Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Energy-Efficient, Continuous-Flow Ash Lockhopper

Pressure balance in control gas prevents loss of reactor gas. Energy efficiency of continuous-flow ash lockhopper increased by preventing hot gases from flowing out of reactor vessel through ash-hopper outlet and carrying away heat energy. Stopping loss of reactor gases also important for reasons other than energy efficiency; desired reaction product toxic or contained to prevent pollution. In improved continuous-flow ash lockhopper, pressure-driven loss of hot gas from reactor vessel through ash-hopper outlet prevented by using control gas in fluidic flow-control device to equalize pressure in reactor vessel. Also enables reactor to attain highest possible product yield with continuous processing while permitting controllable, continuous flow of ash.

Collins, Earl R., Jr.↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Energy Transport in the Thermosphere During the Solar Storms of April 2002

The dramatic solar storm events of April 2002 deposited a large amount of energy into the Earth's upper atmosphere, substantially altering the thermal structure, the chemical composition, the dynamics, and the radiative environment. We examine the flow of energy within the thermosphere during this storm period from the perspective of infrared radiation transport and heat conduction. Observations from the SABER instrument on the TIMED satellite are coupled with computations based on the ASPEN thermospheric general circulation model to assess the energy flow. The dominant radiative response is associated with dramatically enhanced infrared emission from nitric oxide at 5.3 microns from which a total of approx. 7.7 x 10(exp 23) ergs of energy are radiated during the storm. Energy loss rates due to NO emission exceed 2200 Kelvin per day. In contrast, energy loss from carbon dioxide emission at 15 microns is only approx. 2.3% that of nitric oxide. Atomic oxygen emission at 63 microns is essentially constant during the storm. Energy loss from molecular heat conduction may be as large as 3.8% of the NO emission. These results confirm the "natural thermostat" effect of nitric oxide emission as the primary mechanism by which storm energy is lost from the thermosphere below 210 km.

SOLAR STORMS↗

Analysis of atmospheric flow over a surface protrusion using the turbulence kinetic energy equation

Atmospheric flow fields resulting from a semi-elliptical surface obstruction in an otherwise horizontally homogeneous statistically stationary flow are modelled with the boundary-layer/Boussinesq-approximation of the governing equation of fluid mechanics. The turbulence kinetic energy equation is used to determine the dissipative effects of turbulent shear on the mean flow. Mean-flow results are compared with those given in a previous paper where the same problem was attacked using a Prandtl mixing-length hypothesis. Iso-lines of turbulence kinetic energy and turbulence intensity are plotted in the plane of the flow. They highlight regions of high turbulence intensity in the stagnation zone and sharp gradients in intensity along the transition from adverse to favourable pressure gradient.

Frost, W.↗

Synergistic Flow-Induced Oscillation of Multiple Cylinders in Harvesting Marine Hydrokinetic Energy

Abstract Flow-induced oscillations/vibrations (FIO/V) of cylinders in tandem can be enhanced by proper in-flow spacing to increase hydrokinetic energy harnessing. In a farm of multiple cylinders in tandem, the effect of interference on harnessing efficiency arises. Three years of systematic experiments in the Marine Renewable Laboratory (MRELab) of the University of Michigan, on an isolated cylinder, and two and three cylinders in tandem have revealed that synergistic FIO can enhance oscillations of cylinders in close proximity. Two cylinders in tandem can harness 2.5–13.5 times the hydrokinetic power of one isolated cylinder. Three cylinders in tandem can harness 3.4–26.4 times the hydrokinetic power of one isolated cylinder. Negative impact on the harnessed energy by multiple cylinders, such as the shielding effect for the downstream cylinder/s, is possible. Specifically for the three-cylinder configuration, at a certain flow speed, the decrease in the power of the middle cylinder can be overcome by adjusting its stiffness and/or damping.

Engineering↗

Volume-energy parameters and turbulent-flow density fluctuations

Volume-energy relations determined from an equation of state were used to group many sets of heat transfer data for liquids and gases, including the near-critical region. The volume - Gibbs energy parameter grouped these data better than did such other parameters as enthalpy, temperature, or internal energy.

Hendricks, R. C.↗

An exact energy corollary for homentropic flow

An exact conservation equation is developed which generalizes the familiar acoustic energy equation. The new relation is valid for arbitrary homentropic disturbances to a homentropic steady flow. It is suggested by a derivation of the acoustic energy equation by means of a regular perturbation expansion of the general energy equation for an ideal compressible fluid. A perturbation energy density and flux are defined and are identified as the exact physical quantities whose leading order representations are the usual acoustic energy density and flux.

Myers, M. K.↗

Hydrokinetic Energy Conversion by Flow-Induced Oscillation of Two Tandem Cylinders of Different Stiffness

Abstract The vortex-induced vibration for aquatic clean energy (VIVACE) converter harnesses hydrokinetic energy by enhancing flow-induced oscillations (FIOs) of elastically supported rigid cylinders in a river, tide, or ocean current. The harnessing power depends on the intensity of the oscillation, which is a consequence of the flow–structure interaction. The inflow condition for the downstream (second) cylinder is slowed down and perturbed by the upstream (first) cylinder, due to the shielding effect. Therefore, the optimal structural parameters, i.e., stiffness and damping ratio, for the second cylinder may be different from the first cylinder, in terms of energy harnessing. To improve the performance of the VIVACE converter, a series of experiments are conducted in a recirculating water channel, with various stiffness combinations of two cylinders in tandem. Results show that the stiffness of the second cylinder, K2, does not affect the energy harnessing power in vortex-induced vibration (VIV) occurring at low speeds, because the oscillation of the downstream cylinder in this velocity range is completely dominated by the wake of the upstream cylinder. K2 has a great influence on the harnessing power at higher velocities in the transition region from VIV to galloping and in galloping. Changing K2 onsets and enhances galloping at lower flow velocity and harnesses up to 110% more energy than the case of K1 = K2.

Engineering↗

Energy Transport and Conversion Above a Bright Discrete Auroral Arc

Magnetically connected observations of particle distributions and luminosity from the Reimei spacecraft are used to examine energy transport and conversion occurring above a discrete auroral arc. By combining imaging and in situ measurements it is shown how transverse electromagnetic and kinetic energy fluxes measured along the spacecraft trajectory converge across geomagnetic field-lines into the acceleration region. It is shown how cross-field energy transport is facilitated by the formation of vortices along the length of the arc. From an integration over the vertical extent of the acceleration region it is shown that the transverse and field-aligned flow of energy into the arc locally supports the dissipation needed to power the electron acceleration observed. Estimates of gradients in electromagnetic and kinetic energy flows show how field-aligned electron energization in the acceleration region is supported by the divergence of Poynting flux along and across the background magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Binder-free thin graphite fiber mat sandwich electrode architectures for energy-efficient vanadium redox flow batteries

Vanadium redox flow batteries (VRFB) are emerging as the preferred energy storage solution for long-duration energy storage (LDES) and grid-scale load levelling. In this study, we report a novel binder-free sandwich electrode architecture consisting of a thin layer (6–12 mg cm –2 ) of thermally activated graphite felt mat (TGFM) sandwiched between thin carbon papers (TCP-TGFM-TCP). This electrode architecture substantially reduced the polarization (I-V) resistance of the VRFB by 23 %, resulting in a current density increase from 340 mA cm –2 at 1 V for the thermally activated graphite felt (TGF) electrode to 470 mA cm –2 at 1 V, and an energy efficiency of 80 % at 100 mA cm –2 is realized.

25 ENERGY STORAGE↗

An artificial energy method for calculating flows with shocks

The artificial-viscosity method, first proposed by von Neumann and Richtmyer, introduces an artificial viscous pressure term in regions of compression such that an increase in entropy occurs in shock transition zones. The paper describes how dissipative flows can be induced by reducing the total energy available for adiabatic processes in shock zones. A class of inviscid fluid flows, called semiflows, is described in which the flows exhibit thermodynamic differences. Induced dissipative flows modify the pressure in regions of compression in a manner analogous to the artificial-viscosity method and for a gas, the effect is equivalent to suitably modifying the gas constant in the equation of state. By employing MacCormack's method and the usual non-adiabatic equations, numerical solutions of a Riemann problem are compared with the modified artificial energy method, showing that the dissipation effect predicted by the analytical formulation is reflected in the numerical method as well.

Rose, M. E.↗

Numerical analyses of high temperature dense, granular flows coupled to high temperature flow property measurements for solar thermal energy storage

High temperature particle flow properties necessary to predict granular flow behavior for solar thermal energy storage applications were measured and calculated for Carbobead CP 30/60 up to 800 °C. Here, the measured properties included elastic and shear moduli, particle-particle coefficients of static sliding and rolling friction, and particle-particle coefficients of restitution. Poisson’s ratio was calculated with elastic and shear moduli. The flow properties were used as inputs for a numerical model using the discrete element method to examine granular flows along an inclined plane at high temperature. The flow behavior was strongly influenced by the coefficients of static friction, which impacted the particle residence time, shear effects from the side walls, and particle flow mass flux. An 8.7%, 15.6%, and 8.5% increase and 37.9% decrease in steady state mass flow rate was observed for 200 °C, 400 °C, 600 °C, and 800 °C, respectively, when compared to room temperature simulations. A 52%, 59%, and 33% decrease in the time to reach steady state was observed for 200 °C, 400 °C, and 600 °C, respectively, while a 53% increase in time was observed for 800 °C. A significant delay in the flow development at 800 °C was observed due to significantly higher frictional forces.

14 SOLAR ENERGY↗

Preparing an Incompressible-Flow Fluid Dynamics Code for Exascale-Class Wind Energy Simulations

The U.S. Department of Energy has identified exascale-class wind farm simulation as critical to wind energy scientific discovery. A primary objective of the ExaWind project is to build high-performance, predictive computational fluid dynamics (CFD) tools that satisfy these modeling needs. GPU accelerators will serve as the computational thoroughbreds of next-generation, exascale-class supercomputers. Here, we report on our efforts in preparing the ExaWind unstructured mesh solver, Nalu-Wind, for exascale-class machines. For computing at this scale, a simple port of the incompressible-flow algorithms to GPUs is insufficient. To achieve high performance, one needs novel algorithms that are application aware, memory efficient, and optimized for the latest-generation GPU devices. The result of our efforts are unstructured-mesh simulations of wind turbines that can effectively leverage thousands of GPUs. In particular, we demonstrate a first-of-its-kind, incompressible-flow simulation using Algebraic Multigrid solvers that strong scales to more than 4000 GPUs on the Summit supercomputer.

algebraic multigrid↗

A Comparative Review of Metal-Based Charge Carriers in Nonaqueous Flow Batteries

Energy storage is becoming the chief barrier to the utilization of more renewable energy sources on the grid. With independent service operators aiming to acquire gigawatts in the next 10–20 years, there is a large need to develop a suite of new storage technologies. Redox flow batteries (RFB) may be part of the solution if certain key barriers are overcome. This review focuses on a particular kind of RFB based on nonaqueous media that promises to meet the challenge through higher voltages than the organic and aqueous variants. This class of RFB is divided into three groups: molecular, macromolecular, and redox-targeted systems. The growing field of theoretical modeling is also reviewed and discussed.

25 ENERGY STORAGE↗

High‐Energy‐Density Chelated Chromium Flow Battery Electrolyte at Neutral pH

Abstract High‐concentration operation of redox flow batteries (RFBs) is essential for increasing their energy‐storage capacity, but non‐acidic electrolytes struggle to achieve the high concentrations of metal ions dissolved in acid, limiting the development of energy‐dense neutral pH electrolytes. We report neutral pH RFB operation of chromium 1,3‐propylenediaminetetraacetate (CrPDTA) at concentrations of 1.2 M at room temperature and 1.6 M at 40 °C, demonstrating 60% higher negolyte capacity, up to 42.9 Ah L −1 , than previously reported for non‐additive‐utilizing solutions of this promising material. With extended full cell cycling, we demonstrate the importance of buffer selection and pH when using the Fumasep E‐620(K) membrane. Finally, we expand the pH operation range of CrPDTA to pH 7, which when cycled at 100 mA cm −2 against a ferrocyanide posolyte demonstrated excellent coulombic efficiencies >99.7% and energy efficiencies >87%, while operating at almost 700 mV more negative than the thermodynamic hydrogen evolution window.

Chemistry↗

Prediction of heat transfer to a thin liquid film in plane and radially spreading flows

The energy equation is incorporated in the solution algorithm of Rahman et al. (1990) to compute the heat transfer to a thin film in the presence or absence of gravity. For a plane flow under zero gravity, it is found that, for both isothermal and uniformly heated walls, the heat transfer coefficient gradually decreases downstream, with Nu-asterisk (the Nusselt number in terms of film height) remaining approximately constant except for regions very close to the entrance. In the case of radial flow under zero gravity, Nu-asterisk is found to decrease monotonically when the plane is uniformly heated. Two different flow regimes are identified in the presence of gravity for both plane and radial flows. The results of the study may be applicable to the design of space-based cooling systems.

Rahman, M. M.↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗