Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error vector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Video data compression using artificial neural network differential vector quantization

An artificial neural network vector quantizer is developed for use in data compression applications such as Digital Video. Differential Vector Quantization is used to preserve edge features, and a new adaptive algorithm, known as Frequency-Sensitive Competitive Learning, is used to develop the vector quantizer codebook. To develop real time performance, a custom Very Large Scale Integration Application Specific Integrated Circuit (VLSI ASIC) is being developed to realize the associative memory functions needed in the vector quantization algorithm. By using vector quantization, the need for Huffman coding can be eliminated, resulting in superior performance against channel bit errors than methods that use variable length codes.

Krishnamurthy, Ashok K.↗

Kalman Filter for Spinning Spacecraft Attitude Estimation

This paper presents a Kalman filter using a seven-component attitude state vector comprising the angular momentum components in an inertial reference frame, the angular momentum components in the body frame, and a rotation angle. The relatively slow variation of these parameters makes this parameterization advantageous for spinning spacecraft attitude estimation. The filter accounts for the constraint that the magnitude of the angular momentum vector is the same in the inertial and body frames by employing a reduced six-component error state. Four variants of the filter, defined by different choices for the reduced error state, are tested against a quaternion-based filter using simulated data for the THEMIS mission. Three of these variants choose three of the components of the error state to be the infinitesimal attitude error angles, facilitating the computation of measurement sensitivity matrices and causing the usual 3x3 attitude covariance matrix to be a submatrix of the 6x6 covariance of the error state. These variants differ in their choice for the other three components of the error state. The variant employing the infinitesimal attitude error angles and the angular momentum components in an inertial reference frame as the error state shows the best combination of robustness and efficiency in the simulations. Attitude estimation results using THEMIS flight data are also presented.

Markley, F. Landis↗

Kalman Filter for Spinning Spacecraft Attitude Estimation

This paper presents a Kalman filter using a seven-component attitude state vector comprising the angular momentum components in an inertial reference frame, the angular momentum components in the body frame, and a rotation angle. The relatively slow variation of these parameters makes this parameterization advantageous for spinning spacecraft attitude estimation. The filter accounts for the constraint that the magnitude of the angular momentum vector is the same in the inertial and body frames by employing a reduced six-component error state. Four variants of the filter, defined by different choices for the reduced error state, are tested against a quaternion-based filter using simulated data for the THEMIS mission. Three of these variants choose three of the components of the error state to be the infinitesimal attitude error angles, facilitating the computation of measurement sensitivity matrices and causing the usual 3x3 attitude covariance matrix to be a submatrix of the 6x6 covariance of the error state. These variants differ in their choice for the other three components of the error state. The variant employing the infinitesimal attitude error angles and the angular momentum components in an inertial reference frame as the error state shows the best combination of robustness and efficiency in the simulations. Attitude estimation results using THEMIS flight data are also presented.

Markley, F. Landis↗

Estimating Dust and Water Ice Content of the Martian Atmosphere From THEMIS Data

Researchers at JPL and Arizona State University conducted a comparative study of three candidate algorithms for estimating components of the Martian atmosphere, using raw (uncalibrated) data collected by the Thermal Emission Imaging System (THEMIS). THEMIS is an instrument onboard the Mars Odyssey spacecraft that acquires image data in five visible and nine infrared (IR) wavelength bands. The algorithms under study used data collected from eight of the nine IR bands to estimate the dust and water ice content of the atmosphere. Such an algorithm could be used in onboard data processing to trigger other algorithms that search for features of scientific interest and to reduce the volume of data transmitted to Earth. The algorithms studied were based on regression models. In the study, the optical depths estimated by these algorithms were compared with optical depths estimated in ground-based processing using fully calibrated data from both THEMIS and the Thermal Emission Spectrometer (TES). TES is an instrument onboard the Mars Global Surveyor spacecraft that also observes the planet at infrared wavelengths, but at a lower spatial resolution than THEMIS does. Of the algorithms studied, the one that performed best was based on a Gaussian Support Vector Machine regression model. The test results indicated that this algorithm, operating on the raw data, had error rates that were within the uncertainty associated with the estimates obtained by the groundbased analysis of the fully calibrated data. This level of fidelity demonstrates that these algorithms are sufficiently accurate for use in an onboard setting.

Bandfield, Joshua↗

Scalable Lunar Surface Networks and Adaptive Orbit Access

Teranovi Technologies, Inc., has developed innovative network architecture, protocols, and algorithms for both lunar surface and orbit access networks. A key component of the overall architecture is a medium access control (MAC) protocol that includes a novel mechanism of overlaying time division multiple access (TDMA) and carrier sense multiple access with collision avoidance (CSMA/CA), ensuring scalable throughput and quality of service. The new MAC protocol is compatible with legacy Institute of Electrical and Electronics Engineers (IEEE) 802.11 networks. Advanced features include efficiency power management, adaptive channel width adjustment, and error control capability. A hybrid routing protocol combines the advantages of ad hoc on-demand distance vector (AODV) routing and disruption/delay-tolerant network (DTN) routing. Performance is significantly better than AODV or DTN and will be particularly effective for wireless networks with intermittent links, such as lunar and planetary surface networks and orbit access networks.

Wang, Xudong↗

Mars Sample Return, Sample Retrieval Lander, Reaction Control System Jet Interaction Supersonic Wind Tunnel Test Overview with CFD Predictions

NASA's Mars Sample Return campaign will be launching several missions over the next decade that will work together to return rock samples from Mars back to Earth. The Sample Retrieval Lander (SRL) will deliver the Mars Ascent Vehicle and fetch rover to the surface of Mars in 2006. Rock samples collected by the Mars 2020 Perseverance rover, landing in early 2021, will be loaded on the the ascent vehicle to be launched into Mars orbit for retrieval by yet another spacecraft. The Sample Retrieval Lander will be a blunt entry capsule similar to past Mars entry vehicles like Mars Science Laboratory and Viking. The vehicle will fly a guided entry, using a small lift vector produced by a non-zero trim angle of attack to eliminate downrange and crossrange position errors at the point of parachute deploy. This energy and heading management is achieved with a reaction control system (RCS) that directs the bank angle of the vehicle and also minimizes unwanted capsule dynamics. The reaction control system and control design is based on the Mars Science Laboratory and Mars 2020 RCS systems. However, due to packaging constraints, the backshell of this new entry vehicle has a different geometry than those earlier designs. To certify the RCS system for flight the project must characterize the jet plume interactions with the capsule backshell that could impair or significantly augment the RCS control authority. This characterization will be done through a combination of computational fluid dynamics (CFD) analysis and wind tunnel test. Two candidate arrangements of the RCS jets have been identified for the SRL vehicle and are currently under evaluation before final selection. The aero/RCS plume interactions of these candidate configurations have been measured in a supersonic wind tunnel test in NASA Langley's Unitary Plan Wind Tunnel. The test was conducted in the fall of 2020 and data is currently being reduced. An overview of the candidate RCS configurations are presented here with an overview of the wind tunnel model design, jet scaling and scaled nozzle design, and the test matrix. Preliminary CFD runs are presented with an assessment of the predicted plumes and their interaction with the wake flow of the vehicle. The predicted effects of the model sting is provided as well. This high fidelity wind tunnel test is being conducted much earlier in the SRL project than would normally be done. The test was funded as part of a CFD evaluation task funded by NASA's Aerosciences Evaluation and Test Capabilities Project. The objective of the evaluation task was to compare the ability of CFD to predict complex flows with data that can be measured in the Langley Unitary Plan Wind Tunnel. RCS Jet interactions were selected as a type of complex flow that is important to NASA missions. In addition to providing useful data to the SRL project, there was added emphasis on quantifying the accuracy of the CFD predictions and wind tunnel test data. An overview of the uncertainty quantification methodologies for computational and experimental portions of this test is presented.

blunt body↗

Improving Adhesive Bondline Time of Flight Predictions During Autoclave Cure Utilizing Machine Learning

Composite materials are increasingly being used in aerospace applications due to their superior strength-to-weight ratio compared to commonly used metals. A current limitation to widespread adoption is the certification of adhesively bonded joints. One approach to improving adhesive bonding in composites is accurately measuring the thickness of adhesive bondlines in composite laminates. Precise bondline thickness control is essential for aerospace applications where adhesive layer thickness directly affects joint fracture properties and structural performance. This study focused on implementing machine learning techniques to determine the ultrasonic time of flight (directly correlated to thickness) in adhesive bondlines throughout autoclave cure cycles. A high-temperature (use up to 180°C) ultrasonic scanning system was deployed in an autoclave to provide time of flight data through composite panels. Three experiments were conducted on the curing of 305 mm × 305 mm unidirectional composite panels. In the first experiment, a piecewise function was fit for the temperature correction factor to account for changing autoclave temperatures. Due to deficiencies in the first calibration experiment, a second experiment was run, and the results were used to train a machine learning model. The revised experiment, in combination with the machine learning model, significantly increased the accuracy of the bondline time of flight predictions (~14% error reduced to <1%). Data was processed using the Regression Learner Application in MATLAB®, with a Support Vector Machine selected for the model. The result was a machine learning algorithm capable of reliably quantifying ultrasonic time of flight through adhesive bondlines. The third experiment provided independent test data for the machine learning model, demonstrating that the model produces accurate predictions from data beyond its training set.

Machine Learning↗

Ground-Support Algorithms for Simulation, Processing, and Calibration of Barnes Static Earth Sensor Measurements: Applications to Tropical Rainfall Measuring Mission Observatory

New algorithms are described covering the simulation, processing, and calibration of penetration angles of the Barnes static Earth sensor assembly (SESA) as implemented in the Goddard Space Flight Center Flight Dynamics Division ground support system for the Tropical Rainfall Measuring Mission (TRMM) Observatory. The new treatment involves a detailed analysis of the measurements by individual quadrants. It is shown that, to a good approximation, individual quadrant misalignments can be treated simply as penetration angle biases. Simple formulas suitable for real-time applications are introduced for computing quadrant-dependent effects. The simulator generates penetration angles by solving a quadratic equation with coefficients uniquely determined by the spacecraft's position and the quadrant's orientation in GeoCentric Inertial (GCI) coordinates. Measurement processing for attitude determination is based on linearized equations obtained by expanding the coefficients of the aforementioned quadratic equation as a Taylor series in both the Earth oblateness coefficient (alpha approx. 1/150) and the angle between the pointing axis and the geodetic nadir vector. A simple formula relating a measured value of the penetration angle to the deviation of the Earth-pointed axis from the geodetic nadir vector is derived. It is shown that even near the very edge of the quadrant's Field Of View (FOV), attitude errors resulting from quadratic effects are a few hundredths of a degree, which is small compared to the attitude determination accuracy requirement (0.18 degree, 3 sigma) of TRMM. Calibration of SESA measurements is complicated by a first-order filtering used in the TRMM onboard algorithm to compute penetration angles from raw voltages. A simple calibration scheme is introduced where these complications are avoided by treating penetration angles as the primary raw measurements, which are adjusted using biases and scale factors. In addition to three misalignment parameters, the calibration state vector contains only two average penetration angle biases (one per each pair of opposite quadrants) since, because of the very narrow sensor FOV (+/- 2.6 degrees), differences between biases of the penetration angles measured by opposite quadrants cannot be distinguished from roll and pitch sensor misalignments. After calibration, the estimated misalignments and average penetration angle biases are converted to the four penetration angle biases and to the yaw misalignment angle. The resultant biases and the estimated scale factors are finally used to update the coefficients necessary for onboard computations of penetration angles from measured voltages.

Natanson, G. A.↗

The FIELDS Instrument Suite on MMS: Scientific Objectives, Measurements, and Data Products

The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of these fields with sensitive cross-calibrations both before and after launch. The FIELDS magnetic sensors consist of redundant flux-gate magnetometers (AFG and DFG) over the frequency range from DC to 64 Hz, a search coil magnetometer (SCM) providing AC measurements over the full whistler mode spectrum expected to be seen on MMS, and an Electron Drift Instrument (EDI) that calibrates offsets for the magnetometers. The FIELDS three-axis electric field measurements are provided by two sets of biased double-probe sensors (SDP and ADP) operating in a highly symmetric spacecraft environment to reduce significantly electrostatic errors. These sensors are complemented with the EDI electric measurements that are free from all local spacecraft perturbations. Cross-calibrated vector electric field measurements are thus produced from DC to 100 kHz, well beyond the upper hybrid resonance whose frequency provides an accurate determination of the local electron density. Due to its very large geometric factor, EDI also provides very high time resolution (∼1 ms) ambient electron flux measurements at a few selected energies near 1 keV. This paper provides an overview of the FIELDS suite, its science objectives and measurement requirements, and its performance as verified in calibration and cross-calibration procedures that result in anticipated errors less than 0.1 nT in B and 0.5 mV/m in E. Summaries of data products that result from FIELDS are also described, as well as algorithms for cross-calibration. Details of the design and performance characteristics of AFG/DFG, SCM, ADP, SDP, and EDI are provided in five companion papers.

Electromagnetic field measurements↗

Probabilistic Error Bounds for Low-Rank Tensor Decompositions Used in Large-Scale Data Analysis Applications (LDRD Final Report)

This report documents a research project on analyzing low-rank tensor models for data analysis that took place at Sandia National Laboratories from October 2023–September 2025. The focus of this work was to extend theoretical frameworks from statistics and probability theory for use with models for scalar, vector, and matrix data to models with tensor, or general multi-dimensional array, data. Through this work, we have provided a new set of tools for bounding errors on low-rank tensor models of both complete and sampled data. The remainder of this report is organized as follows. In Section 1, we describe the proposed work at the start of the project. Section 2 describes the research advances made as part of the project. Other research contributions in the form of conference presentations and software development is provided in Section 3. Workforce development at Sandia and Florida Atlantic University (via a subcontract on this project) is provided in Section 4.

97 MATHEMATICS AND COMPUTING↗

An Empirical State Error Covariance Matrix for Batch State Estimation

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. Consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. It then follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully account for the error in the state estimate. By way of a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm, it is possible to arrive at an appropriate, and formally correct, empirical state error covariance matrix. The first specific step of the method is to use the average form of the weighted measurement residual variance performance index rather than its usual total weighted residual form. Next it is helpful to interpret the solution to the normal equations as the average of a collection of sample vectors drawn from a hypothetical parent population. From here, using a standard statistical analysis approach, it directly follows as to how to determine the standard empirical state error covariance matrix. This matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty. Also, in its most straight forward form, the technique only requires supplemental calculations to be added to existing batch algorithms. The generation of this direct, empirical form of the state error covariance matrix is independent of the dimensionality of the observations. Mixed degrees of freedom for an observation set are allowed. As is the case with any simple, empirical sample variance problems, the presented approach offers an opportunity (at least in the case of weighted least squares) to investigate confidence interval estimates for the error covariance matrix elements. The diagonal or variance terms of the error covariance matrix have a particularly simple form to associate with either a multiple degree of freedom chi-square distribution (more approximate) or with a gamma distribution (less approximate). The off diagonal or covariance terms of the matrix are less clear in their statistical behavior. However, the off diagonal covariance matrix elements still lend themselves to standard confidence interval error analysis. The distributional forms associated with the off diagonal terms are more varied and, perhaps, more approximate than those associated with the diagonal terms. Using a simple weighted least squares sample problem, results obtained through use of the proposed technique are presented. The example consists of a simple, two observer, triangulation problem with range only measurements. Variations of this problem reflect an ideal case (perfect knowledge of the range errors) and a mismodeled case (incorrect knowledge of the range errors).

Frisbee, Joseph H., Jr.↗

Validation of the DESI DR2 measurements of baryon acoustic oscillations from galaxies and quasars

The Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2) galaxy and quasar clustering data represents a significant expansion of data from Data Release 1 (DR1), providing improved statistical precision in baryon acoustic oscillation (BAO) constraints across multiple tracers, including bright galaxies, luminous red galaxies, emission line galaxies, and quasars. In this paper, we validate the BAO analysis of DR2. We present the results of robustness tests on the blinded DR2 data and, after unblinding, consistency checks on the unblinded DR2 data. All results are compared with those obtained from a suite of mock catalogs that replicate the selection and clustering properties of the DR2 sample. We confirm the consistency of DR2 BAO measurements with DR1 while achieving a reduction in statistical uncertainties due to the increased survey volume and completeness. The combined BAO precision, including both statistical and systematic errors, improves from ∼0.52% in DR1 to 0.30% in DR2—a factor of 1.7 gain. We assess the impact of analysis choices, including different data vectors (correlation function vs power spectrum), modeling approaches and systematics treatments, and an assumption of the Gaussian likelihood, finding that our BAO constraints are stable across these variations and assumptions with a few minor refinements to the baseline setup of the DR1 BAO analysis. We summarize a series of pre-unblinding tests that confirmed the readiness of our analysis pipeline, the final systematic errors, and the DR2 BAO analysis baseline. The successful completion of these tests led to the unblinding of the DR2 BAO measurements, ultimately leading to the DESI DR2 cosmological analysis, with their implications for the expansion history of the Universe and the nature of dark energy presented in the DESI key paper (companion paper).

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior-posterior direction, with systematic ( N-Ary-Summation ) and random ({sigma}) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%{+-}19.8% of treatment time. Real-time tracking reduced prostate motion to N-Ary-Summation =0.01 mm and {sigma} = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%{+-}4.6% and 99.7%{+-}0.4% of the time, respectively. Without real-time tracking, pass rates based on a {gamma} index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 71: A 4D Multimodal Lung Phantom for Regmentation Evaluation

Segmentation and registration of medical imaging data are two processes that can be integrated (a process termed regmentation) to iteratively reinforce each other, potentially improving efficiency and overall accuracy. A significant challenge is presented when attempting to validate the joint process particularly with regards to minimizing geometric uncertainties associated with the ground truth while maintaining anatomical realism. This work demonstrates a 4D MRI, PET, and CT compatible tissue phantom with a known ground truth for evaluating registration and segmentation accuracy. The phantom consists of a preserved swine lung connected to an air pump via a PVC tube for inflation. Mock tumors were constructed from sea sponges contained within two vacuum-sealed compartments with catheters running into each one for injection of radiotracer solution. The phantom was scanned using a GE Discovery-ST PET/CT scanner and a 0.23T Phillips MRI, and resulted in anatomically realistic images. A bifurcation tracking algorithm was implemented to provide a ground truth for evaluating registration accuracy. This algorithm was validated using known deformations of up to 7.8 cm using a separate CT scan of a human thorax. Using the known deformation vectors to compare against, 76 bifurcation points were selected. The tracking accuracy was found to have maximum mean errors of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior directions, respectively. A pneumatic control system is under development to match the respiratory profile of the lungs to a breathing trace from an individual patient.

60 APPLIED LIFE SCIENCES↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

An algorithm for targeting finite burn maneuvers

An algorithm was developed to solve the following problem: given the characteristics of the engine to be used to make a finite burn maneuver and given the desired orbit, when must the engine be ignited and what must be the orientation of the thrust vector so as to obtain the desired orbit? The desired orbit is characterized by classical elements and functions of these elements whereas the control parameters are characterized by the time to initiate the maneuver and three direction cosines which locate the thrust vector. The algorithm was built with a Monte Carlo capability whereby samples are taken from the distribution of errors associated with the estimate of the state and from the distribution of errors associated with the engine to be used to make the maneuver.

Barbieri, R. W.↗

Extensions and improvements on XTRAN3S

Improvements to the XTRAN3S computer program are summarized. Work on this code, for steady and unsteady aerodynamic and aeroelastic analysis in the transonic flow regime has concentrated on the following areas: (1) Maintenance of the XTRAN3S code, including correction of errors, enhancement of operational capability, and installation on the Cray X-MP system; (2) Extension of the vectorization concepts in XTRAN3S to include additional areas of the code for improved execution speed; (3) Modification of the XTRAN3S algorithm for improved numerical stability for swept, tapered wing cases and improved computational efficiency; and (4) Extension of the wing-only version of XTRAN3S to include pylon and nacelle or external store capability.

Borland, C. J.↗

Sources of error in the graphical analysis of CFD results

Errors inherent to the graphic analysis of CFD solutions are discussed. Consideration is given to contouring, plotting of vector fields, particle tracing, and the computation of flow functions involving integration or differentiation. Many of the problems addressed are the direct result of knowing the function values only at grid points, not in the interior of the grid cells.

Buning, Pieter G.↗