Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Early Dark Energy from Massive Neutrinos as a Natural Resolution of the Hubble Tension

The Hubble tension can be significantly eased if there is an early component of dark energy that becomes active around the time of matter-radiation equality. Early dark energy models suffer from a coincidence problem—the physics of matter-radiation equality and early dark energy are completely disconnected, so some degree of fine-tuning is needed in order for them to occur nearly simultaneously. In this Letter, we propose a natural explanation for this coincidence. If the early dark energy scalar couples to neutrinos then it receives a large injection of energy around the time that neutrinos become nonrelativistic. This is precisely when their temperature is of order of their mass, which, coincidentally, occurs around the time of matter-radiation equality. Neutrino decoupling therefore provides a natural trigger for early dark energy by displacing the field just before matter-radiation equality. Finally, we discuss various theoretical aspects of this proposal, potential observational signatures, and future directions for its study.

79 ASTRONOMY AND ASTROPHYSICS↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving Zero Energy Office Buildings to the Mainstream: Establishing Design Guidelines and Energy Targets: Preprint

Office buildings represent a significant portion of the commercial sector and are ideal candidates to lead the market towards achieving zero energy or zero energy ready buildings. The variety of sizes and uses for office buildings make them challenging to determine set design guidance that can be deployed across the market. A project committee for ASHRAE’s Zero Energy - Advanced Energy Design Guide (ZE-AEDG) for small and medium office buildings , comprised of members from five major national associations with market-pull in commercial buildings, created design guidance for achieving zero energy office buildings for new construction and major retrofit. This design guidance focuses on the process, providing a pathway for both office owners and design teams to achieve zero energy status. Energy use intensity targets range from 16 kBtu/ft²·yr to 36 kBtu/ft²·yr for the different climate zones were established such that office buildings can be “zero-ready,” that is, having low energy consumption that can easily be offset with renewables, preferably on-site. The design guidance was rooted in extensive energy modeling, as well as case studies of actual office buildings that have achieved high levels of energy performance and met zero energy or zero energy ready status. A unique aspect of the zero-energy guide is that it is not compared against a baseline but focuses on achieving an absolute target. The paper presents process of creating the targets, the selection of strategies to achieve the targets, and sample case studies that show how the cost-sensitive solutions are achievable for the design community. It also presents outreach strategies to deploy market achievable zero energy measures.

buildings↗

Heating Ventilation Air-Conditioning (HVAC) System Analysis and Optimization for Revit with the OpenStudio Analytical Framework (CRADA Final Report)

This project proposes to integrate the NREL-developed OpenStudio (OS) and its accompanying Analytical Framework (OSAF) into Autodesk’s (ADSK’s) market leading suite of building information modeling (BIM) tools. As a result, BIM users will gain access to advanced (but user-friendly) building energy modeling (BEM), calibration, and design optimization capabilities. Following integration, the BIM software will automatically generate a consistent OS-based BEM model, allowing users to develop projects in an integrated manner, moving back and forth between architectural and engineering perspectives without redundancy or data loss, saving time and effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Subhourly Inverter Clipping Loss From Satellite-Derived Irradiance Data

Photovoltaic system production simulations are conventionally run using hourly weather datasets. Hourly simulations are sufficiently accurate to predict the majority of long-term system behavior but cannot resolve high-frequency effects like inverter clipping caused by short-duration irradiance variability. Direct modeling of this subhourly clipping error is only possible for the few locations with high-resolution irradiance datasets. This paper describes a method of predicting the magnitude of this error using a machine learning regressor ensemble model, comprised of a random forest and an XGBoost model, and 30-minute satellite irradiance data. The method predicts a correction for each 30-minute interval with the potential to roll up into 60-minute corrections to match an hourly energy model. The model is trained and validated at locations where the error can be directly simulated from 1-minute ground data. The validation shows low bias at most ground station locations. The model is also applied to gridded satellite irradiance to produce a heatmap of the estimated clipping error across the United States. Finally, the relative importance of each predictor satellite variable is retrieved from the model and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Summary: Techno-Economic Analysis of Solar Photovoltaics and Battery Energy Storage at a Vietnam Industrial Park

The Clean Energy Investment Accelerator conducted a case study analysis of battery energy storage system (BESS) feasibility for an industrial park in Vietnam using the National Renewable Energy Laboratory's (NREL's) REopt platform (a distributed energy modeling and optimization tool) to evaluate how BESS may reduce electricity costs, increase utilization of onsite renewable energy generation, and improve resilience to utility grid outages. This presentation summarizes the analysis and key takeaways.

batteries↗

A Parallel Computing Infrastructure for Building Energy Simulation

In order to study grid-interactive efficient buildings, Pacific Northwest National Laboratories (PNNL) needs an infrastructure for urban-scale building energy modeling. Such an infrastructure should be fast, scalable, and easy-to-use. Given a set of data from the Energy Information Administration’s Commercial Building Energy Consumption Survey (CBECS) and tool to translate survey data into simulation inputs, this project aimed to conduct the simulation of the entire dataset in parallel. Before running the simulations, the necessary software was bundled into a container for use on the PNNL supercomputing network. Then, the parallel simulation workflow was designed using GNU Make, a file creation software, and submitted to a supercomputing partition which could run hundreds of simulations simultaneously. The EnergyPlus simulations output hourly electric meter data for each CBECS sample, which represents the electricity consumption of similar commercial buildings across the United States. Analyzing and visualizing the meter data is important to the future of the work, and this project wrote code to make common analysis methods simple, fast, and accessible. Moving forwards, the model will need to be expanded to include data from other sources and its accuracy will need to be improved and eventually validated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing physics beyond the standard model: limits from BBN and the CMB independently and combined

We present new Big Bang Nucleosynthesis (BBN) limits on the cosmic expansion rate or relativistic energy density, quantified via the number N ν of equivalent neutrino species. We use the latest light element observations, neutron mean lifetime, and update our evaluation for the nuclear rates d + d → 3 He + n and d + d → 3 H+p. Combining this result with the independent constraints from the cosmic microwave background (CMB) yields tight limits on new physics that perturbs N ν and η prior to cosmic nucleosynthesis: a joint BBN+CMB analysis gives N ν = 2.898 ± 0.141, resulting in N ν < 3.180 at 2σ. We apply these limits to a wide variety of new physics scenarios including right-handed neutrinos, dark radiation, and a stochastic gravitational wave background. The strength of the independent BBN and CMB constraints now opens a new window: we can search for limits on potential changes in N ν and/or the baryon-to-photon ratio η between the two epochs. The present data place strong constraints on the allowed changes in N ν between BBN and CMB decoupling; for example, we find -0.708 < N ν CMB - N ν BBN < 0.328 in the case where η and the primordial helium mass fraction Yp are unchanged between the two epochs; we also give limits on the allowed variations in η or in (η, N ν ) jointly. We discuss scenarios in which such changes could occur, and show that BBN+CMB results combine to place important constraints on some early dark energy models to explain the H 0 tension. Looking to the future, we forecast the tightened precision for N ν arising from both CMB Stage 4 measurements as well as improvements in astronomical 4 He measurements. Here, we find that CMB-S4 combined with present BBN and light element observation precision can give σ(N ν ) ≃ 0.03. Such future precision would reveal the expected effect of neutrino heating (N eff -3 = 0.044) of the CMB during BBN, and would be near the level to reveal any particle species ever in thermal equilibrium with the standard model. Improved Y p measurements can push this precision even further.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Resilient Communities, Maryland (RCM): A Framework for Community-Driven Energy Resilience (Final Technical Report)

The Resilient Communities, Maryland (RCM) project integrates community-based participatory research (CBPR) approaches into energy resilience planning. The combination of qualitative, community-driven data and quantitative utility data improves both the effectiveness and efficiency of assessing the impacts of disruptions to energy infrastructure. Centered around a metric of critical services access, RCM created a repeatable framework for evaluating and modeling energy resilience in communities and promoted community engagement, resulting in more equitable stakeholder participation and improved decision-making processes for siting infrastructure to improve community energy resilience.

14 SOLAR ENERGY↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating Subhourly Inverter Clipping Loss From Satellite-Derived Irradiance Data: Preprint

Photovoltaic system production simulations are conventionally run using hourly weather datasets. Hourly simulations are sufficiently accurate to predict the majority of long-term system behavior but cannot resolve high-frequency effects like inverter clipping caused by short-duration irradiance variability. Direct modeling of this subhourly clipping error is only possible for the few locations with high-resolution irradiance datasets. This paper describes a method of predicting the magnitude of this error using a machine learning model and 30-minute satellite irradiance data. The method predicts a correction for each 30-minute interval with the potential to roll up into 60-minute corrections to match an hourly energy model. The model is trained and validated at locations where the error can be directly simulated from 1-minute ground data. The validation shows low bias at most ground station locations. The model is also applied to gridded satellite irradiance to produce a heatmap of the estimated clipping error across the United States. Finally, the relative importance of each predictor satellite variable is retrieved from the model and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electric Vehicle Charging for Residential and Commercial Energy Codes: Technical Brief

Numerous studies show that sales of electric vehicles (EVs) have grown consistently over recent years in the U.S. The U.S. Energy Information Administration (EIA) estimated 3 million EVs were on the road in 2022, and the Edison Electric Institute (EEI) forecasts a total of 26.4 million EVs on the road by 2030. Based on this forecast, EEI projects the need for an additional 12.9 million EV charge ports by 2030. If EV charging infrastructure fails to keep pace with sales of EVs it could result in consumers stranded without options to power their vehicles. EVs are capable of providing substantial benefits to the consumers. EVs are less expensive to operate than conventional internal combustion engine vehicles, have lower maintenance costs, and have the convenience of fueling (charging) at home or work. Studies conducted in California show that costs associated with installing EV charging infrastructure can be substantially more expensive for retrofit scenarios compared to new construction, making inclusion of EV infrastructure in new construction codes a cost-effective policy option to increase infrastructure to meet growing demands. PNNL tracks adoption of mandatory EV provisions across the U.S. As of December 20, 2024, 12 states (California, Oregon, Washington, Colorado, New Mexico, Illinois, Maryland, Delaware, New Jersey, Rhode Island, Massachusetts and Vermont) and 53 local governments have added EV provisions to their building codes, local ordinances and zoning requirements. Originally published in 2022, this tech brief has been revised to align with recent model energy code committee discussions and published EV infrastructure code language. This technical brief summarizes market trends, costs and benefits, and provides sample code language for EV charging infrastructure for consideration to be included in model codes, such as the International Energy Conservation Code (IECC) and ANSI/ASHRAE/IES Standard 90.1, as well as directly by states and local governments in their building codes. The technical brief summarizes related efforts undertaken by states and local governments, and builds upon language considered during the 2021 and 2024 IECC development cycles.

2021 IECC↗

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR↗

Reconstructing gravity on cosmological scales

We present the data-driven late-time reconstruction of gravitational theories and dark energy models on cosmological scales. We showcase the power of present cosmological probes at constraining these models and quantify the knowledge of their properties that can be acquired through state of the art data. This reconstruction exploits the power of the effective field theory approach to dark energy and modified gravity phenomenology, which compresses the freedom in defining such models into a finite set of functions that can be reconstructed across cosmic times using cosmological data. We consider several model classes described within this framework and thoroughly discuss their phenomenology and data implications. In this work, we find that some models can alleviate the present discrepancy in the determination of the Hubble constant as inferred from the cosmic microwave background and as directly measured. This results in a statistically significant preference for the reconstructed theories over the standard cosmological model.

79 ASTRONOMY AND ASTROPHYSICS↗

City and County Vehicle Inventories

This light-duty vehicle inventory dataset provides information on vehicle registrations by vehicle type (car vs. truck), fuel type, and model year showing the changes in adoption trends over time and average fuel economies. This data is part of a suite of state and local energy profile data available at the "State and Local Energy Profile Data Suite" link below and builds on Cities-LEAP energy modeling, available at the "EERE Cities-LEAP Page" link below. Examples of how to use the data to inform energy planning can be found at the "Example Uses" link below.

Alternative Fuel↗

Effects of B 2 O 3 on the Growth, Structural, and Magneto-Optical Properties of Yttrium Iron Garnet Single-Crystal Fibers

This study explores the fabrication of yttrium iron garnet (YIG) single crystal fibers using the laser heated pedestal growth (LHPG) method with the experimental addition of B 2 O 3 . The incorporation of B 2 O 3 facilitates the fiber fabrication process by lowering the required growth temperatures and likely modifying melt viscosity behavior, consistent with the established fluxing behavior of B2O3 and the comparative viscosity trend observed in the TMA−VFT analysis, thereby improving process efficiency while maintaining fiber quality. Structural characterization using EBSD and SC-XRD reveals a transition from polycrystalline to single-crystal behavior, with improved alignment along the [111] direction without altering the garnet structure. Magnetic measurements show increases in saturation magnetization in B 2 O 3 -assisted fibers. Three-dimensional anisotropy energy modeling, based on EBSD-derived Euler angles, indicates that the enhanced crystallinity and orientation contribute to reorientation of MCA energy distribution due to improved crystallographic alignment. Faraday rotation measurements show that the B 2 O 3 -assisted sample exhibits a rotation angle closer to reported values for high-quality YIG, suggesting improved phase purity and crystallographic quality. These findings demonstrate that B 2 O 3 -assisted LHPG growth is a scalable and nontoxic approach to producing high-performance YIG fibers for integrated photonic and magnetic field sensing applications.

Crystal structure↗