Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Electro-optical characterization of the Tektronix TK512M-011 charge-coupled device

An electrooptical characterization encompassing linearity, blooming, dark-count rate, charge-transfer efficiency (CTE), and quantum efficiency, is presented for a front/side-illuminated CCD with 512x512 format and 27x27-micron pixels. The detailed noise characteristics of the CCD-output FET are reported. While very good low light level CTE is obtained in the parallel-shift direction, CTE problems arise in the serial direction. The output FET noise is equivalent to 5-12 electrons, depending on FET operating conditions and system bandwidth.

Epperson, Patrick M.↗

Design of low noise, high performance X-ray charge-coupled-device cameras

This paper describes some of the critical details of the MIT X-ray CCD camera design. Special attention is given to those portions of the system that deviate from conventional practice in the design of CCD cameras. Furthermore, an attempt has been made to generalize the design so that both optical and X-ray requirements can be satisfied whenever possible. Currently, noise levels of less than 8 electrons rms are routinely achieved with this design, and even lower levels (less than 5 electrons) should be realizable.

Doty, J. P.↗

The 32-GHz performance of the DSS-14 70-meter antenna: 1989 configuration

The results of preliminary 32 GHz calibrations of the 70 meter antenna at Goldstone are presented. Measurements were done between March and July 1989 using Virgo A and Venus as the primary efficiency calibrators. The flux densites of theses radio sources at 32 GHz are not known with high accuracy, but were extrapolated from calibrated data at lower frequencies. The measured value of efficiency (0.35) agreed closely with the predicted value (0.32), and the results are very repeatable. Flux densities of secondary sources used in the observations were subsequently derived. These measurements were performed using a beamswitching radiometer that employed an uncooled high-electron mobility transistor (HEMT) low-noise amplifier. This system was installed primarily to determine the performance of the antenna in its 1989 configuration, but the experience will also aid in successful future calibration of the Deep Space Network (DSN) at this frequency.

Gatti, M. S.↗

Wide-bandwidth high-resolution search for extraterrestrial intelligence

Research accomplished during the third 6-month period is summarized. Research covered the following: dual-horn antenna performance; high electron mobility transistors (HEMT) low-noise amplifiers; downconverters; fast Fourier transform (FFT) array; and backend 'feature recognizer' array.

Horowitz, Paul↗

The Space Telescope imaging spectrograph 2048 CCD and its characteristics

Development of a 2048-squared CCD for a second-generation Space Telescope instrument has produced some very encouraging devices. The first experimental lot of 10 devices have very few defects, dark currents of less than 40 electrons/pixel/hour at -80 C, readout noise levels of less than 4 electrons rms and excellent charge transfer efficiency at signal levels of less than 10 electrons.

Delamere, W. A.↗

A cryogenic seven-element HEMT front end for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

Bowen, J.↗

CCDs and photon counting devices: Applications in space and from the ground

The development of the 2048 by 2048 CCD (Charge Coupled Device) for a second generation space telescope instrument has resulted in devices with very few defects, dark currents of less than 12 electrons/pixel/hour at -80 deg, readout noise levels of less than 4 electrons rms, and excellent charge transfer efficiency at signal levels of less than 10 electrons. A second generation of devices that capitalize on these characteristics have been produced and are currently in test. Faster frame transfer devices that preserve these characteristics have been designed that include tridirectional taps in the serial register. The state of the art in CCD's as photon counting detectors is reviewed.

Delamere, W. A.↗

Hubble Space Telescope Program on STS-95 Supported by Space Acceleration Measurement System for Free Flyers

John Glenn's historic return to space was a primary focus of the STS 95 space shuttle mission; however, the 83 science payloads aboard were the focus of the flight activities. One of the payloads, the Hubble Space Telescope Orbital System Test (HOST), was flown in the cargo bay by the NASA Goddard Space Flight Center. It served as a space flight test of upgrade components for the telescope before they are installed in the shuttle for the next Hubble Space Telescope servicing mission. One of the upgrade components is a cryogenic cooling system for the Near Infrared Camera and Multi-Object Spectrometer (NICMOS). The cooling is required for low noise in the receiver's sensitive electronic instrumentation. Originally, a passive system using dry ice cooled NICMOS, but the ice leaked away and must be replaced. The active cryogenic cooler can provide the cold temperatures required for the NICMOS, but there was a concern that it would create vibrations that would affect the fine pointing accuracy of the Hubble platform.

Kacpura, Thomas J.↗

High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

Microchannel plates high frequency performance↗

WFIRST Coronagraph Detector Trap Modeling Results and Improvements

The WFIRST coronagraph is being designed to detect and characterize mature exoplanets through the starlight reflected from their surfaces and atmospheres. The light incident on the detector from these distant exoplanets is estimated to be on the order of a few photons per pixel per hour. To measure such small signals, the project has baselined the CCD201 detector made by e2v, a low-noise and high-efficiency electron-multiplying charge-coupled device (EMCCD), and has instituted a rigorous test and modeling program to characterize the device prior to flight. An important consideration is detector performance degradation over the proposed mission lifetime due to radiation exposure in space. To quantify this estimated loss in performance, the project has built a detector trap model that takes into account detailed trap interactions at the sub-pixel level, including stochastic trap capture and release, and the deferment of charge into subsequent pixels during parallel and serial clocking of the pseudo-two-phase CCD201 device. This paper describes recent detector trap model improvements and modeling results.

Holland, Andrew↗

Acceleration of electrons outside flares - Coronal manifestation and possible origin

Imaging observations at decimetric and metric wavelengths of the solar corona are used to investigate a short-lasting noise storm and the associated changes of the underlying active-region plasma. It is shown that a new source appears in the active region in close temporal and spatial coincidence with the onset of the noise storm in the middle corona. The onset of the noise storm is delayed at longer wavelengths. At a given wavelength, the noise-storm source undergoes a systematic slow movement with a significant component perpendicular to the magnetic-field lines above the active region. The observations are tentatively attributed to the emission of nonthermal electrons in a system of expanding coronal loops, the expansion being initiated by the appearance of the new 21-cm source in the low atmosphere. The derived velocity of expansion is about 80 to 150 km/s. The electrons emitting the noise storm cannot be provided by the high-energy tail of the Maxwellian in the new active region source, but originate either from a nonthermal population in this source or from acceleration at higher altitudes, in the structures which give rise to the noise storm.

Raulin, J. P.↗

Upgrade of the helically symmetric experiment Thomson scattering diagnostic suite

The Helically Symmetric eXperiment (HSX) Thomson Scattering (TS) diagnostic is being upgraded to decrease uncertainty in electron temperature and density measurements. Upgrades to the HSX TS diagnostic will consist of a novel redesign of polychromator electronics and digitization of the TS output signal. Here, we also present a study of the benefits of an additional spectral channel that will sample the red-shifted band of the scattered spectrum. In conclusion, to maximize system bandwidth (BW) and gain, while minimizing noise, the existing low-BW polychromator electronics on HSX will be replaced by high-BW, high gain circuitry designed in-house.

47 OTHER INSTRUMENTATION↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Airborne Visible/Infrared Imaging Spectrometer Data of the Mountain Pass, California carbonatite complex

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of the Mountain Pass, California carbonatite complex were examined to evaluate the AVIRIS instrument performance and to explore alternative methods of data calibration. Although signal-to-noise estimates derived from the data indicated that the A, B, and C spectrometers generally met the original instrument design objectives, the S/N performance of the D spectrometer was below expectations. Signal-to-noise values of 20 to 1 or lower were typical of the D spectrometer and several detectors in the D spectrometer array were shown to have poor electronic stability. The AVIRIS data also exhibited periodic noise, and were occasionally subject to abrupt dark current offsets. Despite these limitations, a number of mineral absorption bands, including CO3, Al-OH, and unusual rare earth element bands, were observed for mine areas near the main carbonatite body. To discern these bands, two different calibration procedures were applied to remove atmospheric and solar components from the remote sensing data. The two procedures, referred to as the single spectrum and the flat field calibration methods gave distinctly different results. In principle, the single spectrum method should be more accurate; however, additional fieldwork is needed to rigorously determine the degree of calibration success.

Crowley, James↗

Annoyance judgements of aircraft with and without acoustically treated nacelles

A series of subjective response laboratory tests were conducted to determine the effectiveness of reducing aircraft noise by treating the aircraft engine nacelles with acoustically absorbent material. A total of 108 subjects participated in the magnitude estimation tests. The subjects were selected from persons who had previously been interviewed and classified according to selected psychological characteristics. The subjects lived in three general areas located at three specified distances from New York's Kennedy Airport. The aircraft signals used in the tests consisted of tape recordings of the landing approach noise of a B-727 aircraft under normal operating conditions. These recordings were electronically altered to simulate an aircraft with acoustically treated nacelles to achieve noise reductions of approximately 6 EPNdB and 12 EPNdB. The results from these tests indicate that significant reductions in annoyance resulted from the synthesized nacelle treatments.

Borsky, P. N.↗

Calculation and observation of thermal electrostatic noise in solar wind plasma

Calculations, both approximate algebraic and numerical, have been carried out for the noise due to electrostatic waves incident on a dipole antenna. The noise is calculated both for a thermal equilibrium plasma, and one having several components at different temperatures. The results are compared with measurements from the IMP-6 satellite. In various frequency ranges, the noise power is dominated by Langmuir oscillations, by electron acoustic waves and by ion acoustic waves. The measurements are consistent with all of these, although the ion waves are not definitely observed, due to interference from shot noise.

Kellogg, P. J.↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Measurement of macroscopic plasma parameters with a radio experiment: Interpretation of the quasi-thermal noise spectrum observed in the solar wind

The ISEE-3 SBH radio receiver has provided the first systematic observations of the quasi-thermal (plasma waves) noise in the solar wind plasma. The theoretical interpretation of that noise involves the particle distribution function so that electric noise measurements with long antennas provide a fast and independent method of measuring plasma parameters: densities and temperatures of a two component (core and halo) electron distribution function have been obtained in that way. The polarization of that noise is frequency dependent and sensitive to the drift velocity of the electron population. Below the plasma frequency, there is evidence of a weak noise spectrum with spectral index -1 which is not yet accounted for by the theory. The theoretical treatment of the noise associated with the low energy (thermal) proton population shows that the moving electrical antenna radiates in the surrounding plasma by Carenkov emission which becomes predominant at the low frequencies, below about 0.1 F sub P.

Couturier, P.↗