Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emissions control technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Soil Sample Workplan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit (Part V, Special Condition #14 a-f)

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semi-volatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 7 and 8. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. Nitrate and all CAM17 metals have been added to the sampling plan to comply with DTSC comments received in correspondence dated June 4, 2021. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impurity screening behavior of the high-field side scrape-off layer in near-double-null configurations: prospect for mitigating plasma-material interactions on RF actuators and first-wall components

The impurity screening response of the high-field side (HFS) scrape-off layer (SOL) to localized nitrogen injection is investigated on Alcator C-Mod for magnetic equilibria spanning lower-single null, double-null and upper single null configurations under otherwise identical plasma conditions. L-mode, EDA H-mode and I-mode discharges are investigated. HFS impurity screening is found to depend on magnetic flux balance and the direction of B×?B relative to the most active divertor. Impurity ‘plume’ emission patterns indicate that both parallel and perpendicular (E×B) flows in the SOL contribute to the ‘flushing’ of impurities towards the active divertor, thereby affecting the overall impurity screening behavior. Despite the fact that the HFS scrape-off layer is extremely narrow in near-double-null configurations, this SOL is able to screen locally injected nitrogen at least as effectively as the low-field side (LFS) SOL – up to a factor of 10 more effective, depending on specific plasma conditions and whether the magnetic geometry produces parallel flows that work with or against E×B flows. For situations in which the E×B drift of the impurity ions opposes parallel flow toward the primary divertor, HFS impurity screening is found to be least effective. When E×B drifts assist parallel flow toward the primary divertor, HFS impurity screening is found to be very effective. These data support the idea of placing RF actuators and close-fitting wall components on the high-field side of the tokamak. With this configuration, near-double-null magnetic topologies may be used for active control of plasma parameters at the antenna/plasma interface for optimal RF coupling, mitigate the generation of local impurities from plasma-material interactions and, taking advantage of favorable plasma flows and good screening properties of the HFS SOL, further minimize the impact of wall-born impurity sources on the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Floating Island International PHASE I FINAL TECHNICAL REPORT (Advancing the Development of Floating Solar-Powered Nanobubble Aeration Systems for Use with Floating Treatment Wetlands in Natural and Man-Made Waterbodies)

More and more freshwater lakes are suffering from algae blooms, which deprive water of oxygen and lead to widespread loss of aquatic life and production of dangerous toxins. When oxygen is lacking, methane is generated in the sediments as algae is decomposed; it has been calculated that more than half of global methane emissions come from nutrient-impaired freshwater systems (Beaulieu, 2021). Nutrients, mainly from agricultural run-off, feed algae blooms and are exacerbated by warming related to climate change. Artificial aeration is frequently used to restore oxygen to a waterbody. But diffuser aeration is inefficient and expensive, needs on-site grid power, and is failing to keep pace with the demands of water as it gets warmer with climate change. In the last five years, nanobubble aeration has been introduced into freshwater applications and shows promise for rapidly increasing dissolved oxygen effectively throughout the water column. Nanobubbles deliver oxygen in bubbles that have no buoyancy, so they stay in water longer and release their oxygen more fully, compared to large bubbles that rise and burst at the surface. The prospect of this new technology answering the deficiencies of diffuser aeration drove us to initiate the current project. During our Phase I period, we have successfully tested a nanobubble aeration system that can super-saturate oxygen levels. It is operated on solar power, and both the nanobubbler and solar array are mounted on a proprietary floating island platform, that also performs biological nutrient recycling. A rudimentary system was assembled and tested on a 6.5-acre research lake at our headquarters in Montana, where it was subjected to a summer drought that reduced water levels significantly, periods of severe cold in winter, and spring conditions that included heavy rainfall and violent thunderstorms. Our twice-weekly sampling throughout the project showed that dissolved oxygen levels rose rapidly and were maintained throughout winter and spring, well into June. The nanobubbler was able to run on solar power for long periods. Methane levels were tested periodically and found to decrease as oxygen increased. The nanobubbles appeared to have no adverse impact on fish or other aquatic life exposed to them. The stability of the installation survived the weather conditions. The many problems we encountered taught us what we need to improve in the next iteration. Towards the end of our Phase I, we were awarded a supplementary state grant that enabled us to acquire a new nanobubble system for testing that runs on DC, is extremely efficient and has few moving parts. We plan to team this with low-profile solar panels, lithium batteries and a controller that provides real-time data. The ultimate goal of this project is to commercialize an affordable and scalable lake management system that will oxygenate water from the surface down to the sludge. It will enliven fisheries, prevent toxic algae blooms and – most importantly for the fate of our planet - inhibit the production and release of methane from the sediments. We anticipate that as carbon credits expand to include methane, the cost of remediating waterbodies that produce methane will be offset. We firmly believe that this is a practical technology that works and will make a big difference when fully implemented.

14 SOLAR ENERGY↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-fidelity modeling of breakdown in helium: initiation processes and secondary electron emission

Understanding the role of physical processes contributing to breakdown is critical for many applications in which breakdown is undesirable, such as capacitors, and applications in which controlled breakdown is intended, such as plasma medicine, lightning protection, and materials processing. The electron emission from the cathode is a critical source of electrons which then undergo impact ionization to produce electrical breakdown. In this study, the role of secondary electron yields due to photons (γ ph ) and ions (γ i ) in direct current breakdown is investigated using a particle-in-cell direct simulation Monte Carlo model. The plasma studied is a one-dimensional discharge in 50 Torr of pure helium with a platinum cathode, gap size of 1.15 cm, and voltages of 1.2–1.8 kV. The current traces are compared with experimental measurements. Larger values of γ ph generally result in a faster breakdown, while larger values of γ i result in a larger maximum current. The 58.4 nm photons emitted from He(2 1 P) are the primary source of electrons at the cathode before the cathode fall is developed. Of the values of γ ph and γ i investigated, those which provide the best agreement with the experimental current measurements are γ ph = 0.005 and γ i = 0.01. In this work, these values are significantly lower than those in the literature for pristine platinum or for a graphitic carbon film which we speculate may cover the platinum. This difference is in part due to the limitations of a one-dimensional model but may also indicate surface conditions and exposure to a plasma can have a significant effect on the secondary electron yields. The effects of applied voltage and the current produced by a UV diode which was used to initiate the discharge, are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tailoring Cementitious Materials Towards Value-Added Use of Large CO 2 Volumes

Hydraulic cements with alternative chemistries were developed for large-volume and value-added use of carbon dioxide. The hydraulic cements were processed using the energy-efficient mechanochemical technique at room temperature and atmospheric pressure. Carbon dioxide was captured directly from combustion emissions during processing. For this purpose, mechanochemical processing of hydraulic cements was accomplished under a flow of combustion emissions prior to the release of emissions to the atmosphere. The process removed a significant fraction of carbon dioxide from combustion emissions. The hydraulic cements captured carbon dioxide at about 10% of their weight. Two hydraulic cement chemistries were developed, and their mechanochemical processing was successfully scaled-up. The characteristic feature of one chemistry was its relatively low (near-neutral) pH where the integration of carbon dioxide yielded clear value. The second cement chemistry was based on alkali activation of industrial wastes. This chemistry could make value-added use of carbon dioxide, but it had to be refined to control the pH drop caused by CO 2 integration. These two cements render binding effects upon hydration by forming a combination of stable carbonates and aluminosilicates or phosphates. Efforts to develop cement chemistries based solely on carbonates were not successful. The mechanochemical process was found to integrate carbon dioxide into the alternative cement chemistries in the form of disordered and metastable carbonates. During hydration reactions, the disordered/metastable carbonates are either transformed into stable carbonate phases with desired binding efforts, or carbonates get integrated into the primary inorganic binders (hydrates). When compared with mechanochemical processing in pure carbon dioxide, mechanochemical processing in combustion emissions produced hydraulic cements with improved engineering properties. The mechanochemical process was scaled-up, and its variables as well as the raw materials formulations were optimized for implementation at pilot scale. Scale-up was found to enhance the carbon capture potential and the engineering qualities of the resulting hydraulic cements. This was because scale-up raises the intensity of mechanical energy input to raw materials. Certain mechanochemical phenomena cannot be induced, irrespective of the cumulative mechanical energy input, unless the intensity of impact is raised above a minimum level that cannot be achieved in laboratory-scale implementation of the process. Due to this effect, the duration of the mechanochemical process as well as its energy demand could be reduced significantly (by an order of magnitude) upon transition from laboratory to pilot scale, with the hydraulic cements produced at pilot scale offering engineering properties that were superior to those realized in laboratory-scale mechanochemical processing. The hydraulic cements produced at pilot scale via mechanochemical processing under a flow of combustion emissions were thoroughly characterized. They were found to meet standard requirements for ‘General Use’ hydraulic cements. They were compatible with the industrial-scale concrete production and construction practices that are used with the currently prevalent hydraulic cements. The new hydraulic cements with integrated carbon dioxide were found to offer distinct advantages over the currently prevalent Portland cement in terms of net carbon footprint and energy content. The combined raw materials and energy costs of the new hydraulic cements are competitive, and major cost savings can be realized because of the simplified production process that significantly lowers the capital investment in cement production plants. Mechanochemical processing of the new hydraulic cements under a flow of combustion emissions can be implemented using some existing components of cement manufacturing plants; this facilitates adoption of the technology by the cement industry.

36 MATERIALS SCIENCE↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propagation of ion cyclotron emission in the DIII-D tokamak

Experiments in L- and H-mode plasmas performed on the DIII-D tokamak explored ion cyclotron emission (ICE) propagation via the recently upgraded ICE diagnostic. The distance between the plasma and the outer wall was scanned to alter the evanescent region, which was seen to impact the detection of runaway electron-driven whistler modes in a comparable frequency range to typical ICE harmonics (f≳10fci) [Heidbrink et al., Plasma Phys. Controlled Fusion 61, 014007 (2018)]. In L-mode plasmas, core ICE did not exhibit clear trends as the plasma-wall distance was altered. Instead, inadvertent changes to the fast ion density correlated with different ICE fine structures; the most spectral bands (spaced ∼150–200 kHz apart) were observed at the highest fast ion density, and a just single band when nfast decreased by ∼ 40%. The full-wave Petra-M code simulated core ICE propagation through the plasma and to ICE probes, agreeing with experimental findings that these are likely compressional fast waves, which propagate to probe locations with no dependence on plasma-wall gap. Edge ICE in H-mode plasmas was similarly unaffected by plasma-wall distance. Unlike in core ICE cases, there were negligible changes to the edge fast ion distribution and edge bulk plasma profiles. However, changes in ELM frequency seemed most closely tied to ICE behavior. Ultimately, core and edge ICE did not exhibit clear dependencies on the plasma-wall distance, and ICE harmonics were observed with even the largest plasma-wall gaps. This independence bodes well for similar diagnostics in future tokamaks, which might be placed further from high radiation areas without adversely impacting measurement capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust highly durable solid oxide fuel cell cathodes – Improved materials compatibility & self-regulating surface chemistry

Solid oxide fuel cells (SOFCs) are electrochemical conversion devices that directly transform hydrogen or hydrocarbon fuels to electricity, with energy efficiencies as high as 90%, coupled with reduced emissions. Several factors, however, remain to be addressed when considering scale-up of SOFC technology, including the need to overcome decreased performance due to sluggish rates of the oxygen reduction reaction (ORR) at the cathode under reduced temperatures and susceptibility to degradation in performance from surface poisoning e.g. from chromia, while limiting the use of critical raw materials (lanthanides and transition metals) present in high performing mixed ionic electronic conducting electrodes like (La,Sr)CoO 3 (LSC). In this project we explored the key descriptors for determining ORR activity in SOFC electrodes and tried to recover performance degradation by applying them to SOFC electrodes. In order to do this, we first selected a model mixed ionic electronic conducting (MIEC) oxide, Pr-doped CeO 2 (Pr 0.1 Ce 0.9 O 2-δ , PCO), which is a chemically stable fluorite and free of inherent poison sources (e.g. Sr segregation in LSC) that potentially react with external impurities such as Cr-species vaporized from the interconnect. The three approaches originally planned in this project are as follows: 1) evaluation of scavenger exsolution characteristics, 2) study of scavengers gettering efficacy following Cr and Si poisoning and 3) integration of new compositions into porous electrodes. Among them, exceptional progress has been made in 2) and 3), especially understanding the role of surface infiltrants in impacting electrode performance and degradation of PCO materials. We found that the Smith acidity scale for binary oxides serves as a powerful descriptor for tuning and predicting the oxygen exchange kinetics on MIEC PCO surfaces. As a result, with infiltration with binary oxides, ranging from strongly basic (Li 2 O) to strongly acidic (SiO 2 ) onto the surface of porous PCO, it was possible to systematically vary the chemical surface exchange coefficient (k chem ) by 6 orders of magnitude! L i2 O increased k chem by nearly 1,000 times over that of pristine PCO, while SiO 2 decreased k chem by nearly the same factor. Strikingly, although the pre-exponential of k chem scales linearly with the acidity of the infiltrated binary oxide, there is nearly no change in the activation energy. With this insight, we attributed the origin of these dramatic changes in k chem values to the systematic increase and decrease in the surface electron density induced by infiltrated binary oxides. More interestingly, although both Cr 2 O 3 and SiO 2 were determined to be acidic by Smith, suggesting that this feature could likely be the primary reason that these compounds serve to poison the ORR on SOFC cathodes, the effect of poisoning could be subsequently tuned by adding multiple infiltrants and controlling their relative surface acidities. We also systematically examined the effect of serial infiltration of basic and acidic oxides. It turned out that serial infiltration of Li not only recovers approximately 20-fold degraded k chem of PCO by acidic Cr 2 O 3 but its k chem is enhanced even beyond that of the non-infiltrated PCO by more than three orders of magnitude. This was further verified with a screen-printing PCO symmetric cell in terms of the electrode performance (area-specific resistance, ASR) related to approach 3). These observations point to acidity as a key descriptor not only in tuning and predicting the ORR activity of SOFC cathodes that largely determines the overall performance of SOFC, but in mitigating and reactivating poisoned electrode performance. This work provides novel guidelines for making the electrode performance much more active and robust in SOFCs, which can further be applied to all applications requiring oxygen exchange reaction, such as electrolyzers, permeation membranes and gas sensors.

30 DIRECT ENERGY CONVERSION↗

The Impact of Carotenoid Energy Levels on the Exciton Dynamics and Singlet–Triplet Annihilation in Isolated Bacterial Light-Harvesting 2 Complexes

The light-harvesting 2 (LH2) complex of purple phototrophic bacteria plays a critical role in absorbing solar energy and distributing the excitation energy. Exciton dynamics within LH2 complexes are controlled by the structural arrangement and energy levels of the bacteriochlorophyll (BChl) and carotenoid (Car) pigments. However, there is still debate over the competing light-harvesting versus energy-dissipation pathways. In this work, we compared five variants of the LH2 complex from genetically modified strains of Rhodobacter sphaeroides, all containing the same BChls but different Cars with increasing conjugation: zeta-carotene (N = 7; LH2 Zeta ), neurosporene (N = 9; LH2 Neu ), spheroidene (N = 10; LH2 Spher ), lycopene (N = 11; LH2 Lyco ), and spirilloxanthin (N = 13; LH2 Spir ). Absorption measurements confirmed that the Car excited-state energy decreased with increasing conjugation. Similarly, fluorescence spectra showed that the B850 BChl emission peak had an increasing red shift from LH2 Zeta →(LH2 Neu /LH2 Spher )→LH2 Lyco →LH2 Spir . In contrast, time-resolved fluorescence and ultrafast transient absorption (fs-TA) revealed similar excited-state lifetimes (∼1 ns) for all complexes except LH2 Spir (∼0.7 ns). From fs-TA analysis, an additional ∼7 ps nonradiative dissipation step from B850 BChl was observed for LH2 Zeta . Further, singlet− singlet and singlet−triplet annihilation studies showed a ∼50% average fluorescence lifetime reduction in LH2Zeta at high laser power and high repetition rate, compared to ∼10−15% reductions in LH2 Neu /LH2 Spher /LH2 Lyco and minimal lifetime change in LH2 Spir . In LH2 Zeta , the fastest decay component (<50 ps) became prominent at high repetition rates, consistent with strong singlet−triplet annihilation. Nanosecond TA measurements revealed long-lived (>40 μs) BChl triplet states in LH2 Zeta and signs of damage caused by singlet oxygen, whereas other LH2s showed faster triplet quenching (∼18 ns) by Cars. These findings highlight a key design principle of LH2 complexes: the Car triplet energy must be significantly lower than the BChl triplet energy to efficiently quench BChl triplets that otherwise act as potent “trap states,” causing exciton annihilation in laser-based experiments or photodamage in native membranes.

Absorption↗

Plasma assisted NH 3 /H 2 /air ignition in nanosecond discharges with non-equilibrium energy transfer

Ammonia (NH 3 ), with its high energy density and easiness to store and transport as a hydrogen carrier, has become a promising alternative green fuel. However, its adoption in power generation is hindered by challenges such as low burning velocity, slow low-temperature oxidation, high NO x emissions, and ignition difficulty. Here, this work computationally investigates the effects of non-equilibrium energy transfer by nanosecond discharges on NH 3 ignition and flame propagation in an NH 3 /H 2 /air flow at 700 K and 1 atm. The simulation results demonstrate that NH 3 /air mixtures require a large ignition energy due to their large critical ignition radius. It is shown that adding 30 % hydrogen significantly reduces the critical ignition radius and minimum ignition energy. Two-dimensional modeling further shows a non-monotonic dependence of ignition kernel volume on the applied voltage and reduced electric field. The optimum ignition enhancement occurs at 200 Td where the generation of electronically excited species and radicals including N 2 (B), O( 1 D) and OH becomes most efficient. Higher voltages divert electron energy toward ionization, which makes it less effective for NH 3 ignition. The study also identifies an optimal electrode gap size for a given pulse energy. Smaller gap sizes increase deposited energy density, raising temperature and radical concentrations. However, excessive reduction of the gap distance reduces flame propagation speed due to the flame stretch effect in rich mixtures with the effective Lewis number greater than unity. A nonlinear relationship between pulse repetition frequency and ignition kernel volume is observed in a nanosecond pulsed high frequency discharge (NPHFD). An optimal frequency range of 200 kHz to 2 MHz is found when two pulses are used. In addition, an optimal number of pulses exists for each pulse repetition frequency, with higher frequencies requiring more pulses to maximize the overlap region. These findings provide critical insights on developing controlled plasma discharge techniques for efficient NH 3 ignition in reactive flows within internal combustion engines and gas turbines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗