as being valid problems.

Iyer, Ravishankar K.↗

Study of fault tolerant software technology for dynamic systems

The major aim of this study is to investigate the feasibility of using systems-based failure detection isolation and compensation (FDIC) techniques in building fault-tolerant software and extending them, whenever possible, to the domain of software fault tolerance. First, it is shown that systems-based FDIC methods can be extended to develop software error detection techniques by using system models for software modules. In particular, it is demonstrated that systems-based FDIC techniques can yield consistency checks that are easier to implement than acceptance tests based on software specifications. Next, it is shown that systems-based failure compensation techniques can be generalized to the domain of software fault tolerance in developing software error recovery procedures. Finally, the feasibility of using fault-tolerant software in flight software is investigated. In particular, possible system and version instabilities, and functional performance degradation that may occur in N-Version programming applications to flight software are illustrated. Finally, a comparative analysis of N-Version and recovery block techniques in the context of generic blocks in flight software is presented.

Caglayan, A. K.↗

On the design of fault-tolerant robotic manipulator systems

Robotic systems are finding increasing use in space applications. Many of these devices are going to be operational on board the Space Station Freedom. Fault tolerance has been deemed necessary because of the criticality of the tasks and the inaccessibility of the systems to maintenance and repair. Design for fault tolerance in manipulator systems is an area within robotics that is without precedence in the literature. In this paper, we will attempt to lay down the foundations for such a technology. Design for fault tolerance demands new and special approaches to design, often at considerable variance from established design practices. These design aspects, together with reliability evaluation and modeling tools, are presented. Mechanical architectures that employ protective redundancies at many levels and have a modular architecture are then studied in detail. Once a mechanical architecture for fault tolerance has been derived, the chronological stages of operational fault tolerance are investigated. Failure detection, isolation, and estimation methods are surveyed, and such methods for robot sensors and actuators are derived. Failure recovery methods are also presented for each of the protective layers of redundancy. Failure recovery tactics often span all of the layers of a control hierarchy. Thus, a unified framework for decision-making and control, which orchestrates both the nominal redundancy management tasks and the failure management tasks, has been derived. The well-developed field of fault-tolerant computers is studied next, and some design principles relevant to the design of fault-tolerant robot controllers are abstracted. Conclusions are drawn, and a road map for the design of fault-tolerant manipulator systems is laid out with recommendations for a 10 DOF arm with dual actuators at each joint.

Tesar, Delbert↗

Reinitialization issues in fault tolerant systems

This paper is concerned with the reinitialization of fault tolerant systems in which detection and isolation (FDI) techniques are used, on-line, to identify and compensate for system failures. Specifically, it will focus on FDI techniques which utilize analytic redundancy, arising from a knowledge of the plant dynamics, by analyzing the residuals of a no-fail filter designed on the assumption of no failures. In these types of fault tolerant systems, system failures have to propagate through the no-fail filter dynamics in order to get detected. Therefore, the no-fail filter must be reinitialized after the isolation of a failure so that the accumulated effects of the failure are removed. In this paper, various approaches to this reinitialization problem will be discussed.

Caglayan, A. K.↗

Demonstration of a fault impact reduction control module for wind turbines

Abstract. Traditionally, wind turbines in distributed applications make control decisions as isolated systems. They generally provide maximum power output during operation and manage internal faults with little consideration of the rest of the power system. Although fault detection and tolerance schemes are widely researched and implemented, controls to ameliorate such faults are uncommon in research and industry. The rapid shutdown of a wind turbine in a large transmission-connected wind plant will have a minimal impact on a large power system, but in a microgrid or isolated grid context the abrupt loss of a single wind turbine may cause grid instability and high stress on the system. This paper demonstrates a fault impact reduction control (FIRC) module for a wind turbine, which implements wider warning thresholds around fault thresholds. When the turbine crosses a warning threshold, the controller sends its predicted action to the grid controller, which facilitates the grid operator’s response to a potential wind turbine fault and then takes appropriate action to ameliorate the fault. Various test cases demonstrate the controller action under a variety of faults, and various scenarios demonstrate the grid benefit of an FIRC in both microgrid- and grid-connected contexts. The FIRC maximizes wind turbine generation and eases generation transition under a variety of fault scenarios. The FIRC module is easy to integrate with most existing controllers, just requiring derate capability, and can be easily modified to include the various warnings and thresholds that the user desires. This analysis is mainly performed in a MATLAB-Simulink-based research wind turbine model and is also implemented in the existing LabVIEW-based controller of the same research turbine at NREL.

17 WIND ENERGY↗

10 CFR 830 Major Modification Determination for the ATR Diesel Bus (E-3) and Switchgear Replacement

Near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project, subject of this determination, will replace the existent diesel-electrical bus (E-3) and associated switchgear. More specifically, INL proposes transitioning ATR to 100% commercial power with appropriate emergency backup to include: • Provide commercial power as the normal source of power to the ATR loads currently supplied by diesel-electric power. • Provide backup power to the critical ATR loads in the event of a loss of commercial power. • Replace obsolescent critical ATR power distribution equipment, e.g., switchgear, transformers, motor control centers, distribution panels. Completion of this and two other age-related projects (primary coolant pump and motor replacement and emergency firewater injection system replacement) will resolve major age related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues make the project a major modification: 1. Evaluation Criteria #2 (Footprint change). The addition of a new PC-4 structure to the ATR Facility to house safety-related SSCs requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., structural qualification, fire suppression) to ensure no adverse impacts to the safety-related functions of the housed equipment. 2. Evaluation Criteria #3 (Change of existing process). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps requires careful attention and analysis to ensure it meets a project primary object to maintain or reduce CDF and does not negatively affect the efficacy of the currently approved strategy. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps, based on the pre-conceptual design, will require the addition of two quick start diesel generators, their associated power coordination/distribution controls, and a UPS to the list of safety-related SSCs. Similarly to item 1 above, the addition of these active SSCs to the list of safety-related SSCs and replacement of the E-3 bus requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., seismic qualification, isolation of redundant trains from common fault failures) to ensure no adverse impacts to the safety-related functions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applicative architectures for fault-tolerant multiprocessors

This paper proposes functional programming frameworks for the design of highly reliable multiprocessor systems. In contrast to imperative programming environments, a functional environment offers elegant, relatively simple, and efficient solutions to concurrent error detection and recovery problems in multiprocessors. Specific fault tolerance mechanisms for upset exposure, fault containment, secure task assignment, and recovery are developed for a class of applicative multiprocessor architectures. Verification of abstract behavioral characteristics of applicative tasks is used for exposing faults during the execution of tasks. The fault containment mechanism is based on isolation of stack and heap segments of tasks. A protocol for secure task assignment is defined between system components. The architecture permits incremental, distributed, and asynchronous backups of system state. Finally, recovery is accomplished, even in the worst cases, by reexecution of a small number of tasks.

Sharma, Madhumitra↗

Applicative architectures for fault-tolerant multiprocessors

Functional programming frameworks for the design of highly reliable multiprocessor systems are proposed. In contrast to imperative programming environments, a functional environment offers elegant, relatively simple, and efficient solutions to concurrent error detection and recovery problems in multiprocessors. Specific fault tolerance mechanisms for upset exposure, fault containment, secure task assignment, and recovery are developed for a class of applicative multiprocessor architectures. Verification of abstract behavioral characteristics of applicative tasks is used for exposing faults during the execution of tasks. The fault containment mechanism is based on isolation of stack and heap segments of tasks. A protocol for secure task assignment is defined between system components. The architecture permits incremental, distributed, and asynchronous backups of system state. Finally, recovery is accomplished, even in the worst cases, by re-execution of a small number of tasks.

Sharma, Madhumitra↗

Lessons Learned in the Livingstone 2 on Earth Observing One Flight Experiment

The Livingstone 2 (L2) model-based diagnosis software is a reusable diagnostic tool for monitoring complex systems. In 2004, L2 was integrated with the JPL Autonomous Sciencecraft Experiment (ASE) and deployed on-board Goddard's Earth Observing One (EO-1) remote sensing satellite, to monitor and diagnose the EO-1 space science instruments and imaging sequence. This paper reports on lessons learned from this flight experiment. The goals for this experiment, including validation of minimum success criteria and of a series of diagnostic scenarios, have all been successfully net. Long-term operations in space are on-going, as a test of the maturity of the system, with L2 performance remaining flawless. L2 has demonstrated the ability to track the state of the system during nominal operations, detect simulated abnormalities in operations and isolate failures to their root cause fault. Specific advances demonstrated include diagnosis of ambiguity groups rather than a single fault candidate; hypothesis revision given new sensor evidence about the state of the system; and the capability to check for faults in a dynamic system without having to wait until the system is quiescent. The major benefits of this advanced health management technology are to increase mission duration and reliability through intelligent fault protection, and robust autonomous operations with reduced dependency on supervisory operations from Earth. The work-load for operators will be reduced by telemetry of processed state-of-health information rather than raw data. The long-term vision is that of making diagnosis available to the onboard planner or executive, allowing autonomy software to re-plan in order to work around known component failures. For a system that is expected to evolve substantially over its lifetime, as for the International Space Station, the model-based approach has definite advantages over rule-based expert systems and limit-checking fault protection systems, as these do not scale well. The model-based approach facilitates reuse of the L2 diagnostic software; only the model of the system to be diagnosed and telemetry monitoring software has to be rebuilt for a new system or expanded for a growing system. The hierarchical L2 model supports modularity and expendability, and as such is suitable solution for integrated system health management as envisioned for systems-of-systems.

Hayden, Sandra C.↗

Geologic and mineral and water resources investigations in western Colorado, using Skylab EREP data

The author has identified the following significant results. Discovery of three major north-trending, throughgoing faults in the Front Range, previously mapped only as isolated segments, demonstrates the utility of space photography and may lead to reinterpretation of the Front Range tectonic style. Faulting and alteration appear to be the most useful indicators of mineralization in central Colorado. These phenomena appear on Skylab photography as tonal lineaments and color anomalies. Twenty-three lineaments have been mapped in the San Juan Mountains, the longest of which is 156 km long. Twelve lineaments intersect or are tangent to calderas. Intrusive domes are aligned along lineaments, but calderas appear to occur at the intersections of major lineaments. Lineaments can be recognized on some EREP passes but not on other passes over the same area. The difference is attributed to solar elevation effects. Bedding attitudes can be photogeologically estimated down to surprisingly low dips, on the order of + or - 1-2 deg, and attitudes can be subdivided easily into quantitative groups. The primary application of Skylab photography to geologic mapping in montane areas is clearly limited to regional mapping at scales smaller than 1:24,000.

Lee, K.↗

Validation methods for flight crucial systems

Research to develop techniques that can aid in determining the reliability and performance of digital electronic fault-tolerant systems, that have probability of catastrophic system failure on the order of 10 to the -9th at 10 hours, is reviewed. The computer-aided reliability estimation program (CARE III) provides general-purpose reliability analysis and a design tool for fault-tolerant systems; large reduction of state size; and a fault-handling model based on probabilistic description of detection, isolation, and recovery mechanisms. The application of design proof techniques as part of the design and development of the software implemented fault-tolerance computer is mentioned. Emulation techniques and experimental procedures are verified using specimens of fault-tolerant computers and the capabilities of the validation research laboratory, AIRLAB.

Holt, H. M.↗

In situ observations on the coupling between hydraulic diffusivity and displacements during fault reactivation in shales

Key questions in fault reactivation in shales relate to the potential for enhanced fluid transport through previously low-permeability aseismic formations. Here, we explore the behavior of a 20 m long N0-to-170°, 75-to-80°W fault in shales that is critically stressed under a strike-slip regime (σ 1 = 4 ± 2 MPa, horizontal and N162° ± 15°E, σ 2 = 3.8 ± 0.4 MPa and σ 3 = 2.1 ± 1 MPa, respectively 7-8° inclined from vertical and horizontal and N72°). The fault was reactivated by fluid pressurization in a borehole using a straddle packer system isolating a 2.4 m long injection chamber oriented-subnormal to the fault surface at a depth of 250 m. A three-dimensional displacement sensor attached across the fault allowed monitoring fault movements, injection pressure and flow rate. Pressurization induced a hydraulic diffusivity increase from ~2 × 10 -9 to ~10 3 m 2 s -1 associated with a complex three-dimensional fault movement. The shear (x-, z-) and fault-normal (y-) components (U x , U y , and U z ) = (44.0 × 10 -6 m, 10.5 × 10 -6 m, and 20.0 × 10 -6 m) are characterized by much larger shear displacements than the normal opening. Numerical analyses of the experiment show that the fault permeability evolution is controlled by the fault reactivation in shear related to Coulomb failure. The large additional fault hydraulic aperture for fluid flow is not reflected in the total normal displacement that showed a small partly contractile component. This suggests that complex dilatant effects estimated to occur in a plurimeter radius around the injection source affect the flow and slipping patch geometries during fault rupture, controlling the initial slow slip and the strong back slip of the fault following depressurization.

58 GEOSCIENCES↗

A Fusing Switch for Fault Suppression in the SNS High Voltage Converter Modulators

The High Voltage Converter Modulators (HVCMs) at the Spallation Neutron Source (SNS) have operated in excess of a combined 250,000 hours. Performance and reliability improvements to the HVCM are ongoing to increase modulator availability as accelerator system demands increase. There is a relatively large amount of energy storage in the HVCMs, {approx}180 kJ. This energy has the potential to dump into unsuppressed faults, cause damage, and increase the time to repair. The 'fusing switch' concept involves isolation of this stored energy from the location of the most common faults. This paper introduces this concept and its application to the HVCMs.

43 PARTICLE ACCELERATORS↗