Circularly Polarized Stimulated Emission from a Chiral Cavity Based on Apparent Circular Dichroism Organic Thin-Films
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.
The photoluminescence (PL) of a novel imide-substituted poly(3-thienylenevinylene) derivative (imidePTV) was studied in film and solution. PL quantum efficiency was measured to be more than two orders of magnitude larger than its nonluminescent counterpart, namely, alkyl-substituted PTV and was interpreted as evidence for a near degeneracy of optically allowed 1{sup 1}B{sub u} and optically forbidden 2{sup 1}A{sub g} excitonic states. As a result, coexistence of 2{sup 1}A{sub g} and 1{sup 1}B{sub u} emissions was observed, and the predominance was found to be sensitive to temperature and morphological environment. PL of solutions in solvents of higher polarity and polarizability and from low-temperature films was dominated by the transition from the dipole allowed 1{sup 1}B{sub u} state. On the other hand, the PL spectra of films at high temperature and solutions in solvents of low polarity and polarizability were primarily from the 2{sup 1}A{sub g} state that obtains a finite transmission moment from an asymmetric perturbation mixing with the 1{sup 1}B{sub u}.
In this study, the close physical proximity of the Gas Puff Imaging (GPI) and Beam Emission Spectroscopy (BES) diagnostics on the National Spherical torus Experiment (NSTX) is leveraged to directly compare fluctuation measurements, and to study the local effects of the GPI neutral deuterium puff during H-mode plasmas without large Edge Localized Modes. The GPI and BES views on NSTX provide partially overlapping coverage of the edge and scrape-off layer (SOL) regions above the outboard midplane. The separation in the toroidal direction is 16°, and field lines passing through diagnostic views are separated by ∼20 cm in the direction perpendicular to the magnetic field. Strong cross-correlation is observed, and strong cross-coherence is seen for frequencies between 5 and 15 kHz. Also, probability distribution functions of fluctuations measured ∼3 cm inside the separatrix exhibit only minor deviations from a normal distribution for both diagnostics, and good agreement between correlation length estimates, decorrelation times, and structure velocities is found at the ±40% level. While the two instruments agree closely in many respects, some discrepancies are observed. Most notably, GPI normalized fluctuation levels exceed BES fluctuations by a factor of ∼9. BES mean intensity is found to be sensitive to the GPI neutral gas puff, and BES normalized fluctuation levels for frequencies between 1 and 10 kHz are observed to increase during the GPI puff.
Explore the source record for details and available documents.
Laser-induced periodic surface structuring is a powerful technique for modifying the surface properties of solids. Using ultrashort pulses from a Ti:Sapphire laser (800 nm, 100 fs) we have fabricated nanoscale order laser-induced periodic surface structures (LIPSS) on a silicon (100) surface. The LIPSS patterns are found to be strongly dependent on the laser pulse energy, state of polarization, number of shots delivered on the target, and the ambient pressure. The role of laser wavelength is studied by using the second harmonic output (400 nm) also for fabrication. Large area (5x4 mm2) surface structuring has been carried out at atmospheric pressure after optimizing the laser parameters at 800 nm. The patterned silicon surface shows a substantial reduction in the reflection of incident light over a wide range of wavelengths, in comparison to plain silicon. Moreover, when used for laser induced breakdown spectroscopy (LIBS) experiments, enhanced optical emission and ion current have been observed from the patterned surface. This indicates that coupling of laser energy to the surface is enhanced in the case of patterned silicon. While spectral lines emitted by doubly ionized silicon have been observed from the patterned surface, the plain surface gives lines from singly ionized silicon only. A discernible enhancement has been measured in both optical (50-90%) and electrical (34%) signals from the plasma generated on the patterned surface. These results confirm that LIPSS is a versatile method for enhancing the coupling of laser energy on to irradiated solid surfaces.
Using electron emission spectroscopy, measurement and analysis were conducted on the energy distribution of vacuum emitted electrons from electrically driven InGaN/GaN green (peak wavelengths 𝜆 ≈ 515nm) light-emitting diodes (LEDs) with and without a prewell superlattice (SL). Here, we report on the detection of a high-energy upper valley at ∼ 1.7eV above the Γ valley from samples with no prewell SL. We propose that these upper valley electrons originate predominantly from trap-assisted Auger recombination (TAAR) in green LEDs, as the intensity of these peaks is found to have quadratic dependence on the carrier density 𝑛 [see Espenlaub et al., J. Appl. Phys. 126, 184502 (2019)]. The high-energy upper valley peak was not observed in the sample with a prewell SL which is attributed to gettering by the prewell SL of still unidentified impurities that act as TAAR centers.
A model-independent, three-dimensional source function for pion pairs has been extracted from Pb + Pb collisions at {radical}s{sub NN} = 17.3 GeV. The extracted source exhibits long-range non-Gaussian tails in the directions of the pion-pair net transverse momentum and of the beam. Comparison with the Therminatormodel allows for an extraction of the pion source proper breakup time and of emission duration in the collisions.
The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas.
This project has characterized the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with varied geometries. The overall goal of the project has been to evaluate CNT forest cathodes as a potential replacement for thermionic cathodes currently used in accelerator systems.
DayCent data and results for:J. L. Field, T. L. Richard, E. A. Smithwick, H. Cai, M. S. Laser, D. S. LeBauer, S. P. Long, K. Paustian, Z. Qin, J. J. Sheehan, P. Smith, M. Q. Wang, L. R. Lynd, Robust paths to net greenhouse gas mitigation and negative emissions via advanced biofuels. Proceedings of the National Academy of Sciences (2020). https://doi.org/10.1073/pnas.1920877117 This zip file contains a UNIX-format DayCent model executable, input files, automation code, and associated directory structure necessary to re-produce the DayCent analysis underlying the manuscript. The main script 'autodaycent.py' (written for Python 2.7) opens an interactive command line routine that facilitates:* Calibrating the DayCent pine growth model.* Initializing DayCent for a set of case studies sites.* Executing an ensemble of model runs representing case study site reforestation, grassland restoration, or conversion to switchgrass cultivation. * Results analysis & generation of manuscript Fig. 3. Note that the interactive analysis code requires that all input files to be contained in the directory structure as uploaded, without modification. Executable versions of the DayCent model (https://www.nrel.colostate.edu/projects/daycent/) compatible with other operating systems are available upon request.Please send questions/comments to John.L.Field@gmail.com
Resonance polarization theory to set limits on degree of polarization expected from coronal emission lines
Details on the resulting scaling factors were published in a 2013 Nassar et al. paper in JGR - Atmospheres
Importance: Tau positron emission tomography (PET) tracers have proven useful for the differential diagnosis of dementia, but their utility for predicting cognitive change is unclear. Objective: To examine the prognostic accuracy of baseline fluorine 18 ( 18 F)-flortaucipir and [18F]RO948 (tau) PET in individuals across the Alzheimer disease (AD) clinical spectrum and to perform a head-to-head comparison against established magnetic resonance imaging (MRI) and amyloid PET markers. Design, setting, and participants: This prognostic study collected data from 8 cohorts in South Korea, Sweden, and the US from June 1, 2014, to February 28, 2021, with a mean (SD) follow-up of 1.9 (0.8) years. A total of 1431 participants were recruited from memory clinics, clinical trials, or cohort studies; 673 were cognitively unimpaired (CU group; 253 [37.6%] positive for amyloid-β [Aβ]), 443 had mild cognitive impairment (MCI group; 271 [61.2%] positive for Aβ), and 315 had a clinical diagnosis of AD dementia (315 [100%] positive for Aβ). Exposures: [ 18 F]Flortaucipir PET in the discovery cohort (n = 1135) or [ 18 F]RO948 PET in the replication cohort (n = 296), T1-weighted MRI (n = 1431), and amyloid PET (n = 1329) at baseline and repeated Mini-Mental State Examination (MMSE) evaluation. Main outcomes and measures: Baseline [ 18 F]flortaucipir/[ 18 F]RO948 PET retention within a temporal region of interest, MRI-based AD-signature cortical thickness, and amyloid PET Centiloids were used to predict changes in MMSE using linear mixed-effects models adjusted for age, sex, education, and cohort. Mediation/interaction analyses tested whether associations between baseline tau PET and cognitive change were mediated by baseline MRI measures and whether age, sex, and APOE genotype modified these associations. Results: Among 1431 participants, the mean (SD) age was 71.2 (8.8) years; 751 (52.5%) were male. Findings for [ 18 F]flortaucipir PET predicted longitudinal changes in MMSE, and effect sizes were stronger than for AD-signature cortical thickness and amyloid PET across all participants (R 2 , 0.35 [tau PET] vs 0.24 [MRI] vs 0.17 [amyloid PET]; P < .001, bootstrapped for difference) in the Aβ-positive MCI group (R2, 0.25 [tau PET] vs 0.15 [MRI] vs 0.07 [amyloid PET]; P < .001, bootstrapped for difference) and in the Aβ-positive CU group (R 2 , 0.16 [tau PET] vs 0.08 [MRI] vs 0.08 [amyloid PET]; P < .001, bootstrapped for difference). These findings were replicated in the [ 18 F]RO948 PET cohort. MRI mediated the association between [ 18 F]flortaucipir PET and MMSE in the groups with AD dementia (33.4% [95% CI, 15.5%-60.0%] of the total effect) and Aβ-positive MCI (13.6% [95% CI, 0.0%-28.0%] of the total effect), but not the Aβ-positive CU group (3.7% [95% CI, -17.5% to 39.0%]; P = .71). Age (t = -2.28; P = .02), but not sex (t = 0.92; P = .36) or APOE genotype (t = 1.06; P = .29) modified the association between baseline [ 18 F]flortaucipir PET and cognitive change, such that older individuals showed faster cognitive decline at similar tau PET levels. Conclusions and relevance: The findings of this prognostic study suggest that tau PET is a promising tool for predicting cognitive change that is superior to amyloid PET and MRI and may support the prognostic process in preclinical and prodromal stages of AD.
Not provided.
Not provided.